Prediction of the chemiluminescent behavior of pharmaceuticals and pesticides.

The present paper deals with the first attempt to apply molecular connectivity calculations to predict a chemical property with analytical usefulness: the chemiluminescent behavior of substances when reacted with common oxidants in a liquid phase. Preliminary evidence when searching for new direct CL methods consisted of the examination of analyte reaction with a wide range of oxidants and media. This task, which results in time-consuming and trial-and-error expensive procedures, is necessary due to ensure empirical or theoretical rules for CL prediction are available. On the other hand, in quantitative structure-activity relationship studies, molecular connectivity is a topological method capable of describing the structure of a molecule by means of numbers named indices; subsequent regression in relation to the experimental values of the physical, chemical, or biological properties yields a series of functions called connectivity functions. Discriminant analysis was applied to 200 either chemiluminescent or nonchemiluminescent substances found either bibliographically or in an experimental screening. The method used for the selection of descriptors was a stepwise linear discriminant analysis from the Snedecor F-parameter. The classification criterion used was the minimum value of Mahalanobis. The quality of the discriminant function was calculated through the Wilks U-statistical parameter. Finally, the function was applied to a database including of more than 50,000 structurally heterogeneous compounds. The theoretical predictions were faced with the empirical evidence obtained through a continuous-flow manifold.

Algorithms↗

Solid-phase reactors as high stability reagent sources in flow analysis: selective flow injection spectrophotometric determination of cysteine in pharmaceutical formulations.

The flow injection spectrophotometric determination of cysteine was carried out by reaction with cobalt(II) ions entrapped in a polymeric material and filling a packed-bed reactor; the released cobalt(II) complexed with the amino acid was monitored at 360 nm. The method worked with a high repeatability, even with independent reactors, days and solutions. Selectivity of the procedure was tested with twenty different foreign compounds found in pharmaceutical formulations containing cysteine, parent amino acids included; no serious interferences were observed. The calibration graph for cysteine was linear over the range 1-90 micrograms ml-1 with a relative standard deviation of 0.8% at 60 micrograms ml-1 (n = 158). The calculated sample throughput was 90 h-1. The method was applied to determine the content of cysteine in pharmaceutical formulations.

Cobalt↗

Inhibition of the system luminol-H2O2-Fe(CN)6(3)-chemiluminescence by the Mn(II) indirect determination of isoniazid in a pharmaceutical formulation.

A flow injection procedure for the indirect chemiluminescent determination of isoniazid is proposed. The method is performed in a flow-injection manifold provided with a solid-phase reactor. The reactor was made from manganese dioxide physically entrapped by polymerization; the redox reaction isoniazid-manganese dioxide released Mn(II) which was monitored through its inhibitory effect on the reaction between luminol and hydrogen peroxide in presence of potassium hexacyanoferrate (III). The procedure resulted in a linear calibration graph over the range 5-15 mg/L of isoniazid with a sample throughput of 43 samples/h. The influence of foreign compounds was studied and the method was applied to determination of the drug in a pharmaceutical formulation.