Search PubMed⌕ Search

Biomedical subjects

L Mathiasson

Publications and source records attributed to L Mathiasson.

At least 19 recordsLinked to original sources

Development of methods for the determination of vitamins A, E and beta-carotene in processed foods based on supercritical fluid extraction: a collaborative study.

New methodologies based on supercritical fluid extraction (SFE) have been developed for the determination of fat-soluble vitamins in processed foods. The results obtained so far indicate that SFE is well suited to extraction of fat-soluble vitamins from food products, although validation work is required to establish accuracy and precision. The vitamins investigated were A, E and beta-carotene, and the processed foods were UHT milk, milk powder, minced meat, liver paste, infant formula, canned baby food and margarine. Extraction equipment employed analyte collection on either a solid-phase trap or in a solvent. After extraction, the samples were saponified and the vitamins determined using reversed-phase liquid chromatography with ultraviolet or fluorescence detection. Sample throughput was at least 12 samples day(-1), i.e. at least twice the number achievable with a conventional extraction methodology. The detection limits for the vitamins in different processed foods were well below 0.1 microg g(-1). Recoveries (in comparison with vitamin levels obtained using conventional solvent extraction) were close to 100% for experienced personal with access to modern automatic equipment. To reach this level, it was necessary to protect the vitamins with an antioxidant during the different steps of the analysis procedure, to add methanol or ethanol to the extraction cell to facilitate the analyte extraction from the food matrix, and when using a solid-phase trap, to employ a fractionated extraction-elution procedure to prevent breakthrough losses. The developed methods were tested in a validation exercise between five laboratories, which had taken part in the method development, and in an intercomparison between 10 laboratories including laboratories with less experience of vitamin determination. The within-laboratory RSD was generally < or = 11%. The average of the between-laboratory relative standard deviation (RSD) was about 23% in the validation, and increased to about 40% in the intercomparison. Ruggedness tests performed at different steps of the project showed that different types and models of equipment did not give large differences in recoveries. Thus, the increasing RSD can largely be ascribed to differences in experience in vitamin analysis of the participants.

Chromatography, Supercritical Fluid↗

Supercritical fluid extraction and chromatography for fat-soluble vitamin analysis.

Extraction and chromatographic separation of fat-soluble vitamins is a challenging task, due to the sensitivity of these compounds towards light, oxygen, heat and pH. In light of this, supercritical fluid extraction (SFE) and supercritical fluid chromatography (SFC) are attractive techniques as they function at considerably milder conditions than conventional solvent-based analytical techniques. Moreover, supercritical techniques consume much less amounts of organic solvents than conventional ones. This review gives a brief description of suitable supercritical media as well as basic theory on SFE and SFC processes. Furthermore, guidelines are provided for optimizing the important extraction and separation parameters to facilitate a successful method development. Finally, applications employing SFE and/or SFC for fat-soluble vitamin enrichment and final determination are reviewed.

Chromatography, Supercritical Fluid↗

On-line supercritical fluid extraction/enzymatic hydrolysis of vitamin a esters: a new simplified approach for the determination of vitamins a and e in food.

An on-line supercritical fluid extraction (SFE)/enzymatic hydrolysis procedure using immobilized lipase has been developed for the determination of vitamin A in dairy and meat products. Several lipases were tried, of which Novozyme 435 (Candida antarctica type B) showed the highest activity toward retinyl palmitate. There was no observed activity with alpha-tocopheryl acetate. When pressure, temperature, modifiers, flow rate, extraction time, and water content were varied, high vitamin A recovery was obtained in milk powder. Collected extracts were analyzed by reversed-phase high-performance liquid chromatography with ultraviolet and fluorescence detection without additional sample cleanup. The procedure gave reliable values of vitamin A as well as of vitamin E in other food items such as infant formula, minced pork and beef meat, and low- and high-fat liver paste. The described method is faster and more automated than conventional methods based on liquid-liquid extraction, or SFE using off-line saponification, for vitamin A and E determination. Results obtained with the new method did not differ significantly from those obtained with the other two methods mentioned above.

Animals↗

Determination of low concentrations of benzene in urine using multi-dimensional gas chromatography.

A method for the determination of benzene in urine of occupationally or environmentally exposed persons was developed. The method was based on dynamic headspace, preconcentration on a solid sorbent, followed by thermal desorption and gas chromatographic determination. To achieve sufficient selectivity, we used multi-dimensional gas chromatography in combination with the inexpensive and robust flame ionisation detector. The limit of detection was 7 ng l-1 and the limit of quantification was 23 ng l-1. The linearity was good (correlation coefficient 0.999) in the range examined (20-4000 ng l-1) and the repeatability was 9%. The average recovery at low concentrations (20-400 ng l-1) was 86%. Analysis of a certified reference material of benzene in water, traceable to NIST, did not differ significantly from the certified value. Samples, frozen (-20 degrees C) in glass bottles sealed with Teflon-silicon septa, were stable for 1 year and refrigerated samples (4 degrees C) for at least 1 week. Loss of benzene during the collection and transfer of urine was investigated and found to be acceptable. The method is a cost effective and robust alternative to GC-MS and permits reliable quantification of occupational exposure and, in most cases, also of urine concentrations that can be expected from environmental exposure.

Benzene↗

Membrane-based techniques for sample enrichment.

Sample preparation techniques based on non-porous membrane extraction generally offer a high degree of selectivity and enrichment power, together with convenient possibilities for direct and automated connections to chromatographic and other analytical instruments. In this review principles and applications for techniques as supported liquid membrane extraction, microporous membrane liquid-liquid extraction, polymeric membrane extraction and membrane extraction with a sorbent interface are described and compared.

Body Fluids↗

Determination of thiophanate-methyl and its metabolites at trace level in spiked natural water using the supported liquid membrane extraction and the microporous membrane liquid-liquid extraction techniques combined on-line with high-performance liquid chromatography.

On-line supported liquid membrane (SLM) extraction and microporous membrane liquid-liquid extraction (MMLLE) techniques for sample preparation of natural water samples have been developed for the determination of thiophanate-methyl (TM), carbendazim (MBC) and 2-aminobenzimidazole (2-AB) using reversed-phase HPLC. The combination of SLM extraction and MMLLE offers extraction conditions that makes it possible to determine a wide variety of compounds, i.e., permanently charged, ionisable and non-polar at sub ppb level. The detection limits obtained after extraction are about 0.1 microg/l for MBC and 2-AB using SLM, and 0.5 x Lg/l for TM using MMLLE and the precision is better than 5% for both systems. Typical enrichment rates are 0.6 and 2.7 times/min using SLM and MMLLE, respectively.

Chromatography, High Pressure Liquid↗

Introducing selective supercritical fluid extraction as a new tool for determining sorption/desorption behavior and bioavailability of persistent organic pollutants in sediment.

This review article intends to introduce the possibility of utilizing selective supercritical fluid extraction (SFE) as a tool to study sorption/desorption processes and bioavailability of persistent organic pollutants (POP) in sediment. Sorption/desorption behavior and bioavailability studies of POPs is a large research area, but still many unsolved problems exists. Therefore novel approaches to investigate mechanistic behavior of POPs in sediments are needed. Present literature on SFE points to the fact that selective SFE measurements can improve our knowledge, and recent investigations have been performed that demonstrate this. Results obtained with selective SFE can be connected to desorption of POPs in sediments under natural conditions in aquatic ecosytems. The ultimate goal is to use selective SFE as a way to determine the bioavailable fraction present within a matrix. A few preliminary results are presented here which may serve as a starting point for future studies.

Adsorption↗

Determination of food constituents based on SFE: applications to vitamins A and E in meat and milk.

A method has been developed for the determination of vitamins A and E in food using supercritical fluid extraction (SFE), applying liquid or solid trapping, with an accuracy equal to conventional solvent extraction methods. Under optimal conditions, using methanol modified carbon dioxide as a supercritical fluid, Hydromatrix as a water adsorbent, and with a small amount of ascorbic acid and methanol added to the sample, the extraction time is reduced to 80 min. This time is considerably shorter than in conventional methods. Other advantages are the reduction of manual manipulations leading to lower labour costs and reduced consumption of organic solvents in the sample preparation step.

Animals↗

Utilization of fat retainers in supercritical fluid extraction for the selective extraction of polychlorinated biphenyls from a model fat sample.

Two common fat retainers used in supercritical fluid extraction--basic alumina and the silica based adsorbent Florisil--were investigated using lard fat as model material. With a fat retainer in the extraction cell it was possible to obtain fat-free time windows. Activation by heating did not influence the length of the time windows, while deactivation of the retainers with 10% water (w/w) drastically decreased the fat retaining capabilities. The influence of modifier addition was also investigated. Finally, a method was developed, where basic alumina was utilized to selectively extract polychlorinated biphenyls (PCBs) from a model fat sample, containing PCBs, triglycerides and phospholipids. The PCBs could be quantitatively extracted in a totally fat-free time window.

Chromatography↗

Determination of vitamins A and E in milk powder using supercritical fluid extraction for sample clean-up.

A method for the analysis of the natural contents of vitamins A and E in milk powder has been developed. The method utilises supercritical fluid extraction, a miniaturised alkaline saponification procedure and reversed-phase HPLC with UV detection. Modifications of the sample matrix, combinations of static and dynamic modes of extraction and effects of changes in extraction parameters such as temperature, flow-rate, time, collection solvent and collection temperature were studied to optimise the extraction efficiency and selectivity. Supercritical CO2 at 80 degrees C and 37 MPa, modified with 5% methanol and pumped at a flow-rate of 1.0 ml/min, gave recoveries of 99 and 96% for vitamins A and E, respectively, using a 15 min static followed by a 15 min dynamic extraction. The measurements gave a within-day RSD of 4% for both vitamin A and E, and between-day RSDs of 4 and 8% for vitamins A and E, respectively.

Animals↗

Automated liquid membrane extraction for high-performance liquid chromatography of Ropivacaine metabolites in urine.

An automatic method for the determination of metabolites of Ropivacaine in urine was set up. It utilizes supported liquid membrane extraction for sample clean-up and enrichment, followed by ion-pair chromatography determination using UV detection. The extraction was very selective with no observed interfering compounds from the urine matrix, permitting simple isocratic chromatographic analysis. The detection limits for spiked urine samples were 2-18 nM for the different compounds. The repeatability was 1-3% (RSD) with an internal standard that was also extracted, and about twice without this standard. A throughput of 3.3 samples per hour was achieved and the liquid membrane was stable for more than a week.

Amides↗

Microporous membrane liquid-liquid extraction coupled on-line with normal-phase liquid chromatography for the determination of cationic surfactants in river and waste water.

Membrane-based continuous liquid-liquid extraction combined on-line with normal-phase liquid chromatography is proposed for the determination of cationic surfactants in complex aqueous samples. The technique has the potential for complete automation. Selective enrichment of cationic surfactants from spiked river water and waste-water samples with simultaneous removal of matrix constituents, followed by a quantitative transfer of the extract onto a liquid chromatographic column and separation of the surfactant homologues yielding low detection limits, has been realised. The homologues of alkyldimethylbenzylammonium chloride (Dodigen 226) were chosen as model compounds in the method development. Dodigen homologues were ion-paired with heptanoic acid and extracted into chlorobutane by means of microporous membrane liquid-liquid extraction. It was thereby possible to attain an enrichment of over 250 times for one of the homologues, viz. the concentration in the organic liquid is 250 times higher than in the original sample. Detection limits for the three best-detected homologues of the mixture were in the range 0.7-5 microg/l in spiked river water samples. Ion-pair normal-phase liquid chromatography, again with heptanoic acid as counter-ion, gave the necessary separation of the surfactant homologues.

Cations↗

Supercritical fluid extraction of the pesticides carbosulfan and imidacloprid from process dust waste.

Large amounts of contaminated process dust remain from the procedure of pesticide treatments applied to seed pellets. A pilot study in analytical-scale supercritical fluid extraction (SFE) was performed to determine the possibility of using supercritical carbon dioxide for the extraction of the nonpolar insecticide carbosulfan and the more polar insecticide imidacloprid present in contaminated dust waste, at concentrations of up to 20% (w/w). The effects of various experimental conditions, such as temperature, flow rate, and addition of modifier, on the recovery of the analytes were evaluated by extracting the pesticides both from spiked support material and from real dust samples. It was found that carbosulfan could easily be extracted from the dust waste within 30 min at 138 bar and 40 degrees C with a recovery of 98.9% (RSD = 2.3%, n = 10), compared to values obtained with a validated liquid extraction method. A sufficient removal of the more polar substance imidacloprid required the addition of a modifier, and the results showed a strong dependence of the extraction efficiency on the choice of modifier. Extractions at 276 bar and 80 degrees C with a solvent consisting of supercritical carbon dioxide modified with methanol (5%) gave a recovery of 97.0% (RSD = 3.6%, n = 10) using a 40 min extraction time. The results indicate that it seems to be possible to use process-scale SFE for the decontamination of pesticides from dust waste. The conditions outlined also permit analytical determinations of the two insecticides based on a combination of SFE and liquid chromatography.

Carbamates↗

Specific determination of benzene in urine using dynamic headspace and mass-selective detection.

A method for the determination of benzene in urine was developed, based on dynamic headspace and preconcentration of the analyte on a solid sorbent. The subsequent analysis by thermal desorption of the sorbent, capillary gas chromatography and mass-selective detection ascertained a low limit of detection (6.5 ng/l) and a highly specific determination. The limit of detection is an order of magnitude lower than that reported earlier and allows reliable quantitation of occupational exposure and of most environmental exposures. Samples could be stored frozen for at least a month without significant loss.

Benzene↗

On-line microporous membrane liquid-liquid extraction for sample pretreatment combined with capillary gas chromatography applied to local anaesthetics in blood plasma.

A new automated procedure for analyzing complex samples has been developed utilizing microporous membrane liquid-liquid extraction (MMLLE) combined with capillary gas chromatography. Some local anaesthetics were used as model compounds in aqueous solution as well as in blood plasma. The MMLLE procedure was performed in a flow system with the sample fed to the donor side of the hydrophobic microporous membrane and with an organic solvent (hexane) in the pores and as the acceptor solution. The analytes in a small volume of sample (< 1 mL) were extracted into the organic acceptor phase which was transferred into the gas chromatographic system by utilizing a loop-type interface compatible with large-volume (300 microL) injection. High selectivity and low carry-over effects were obtained with the system. The detection limits were 0.5-1 ng/mL using 0.5 mL of human plasma, and the precision was approximately 5%. The effects of pH, flow rates, and adsorption of the analytes were evaluated.

Adsorption↗

Supported liquid membrane coupled on-line to potentiometric stripping analysis at a mercury-coated reticulated vitreous carbon electrode for trace metal determinations in urine.

A method for trace metal determinations in complex matrices is presented. The method combines supported liquid membrane (SLM) sample clean-up and enrichment with potentiometric stripping analysis (PSA) in a flow system using reticulated vitreous carbon (RVC) as the electrode material. The membrane contained 40% m/m di-2-ethylhexylphosphoric acid dissolved in kerosene. Lead was used as a model substance in high-purity water and urine samples. The samples were enriched after a simple pH adjustment. The SLM enrichment time was 10 min when the last 5 min electrodeposition on the RVC electrode at -1.0 V (versus Ag/AgCl) was performed simultaneously. The influence of various experimental parameters such as deposition time, deposition potential and flow rate on the lead signal was investigated. With a 10 min SLM enrichment including a 5 min deposition time, the detection limit for lead was 0.3 microgram l-1. The relative standard deviation for lead concentrations in the range 4-20 micrograms l-1 was 0.05%. The overall SLM-PSA system was found to be stable for at least 100 urine analyses. The method was validated by running a reference urine sample. The result obtained (five replicates) was 9.7 micrograms l-1 (standard deviation 1.8 micrograms l-1) which is within the recommended range of 9.2-10.8 micrograms l-1.

Electrodes↗

On-line supported liquid membrane-liquid chromatography with a phenol oxidase-based biosensor as a selective detection unit for the determination of phenols in blood plasma.

The potential of on-line combination of supported liquid membrane extraction and column liquid chromatography with a phenol oxidase-based biosensor as a selective detection unit has been investigated for the determination of phenols in human plasma. The phenols are selectively extracted into a porous PTFE (polytetraflouroethene) membrane impregnated with a water-immiscible organic solvent and further into an alkaline acceptor phase. Via an ion-exchange interface, the analytes are transferred to a reversed-phase column where they are separated and detected using the biosensor. No sample pretreatment before the extraction, except centrifugation, is made. Due to the high selectivity both in the extraction and in the detection steps and to the fact that the demands on the chromatographic separation are low, a quick separation using an eluent with a low concentration of organic modifier can be made, without affecting the biosensor response. Detection limits below the 50 microg/l level in blood plasma were obtained for the three model compounds, phenol, p-cresol and 4-chlorophenol.

Biosensing Techniques↗