Search PubMed⌕ Search

Biomedical subjects

L L Baker

Publications and source records attributed to L L Baker.

At least 37 records · Page 2Linked to original sources

MR imaging of brain contusions: a comparative study with CT.

Ninety-eight brain contusions in 17 patients served as a data base for a comparative study of MR and CT for defining brain contusions. MR was the more sensitive technique, detecting 98% of the brain contusions compared with only 56% by CT. CT was slightly better for showing hemorrhagic components, documenting 77% of hemorrhages compared with 71% for MR. The appearance of the contusions on MR was variable, depending on the T1- and T2-weighting of the images and the constituents of the contusions, such as edema, hemorrhage, and encephalomalacia. On MR, hemorrhagic components appeared as high signal on T1-weighted images and as either low or high signal on T2-weighted images, depending on the age of the hemorrhage. The approximate ages of hemorrhagic contusions were often suggested by their appearance on T1- and T2-weighted images. CT is very effective for evaluating acute head trauma, but MR is recommended for documenting brain contusions during the subacute and chronic stages of head injuries.

Adolescent↗

Effects of waveform on comfort during neuromuscular electrical stimulation.

Electrical stimulation is a commonly used clinical tool, but subject and patient comfort is still a major problem retarding its widespread application. Stimulus waveform in combination with pulse duration can play a major part in subject comfort. An asymmetric balanced biphasic square waveform was perceived as comfortable and was clinically effective in stimulating wrist flexor and extensor muscles. Subjects preferred the square waveforms over a paired spike monophasic waveform. In the larger quadriceps muscle group, a symmetric biphasic square wave was perceived as more comfortable than either a monophasic paired spike or any of three medium frequency waveforms. There seemed to be, however, a small subpopulation of subjects who consistently preferred the medium frequency waveforms. Medium frequency stimulation should be tried for those patients who have considerable difficulty adapting to the sensory input inherent with the use of surface electrical stimulation.

Adult↗

Characterization of hindlimb motoneuron membrane properties in acute and chronic spinal cats.

The purpose of this study was to determine if changes in hindlimb motoneuron membrane electrical properties occur 4-6 months after spinal transection in the adult animal. Eight acute and nine chronic animals were spinalized at T12. Intracellular recordings from motoneurons innervating the triceps surae were performed. Membrane electrical properties, including resting potential, action potential peak amplitude, afterhyperpolarization duration, rheobasic current, input resistance and axonal conduction velocity were measured. There were no statistical differences found between group means or frequency distributions in the membrane properties of motoneurons assessed from acute and chronic spinal animals. Thus, alteration of motoneuron membrane properties does not appear to be a major contributing factor to the hyperexcitable hindlimb reflex activity demonstrated by chronic spinal animals.

Action Potentials↗

Characterization of postsynaptic potentials evoked by sural nerve stimulation in hindlimb motoneurons from acute and chronic spinal cats.

The purpose of this study was to characterize the changes in postsynaptic potentials recorded in ankle extensor motoneurons resulting from activation of the sural nerve after spinal cord transection in the adult cat. Eight acute and nine chronic animals were spinalized at T12. Intracellular recordings from motoneurons innervating the triceps surae were performed. Sural nerve stimulation evoked complex synaptic potentials consisting of early and late components in all motoneurons. Early excitatory and inhibitory postsynaptic potentials (PSPs), as well as long latency excitatory postsynaptic potentials were recorded and averaged for assessment of PSP amplitude and duration. Early PSPs, both excitatory and inhibitory, were significantly larger in the motoneurons of cats spinalized 4-6 months earlier. Central latency of excitatory potentials were similar in the two samples of motoneurons, but the central latency associated with the initial inhibitory PSP was significantly shorter in the recordings from motoneurons of chronic spinal cats. In most recordings, an additional inhibitory PSP followed the initial excitatory PSP in motoneurons, and this secondary inhibitory PSP was similar in peak amplitude and duration in both samples of motoneurons. Also, a long latency excitatory PSP was recorded in a large percentage of motoneurons from both samples. This potential was typically of greater amplitude and longer duration in the motoneurons from chronic animals, when compared to recordings from acute animals. Although changes in amplitude and duration of PSP activity could be documented, there was no marked alteration in the frequency of occurrence of each PSP pattern recorded from the two preparations. This suggests that the synaptic pathways mediating the sural nerve reflexes have not qualitatively changed in the chronic spinal animal. The changes in amplitudes and durations of the PSPs in the chronic spinal cat indicate, however, that quantitative changes have occurred. The quantitative changes have probably occurred in the interneuronal networks activated by cutaneous nerve (sural) stimulation, since it was shown that only minor changes in motoneuron membrane properties could be recorded in these same chronic spinal animals.

Action Potentials↗

Magnetic resonance imaging of glenohumeral joint diseases.

Through the application of oblique planes and flexible surface coil techniques, magnetic resonance imaging (MRI) promises to be of great clinical value in the evaluation of a variety of pathologic conditions affecting the shoulder. In patients with joint effusions, the tendinous portion of the rotator cuff, glenoid labrum, and bicipital tendon can be readily visualized. This capability has particular relevance in patients with inflammatory disease and traumatic conditions. Rotator cuff atrophy and impingement of the coracoacromial arc upon the supraspinatus muscle and tendon can also be demonstrated. MRI is also useful in the evaluation of shoulder instability.

Humans↗

High-resolution magnetic resonance imaging of the wrist: normal anatomy.

Magnetic resonance imaging (MRI) provided adequate depiction of carpal soft tissue structures in normal volunteers, as well as accurate anatomic correlation with cadaveric specimens. Using a high field strength system and surface coil techniques, the intricate anatomy of the wrist was best defined on long TR short TE images. However, from a practical view, T1 weighted images (TR 600 ms, TE 25 ms) were most useful because of short imaging times, satisfactory image quality, and the absence of motion artifacts. The coronal plane provided the clearest definition of important structures. Potential diagnostic limitations exist due to the inability of MRI to clearly delineate articular cartilage, joint capsules, and small interosseous ligaments. The presence of intra-articular fluid in both living subjects and cadaveric specimens, however, allowed for fine depiction of these structures on T2 weighted images.

Humans↗

The high signal intensity meniscus of the knee. Magnetic resonance evaluation and in vivo correlation.

This study describes the different appearances of meniscal abnormalities on magnetic resonance (MR) images and correlates macroscopic and histologic findings. Twenty-three of 40 cadaveric menisci with MR signal abnormalities were examined macroscopically; five of the 23 were studied histologically. In addition, MR studies of seven patients (14 menisci) were examined and findings were correlated arthroscopically. Histologic analysis was performed on two of these menisci. The two major findings on MR images were: (1) abnormal, high, centrally located signal intensity within the meniscus and (2) disruption of the peripheral meniscal contour. Macroscopically evident meniscal degeneration correlated well with findings on MR images in all cases. Histologic abnormalities included microcyst formation and separation of collagen bundles. Four menisci with intact outer contour lines on MR images had macroscopically identifiable tears. In addition, two meniscal tears were appreciated only after intra-articular injection of gadolinium-DTPA. We conclude that MR imaging is superior to macroscopic examination as performed by arthroscopy or arthrotomy for the detection of degenerative meniscal lesions. The technique also accurately identifies meniscal tears, a capability that might be enhanced by prior intra-articular injection of MR contrast agents.

Adult↗

Focal fat deposition in axial bone marrow: MR characteristics.

One hundred fifty-eight magnetic resonance (MR) imaging studies of the spine were reviewed to assess the frequency and distribution of focal deposits with signal behavior typical of fat in the axial bone marrow. In addition, three fresh cadaveric spines were evaluated with MR imaging and subsequently sectioned for anatomic and histologic correlation. Macroscopic evaluation of the sectioned cadaveric specimens revealed well-defined, yellow areas within the bone marrow that correlated precisely with localized zones of signal intensity characteristic of fat on MR images. Histologic evaluation of these regions demonstrated typical focal fatty replacement of hematopoietic bone marrow. Their appearance was related to age and the presence of pathologic changes such as spondylitis, kyphoscoliosis, and spondylosis. Based upon these observations, focal fatty replacement of hematopoietic bone marrow appears to be a common phenomenon that should not be confused with localized disease processes.

Adipose Tissue↗

MR arthrography: anatomic-pathologic investigation.

To enhance the efficacy of magnetic resonance (MR) imaging in evaluating articular soft-tissue structures, arthrography was performed before imaging 45 fresh cadaveric specimens. Contrast agents used were gadolinium-DTPA, 0.9% saline, diatrizoate, and air. MR imaging was performed with and without intraarticular contrast material, and specimens were subsequently sectioned in the same plane. Gd-DTPA was the most effective agent. Saline and diatrizoate exhibited equivalent signal behavior and necessitated T2-weighted sequences, while air was not useful. Depiction of normal anatomy was enhanced with MR arthrography. After surgical creation of lesions in selected specimens, subtle tears were delineated exclusively with MR arthrography, and major tears were diagnosed more confidently. Intraarticular contrast material may enhance the diagnostic capabilities of MR imaging in the setting of joint disease.

Air↗

MR imaging of the scrotum: normal anatomy.

High-resolution magnetic resonance (MR) imaging with a surface coil was utilized to evaluate the normal scrotum. Scrotal contents, spermatic canal, and inguinal regions were visualized within the same field of view. Differences in signal intensity in the testis, epididymis, tunica albuginea, fluid, fat, and spermatic cord allowed for clear delineation of these structures in detail. The high contrast and spatial resolution of MR imaging, coupled with the wide field of view and absence of ionizing radiation, make MR imaging well suited for evaluation of the scrotum.

Adult↗

MR imaging of the scrotum: pathologic conditions.

The utility of high-resolution magnetic resonance (MR) imaging in studying a variety of intratesticular and extratesticular pathologic conditions was assessed. The high magnetic signal intensity of the testis provided an excellent background for visualization of intratesticular abnormalities. Except for old blood, all intratesticular processes were less intense than testis, especially on T2-weighted images. The visualization of the tunica albuginea is a distinct advantage, allowing its assessment in cases of trauma or testicular tumors. Epididymal and spermatic cord abnormalities were easily recognized. All pathologic conditions were best seen on T2-weighted images acquired in the coronal plane. Balanced images allowed for tissue characterization.

Genital Diseases, Male↗

Perfluorochemicals as gastrointestinal contrast agents for MR imaging: preliminary studies in rats and humans.

The ability to distinguish bowel from other intraabdominal structures is essential for the accurate diagnosis of intraabdominal disease with MR. Because perfluorochemicals have no protons, they cause no MR signal. Since they are immiscible with water, they create a signal void in bowel independent of bowel contents and thus are suitable as oral contrast agents. Furthermore, they are tasteless and odorless and have no side effects. We evaluated the use of perfluorochemicals by performing MR scans of the abdomen in rats after the oral administration of unemulsified perfluorohexylbromide or perfluoroctylbromide. Since the latter is approved as an investigational drug for oral use in humans, two volunteers were also studied. Both compounds created signal void in the bowel of both rats and human subjects allowing identification of the gastrointestinal tract. The results suggest that these compounds have potential as oral contrast agents for MR imaging.

Animals↗

Magnetic resonance imaging of the lumbar spinous processes and adjacent soft tissues: normal and pathologic appearances.

The spinous processes and intervening soft tissues of the lumbar region may be involved by degenerative, inflammatory, neoplastic, and traumatic processes resulting in low back pain. While conventional radiography and computed tomography have proven useful in the demonstration of abnormalities affecting the spinous processes, they are of limited utility in the evaluation of the intervening soft tissues, which are the predominant site of initial pathologic involvement. To explore the potential role of magnetic resonance imaging (MRI) in the assessment of the spinous processes and adjacent ligaments, a retrospective review of 55 consecutive examinations of the lumbar spine was performed. The normal and pathologic appearances of the region on both T1 and T2 weighted images were characterized, and the optimal imaging variables for demonstration of the spinous processes and adjacent soft tissues were determined with subsequent prospective application to new cases. Correlative examination of cadaveric sections and dried specimens was also performed to facilitate understanding of anatomical relationships visualized by MRI. Based upon the results of this investigation, MRI is the procedure of choice in the evaluation of disease processes affecting the spinous processes and intervening ligaments, primarily owing to the ability to image directly in the sagittal plane and its superior soft tissue contrast discrimination capability.

Adolescent↗

High-resolution magnetic resonance imaging of the ankle: normal anatomy.

An imaging-anatomic correlative study of ankle anatomy based upon six healthy adults and six fresh cadaveric specimens was performed to evaluate the diagnostic capabilities of magnetic resonance imaging (MRI). Optimal pulsing sequences and imaging planes for various structures of interest were established. MRI afforded exquisite depiction of anatomic detail, particularly the diagnostically important collateral ligaments. Limitations in the ability to delineate the joint capsule and articular cartilage were documented, with the former detectable only on T2 weighted images in the presence of synovial fluid.

Adult↗

Neuromuscular electrical stimulation of the muscles surrounding the shoulder.

Neuromuscular electrical stimulation (NMES) can be used to augment range-of-motion, strengthening, and facilitation treatment programs of the muscles surrounding the shoulder. The purposes of this article are 1) to describe the uses of NMES around the shoulder joint as developed through our clinical use and 2) to detail the effects of an NMES program on chronic shoulder subluxation as determined by a clinical study. Because of the complexities of this multiarticular joint, NMES is most useful in the initial phase of the ROM, and stimulated contractions are compromised, relatively, as the humerus moves above the 90-degree horizontal plane. The use of NMES to provide scapular stabilization often entails unwanted alteration of the pressures on the spinal column, occasionally making the treatment program unusable. Electrical stimulation to prevent or correct shoulder subluxation, especially in the neurologically involved patient, provides the therapist with a powerful new treatment technique. In a group of stroke patients, shoulder subluxation was reduced significantly (p less than .05) at the completion of a six-week NMES program. Some of the problems, and possible solutions, unique to the development of electrical stimulation programs for the shoulder muscles are discussed.

Adult↗

Effects of waveform parameters on comfort during transcutaneous neuromuscular electrical stimulation.

Twenty-three females between the ages of 19 and 35 were studied in order to compare the effects of variations in pulse duration, waveform symmetry, and source regulation on comfort during quadriceps surface stimulation at amplitudes necessary to produce 27 Nm torque. Stimulation parameters compared were: 1) 50 and 300 microseconds pulse durations, 2) asymmetrical and symmetrical biphasic waveforms, and 3) current and voltage source regulation. Subjects overwhelmingly preferred the 300 microseconds pulse duration regardless of waveform or source regulation, strongly preferred the symmetrical biphasic waveform, and had inconsistent preference for either regulated voltage or regulated current sources.

Adult↗

High- and low-density lipoprotein cholesterol: correlates in an older population.

A predominantly upper-middle-class white population of 279 men and 345 women with an average age of 66 years was evaluated to determine correlates of high- and low-density lipoprotein cholesterol (HDL and LDL), since these may be the only cholesterol measurements predictive of cardiovascular disease after age 50. Associations of HDL and LDL with age, alcohol use, obesity, smoking, diet, exercise, and medication use were examined using multiple linear regression. Alcohol, average and above-average exercise, postmenopausal estrogen use (women), B vitamin intake, and corticosteroid use were all positively related to HDL levels, and obesity (men only), cigarette smoking, and thyroid hormone use were inversely related. The only statistically significant correlates of LDL were an increase with age (women only) and lower levels in women using thyroid hormone. However, the associations of several behavioral variables with LDL, although not statistically significant, were in the expected direction. These results may suggest the continuing potential for preventive intervention even in an elderly population.

Age Factors↗