Search PubMed⌕ Search

Biomedical subjects

L Lidgren

Publications and source records attributed to L Lidgren.

At least 19 recordsLinked to original sources

The effect of crystallinity on strength development of alpha-TCP bone substitutes.

Alpha phase tricalcium phosphates (alpha-TCP) were produced using a solid-state reaction method and milled for various periods of time. The resulting four materials were alpha-TCPs, ranging in crystalline content. Powders were exposed to X-ray diffraction for material identification as well as for use in crystallinity and purity calculations. Powder particle size was investigated using laser diffraction. Materials were mixed with 2.5% Na(2)HPO(4) solution to initiate the hydration of alpha-TCP to calcium-deficient hydroxyapatite (CDHA). Isothermal calorimetry was performed to observe thermal response of the powders over a period of time. During the reaction process, at various time points up to 216 h, the material was compression tested to observe strength development. Materials proved to be predominantly alpha phase, while amorphous content determined by XRD varied. Reactivity, as measured by isothermal calorimetry, varied with crystallinity of the alpha-TCP powder. Speed of strength development did not change except for the most finely ground powder. In addition, crystal size of the CDHA was changed only in the product formed from the most highly ground material. It is proposed that increasing reactivity of alpha-TCP cements does not result in a corresponding increase in rate of strength development until there is sufficient supersaturation to produce significant crystal nucleation.

Bone Substitutes↗

In vitro and in vivo biological responses to a novel radiopacifying agent for bone cement.

Iodixanol (IDX) and iohexol (IHX) have been investigated as possible radiopacification agents for polymethylmethacrylate (PMMA) bone cement, to replace the currently used barium sulphate and zirconia. IDX and IHX are both water-soluble iodine-based contrast media and for the last 20 years have been used extensively in clinical diagnostic procedures such as contrast media enhanced computed tomography, angiography and urography. One of the major reasons to remove the current radiopacifying agents is their well-documented cytotoxicity and their potential to increase bone resorption. Using in vitro bone resorption assays, the effect of PMMA particles plus IDX or IHX to induce osteoclast formation and lacunar resorption on dentine slices has been investigated. These responses have been compared with the in vitro response to PMMA particles containing the conventional radiopacifying agents, that is, barium sulphate and zirconia. In parallel, the in vivo reaction, in terms of new bone formation, to particles of these materials has been tested using a bone harvest chamber in rabbit tibiae. In vitro cell culture showed that PMMA containing IHX resulted in significantly less bone resorption than PMMA containing the conventional opacifiers. In vivo testing, however, showed no significant differences between the amounts of new bone formed around cement samples containing the two iodine-based opacifying agents in particulate form, although both led to fewer inflammatory cells than particles of PMMA containing zirconia. Our results suggest that a non-ionic radiopacifier could be considered as an alternative to the conventional radiopacifying agents used in biomaterials in orthopaedic surgery.

Animals↗

Water uptake and release from iodine-containing bone cement.

Water uptake and release characteristics of PMMA cement containing the water-soluble contrast media iohexol or iodixanol have been investigated. The water uptake study revealed that iohexol had the highest uptake of water (3.7%) and that iodixanol had an uptake close to that of Palacos R (2.3% and 1.9%). The curves obtained showed the materials to follow classic diffusion theory, with an initial linearity with respect to t(1/2) making it possible to calculate the diffusion coefficients. This showed iohexol to have the lowest diffusion coefficient, Palacos R the highest, and iodixanol close to that of Palacos R. The release study showed that more iohexol than iodixanol was released from the bone cement; the long-term release was above 25 microg/mL for iohexol compared to slightly above 10 microg/mL for iodixanol. A microCT investigation showed that the risk of developing an observable radiolucent zone is negligible.

Absorption↗

Bone cement X-ray contrast media: a clinically relevant method of measuring their efficacy.

It is important to compare different contrast media used in bone cement according to their ability to attenuate X-rays and thereby produce image contrast between bone cement and its surroundings in clinical applications. The radiopacity of bone cement is often evaluated by making radiographs of cement in air at an X-ray tube voltage of 40 kV. We have developed a method for ranking contrast media in bone cement simulating the clinical situation, by (1) choosing the same X-ray tube voltage as used in clinical work, and (2) using a water phantom to imitate the effects of the patients' soft tissue on the X-ray photons. In clinical work it is desirable to have low radiation dose, but high image contrast. The voltage chosen is a compromise, because both dose and image contrast decrease with higher voltage. Three contrast media (ZrO(2), BaSO(4), and Iodixanol) have been compared for degree of "image contrast." Comparing 10 wt % contrast media samples at an X-ray tube voltage of 40 kV, ZrO(2) produced higher image contrast than the other media. However, at 80 kV, using a water phantom, the results were reversed, ZrO(2) produced lower image contrast than both BaSO(4) and Iodixanol. We conclude that evaluations of contrast media should be made with voltages and phantoms imitating the clinical application.

Barium Sulfate↗

Biodegradation and biocompatability of a calcium sulphate-hydroxyapatite bone substitute.

An injectable material consisting of calcium sulphate mixed with hydroxyapatite was investigated as a possible alternative to autograft in the restoration of bone defects. The material was studied both in vitro in simulated body fluid (SBF) and in vivo when implanted in rat muscles and into the proximal tibiae of rabbits. Variation in the strength and weight of the material during ageing in SBF was measured. Tissue response, material resorption and bone ingrowth were studied in the animal models. A good tissue response was observed in both the rat muscles and rabbit tibiae without inflammatory reactions or the presence of fibrous tissue. Ageing in SBF showed that during the first week carbonated hydroxyapatite precipitated on the surfaces of the material and this may enhance bone ingrowth.

Animals↗

Factors influencing the compressive strength of an injectable calcium sulfate-hydroxyapatite cement.

A biphasic injectable bone substitute, suitable for filling bone defects, that sets in the body, based on calcium sulfate and hydroxyapatite (HA), is presented. For applications in bone defects the compressive strength is important to assure support of the defect site during loading when the patient is weight bearing. To control the strength, the influence of four different factors; the liquid-to-powder (L/P) ratio, the HA particle morphology, the HA content and the amount of accelerator, were investigated. alpha-Calcium sulfate hemihydrate (CSH) and four different HA powders (three sintered and one spray-dried) were used. All differed in size and morphology. CSH and each HA powder were mixed together with distilled water to form the bone substitute. An accelerator, in form of calcium sulfate dihydrate, was added to the powder phase to obtain an adequate setting time. Cylindrical specimens were compression tested. A lower L/P-ratio gave stronger cement, but was more difficult to inject. The shape and the morphology of the HA particles influenced the strength, and reducing the amount of HA increased the strength. The amount of accelerator (calcium sulfate dihydrate) had no influence.

Journal Article↗

Characterization of a novel calcium phosphate/sulphate bone cement.

Apatitic cements have shown excellent biocompatibility and adequate mechanical properties but have slow resorption in the human body. To assure that new bone tissue grows into the bone defect, a certain porosity is necessary although hard to achieve in injectable cements with suitable mechanical properties. An attempt was made by mixing alpha-tricalcium phosphate (alpha-TCP), calcium sulphate hemihydrate (CSH) and an aqueous solution containing 2.5 wt% of Na(2)HPO(4). The aim was to obtain a material containing two phases: a) one apatitic phase (calcium-deficient hydroxyapatite; CDHA) and b) one resorbable phase (calcium sulphate dihydrate; CSD). alpha-TCP and CSH mixtures were produced at relative intervals of 20 wt%. The liquid-to-powder (L/P) ratio to obtain a paste was 0.32 mLg(-1). The highest compressive strength (34 MPa) was obtained for the pure alpha-TCP sample. The strength was, in a first approximation, directly correlated to the weight proportions of the powders. X-ray diffraction analysis showed that the relative intensity for CDHA increased linearly, and the one for CSD decreased exponentially, when the amount of alpha-TCP increased. Thus, CSH ceased to transform to CSD when the amount of alpha-TCP increased. Observations in environmental scanning electron microscopy confirmed the X-ray diffraction results. CSH-crystals (100 microm) were embedded in the HA-matrix permitting gradual porosity in the material when resorbed.

Biocompatible Materials↗

Roentgen single-plane photogrammetric analysis (RSPA.) A new approach to the study of musculoskeletal movement.

We present a new approach for the accurate reconstruction of three-dimensional skeletal positions using roentgen single-plane photogrammetric analysis (RSPA). This technique uses a minimum of three markers embedded in each segment which allow continuous, real-time, internal skeletal movement to be measured from single-plane images, provided that the precise distance between the markers is known. A simulation study indicated that the error propagation in this approach is influenced by focus position, object position, the number of control points, the accuracy of the previous measurement of the distance between markers and the accuracy of image measurement. For reconstruction of normal movement of the knee with an input measurement error of SD = 0.02 mm, the rotational and translational differences between reconstructed and original movement were less than 0.27 degrees and 0.9 mm, respectively. Our results showed that the accuracy of RSPA is sufficient for the analysis of most movement of joints. This approach can be applied in combination with force measurements for dynamic studies of the musculoskeletal system.

Computer Simulation↗

Contamination of polyethylene cups with polymethyl methacrylate particles: an experimental study.

The articulating surfaces of 6 ultra-high molecular weight polyethylene cups were exposed to curing polymethyl methacrylate (PMMA) bone-cement and examined with scanning electron microscopy and laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS). Three of the cups were exposed to blood and bone-cement, and the rest were exposed to bone-cement only. After removal of the bone-cement bulk, PMMA particles were found and identified in all 6 cups. The particles were verified by identifying zirconium with energy-dispersive x-ray fluorescence spectroscopy in 5 cups and with LA-ICPMS in 1 cup. The degree of surface contamination was estimated with LA-ICPMS. The number of zirconium-containing particles detected was on average 10 to 20/mm2. PMMA bone-cement left in polyethylene cups during polymerization can contaminate the articulating surface with adherent PMMA particles.

Bone Cements↗

The Swedish Knee Arthroplasty Register 1975-1997: an update with special emphasis on 41,223 knees operated on in 1988-1997.

From 1975, when the Swedish Knee Arthroplasty Register (SKAR) started, until the end of 1997, 57,533 primary arthroplasties and revisions have been registered. Recently, the register underwent a comprehensive validation and update regarding revisions. We now report on general demographic and epidemiological data for the whole period and on the survivorship of arthroplasties performed in Sweden during 1988-1997. During this 10-year period, 41,223 primary knee arthroplasties were performed on 34,877 patients. We found, as in our earlier reports, that survivorship was affected by patient-, time-, implant- and method-related factors but, apart from an overall higher cumulative revision rate, general conclusions reported from the register in recent years appeared to be unaffected.

Aged↗

The routine of surgical management reduces failure after unicompartmental knee arthroplasty.

A total of 10,474 unicompartmental knee arthroplasties was performed for medial osteoarthritis in Sweden between 1986 and 1995. We sought to establish whether the number of operations performed in an orthopaedic unit affected the incidence of revision. Three different implants were analysed: one with a high revision rate, known to have unfavourable mechanical and design properties; a prosthesis which is technically demanding with a known increased rate of revision; and the most commonly used unicompartmental device. Most of the units performed relatively few unicompartmental knee arthroplasties per year and there was an association between the mean number carried out and the risk of later revision. The effect of the mean number of operations per year on the risk of revision varied. The technically demanding implant was most affected, that most commonly used less so, and the outcome of the unfavourable design was not influenced by the number of operations performed. For unicompartmental arthroplasty, the long-term results are related to the number performed by the unit, probably expressing the standards of management in selecting the patients and performing the operation.

Aged↗

Appropriate questionnaires for knee arthroplasty. Results of a survey of 3600 patients from The Swedish Knee Arthroplasty Registry.

The Swedish Knee Arthroplasty Registry (SKAR) has recorded knee arthroplasties prospectively in Sweden since 1975. The only outcome measure available to date has been revision status. While questionnaires on health outcome may function as more comprehensive endpoints, it is unclear which are the most appropriate. We tested various outcome questionnaires in order to determine which is the best for patients who have had knee arthroplasty as applied in a cross-sectional, discriminative, postal survey. Four general health questionnaires (NHP, SF-12, SF-36 and SIP) and three disease/site-specific questionnaires (Lequesne, Oxford-12, and WOMAC) were tested on 3600 patients randomly selected from the SKAR. Differences were found between questionnaires in response rate, time required for completion, the need for assistance, the efficiency of completion, the validity of the content and the reliability. The mean overall ranks for each questionnaire were generated. The SF-12 ranked the best for the general health, and the Oxford-12 for the disease/site-specific questionnaires. These two questionnaires could therefore be recommended as the most appropriate for use with a large knee arthroplasty database in a cross-sectional population.

Aged↗

Past incidence and future demand for knee arthroplasty in Sweden: a report from the Swedish Knee Arthroplasty Register regarding the effect of past and future population changes on the number of arthroplasties performed.

By combining data from the Swedish Knee Arthroplasty Register and Swedish census registers we have calculated the past age-specific incidence of primary knee arthroplasties and predicted the demand. During the last 20 years, osteoarthrosis has accounted for the largest increase in number of knee arthroplasties while operations for rheumatoid arthritis remained constant. The mean yearly number of operations between the periods 1976-1980 and 1996-1997 increased more than five-fold, while only 6% of that increase could be explained by changes in the age-profile of the population. Most operations were performed on persons of 65 years and older who also had the largest increase in incidence. By using the incidences for 1996 and 1997 and taking into account the expected future changes in the age profile of the Swedish population, we estimate that, in the absence of an effective preventive treatment, the number of knee arthroplasties will increase by at least one third until 2030.

Age Distribution↗

Patient satisfaction after knee arthroplasty: a report on 27,372 knees operated on between 1981 and 1995 in Sweden.

During a validation process of the Swedish Knee Arthroplasty Register (SKAR), living registered patients were sent a questionnaire to ask if they had been reoperated on. This gave an opportunity to pose a simple four-point question with respect to patient satisfaction which 95% of patients answered. We analyzed the answers of patients operated on between 1981 and 1995 and found that only 8% of the patients were dissatisfied regarding their knee arthroplasty 2-17 years postoperatively. The satisfaction rate was constant, regardless of when the operation had been performed during the 15-year period. The proportion of satisfied patients was affected by the preoperative diagnosis, patients operated on for a long-standing disease more often being satisfied than those with a short disease-duration. There was no difference in proportions of satisfied patients, whether they had primarily been operated on with a total knee arthroplasty (TKA) or a medial unicompartmental arthroplasty (UKA). For TKAs performed with primary patellar resurfacing, there was a higher ratio of satisfied patients than for TKAs not resurfaced, but this increased ratio diminished with time passed since the primary operation. Unrevised knees had a higher proportion of satisfied patients than knees that had been subject to revision, and among patients revised for medial UKA, the proportion of satisfied patients was higher than among patients revised for TKA. We conclude that satisfaction after knee arthroplasty is stable and long-lasting in unrevised cases and that even after revision most patients are satisfied.

Arthroplasty, Replacement, Knee↗

Translation and validation of the Oxford-12 item knee score for use in Sweden.

The Oxford-12 Item Knee Score is a recently developed and validated patient-completed outcome measure designed specifically for use with knee arthroplasty in the United Kingdom. We have translated this questionnaire into Swedish and tested the validity and reliability of the translated version in a cross-sectional study by a postal survey to 1,200 randomly selected patients from the Swedish Knee Arthroplasty Register. Swedish versions of the WOMAC, Nottingham Health Profile, SF-36, SF-12, and the Sickness Impact Profile were employed in the validation process. We also tested feasibility and patient-burden parameters. The translated version appeared to be linguistically and culturally equivalent to the original version with good validity and reliability. Indirect measures of responsiveness indicated that it is at least as responsive to relevant knee arthroplasty patient states as the previously validated Swedish version of the WOMAC. Application of the translated questionnaire to this population is feasible with minimal imposed patient-burden. The Swedish translation of the Oxford-12 Item Knee Score is a valid and reliable tool for outcome studies on knee arthroplasty patients.

Aged↗