Search PubMed⌕ Search

Biomedical subjects

L M Williamson

Publications and source records attributed to L M Williamson.

At least 37 records · Page 2Linked to original sources

Platelet storage lesion of WBC-reduced, pooled, buffy coat-derived platelet concentrates prepared in three in-process filter/storage bag combinations.

BACKGROUND: With the implementation of universal WBC reduction in the United Kingdom, in-process WBC-reduction filters for pooled buffy coat (BC)-derived platelet concentrates (PCs) are used in routine production. The effects of three filter/storage bag combinations on platelet activation and microvesiculation and on the activation of coagulation were investigated. STUDY DESIGN AND METHODS: Using pooled BCs from the same donors, three filter/storage bag combinations (Autostop BC/CLX, Pall Biomedical; Sepacell PLX5/PL2410, Asahi Medical; and Imugard III-PL 4P/Teruflex, Terumo) were compared with unfiltered controls for their effects on microvesiculation and other storage-induced changes in platelets. Process efficiency was measured by platelet yield and residual WBC count. The storage changes were assessed: pH, activation of platelets measured by CD62P on the platelet surface and in supernatant plasma, quantitation of platelet-derived and RBC-derived microvesicles, cellular injury measured by annexin V in the supernatant plasma, and activation of the coagulation system measured by kallikrein-like and thrombin-like activities, prothrombin fragment 1+2, and thrombin-antithrombin complex. RESULTS: All three filters were comparable in terms of platelet recovery and WBC removal, and none induced immediate platelet activation or microvesiculation. With storage, platelet activation or microvesiculation increased in platelets prepared by all three filters and in unfiltered controls, but these effects were significantly less in the Imugard PCs than in controls. These findings were consistent with those for annexin V in the supernatant plasma, which were lower in Imugard PCs than in other products. Sepacell and Imugard filters reduced RBC-derived microvesicles to 50 percent of control levels, but the Autostop filter had no effect. On storage, levels of RBC-derived microvesicles in filtered products remained static, but levels in the unfiltered control doubled. Kallikrein- and thrombin-like activities were generated only by the Autostop filter without any further increment on storage. CONCLUSION: WBC-reduced pooled BC-PCs prepared by various filter/bag combinations were equivalent on Day 1 but differed during storage in terms of platelet activation or microvesiculation.

Annexin A5↗

Residual subset population analysis in WBC-reduced blood components using real-time PCR quantitation of specific mRNA.

BACKGROUND: Implementation of WBC reduction of the blood supply increases the importance of measurement of residual WBC subtypes responsible for immunologic and infectious complications of transfusion. STUDY DESIGN AND METHODS: Real-time RT-PCR assays were developed to detect mRNA encoding lineage-specific WBC markers. Primers and fluorescent probes were designed for CD45 (pan-WBC), CD3 (T-lymphocyte), CD19 (B-lymphocyte), CD14 (monocyte), and CD66 (granulocyte), and the specificity was assessed by comparison with flow cytometric analysis of enriched cell populations. WBC subsets were examined in WBC-reduced whole blood prepared with filters (WBF2, Pall; and RZ2000, Baxter) and in platelet concentrates prepared with other filters (Autostop, Pall; and PLX-5, Baxter) and apheresis (COBE Spectra LRS, Gambro). RESULTS: All real-time RT-PCR assays were linear over >5 log concentration range, allowing pre-WBC-reduction and post-WBC-reduction comparisons. Sensitivity limits ranged from 10 cells per mL (CD45) to 200 cells per mL (CD19). Assay specificity was confirmed by the close correlation of real-time RT-PCR and immunophenotyping results by flow cytometry. For all subsets, >3.8 log and >3.1 log reduction was obtained during WBC reduction of whole blood and platelets, respectively. CONCLUSION: Real-time RT-PCR assays are suitable for analysis of subset removal during WBC reduction. There was no significant difference between the two whole-blood filters or between platelet filtration and apheresis in the removal of any WBC subset.

Antigens, CD↗

The Gay Men's Task Force: the impact of peer education on the sexual health behaviour of homosexual men in Glasgow.

OBJECTIVE: To assess the impact of a peer education intervention, based in the "gay" bars of Glasgow, which sought to reduce sexual risk behaviours for HIV infection and increase use of a dedicated homosexual men's sexual health service, and in particular increase the uptake of hepatitis B vaccination. DESIGN: Self completed questionnaires administered to men who have sex with men (MSM) in Glasgow's gay bars. SUBJECTS: 1442 men completed questionnaires in January 1999, 7 months after the end of the 9 month sexual health intervention. MAIN OUTCOME MEASURES: Self reported contact with the peer education intervention, reported behaviour change, and reported sexual health service use. RESULTS: The Gay Men's Task Force (GMTF) symbol was recognised by 42% of the men surveyed. Among men who reported speaking with peer educators 49% reported thinking about their sexual behaviour and 26% reported changing their sexual behaviour. Logistic regressions demonstrated higher levels of HIV testing, hepatitis B vaccination, and use of sexual health services among men who reported contact with the intervention. These men were more likely to have used the homosexual specific sexual health service. Peer education dose effects were suggested, with the likelihood of HIV testing, hepatitis B vaccination, and use of sexual health services being greater among men who reported talking to peer educators more than once. CONCLUSION: The intervention had a direct impact on Glasgow's homosexual men and reached men of all ages and social classes. Higher levels of sexual health service use and uptake of specific services among men who had contact with the intervention are suggestive of an intervention effect. Peer education, as a form of health outreach, appears to be an effective intervention tool in terms of the uptake of sexual health services, but is less effective in achieving actual sexual behaviour change among homosexual men.

Adolescent↗

A rapid one-stage whole-blood HPA-1a phenotyping assay using a recombinant monoclonal IgG1 anti-HPA-1a.

Severe neonatal alloimmune thrombocytopenia and patients with HPA-1a-specific antibodies require transfusion of HPA-1a-negative platelets. Identifying HPA-1a-negative donors requires simple and reliable typing methods. Most existing techniques use polyclonal antibodies, are time consuming and involve platelet isolation. We have used a horseradish peroxidase (HRP)-conjugated recombinant IgG1 anti-HPA-1a (CAMTRAN007) to develop a rapid and reliable enzyme-linked immunosorbent assay (ELISA), which eliminates sample preparation and reduces the incubation and wash steps associated with traditional sandwich ELISAs. The assay uses simultaneous incubation of the monoclonal antibody RFGP56 to capture GPIIbIIIa from whole blood and the recombinant IgG1 antibody to detect captured HPA-1a antigen. It allows 96 samples to be typed in less than 1 h and can be used on stored samples. Initial testing of 85 samples of known HPA-1a genotype demonstrated that HPA-1a-negative samples had OD values of < 0.266, whereas HPA-1a-positive samples had OD values of > 0.6. Testing of 1862 random donor samples in two blood centres confirmed these OD cut-off values and identified 45 HPA-1a-negative samples (2.4%), all except one giving OD values of < 0.2. The remaining HPA-1a-negative sample had an OD value of 0.303. The HPA-1a status on all the negative samples and an equivalent number of randomly selected positive samples was confirmed by flow cytometry and polymerase chain reaction with sequence-specific primers (PCR- SSP).

Antigens, Human Platelet↗

Coagulation factor content of cryoprecipitate prepared from methylene blue plus light virus-inactivated plasma.

Levels of factor VIII (FVIII) and fibrinogen were assessed in control cryoprecipitate and cryoprecipitate prepared in two centres from plasma subjected to methylene blue (MB) photochemical virus inactivation. The level of coagulation FVIII activity was reduced in plasma by approximately 30% after MB photoinactivation, with only 44% (centre A) and 31% (centre B) of units meeting the current UK specification of 0.7 iu/ml. A revised specification of 0.5 iu/ml is suggested. Losses of less than 11% were seen for von Willebrand factor (VWF)-related activities. Cryoprecipitate prepared from group O or group A MB-treated plasma contained 27-40% less FVIII than control units. This reflected the lower levels in MB-treated plasma. The concentrating power of the cryoprecipitation process was not reduced for FVIII or fibrinogen in MB-treated units. MB cryoprecipitate from centre A still met the UK guideline specification for FVIII and fibrinogen content, whereas at centre B only 62.5% of the group O cryoprecipitates contained > 70 iu FVIII/unit. This may reflect the lower product volume and lower FVIII content of group O plasma used at centre B and suggests that maintenance of total coagulation factor recovery in MB-treated cryoprecipitate will require the higher product volume.

Antigens↗

Leucocyte depletion of blood components.

Universal leucocyte depletion has been implemented in the UK and several other European countries as a precautionary measure against the potential risk of transmission of variant Creutzfeldt-Jakob disease by blood transfusion. Leucocyte depletion had previously only been recommended for a relatively small proportion of transfusion recipients based on clinical and experimental evidence showing clinical benefit. However there is now increasing evidence to support its value in preventing transfusion transmission of infectious agents and in reducing some of the adverse immunomodulatory effects of allogeneic transfusion. The financial costs of providing universal leucocyte depletion are substantial, but, if it transpires that leucocyte depletion has a beneficial effect in reducing, for example, postoperative infection rates, then the health economic gains in this patient group alone may largely or wholly offset these financial costs. The experience in the UK and other European countries in terms of these collateral clinical benefits will help other countries, where the risk of variant Creutzfeldt-Jakob disease may not be so great, to decide whether to similarly adopt universal leucocyte depletion.

Erythrocyte Transfusion↗

Serious hazards of transfusion (SHOT) initiative: analysis of the first two annual reports.

OBJECTIVE: To receive and collate reports of death or major complications of transfusion of blood or components. DESIGN: Haematologists were invited confidentially to report deaths and major complications after blood transfusion during October 1996 to September 1998. SETTING: Hospitals in United Kingdom and Ireland. SUBJECTS: Patients who died or experienced serious complications, as defined below, associated with transfusion of red cells, platelets, fresh frozen plasma, or cryoprecipitate. MAIN OUTCOME MEASURES: Death, "wrong" blood transfused to patient, acute and delayed transfusion reactions, transfusion related acute lung injury, transfusion associated graft versus host disease, post-transfusion purpura, and infection transmitted by transfusion. Circumstances relating to these cases and relative frequency of complications. RESULTS: Over 24 months, 366 cases were reported, of which 191 (52%) were "wrong blood to patient" episodes. Analysis of these revealed multiple errors of identification, often beginning when blood was collected from the blood bank. There were 22 deaths from all causes, including three from ABO incompatibility. There were 12 infections: four bacterial (one fatal), seven viral, and one fatal case of malaria. During the second 12 months, 164/424 hospitals (39%) submitted a "nil to report" return. CONCLUSIONS: Transfusion is now extremely safe, but vigilance is needed to ensure correct identification of blood and patient. Staff education should include awareness of ABO incompatibility and bacterial contamination as causes of life threatening reactions to blood.

Blood Component Transfusion↗

Recombinant human IgG molecules lacking Fcgamma receptor I binding and monocyte triggering activities.

Subclasses of human IgG have a range of activity levels with different effector systems but each triggers at least one mechanism of cell destruction. We are aiming to engineer non-destructive human IgG constant regions for therapeutic applications where depletion of cells bearing the target antigen is undesirable. The attributes required are a lack of killing via Fcgamma receptors (R) and complement but retention of neonatal FcR binding to maintain placental transport and the prolonged half-life of IgG. Eight variants of human IgG constant regions were made with anti-RhD and CD52 specificities. The mutations, in one or two key regions of the CH2 domain, were restricted to incorporation of motifs from other subclasses to minimize potential immunogenicity. IgG2 residues at positions 233 - 236, substituted into IgG1 and IgG4, reduced binding to FcgammaRI by 10(4)-fold and eliminated the human monocyte response to antibody-sensitized red blood cells, resulting in antibodies which blocked the functions of active antibodies. If glycine 236, which is deleted in IgG2, was restored to the IgG1 and IgG4 mutants, low levels of activity were observed. Introduction of the IgG4 residues at positions 327, 330 and 331 of IgG1 and IgG2 had no effect on FcgammaRI binding but caused a small decrease in monocyte triggering.

Amino Acid Sequence↗

Evidence that anti-HBc but not HBV DNA testing may prevent some HBV transmission by transfusion.

Blood donor screening for antibody to hepatitis B core antigen (anti-HBc) implemented in some countries as a surrogate marker for non-A, non-B hepatitis has been superseded by anti-HCV screening. To assess the value of anti-HBc screening for the detection of hepatitis B surface antigen-negative blood donations that might contain infectious HBV, HBV genomic detection and recipient testing were used. Blood donations were screened and confirmed by multiple anti-HBc assays. Donations containing isolated anti-HBc and those with anti-hepatitis B surface antigen (anti-HBs) level < 0.1 IU/ml were tested for the presence of HBV DNA. Recipients of previous donations from the corresponding donors during the previous 5 years were traced and tested for markers of HBV infection. Of 103 869 donations screened, 586 (0.56%) were anti-HBc positive, two of which contained HBsAg, and 413 (0.4%) had protective (>/= 0.1 IU/ml) levels of anti-HBs. Anti-HBs < 0.1 IU/ml was found in 102 of these donations (0.1%) and isolated anti-HBc in 69 (0.07%). No donations with isolated anti-HBc were HBV DNA confirmed positive. Of 278 recipients of previous donations from 171 donors at risk of HBV carriage, 12 had markers of HBV infection. Six recipients had other identified risk factors. An association with blood transfusion was considered probable in two and possible in four recipients. None of the six corresponding donors had detectable HBV DNA 6-40 months after the implicated donation. The frequency of HBV transmission by chronic carriers negative for hepatitis B surface antigen was estimated in this study to be 1 in 52,000 donations (CI 0.3-7.8/100,000) from HBsAg-negative donors. Such HBV infectious donations may not be detected by DNA amplification.

Amino Acid Sequence↗

Solvent/detergent fresh frozen plasma as primary treatment of acute thrombotic thrombocytopenic purpura.

Three patients with acute thrombotic thrombocytopenic purpura (TTP) (one associated with E. coli infection) received as primary treatment pooled fresh frozen plasma (FFP) virus inactivated by the solvent/detergent (SD) method, plus prednisolone. All three patients attained platelet counts of > 50 x 10(9)/l by days 7, 3 and 10, respectively. Serum creatinine became corrected in parallel. Neurological features were slow to resolve in one patient, and developed de novo during plasma infusion in another with rapid reversal once intensive plasma exchange with SDFFP was instituted. All patients are in stable remission > 1 years later. SDFFP was well tolerated with no febrile or other reactions, and all patients remained negative for markers of infection with HIV, hepatitis B and hepatitis C viruses. One patient was positive for antibodies for hepatitis A virus and parvovirus B19 prior to treatment. The other two patients remained antibody negative at the end of therapy.

Adult↗

Prevention of transfusion-transmitted cytomegalovirus infection.

Cytomegalovirus (CMV) is a double-stranded DNA virus which can be transmitted by blood transfusion. Its seroprevalence in adults ranges from 40% to 100% depending on geographical and socioeconomic conditions. Seropositive individuals have latent CMV infection with viral DNA present in peripheral blood leucocytes. CMV can be associated with considerable morbidity and mortality in susceptible individuals, e.g. CMV-seronegative bone marrow allograft patients. Evidence, from a number of reports, suggests that provision of leucodepleted blood components may be as effective as the use of components from CMV-seronegative donors in preventing CMV infection and disease. This is relevant in the UK because Blood Transfusion Services are implementing universal leucodepletion of cellular blood components to minimize the theoretical risk of transmission of new variant Creutzfeldt-Jakob disease. This review examines data on the biology of CMV, discusses options for testing and summarizes the impact of CMV-seronegative and leucodepleted blood components on transfusion-transmitted CMV.

Antibodies, Viral↗

Evaluation of plasma and red cells obtained after leucocyte depletion of whole blood.

We evaluated whole blood integral filtration to produce leucocyte-depleted red cells and plasma by using the WBF1 whole blood filter (Pall Medsep). Whole blood units were filtered after either warm (2-4 h at room temperature) or cold (12-24 h at 4 degrees C) holds. Filtered and control units were processed using either a bottom-and-top or top-top method. Red cells were tested weekly for 6 weeks, and plasma 3 monthly for 12 months. All filtered red-cell packs contained < 5 x 10(6) leucocytes/unit with 71 of 72 containing < 1 x 10(6) leucocytes/unit. No clinically significant differences in red-cell storage parameters were seen, although haemolysis was less and pO2/pCO2 values were better maintained in filtered units. Plasma units contained < 2.5 x 10(3) leucocytes/unit with no significant loss of factor VIII except in the warm hold units processed by the top-top method. There was no evidence of complement or coagulation activation with significant removal of preformed C3a in cold hold units. Plasma storage parameters were maintained at control levels for 12 months.

Erythrocyte Count↗

Rapid phenotyping of HPA-1a using either diabody-based hemagglutination or recombinant IgG1-based assays.

BACKGROUND: The HPA-1 system is carried on the beta3 integrin. HPA-1a (Zw(a), Pl(A1)) is immunogenic in an HPA-1b homozygote (HPA-1b1b). In pregnancy, 1 of 365 women forms anti-HPA-1a, which causes severe thrombocytopenia in 1 in 1100 neonates. Identification of women at risk of forming anti-HPA-1a and the screening of donors to obtain HPA-1a-negative platelets for therapy need reliable, low-cost, automated assays. STUDY DESIGN AND METHODS: A diabody with dual specificity for HPA-1a x D and an IgG1 anti-HPA-1a have been constructed by the use of the genes encoding the first anti-HPA-1a fragment. With these reagents, two complementary HPA-1a phenotyping assays have been developed. RESULTS: This diabody was used in a simple hemagglutination technique to perform HPA-1a phenotyping on soluble glycoprotein IIb/IIIa from EDTA plasma samples. Over 1000 unselected donors have been correctly HPA-1a-phenotyped by use of the diabody. The human recombinant IgG1 anti-HPA-1a was produced in a rat myeloma cell line and was fluorescein labeled for use in a whole-blood flow cytometric HPA-1a phenotyping assay. This IgG1 anti-HPA-1a shows a clear differential between HPA-1a-positive and HPA-1a-negative platelets at nM antibody concentrations. CONCLUSIONS: The two recombinant reagents described are highly suitable for screening and confirmatory HPA-1a phenotyping. They permit rapid determination of the HPA-1a phenotype and are amenable to automation.

Antigens, CD↗

Systems contributing to the assurance of transfusion safety in the United Kingdom.

In 1996, the United Kingdom launched a voluntary 'haemovigilance' system for confidential reporting of transfusion-related deaths and major adverse events. The Serious Hazards of Transfusion (SHOT) initiative provided the first comprehensive overview of transfusion safety in the UK, with 12 fatalities reported in the first year. The most important finding was that of a total of 169 reports, 47% were 'wrong blood to patient' episodes, of which 16 were ABO-incompatible. There were eight transfusion-transmitted infections, three bacterial, four viral and one malarial. A number of other initiatives exist in the UK which also have importance in contributing to transfusion safety. This article reviews these other key contributors, allowing SHOT to be placed in context.

Accreditation↗

The natural history of fetomaternal alloimmunization to the platelet-specific antigen HPA-1a (PlA1, Zwa) as determined by antenatal screening.

Immunization against the human platelet antigen (HPA)-1 alloantigen is the most common cause of severe fetal and neonatal thrombocytopenia. Fetal therapy has substantial risks and its indications need better definition. Of 24,417 consecutive pregnant women, 618 (2.5%) were HPA-1a negative of whom 385 entered an observational study. All were HLA-DRB3*0101 genotyped and screened for anti-HPA-1a. Their partners and neonates were HPA-1 genotyped and the latter were assessed by cord blood platelet counts and cerebral ultrasound scans. Anti-HPA-1a was detected in 46 of 387 pregnancies (12.0%; 95% CI 8.7%-15.2%). All but one were HLA-DRB3*0101 positive (odds ratio 140; 95% CI 19-1035; P< .00001). One baby died in utero, and of 26 HPA-1a-positive babies born to women with persistent antenatal antibodies, 9 were severely thrombocytopenic (8 with a count <10 x 10(9)/L, 1 with a large porencephalic cyst), 10 were mildly thrombocytopenic, whereas 7 had normal platelet counts. Severe thrombocytopenia was significantly associated with a third trimester anti-HPA-1a titer >/= 1:32 (P = . 004), but was not observed in babies of women with either transient or postnatal-only antibodies. HPA-1a alloimmunization complicates 1 in 350 unselected pregnancies, resulting in severe thrombocytopenia in 1:1,200. HPA-1a and HLA-DRB3*0101 typing combined with anti-HPA-1a titration allows selection of the majority of pregnancies at risk of severe thrombocytopenia.

Abortion, Spontaneous↗