Search PubMed⌕ Search

Biomedical subjects

L M Porfiri

Publications and source records attributed to L M Porfiri.

13 recordsLinked to original sources

NMR exposure sensitizes tumor cells to apoptosis.

NMR technology has dramatically contributed to the revolution of image diagnostic. NMR apparatuses use combinations of microwaves over a homogeneous strong (1 Tesla) static magnetic field. We had previously shown that low intensity (0.3-66 mT) static magnetic fields deeply affect apoptosis in a Ca2+ dependent fashion (Fanelli et al., 1999 FASEBJ., 13;95-102). The rationale of the present study is to examine whether exposure to the static magnetic fields of NMR can affect apoptosis induced on reporter tumor cells of haematopoietic origin. The impressive result was the strong increase (1.8-2.5 fold) of damage-induced apoptosis by NMR. This potentiation is due to cytosolic Ca2+ overload consequent to NMR-promoted Ca2+ influx, since it is prevented by intracellular (BAPTA-AM) and extracellular (EGTA) Ca2+ chelation or by inhibition of plasma membrane L-type Ca2+ channels. Three-days follow up of treated cultures shows that NMR decrease long term cell survival, thus increasing the efficiency of cytocidal treatments. Importantly, mononuclear white blood cells are not sensitised to apoptosis by NMR, showing that NMR may increase the differential cytotoxicity of antitumor drugs on tumor vs normal cells. This strong, differential potentiating effect of NMR on tumor cell apoptosis may have important implications, being in fact a possible adjuvant for antitumor therapies.

Apoptosis↗

Sonohysterography: is the hysterosalpingographic vacuum cup a valid alternative device for cannulation of the cervical Os?

PURPOSE: To determine whether sonohysterography (SHG) should be performed with Plexiglas hysterosalpingographic vacuum cups instead of standard catheters. MATERIALS AND METHODS: In a prospective setting, 226 women randomly classified into 2 groups underwent SHG. The method used for cervical cannulation was a two-way catheter in the first group (n = 108) and a Plexiglas hysterosalpingographic vacuum cup in the second one (n = 118). Diagnostic reliability, easy applicability for the physician, discomfort for the patients and cost of the instruments were assessed for both devices. RESULTS: 226/226 (100 %) complete sonohysterographic examinations were performed. As regards uterine cavity distension the same diagnostic reliability was reported for vacuum cups and two-way catheters. The standard catheter obscured the cervical canal because of the dilation of the balloon. Both methods were judged as easy to use, and no statistically significant difference was found as far as the time required for cervical cannulation (p > 0.05). A little more discomfort was recorded by women who underwent sonohysterography with standard balloon catheters but a greater interpersonal variability was noticed in this group (SD 3.65 vs. 1.13 in the vacuum cup group). Vacuum cups were by far the most economical devices (unit cost: 16.70 euro vs. catheter unit cost 46.20 euro). CONCLUSION: Vacuum cups allow sonohysterography to be correctly performed. As they are inexpensive, easy to use, better tolerated by the patients and more helpful for visualisation of the lower third of the uterine cavity, vacuum cups should be considered a serious alternative to standard catheters in the performance of SHG.

Adult↗

[Effects of hormonal replacement therapy on breast density in postmenopausal women].

AIM: Recent studies have indicated that conventional hormonal replacement therapy (HRT) is associated with an increase in breast density. The aim of this non randomised prospective study was to evaluate the effects of HRT and Tibolone on breast density in postmenopausal women. METHODS: The study population included 41 healthy women, who were on different HRT regimens and completed their 5-year mammographic follow-up. Before starting HRT, a baseline mammography was performed and repeated at 12-month interval during the follow-up. The patients, 41 healthy postmenopausal women, received 2 different treatments: continuous transdermal estrogen 50 microg/day plus sequential MPA 10 mg/day for 12 days at cycle (21 patients), Tibolone 2.5 mg/day (20 patients). RESULTS: An increase in breast density was present in 25% of women receiving estrogen plus MPA. There was no mammographic breast density increase in Tibolone group; 9.5% of women receiving Tibolone showed reduced breast density. The modifications of breast density were reported during the 1st year of therapy. CONCLUSION: These findings show that different HRT regimens have different effects on breast density. Tibolone does not significantly affect breast density, so it may be a preferable therapy for a larger group of postmenopausal women, including those with a familiar history of breast cancer and those with breast density.

Breast↗

High-resolution scintimammography improves the accuracy of technetium-99m methoxyisobutylisonitrile scintimammography: use of a new dedicated gamma camera.

The main disadvantage of technetium-99m methoxyisobutylisonitrile (MIBI) prone scintimammography is its limited sensitivity for T1a and T1b cancers with a size of less than 1 cm. We have developed a high-resolution scintimammographic technique using a gamma camera based on a new concept, namely a position-sensitive photo-multiplier tube. The field of view of this camera, previously known as the SPEM (single photon emission mammography) camera, was 10 cm diameter. Scintimammographic images were acquired in the axial view; each breast was compressed to a thickness of 3-6 cm, modal class 4 cm. When the compressed breast was larger than the field of view, more than one study was performed in order to image the entire gland. Fifty-three patients were studied with high-resolution-scintimammography (HRSM) and Anger camera prone scintimammography (ACPSM). HRSM was performed 70 min after i.v. administration of 740 Mbq of (99m)Tc-MIBI; ACPSM images were acquired 10 and 60 min following the injection. Early 10-min ACPSM images were only evaluated for routine diagnostic purposes, while comparison was carried out between the 60-min ACPSM and 70-min HRSM images. At fine-needle aspiration (FNA) and/or open biopsy, 31 patients showed cancer: 15 T1c, 11 T1b and 5 T1a. In T1a-T1b cancers, the sensitivity of scintimammography was 50% with ACPSM and 81.2% with HRSM (P<0.01). Specificity was 86% with both techniques. HRSM is a promising new technique that improves the sensitivity of (99m)Tc-MIBI scintimammography in tumours sized less than 1 cm without apparently reducing its specificity. We are now working on a larger field-of-view camera.

Aged↗

[A mammographic evaluation of the morphostructural variations of the breast during hormone-replacement therapy in the postmenopause].

INTRODUCTION: Exogenous hormones may cause breast tissue changes, generally increasing its density. We used mammography to detect the to early effects of hormone replacement therapy in postmenopausal women. MATERIAL AND METHODS: We examined 300 postmenopausal women (group A: 70 women in surgical menopause treated with estrogen replacement therapy; group B: 230 women in spontaneous menopause receiving estrogen and progestin replacement therapy). The mammographic patterns, according to Wolfe's classification, were compared with those of group C (case control group of 300 women) and group X after 1 year of therapy. The modification were classified as total and partial changes in mammographic density. The results were analyzed with Pearson's chi 2 test. RESULTS: The evidence of a change in parenchymal pattern was found in 103/300 women (34.3%). Twenty-one women in group A and 82 in group B showed increased mammographic density (the DY breast by Wolfe). Partial changes were observed in 64 cases (21.3%). Comparing groups A and B to groups C and X (before therapy), the changes were statistically significant (p < .001), while comparing groups A and B the difference was not significant (p = 1.000). CONCLUSIONS: The likely widespread use of hormone replacement therapy in the future will require an increase in the number of mammograms and a possible re-evaluation of sensitivity. To improve follow-up timing and to avoid a decrease in sensitivity, radiologists will have to consider both general and specific factors and to pay attention to the patterns of global increase in breast tissue density, the DY pattern of Wolfe's classification.

Breast↗

Hysterosalpingographic abnormalities in infertile women: radiological and clinical interpretation.

A review of 1035 hysterosalpingographies (HSG) has shown a frequency of acquired and congenital morphological alteration in 272 patients with spontaneous abortion and in 763 infertile couples. The frequency of congenital anomalies was 25.5% in spontaneous abortions and 5.3% in infertility. Acquired morphological anomalies were 11.7% in spontaneous abortion and 34.6% in infertility. Tubal problems represent 25% of lesions in infertility. Furthermore couples have been studied by correlating the male factor i.e. the sperm quality to various types of morphological anomalies observed in order to better evaluate the actual damage evidence by HSG.

Abortion, Spontaneous↗

99mTc-MIBI prone scintimammography in patients with high and intermediate risk mammography.

Mammographic lesions can be classified into categories of high (HR), intermediate (IR) and low risk of breast cancer. We have performed 99mTc MIBI scintimammography on 85 patients with high or intermediate risk lesions in order to verify its ability to diagnose cancer before biopsy. The scintimammography was performed in prone lateral view; all the patients were submitted to excisional biopsy. HR lesions showed 86% of cancers and scintigraphic accuracy of 0.81. The accuracy of scintimammography was 0.97 in lesions larger than 1 cm. IR lesions showed 47% of cancer with scintigraphic accuracy of 0.95. The scintigraphic sensitivity was 0.97 lesions larger than and 0.50 in lesion smaller than 1 cm, whereas the specificity was always about 90%. Our results suggest that scintimammography can substantially decrease the need of biopsy for breast cancer diagnosis.

Adult↗

[Breast scintigraphy with 99mTc-MIBI in the study of breast cancer].

BACKGROUND: The literature latest data point out the 99mTc-MIBI scintimammography role as a mammography diagnostic complement for a better nosologic definition of the breast nodular pathology. The object of this study is to evaluate the device sensibility and specificity with reference to the several dimensions of the neoplastic nodule. METHODS: A group of 50 patients, with breast nodule has been studied comparing scintimammography, mammography, echography and istological examination of the removed nodule. RESULTS: 38 nodules out of 50 were carcinomas, 22 were T1 and 16 T2. As far as scintimammography is concerned, the sensibility is 86% in T1 grade and 100% in T2 grade. The specificity is 91.6%. CONCLUSIONS: Since the mammography often need integration with invasive examinations, (aspiration biopsy, and biopsy) scintigraphy-mammography, global specificity 92%, is suggested as a second level examination in the mammary nodule diagnosis, for the simple performance and for the little risk for the patient.

Biopsy↗

[Assessment of radiation dose to patients in hysterosalpingography].

INTRODUCTION: The optimization principle applied to the patient radioprotection, recently introduced in Italian legislation, requires a careful analysis of the working procedures and clinical protocols generally used in radiological practice, to avoid unnecessary exposures with no loss in diagnostic information. We carried out this analysis in hysterosalpingography, which is the radiological examination usually performed on fertile women to detect uterine and tubal conditions. MATERIALS AND METHODS: The dosimetric survey was carried out on 35 patients, 22 to 40 years old, to evaluate: a) entrance dose and dose x area product; b) doses to the most irradiated organs, that is ovaries and uterus; c) effective dose equivalent and effective dose. The doses were measured with LiF thermoluminescent dosimeters, while an ionization chamber enabled us to the calculate dose area product. Ovaries and uterus doses were calculated with a Monte Carlo program using skin entrance exposure data and some technical parameters of the examination. RESULTS: The good agreement of the results obtained with both dosimetric methods demonstrated their equivalence in this specific case where the use of a clinical protocol, with no lateral projection, made the dosimeters lie always within the X-ray beam. DISCUSSION AND CONCLUSIONS: The mean dose was 4.5 mGy for the ovaries and 6.2 mGy for the uterus. Following the recommendations of the International Commission on Radiological Protection, both effective dose equivalent, with a mean value of 2.0 mSv, and effective dose, with a mean value of 1.95 mSv, were estimated. In conclusion, our results show that the patient dose can be reduced by limiting the use of fluoroscopy, using small size films and decreasing the number of exposures.

Adult↗