Search PubMed⌕ Search

Biomedical subjects

L M Smith

Publications and source records attributed to L M Smith.

260 records · Page 15Linked to original sources

Force enhancement of skeletal muscle used for dynamic cardiomyoplasty and as a skeletal muscle ventricle.

Some patients with pre end-stage congestive heart disease do not receive a significant hemodynamic benefit from dynamic cardiomyoplasty because, during prolonged preoperative immobilization, their latissimus dorsi muscle (LDM) becomes extremely weak. It is the authors' hypothesis that the local administration of an anabolic steroid into an electrically stimulated LDM will produce a thicker and stronger muscle with significant resistance to fatigue. The electrical stimulation training protocol of sheep continued for 8 weeks. For localized anabolic steroid administration an osmotic pump was placed in a subcutaneous pocket and the catheter was introduced into the LDM. The contractile force of electrically stimulated and unstimulated control muscle was studied. Control data were calculated as 100% and all other data were corrected to control. After 4 weeks there was no decrease in contractile force. The change seen was from 88 to 100% with different preloads (10, 15, and 20 g/kg) and amplitudes of impulses (5 and 10 V). After 8 weeks, the LDM was more powerful than before electrical stimulation, with a change of 97-133%. Usually after 8 weeks of electrical stimulation alone, contractile force decreases to 70-75%. During a fatigue test (30 min, 100 bursts per minute, 10-25 Hz, ripple frequency, 10 V impulse amplitude) after 4 and 8 weeks of our protocol, the LDM lost only 12% of its initial force, whereas control muscle lost 40%. Thus local anabolic steroid administration makes the LDM stronger and more useful for cardiomyoplasty.

Animals↗

Skeletal muscle of a growing organism has a greater transformation after electrical stimulation than adult skeletal muscle.

Six adult sheep and four newborn lambs (5 days old) were implanted with stimulator leads into the latissimus dorsi muscle and connected to a Myostim 7220 pacing system (Telectronics Pacing Systems, Inc., Englewood, CO). Electrical stimulation was started immediately after the operation. After 8 weeks of electrical stimulation, contractile force (CF) in adult sheep decreased to 76-81%, and to 78-82% in lambs. After 2 weeks' delay, CF in adults was 96-98%, and only 89-93% in lambs. After a 30 min intensive stress test, unconditioned control muscle lost 39% in lambs and 43% in adults. Muscle conditioned for 8 weeks lost 7-8% CF. However, after 2 weeks' delay, CF in adult muscle lost 33%, but only 12% in lambs. After cessation of electrical stimulation, the LDH-5 and LDH-1 + 2 fractions reverted to initial levels in adults, whereas in lambs, these levels continued to follow trends established during electrical stimulation. In both adults and lambs, the percent area occupied by the mitochondria increased during electrical stimulation by 6.9% in adults and 6.5% in lambs. After electrical stimulation cessation, the percent area in adults returned to baseline levels, whereas it continued to be elevated in lambs (3.3% vs 5.1%, respectively). The transformed muscle of the lamb did not revert to baseline levels after a delay period.

Adaptation, Physiological↗

Comparison of different regimens of electrical stimulation applied to nonmobilized and newly mobilized latissimus dorsi muscle.

We investigated the possibility of preventing further aggravation of muscle ischemia and necrosis in newly mobilized, unconditioned latissimus dorsi muscle (LDM) by utilizing short increments of stimulation with intervening rest periods. Adult St. Croix sheep (N = 12) weighing 30 +/- 8 kg were used in this study. Fatigue tests (30 min) using different stimulation regimens before and after LDM mobilization were performed on all animals; the length of time to return to baseline levels was also measured. Our investigation yielded results that contradict the conventional wisdom that any electrical stimulation damages newly mobilized LDM and will cause a considerable decrease in contractile force (CF). Stimulation regimens using continuous contractions at 30 and 60 contractions per minute (CPM) for 30 minutes were damaging to the LDM. CF also dropped significantly and returned slowly to baseline values: at 60 CPM, CF dropped to 50 +/- 4% and did not return to baseline even after 90 minutes of rest; at 30 CPM, CF dropped to 61 +/- 4% and baseline was restored after 80 minutes of rest. Electrical stimulation using continuous contractions at a slower rate (15 CPM) was tolerable, although a 23% decrease in CF was noted (p < 0.05 when compared to 60 CPM). These results did not satisfy us that such a regimen would be useful for cardiac assistance immediately after cardiomyoplasty. The work-rest regimen at 30 CPM also gave poor results: CF decreased to 75 +/- 2% and baseline was restored after 80 minutes of rest. Promising results were seen when utilizing a work-rest regimen at 15 CPM. The newly mobilized LDM showed no visible signs of fatigue: CF decreased minimally to 92 +/- 3% (p < 0.05 when compared to 30 CPM), and light microscopic analysis of biopsies revealed no morphological damage exceeding that typically seen after subtotal mobilization. Such results open avenues for future investigations: beginning electrical stimulation immediately after cardiomyoplasty (using a single impulse and a slow rate of contraction); decreasing the length of time necessary to obtain full cardiac assistance; and beginning partial cardiac assistance immediately after cardiomyoplasty (if needed) for approximately 30 minutes several times a day.

Animals↗

Tear histamine and histaminase during the early (EPR) and late (LPR) phases of the allergic reaction and the effects of lodoxamide.

The objectives of this study were two-fold: to identify tear histamine content and its relationship to changes in tear histaminase activity during the early (EPR) and late phases (LPR) of the allergic reaction induced by a conjunctival provocation test (CPT) and to evaluate the effects of lodoxamide on histamine release and allergic signs and symptoms during EPR and LPR. A baseline CPT was administered to 20 allergic patients with no baseline signs or symptoms of allergy. Clinical signs and symptoms were evaluated after 20 minutes and 6 hours. Tear samples were taken after 5-10 minutes and after 6 hours for subsequent analyses of cytology and histamine content (ELISA). Patients were then randomly assigned to receive lodoxamide or placebo four times daily for one week in a double-masked fashion. A second CPT was done after this therapy and the same parameters were re-evaluated. During EPR, tear histamine increased significantly with respect to baseline values (p < 0.05). During LPR, tear histamine increased significantly (p < 0.05) only in histamine inactivated samples. Histaminase enzymes were also significantly less active during the EPR (5.5 +/- 0.7) than the LPR (9.9 +/- 2.3) and at baseline. Histamine levels significantly correlated with allergic signs and symptoms (p < 0.05) only during the EPR. Lodoxamide significantly reduced histamine release during EPR (p < 0.05), allergic signs and symptoms during both EPR (p < 0.001) and LPR (p < 0.005), and tear cytology counts during LPR. In conclusion, greater histaminase activity may account for the smaller amount of tear histamine generally found during LPR, while these enzymes seem to play less of a role during the surge of histamine release and activity in the EPR. Lodoxamide was shown to ideally inhibit various aspects of the allergic reaction: clinical signs and symptoms in both the early and late phases, the primarily EPR-related peak of histamine release, and the primarily LPR-related changes in tear cytology.

Administration, Topical↗

Application of a new nuclear scintigraphy camera to evaluate flow and mechanical pumping of artificial hearts.

To assist in the development of an artificial blood pump, The Milwaukee Heart (MH-1), a new nuclear scintigraphy camera was used to study the wash-in and wash-out patterns of the MH-1. These studies indicate the MH-1 has an ejection fraction of 59.3%, with a stroke volume of 72 +/- 3 ml, and an afterload of 130 mmHg. Flow through the device is highly uniform, with no areas of stagnation. Regional ejection fraction images demonstrate homogeneous ejection from apex to base. The ability to scan through the first pass images allows study of wash-in, mixing, and wash-out of the tracer. In conclusion, this technique may provide a new approach to evaluating artificial heart pumps.

Blood Flow Velocity↗

Determination of monocyclic and polycyclic aromatic hydrocarbons in fish tissue.

An analytical method is presented in which fish tissue is analyzed for neutral monocyclic and polycyclic aromatic hydrocarbons (AHs) and aromatic sulfur heterocycles (ASHs) by capillary column gas chromatography (CGC) with photoionization detection. The sample enrichment procedure includes saponification with aqueous KOH, acidification of the digestates, and extraction of the aromatic compounds into cyclopentane-dichloromethane. Adsorption chromatography on tandem segments of potassium silicate and silica gel removes 99% of the coextracted lipid. Final enrichment by gel permeation chromatography eliminates residual biogenic material and potentially interfering alkanes. Relatively volatile monoaromatics are included among the analytes by virtue of the efficiency of the complementary enrichment steps, the use of small quantities of only low-boiling solvents, and the selectivity of the detector. Most targeted compounds (AHs ranging in size from C3-alkylbenzenes through benzo[g,h,l]perylene and ASHs within the same size range) can be determined in 5 g (wet weight) samples of fish tissue at concentrations as low as 20 ng/g. Comparisons are made of recoveries of selected AHs under ordinary and gold fluorescent lighting conditions.

Adsorption↗

Determination of fluorene in fish, sediment, and plants.

Methods and their applications are described for the determination of fluorene in fish, sediment, and plants. Sample extracts are enriched by using 2 or more of the following: gel permeation, silica gel, potassium silicate, sulfuric acid-impregnated silica gel, and activated carbon. Efficiency was improved by applying the adsorbents in combination or as tandem enrichment modules. Analyses by liquid chromatography (LC) with ultraviolet or fluorescence detection (LC/UV or LC/F) yielded limits of detection of 30, 3, and 30 ng/g and average recoveries of 80, 81, and 74% for fish, sediment, and plants, respectively.

Animals↗