Search PubMed⌕ Search

Biomedical subjects

L P Mark

Publications and source records attributed to L P Mark.

At least 37 records · Page 2Linked to original sources

Three-dimensional time-of-flight MR angiography with a surface coil: evaluation in 12 subjects.

We compared three-dimensional time-of-flight MR angiograms obtained with head coils and then with surface coils in five patients with intracranial vascular lesions and in seven normal volunteers to determine if imaging of intracranial vascular anatomy could be improved with the use of a surface coil. Visualization of small peripheral vessels was consistently better with a surface coil than with a head coil at identical small fields of view (FOVs). The surface-coil technique allowed small-FOV imaging of peripheral vascular lesions with higher spatial resolution and signal-to-noise ratio similar to that of large-FOV head-coil images. The use of a surface coil introduced the problem of signal falloff; centrally located vessels were visualized as well or better when a standard head coil was used. We conclude that surface-coil MR angiography can serve as a useful adjunct to routine head-coil MR angiography in the evaluation of peripheral vascular abnormalities.

Angiography↗

High-signal foci on MR images of the brain: observer variability in their quantification.

Foci of high signal in the cerebral white matter are common incidental findings on MR images of the brain of control subjects or patients with a variety of diseases. Although the number of foci has been reported to correlate with age and several risk factors, the degree of observer variability in quantifying foci has not been reported. We used kappa statistics to determine radiologists' agreement in counting high-signal-intensity foci on MR images obtained in healthy volunteers and in patients with hypertension. Before interpreting the images, one pair of radiologists studied 30 routine MR images and reached consensus on differentiating high-signal foci from other foci of high intensity caused by normal structures (e.g., deep gyri or Virchow-Robin spaces). These two observers than independently determined the number of foci in the study group. Using their own criteria, other radiologists independently counted the foci. Agreement between observers was determined with the kappa statistic. The results showed fair agreement between the radiologists who first reached a consensus in counting foci of hyperintensity and poor agreement between the other observers. We conclude that in order to compare the frequency of foci of hyperintensity in different groups of patients, observer variability must be controlled. Studies without proper control subjects may lead to incorrect conclusions regarding the correlation of focal hyperintensities and various risk factors.

Alzheimer Disease↗

MR imaging of optic nerve lesions: value of gadopentetate dimeglumine and fat-suppression technique.

Eleven patients with known or suspected optic nerve lesions and eight normal subjects were examined with spin-echo technique at 1.5 T with unenhanced T1-weighted imaging, IV gadopentetate-dimeglumine-enhanced T1-weighted imaging, and enhanced T1-weighted imaging with fat suppression. Two pathologically proved and four presumed optic nerve meningiomas demonstrated significant enhancement and were best seen with the fat-suppression technique. None of the three presumed optic nerve gliomas nor the optic nerves of normal subjects demonstrated qualitative enhancement. We conclude that the use of a fat-suppression technique with gadopentetate dimeglumine enhancement improves delineation of enhancing optic nerve lesions. This technique should be useful for evaluating other anatomic regions where enhancing tissue marginates fat.

Adipose Tissue↗

Gradient recalled echo MR imaging of superior sagittal sinus occlusion.

With T1-weighted gradient recalled echo (GRE) MR images and flow compensation, we studied the superior sagittal sinus in 3 normal volunteers and 3 patients with sinus occlusion. In these images, sites of patency of the superior sagittal sinus were identified due to the high signal intensity of the normal sinus. Tumor invading the sinus was nearly isointense with cerebral gray matter. T1-weighted GRE imaging proves to be an effective technique to evaluate sinus blood flow.

Cerebrovascular Circulation↗

MR imaging of facial nerve enhancement in Bell palsy or after temporal bone surgery.

The authors evaluated magnetic resonance (MR) images obtained with intravenously administered gadolinium in ten patients who had facial paralysis and no facial nerve tumor. In patients with either Bell palsy (four patients) or facial paralysis after temporal bone surgery (six patients), intratemporal facial nerve enhancement was seen. Facial nerve enhancement on MR images proved to be a nonspecific finding.

Facial Nerve↗

Contrast enhancement in spinal MR imaging.

We evaluated 44 patients with suspected spinal tumors or previous laminectomies with gadolinium-DTPA MR imaging in order to characterize the enhancement in normal, postoperative, and neoplastic intraspinal tissue. Using the signal intensity of CSF as an internal control, we calculated the percentage increase in signal intensity from pre- to postgadolinium studies. Tumors (astrocytoma, ependymoma, schwannoma) enhanced 70-350%; epidural scar, normal epidural venous plexus, and dorsal root ganglion enhanced up to 200%. Contrast enhancement does not per se distinguish neoplastic from normal tissue. Enhancement with gadolinium-DTPA appeared to increase the conspicuousness of intramedullary tumors but not intraosseous metastases. We believe that gadolinium-enhanced MR imaging is a valuable adjunct to routine MR imaging in the evaluation of intraspinal neoplastic processes and may be useful in delineating normal and postoperative structures in the spinal canal.

Contrast Media↗

MR imaging of the cavernous sinus: value of spin echo and gradient recalled echo images.

A detailed evaluation of the MR appearance of the pituitary gland-cavernous sinus junction has not been described. In a series of coronal T1-weighted spin echo images without and with IV gadolinium, we noted the variable size and signal intensity of cavernous venous spaces adjacent to the pituitary gland and the inconsistent visualization of the dural membrane just lateral to the gland. Correlation of coronal T1-weighted spin echo and gradient recalled echo images (the latter with high-signal-intensity vascular structures) proved to be an effective means of identifying cavernous venous spaces, connective tissue and cranial nerves, and the lateral margins of the pituitary gland, and of differentiating tumor tissue from cavernous venous spaces. Further work is needed to develop criteria to distinguish cavernous sinus compression from actual tumor invasion.

Adenoma↗

Cortical activation response to acoustic echo planar scanner noise.

PURPOSE: Our goal was to determine the distribution of auditory and language cortex activation in response to acoustic echo planar scanner noise with functional MRI (fMRI). METHOD: Acoustic scanner noise and spoken text, reproduced on high output cassette tape, were separately delivered at equivalent intensities to six normal hearing adult volunteers through earphones during fMRI data acquisition. In nine other subjects, taped scanner noise was delivered in five successive iterations of the task to assess the consistency of cortical activation to the noise stimulus. Gyri of the auditory and language system were divided into 10 different subregions for analysis of cortical activation. The number of activated pixels and proportion of volunteers activating each cortical subregion were determined using a cross-correlation analysis. RESULTS: Cortical activation to taped acoustic scanner noise was present within the transverse temporal gyrus (primary auditory cortex) in all subjects, but activation was highly variable between subjects in auditory association and language relevant cortex. Auditory association cortex activation was seen in the planum polari, planum temporali, and middle temporal gyrus/superior temporal sulcus regions in one-half to two-thirds of the volunteers. There was no significant difference in the distribution of cortical activation within individual subjects across five successive iterations of the scanner noise task. Listening to spoken text consistently activated primary and association auditory cortex bilaterally as well as language relevant cortex in some cases. The mean number of activated pixels was significantly greater for text listening than acoustic scanner noise in auditory association and language relevant cortical subregions (p < 0.01), although the distribution of activity was similar between the two tasks. CONCLUSION: This preliminary investigation suggests that the complex sounds produced by the echo planar pulse sequence can activate relatively large regions of auditory and language cortex bilaterally, with the extent of activation outside the primary auditory cortex being variable between subjects. However, the distribution of activation within individual subjects was relatively constant across several iterations of the scanner noise stimulus.

Adult↗

Acoustic echoplanar scanner noise and pure tone hearing thresholds: the effects of sequence repetition times and acoustic noise rates.

PURPOSE: Our goal was to determine the effects of acoustic echoplanar scanner noise on pure tone hearing thresholds in normal volunteers and to determine the influence of echoplanar sequence repetition time on threshold effects. METHOD: With use of a calibrated audiometer, pure tones ranging from 125 to 8,000 Hz were delivered monaurally to 10 normal-hearing volunteers in a quiet MR scanner suite and in the presence of acoustic scanner noise produced by three separate single shot blipped echoplanar pulse sequences varying only in repetition time (TR = 1,000, 2,000, or 3,000 ms), with all other parameters including the number of slices held constant. The magnitude of noise-induced threshold changes and the slopes of the threshold curves produced by each of the three echoplanar pulse sequences were then analyzed using multiple comparisons and a least significant difference method. The shapes of the threshold curves produced in each background state were best fit using a quadratic effect for frequency in a mixed effects linear model and compared using F test statistics. RESULTS: All of the volunteers demonstrated entirely normal hearing thresholds throughout the full range of tonal frequencies tested (< 25 dB) when no acoustic scanner noise was present in the scanner suite. Pure tone hearing thresholds significantly increased (p < 0.01) in the presence of acoustic scanner noise, with the magnitude of change inversely proportional to the repetition time and therefore the rate of periodic noise production by the echoplanar sequence used. The shape of the threshold curve in the presence of noise produced by the 1,000 ms TR sequence was not equivalent across the frequency spectrum tested but had a quadratic distribution with peak effects at 750-2,000 Hz. As the repetition time was increased and the periodic noise rate decreased, the magnitude of the noise-induced threshold changes significantly lessened (p < 0.01) and the quadratic distributions of the threshold curves changed significantly (p < 0.01), tending toward a more planar configuration. CONCLUSION: Background acoustic echoplanar scanner noise can significantly increase pure tone thresholds in the optimal frequency hearing range (125-8,000 Hz). However, the threshold effects are not equivalent across the frequency spectrum, and the magnitude of threshold changes is dependent on the rate at which periodic acoustic scanner noises are produced for a given sequence repetition time.

Acoustic Stimulation↗

Magnetization transfer imaging of skeletal muscle in autosomal recessive limb girdle muscular dystrophy.

PURPOSE: The purpose of this work was to characterize magnetization transfer (MT) contrast of skeletal muscles in limb girdle muscular dystrophy (LGMD). METHOD: The calf muscles of five LGMD patients and 10 normal volunteers were imaged with an off-resonance MT suppression pulse applied to T1-weighted images. MT suppression ratios were calculated for anterior tibialis, posterior tibialis, soleus, and gastrocnemius muscles in the LGMD and control groups. The relationship between MT of individual muscles and the duration of LGMD symptoms was determined. RESULTS: Strong MT contrast was observed in normal calf muscles, with mean (+/-SD) suppression ratios ranging from 37.9% (+/-3.0) to 41.1% (+/-2.1). In diseased muscle, MT signal suppression ranged from 11 to 38%, demonstrating an inverse relationship between symptom duration and suppression ratios. MT contrast in the LGMD patients, as a reflection of muscle tissue integrity, was preserved in posterior or anterior tibialis, soleus, and gastrocnemius muscles, respectively. Suppression ratios were dramatically reduced in muscles with gross fatty infiltration but also were reduced in muscle tissues without visual evidence of fatty infiltration. CONCLUSION: MT imaging provides a quantitative measure of pathologic changes occurring within the skeletal muscles of patients with LGMD relative to normal and may be useful in evaluating disease extent, progression, and response to new therapies as they become available.

Adolescent↗

High-intensity signals within the posterior pituitary fossa: a study with fat-suppression MR techniques.

Five different theories have been proposed to explain the high-intensity signals within the posterior pituitary fossa seen on MR: (1) a paramagnetic effect of phospholipids in the posterior lobe, (2) lipid in pituicytes in the posterior lobe of the pituitary, (3) neurosecretory granules in the posterior lobe, (4) fat within the sella but outside the pituitary gland, and (5) fat in bone marrow in the dorsum sellae. Previous reports have contained conflicting evidence on which of these structures is the cause of the high-intensity signals within the posterior sella. The purpose of this study was to examine the high-intensity signals of the normal posterior sella with fat-suppression MR techniques to reevaluate the contribution of fat to those signals. The sellae of 19 normal volunteers and two cadavers were imaged with MR with a commercially available unit and a research fat- water-suppression technique. High-intensity signals in the posterior sella were observed in all 21 subjects on conventional T1-weighted MR images. In two volunteers, the high-intensity signals in the posterior sella were suppressed with fat-suppression techniques; in 17 subjects the signals were suppressed with water-suppression techniques. In two volunteers the results were indeterminate. The high-intensity signals in the posterior sella do not behave like lipid in the majority of cases. Our study supports the conclusion that high-intensity signals in the posterior sella may have more than one source. It appears that most of these sources do not suppress with fat-suppression techniques.

Humans↗

MR imaging of optic nerve lesions: value of gadopentetate dimeglumine and fat-suppression technique.

Eleven patients with known or suspected optic nerve lesions and eight normal subjects were examined with spin-echo technique at 1.5 T with unenhanced T1-weighted imaging, IV gadopentetate-dimeglumine-enhanced T1-weighted imaging, and enhanced T1-weighted imaging with fat suppression. Two pathologically proved and four presumed optic nerve meningiomas demonstrated significant enhancement and were best seen with the fat-suppression technique. None of the three presumed optic nerve gliomas nor the optic nerves of normal subjects demonstrated qualitative enhancement. We conclude that the use of a fat-suppression technique with gadopentetate dimeglumine enhancement improves delineation of enhancing optic nerve lesions. This technique should be useful for evaluating other anatomic regions where enhancing tissue marginates fat.

Adult↗

Gradient recalled echo MR imaging of the jugular foramen.

Axial T1-weighted spin-echo MR images have not proved to be effective in identifying normal structures in the jugular foramen. By correlating cryomicrotomic sections and axial T1-weighted gradient recalled echo images, we identified the neural and vascular contents of the jugular foramen. Further work with gradient recalled echo images is needed to determine the signal characteristics of jugular foraminal lesions.

Glomus Jugulare Tumor↗

Magnetic susceptibility artifacts in gradient-recalled echo MR imaging.

Artifacts related to magnetic susceptibility differences between bone and soft tissue are prevalent on gradient-recalled echo images, particularly when long echo delay times are used. These susceptibility artifacts spatially distort and artifactually enlarge bone contours. This can alter the apparent shape of the spinal canal and exaggerate the degree of spinal stenosis seen in patients with cervical spondylosis. The effects of magnetic susceptibility artifacts in gradient echo imaging were studied in a phantom model and the results were correlated with MR images obtained in patients with cervical spondylosis.

Cervical Vertebrae↗

Limbic connections.

Explore the source record for details and available documents.

Brain Mapping↗