Search PubMedSearch

Biomedical subjects

L Nyholm

Publications and source records attributed to L Nyholm.

3 recordsLinked to original sources

End-column amperometric detection in capillary electrophoresis: influence of separation-related parameters on the observed half-wave potential for dopamine and catechol.

Capillary electrophoresis (CE) was coupled to a micro-electrode-based end-column amperometric detector. The influences of separation voltage, CE buffer concentration, and capillary-to-electrode distance on the observed hydrodynamic voltammetry of dopamine and catechol were studied using a separation capillary with an i.d. of 25 microns. It was found that an increased CE voltage, increased buffer concentration, or decreased capillary-to-electrode distance resulted in a positive shift of the observed half-wave potentials for both dopamine and catechol. At a constant separation current of 1.6 microA, the observed half-wave potential was found to increase with applied separation voltage. Furthermore, when experiments were carried out with a platinum quasi-reference electrode instead of a Ag/AgCl reference electrode, similar shifts in half-wave potential were observed. These results indicate that the observed shifts are an effect of the separation voltage rather than the separation current or a change in the reference potential. The characteristics of end-column detection with and without a fracture decoupler were compared. It was found that the effects of separation voltage, CE buffer concentration, and capillary-to-electrode distance were minimized by the use of a decoupling device. The observed half-wave potentials for dopamine and catechol were more positive when a CE capillary without a decoupler was employed compared to when a decoupler was used. Additionally, using the fracture decoupler, the observed half-wave potentials for both dopamine and catechol were approximately the same as when no CE voltage was applied (i.e., when the hydrodynamic voltammograms were recorded under flow injection conditions).

Catechols

Immunochemical partial identity between two independently identified and isolated major allergens from Alternaria alternata (Alt-I and Ag 1).

Partially purified preparations of Alt-I, the main allergenic fraction of Alternaria alternata isolated by Yunginger, and of Ag 1, shown in crossed radioimmunoelectrophoresis (CRIE) to be the dominating major allergen of A. alternata (Løwenstein, Nyholm), were compared by tandem crossed immunoelectrophoresis (CIE), RAST inhibition, and the CRIE-related technique, single radial radioimmunodiffusion (SRRID). The two allergen preparations showed reaction of identity in tandem-CIE and indistinguishable specific IgE binding in CRIE and SRRID, regardless of antibodies and serum pools used. In RAST inhibition, the relative potencies of the allergen preparations and of the crude extracts correlated well with their Alt-I/Ag 1 content as estimated by rocket immunoelectrophoresis. Moreover, all inhibition curves were parallel, confirming identical IgE binding by Alt-I and Ag 1 with the serum pools used. A second preparation of Alt-I, isolated from another strain of Alternaria, showed reaction of partial identity with Ag 1 in tandem-CIE, indicating that different variants of Alt-I (Ag 1) may exist in different strains of A. alternata.

Allergens

Benchmarking: a case report.

In mid 1993, administrators and physicians at Bristol Medical Center teams up with HCIA to perform clinical pathway analysis on five diagnosis related groups. The major goal of this project was to establish a partnership between the hospital administration and the medical staff to meet or beat existing benchmarks.

Critical Pathways