Identification of EEG events in the MR scanner: the problem of pulse artifact and a method for its subtraction.

Triggering functional MRI (fMRI) image acquisition immediately after an EEG event can provide information on the location of the event generator. However, EEG artifact associated with pulsatile blood flow in a subject inside the scanner may obscure EEG events. This pulse artifact (PA) has been widely recognized as a significant problem, although its characteristics are unpredictable. We have investigated the amplitude, distribution on the scalp, and frequency of occurrence of this artifact. This showed large interindividual variations in amplitude, although PA is normally largest in the frontal region. In five of six subjects, PA was greater than 50 microV in at least one of the temporal, parasagittal, and central channels analyzed. Therefore, we developed and validated a method for removing PA. This subtracts an averaged PA waveform calculated for each electrode during the previous 10 s. Particular attention has been given to reliable ECG peak detection and ensuring that the average PA waveform is free of other EEG artifacts. Comparison of frequency spectra for EEG recorded outside and inside the scanner, with and without PA subtraction, showed a clear reduction in artifact after PA subtraction for all four frequency ranges analyzed. As further validation, lateralized epileptiform spikes were added to recordings from inside and outside the scanner: PA subtraction significantly increased the proportion of these spikes that were correctly identified and decreased the number of false spike detections. We conclude that in some subjects, EEG/fMRI studies will be feasible only using PA subtraction.

Adult↗

The detection and significance of subtle changes in mixed-signal brain lesions by serial MRI scan matching and spatial normalization.

The purpose of this work is to detect and assess the significance of subtle signal changes in mixed-signal lesions based on serial MRI scan matching. Pairs of serially acquired T1-weighted volume MR images from 20 normal controls and seven patients with epilepsy were matched and difference images obtained. The precision and consistency of the registration were evaluated. The Gaussian noise level in the difference images was determined automatically. A structured difference filter was then used to segment structured (changed) voxels from the Gaussian noise. In the controls, the structured difference images were normalized into Talairach space, resulting in a structured noise map. The significance of changes in patients was assessed by spatial normalization and comparison with the structured noise map. The precision and consistency of the co-registration were < or = 0.06 mm with a registration success rate of 100%. The Gaussian noise level in the difference images was in the range 3.0-6.9. In the controls, an average of 1.6% of the brain voxels were classified as structured. Sine-based registration resulted in a reduction of < 1% in the amount of structure compared to linear interpolation. The structured noise map in controls showed high noise density in areas affected by image artefacts. We show examples of significant changes found in lesions which had been reported as unchanged on visual inspection. A novel quantitative approach has been presented for the detection and quantification of subtle signal changes in lesions. This method is of potential clinical value in the non-invasive characterization of signal change and biological behaviour of neoplastic lesions.

Adult↗

Identifying homologous anatomical landmarks on reconstructed magnetic resonance images of the human cerebral cortical surface.

Guided by a review of the anatomical literature, 36 sulci on the human cerebral cortical surface were designated as homologous. These sulci were assessed for visibility on 3-dimensional images reconstructed from magnetic resonance imaging scans of the brains of 20 normal volunteers by 2 independent observers. Those sulci that were found to be reproducibly identifiable were used to define 24 landmarks around the cortical surface. The interobserver and intraobserver variabilities of measurement of the 24 landmarks were calculated. These reliably reproducible landmarks can be used for detailed morphometric analysis, and may prove helpful in the analysis of suspected cerebral cortical structured abnormalities in patients with such conditions as epilepsy.

Anatomy, Regional↗

Measurement of small inter-scan fluctuations in voxel dimensions in magnetic resonance images using registration.

We present a method to estimate fluctuations in voxel dimensions in MR images. In the proposed method images of a standard test object are acquired serially and registered to an initial dataset. We present the results of experiments where changes in voxel dimensions between 0.1% and 2% were prescribed and measured with an accuracy of 0.02%. The method can be integrated as part of a standard MRI Quality Assurance program and may also be useful to correct for inter-scan variability introduced by fluctuations in gradient performance.

Biophysical Phenomena↗

Recording of EEG during fMRI experiments: patient safety.

The acquisition of electroencephalograms (EEG) during functional magnetic resonance imaging (fMRI) experiments raises important practical issues of patient safety. The presence of electrical wires connected to the patient in rapidly changing magnetic fields results in currents flowing through the patient due to induced electromotive forces (EMF), by three possible mechanisms: fixed loop in rapidly changing gradient fields; fixed loop in a RF electromagnetic field; moving loop in the static magnetic field. RF-induced EMFs were identified as the most important potential hazard. We calculated the minimum value of current-limiting resistance to be fitted in each EEG electrode lead for a representative worst case loop, and measured RF magnetic field intensity and heating in a specific type of current-limiting resistors. The results show that electrode resistance should be > or = 13 k(omega) for our setup. The methodology presented is general and can be useful for other centers.

Electroencephalography↗

Development of hippocampal atrophy: a serial magnetic resonance imaging study in a patient who developed epilepsy after generalized status epilepticus.

PURPOSE: To investigate changes in hippocampal volume. METHODS: We used serial magnetic resonance imaging (MRI) in a patient who developed chronic epilepsy after having generalized tonic-clonic status epilepticus (SE). Five MRI investigations were performed during SE and a 58-month follow-up period. Hippocampal volumetric measurements and coregistration of scans were performed to detect hippocampal atrophy. RESULTS: During status both mesiotemporal regions returned a high signal on T2-weighted images. Two months after the onset of SE, bilateral hippocampal atrophy was detected. Further progressive hippocampal atrophy was detected in the subsequent 58 months by both hippocampal volumetric measurements and coregistration of scans. CONCLUSIONS: Our findings suggest that hippocampal atrophy is a process that may continue after the end of the SE.

Adult↗

Calculation of electrical potentials on the surface of a realistic head model by finite differences.

We present a method for the calculation of electrical potentials at the surface of realistic head models from a point dipole generator based on a 3D finite-difference algorithm. The model was validated by comparing calculated values with those obtained algebraically for a three-shell spherical model. For a 1.25 mm cubic grid size, the mean error was 4.9% for a superficial dipole (3.75 mm from the inner surface of the skull) pointing in the radial direction. The effect of generator discretization and node spacing on the accuracy of the model was studied. Three values of the node spacing were considered: 1, 1.25 and 1.5 mm. The mean relative errors were 4.2, 6.3 and 9.3% respectively. The quality of the approximation of a point dipole by an array of nodes in a spherical neighbourhood did not depend significantly on the number of nodes used. The application of the method to a conduction model derived from MRI data is demonstrated.

Brain↗

Effect of fiducial marker localization on stereotactic target coordinate calculation in CT slices and radiographs.

Novel methods are presented which allow the estimation of the effect of stereotactic fiducial marker localization on target localization in a stereotactic surgery planning program based on the integration of image data from various modalities. The results of simulations are presented. A method for the evaluation of the effect of fiducial marker localization error on stereotactic localization, both for computed tomography (CT) and digitized radiography. Is proposed based on perturbation studies. For tomographic data, the comparison of the stability of two types of fiducial localizers: a standard commercial device based on nine (six vertical and three oblique) rods and an imaginary system with an extra set of rods, called '4-N', is discussed. Results of the perturbation studies clearly indicate the necessity of sub-pixel registration of the fiducial markers in CT. On the other hand, results demonstrate that stereotactic localization based on projection images is less sensitive to fiducial localization error than CT. Finally, the authors present an algorithm for the localization of fiducial markers to sub-pixel accuracy in radiographs acquired with a commercial angio localizer.

Algorithms↗

Simple method of purification and sequencing of a bacteriocin produced by Pediococcus acidilactici UL5.

A bacteriocin produced by a strain of Pediococcus acidilactici was successfully purified sequentially by acid extraction (at pH 2) and reverse-phase high-performance liquid chromatography (HPLC). Cell extracts of derivative strains deficient in bacteriocin production exhibited a similar HPLC elution profile to the active extracts except for the two peaks containing bacteriocin activity. The sequence of the antibacterial peptide consisted of 44 amino acid residues of which 42 were identified, and its molecular weight was 4624 Da, as determined by mass spectrometry. Moreover, according to the molecular weight of the peptide, the unidentified residues in the bacteriocin sequence must correspond to two tryptophan residues, confirming that the peptide isolated from Ped. acidilactici UL5 is pediocin PA-1. However, oxidized forms of the bacteriocin produced during storage also showed bacteriocin activity and resulted in a second peak with activity in the chromatograms. HPLC chromatograms of cell surface preparations from the active and from the deficient strains were confirmed by capillary electrophoresis. The purification method used is simple and effective in comparison with traditional methods, permitting a selective recovery of cell-associated bacteriocin at low pH, and its isolation in pure form for sequencing.

Amino Acid Sequence↗

A patient-to-computed-tomography image registration method based on digitally reconstructed radiographs.

An automatic method for the accurate registration of computed tomography (CT) data with two camera-calibrated radiographs is presented. The registration is based on the skull as visualized both in the plain radiographs and in radiographs digitally reconstructed from CT. A reference coordinate system is established based on the radiographic projection parameters obtained using an angiographic stereotactic localizer. The CT-derived reconstructed radiographs are aligned iteratively at multiple resolutions until a best match is found by adjusting the position and orientation of the CT data set relative to the reference coordinate system. The results of experiments with a skull phantom performed under stereotactic control which show that reliable registration is possible with an accuracy better than 1 mm are presented. Possible applications include intraoperative patient-to-CT frameless registration and registration of radiographic data with frameless CT for depth electroencephalogram electrode position confirmation.

Algorithms↗

Voxel-based localization in frame-based and frameless stereotaxy and its accuracy.

The problem of accurate stereotactic localization and registration of targets in computed tomography (CT) data sets is addressed, in particular the effect of using a single transformation matrix to map voxel coordinates onto stereotactic coordinates. An algebraic approach to the calculation of stereotactic target coordinates in tomographic data acquired with conventional stereotactic localizers is presented. The volume transformation matrix (VTM) is discussed, which is useful for the registration of volumetric data sets, and also corresponds to the rigid body transformation matrix used in many so-called frameless registration methods. The VTM can lead to accuracy degradation, in particular due to patient movement during scanning. Simulations were performed and CT data sets acquired with patients fitted with the CRW or the GTC stereotactic localizer were analyzed. Comparison of STM- and VTM-derived stereotactic coordinates shows an average overall registration error of 0.1 mm for anesthetized patients and in the range 0.6-1.4 mm for nonanesthetized patient. Accuracy maps are described that enable the user to visualize the registration error in relation to the data. It is shown that the effect of fiducial point localization error and patient movement for VTM-based localization is minimized when all available fiducials in the region of interest are used. The significance of these results is discussed, and methods are proposed to minimize these effects for frame-based and frameless registration methods.

Humans↗

Genetic fusion of subunits I, II, and III of the cytochrome bo ubiquinol oxidase from Escherichia coli results in a fully assembled and active enzyme.

The cytochrome bo ubiquinol oxidase from Escherichia coli is a five-subunit enzyme which is a member of the superfamily of heme-copper respiratory oxidases. Three of the subunits (I, II, and III) are homologous to the three mitochondrial encoded subunits of the eukaryotic aa3-type cytochrome c oxidase. Subunits, I, II, and III of the eukaryotic oxidase contain 12, 2, and 7 putative transmembrane spans, respectively. The hydropathy profiles of the subunits of most other members of this oxidase superfamily are consistent with these structures. However, subunit I from the E. coli oxidase contains 15 transmembrane spans, with one additional span at the N-terminus and two additional spans at the C-terminus in comparison to the eukaryotic oxidase. The additional transmembrane helix at the N-terminus predicts that the amino terminal residue should be on the periplasmic side of the membrane. By deleting the intergenic region between the cyoA and cyoB genes, an in-frame fusion between subunit II (cyoA) and subunit I (cyoB) was generated. This links the C-terminus of subunit II, known to be on the periplasmic side of the membrane, to the N-terminus of subunit I. The resulting oxidase is fully active, and supports the toplogical folding pattern previously suggested for subunit I with the N-terminus in the periplasm. Whereas subunit I of the E. coli oxidase has two additional membrane-spanning helices at the C-terminus, subunit III has two fewer helices than does the corresponding subunit III of the eukaryotic oxidase.(ABSTRACT TRUNCATED AT 250 WORDS)

Base Sequence↗

Insight into the active-site structure and function of cytochrome oxidase by analysis of site-directed mutants of bacterial cytochrome aa3 and cytochrome bo.

Cytochrome aa3 of Rhodobacter sphaeroides and cytochrome bo of E. coli are useful models of the more complex cytochrome c oxidase of eukaryotes, as demonstrated by the genetic, spectroscopic, and functional studies reviewed here. A summary of site-directed mutants of conserved residues in these two enzymes is presented and discussed in terms of a current model of the structure of the metal centers and evidence for regions of the protein likely to be involved in proton transfer. The model of ligation of the heme a3 (or o)-CuB center, in which both hemes are bound to helix X of subunit I, has important implications for the pathways and control of electron transfer.

Amino Acid Sequence↗

Accuracy in frame-based and frameless stereotaxy.

Stereotactic surgery is currently undergoing great changes with a large number of frameless methodologies being developed alongside traditional frame-based systems. As a result, there is considerable uncertainty over the future clinical roles of the numerous stereotactic options now offered. We have reviewed the current scientific issues regarding accuracy in both frame-based and frameless stereotaxy. Frame-based systems have the advantage of proven clinical utility and instrument carriage with a high degree of mechanical stability and accuracy. Frameless methods are more complex, but also more flexible, and may have wide applications in general neurosurgery if clinical efficacy is confirmed.

Humans↗

Demonstration by FTIR that the bo-type ubiquinol oxidase of Escherichia coli contains a heme-copper binuclear center similar to that in cytochrome c oxidase and that proper assembly of the binuclear center requires the cyoE gene product.

Amino acid sequence data have revealed that the bo-type ubiquinol oxidase from Escherichia coli is closely related to the eukaryotic aa3-type cytochrome c oxidases. In the cytochrome c oxidases, the reduction of oxygen to water occurs at a binuclear center comprised of heme a3 and Cu(B). In this paper, Fourier transform infrared (FTIR) spectroscopy of CO bound to the enzyme is used to directly demonstrate that the E. coli bo-type ubiquinol oxidase also contains a heme-copper binuclear center. Photolysis of CO ligated to heme o at low temperatures (e.g., 30 K) results in formation of a CO-Cu complex, showing that there is a heme-Cu(B) binuclear center similar to that formed by heme a3 and Cu(B) in the eukaryotic oxidase. It is further demonstrated that the cyoE gene product is required for the correct assembly of this binuclear center, although this polypeptide is not required as a component of the active enzyme in vitro. The cyoE gene product is homologous to COX10, a nuclear gene product from Saccharomyces cerevisiae, which is required for the assembly of yeast cytochrome c oxidase. Deletion of the cyoE gene results in an inactive quinol oxidase that is, however, assembled in the membrane. FTIR analysis of bound CO shows that Cu(B) is present in this mutant but that the heme-Cu(B) binuclear center is abnormal. Analysis of the heme content of the membrane suggests that the cyoE deletion results in the insertion of heme B (protoheme IX) in the binuclear center, rather than heme O.(ABSTRACT TRUNCATED AT 250 WORDS)

Alkyl and Aryl Transferases↗

Restoration of a lost metal-binding site: construction of two different copper sites into a subunit of the E. coli cytochrome o quinol oxidase complex.

The cupredoxin fold, a Greek key beta-barrel, is a common structural motif in a family of small blue copper proteins and a subdomain in many multicopper oxidases. Here we show that a cupredoxin domain is present in subunit II of cytochrome c and quinol oxidase complexes. In the former complex this subunit is thought to bind a copper centre called CuA which is missing from the latter complex. We have expressed the C-terminal fragment of the membrane-bound CyoA subunit of the Escherichia coli cytochrome o quinol oxidase as a water-soluble protein. Two mutants have been designed into the CyoA fragment. The optical spectrum shows that one mutant is similar to blue copper proteins. The second mutant has an optical spectrum and redox potential like the purple copper site in nitrous oxide reductase (N2OR). This site is closely related to CuA, which is the copper centre typical of cytochrome c oxidase. The electron paramagnetic resonance (EPR) spectra of both this mutant and the entire cytochrome o complex, into which the CuA site has been introduced, are similar to the EPR spectra of the native CuA site in cytochrome oxidase. These results give the first experimental evidence that CuA is bound to the subunit II of cytochrome c oxidase and open a new way to study this peculiar copper site.

Amino Acid Sequence↗

Multimodality imaging and intracranial EEG display for stereotactic surgery planning in epilepsy.

We describe a computer program for stereotactic surgery planning based on multimodality imaging and the display of intracranial EEG data in relation to anatomical data. The program is primarily designed to be used by surgeons to assist them in localizing brain structures and plan the safe and accurate insertion of surgical tools and depth electrodes. The mathematics underlying these concepts are briefly described. Estimates of the accuracy of the procedures are calculated and made available to the user. An extension of the program was developed to integrate intracranial EEG data with conventional images in order to help the neurologist and neurosurgeon in visualizing the EEG data in relation to the anatomy. It can be used to visualize the measured EEG voltages, or processed signals such as the application of the tetrahedral field calculation, which provides an extension of conventional bipolar EEG to 3 dimensions.

Brain↗

Equivalent source estimation based on the calculation of the electric field from depth EEG data.

This paper describes a method for the estimation of equivalent source position and strength based on the estimation of the electric field from depth electroencephalographic (EEG) data. The calculation method for the electric field is based on a tetrahedral geometry. The proposed approach for source parametrization is twofold. Firstly, the distribution of electrical energy by the squared norm of the electric field vector can give an estimate of the source position, without having to assume a dipole source. Secondly, the average electric field can be related to the dipole magnitude and orientation of the equivalent source. Simulation results demonstrate the potential usefulness of the method. The effects of noise and sampling, and the geometry of the measurement system (i.e., implanted electrodes) relative to the source are also investigated through simulations.

Artifacts↗