Search PubMed⌕ Search

Biomedical subjects

L Osborne

Publications and source records attributed to L Osborne.

43 records · Page 3Linked to original sources

Comparison of the pneumooculoplethysmography (GEE) and the digitalized pulse timing oculoplethysmography (ZIRA).

Comparative study of the pneumooculoplethysmography (OPG/Gee) and the digitalized pulse timing OPG (Zira) was conducted by analysis of 100 patients who had both OPG/Gee and Zira and carotid arteriograms. Both units were valuable in diagnosis of normal carotid arteries, 94 per cent for Gee and 89 per cent for Zira. The Gee unit was more valuable in the diagnosis of unilateral significant carotid stenosis, 90.3 per cent versus 75 per cent for the Zira machine. The Gee unit was also very valuable in detecting bilateral carotid stenosis, 90.4 per cent but the Zira unit was limited in this group; i.e., 60 per cent only. The overall accuracy of the OPG/Gee was superior to the OPG/Zira, 92 per cent versus 80 per cent.

Angiography↗

The value of combined strain gauge plethysmography and radioactive iodine fibrinogen scan of the leg in the diagnosis of deep vein thrombosis.

The fallibility of the clinical diagnosis of deep venous thrombosis has led to a variety of noninvasive diagnostic methods, for example, Doppler ultrasound, plethysmography, 125I fibrinogen and radionuclide phlebography. This study was undertaken to analyze the value of combined strain gauge plethysmography and 125I fibrinogen scan of the leg in the diagnosis of deep venous thrombosis. The study was carried out upon 368 patients with suggestive findings of venous thrombosis. Four hundred and fifty strain gauge plethysmograms were reviewed. Venograms were done upon 106 limbs and 125I fibrinogen leg scans, on 136 limbs. Of the 64 limbs with normal strain gauge plethysmograms which had venograms, 58 were normal, five had incompetent perforators and one limb had deep venous thrombosis. Of the 42 legs with abnormal strain gauge plethysmograms which had venograms, 25 had deep venous thrombosis, 15 had incompetent perforators and two were normal. Twenty-three of 24 legs having both abnormal strain gauge plethysmograms and leg scans were confirmed to have deep venous thrombosis at venography. Fourteen of 18 legs with abnormal strain gauge plethysmograms but normal scans were found to have incompetent perforators. We conclude, that the strain gauge plethysmogram is a reliable test in excluding deep venous thrombosis and, when combined with the fibrinogen leg scan, is reliable in its diagnosis.

Adolescent↗

The effect of lead on immune and viral interferon production.

Female BDF1 mice were exposed to lead acetate in the drinking water at concentrations ranging form 0 to 1000 micrograms/mL lead for three weeks. The mice tolerated these levels of lead exposure without exhibiting signs of clinical toxicity. Weight gains were not affected by lead exposure. The production of viral interferon induced by the oral administration of tilorone was not altered by lead exposure. The T-lymphocyte mitogens concanavalin A, phytohemagglutinin and staphylococcal enterotoxin A induced immune interferon to varying degrees, with concanavalin A and staphylococcal enterotoxin A exhibiting the most potent induction capabilities. The production of immune interferon induced by T-lymphocyte mitogens was not suppressed by lead exposure.

Animals↗

Phase I trial of Staphylococcus aureus Cowan I immunoperfusion.

Staphylococcus aureus Cowan I has shown antitumor activity in in vitro and in animal tumor models. It is hypothesized that this antineoplastic effect results from the interaction of protein A on the cell surface of Cowan I strain S. aureus and immunosuppressive circulating immune complexes. Therefore, we treated five patients with ex vivo plasma immuno-perfusion over killed and fixed S. aureus Cowan I. Toxic effects were marked in all patients and appeared to be related to the plasma volume infused and rate of infusion. Toxic reactions occurred in the cardiovascular, respiratory, and hematopoietic systems. No responses even minimal or transient, were observed in this phase I trial. This toxicity may be reduced if the rate of plasma infusion decreases.

Adult↗

Critical analysis of the digitalized pulse timing oculoplethysmography.

To critically analyze the accuracy of the OPG/Zira unit in the diagnosis of significant carotid artery stenosis, 135 patients (270 carotid arteries) were reviewed in comparison with the biplane carotid arteriograms. For practical purposes the radiological findings were divided into two categories; the first category included patients with normal carotids or carotids with less than 40% stenosis and the second category included patients who had carotid stenosis of greater than 40% (significant stenosis). The 136 arteries with significant stenosis on the arteriograms had positive OPG (136/160); i.e., 85.0% sensitivity, 101/110 arteries had negative arteriograms and negative OPG; i.e., 91.8% specificity. There was 6.2% false positive rate (9/145) and 19.2% false negative (24/125). The overall diagnostic accuracy was 87.7% (237/270).

Adult↗