Ten consecutive patients (mean age 57.9 +/- 7.6 years) were treated with an investigational tachyarrhythmia control device, the implantable Medtronic Pacer-, Cardioverter-, Defibrillator model 7216A or 7217B. All patients had coronary artery disease with old myocardial infarctions and presented hemodynamically significant sustained ventricular tachyarrhythmias not suppressed by antiarrhythmic drug therapy and unrelated to acute myocardial infarction. In two patients a nonthoracotomy lead system was implanted. Lowest effective defibrillation energy ranged from 5 to 18 joules (mean 12.2 +/- 4 joules) for the epicardial bielectrode systems and were 15 and 18 joules for the nonthoracotomy lead system implants. The postoperative periods were unremarkable. Follow-up ranged from 7 to 19 months (mean 13.8 +/- 4.5 months). Spontaneous tachyarrhythmia episodes were detected and treated by the device in six patients, five of them received staged therapies. No deaths occurred and no hospital admissions were necessary for device related or ventricular tachyarrhythmia related complications. In conclusion, this integrated device represents a major step toward the development of a universal ventricular arrhythmia control device.
We studied clinical characteristics and coexisting causes of stroke in 305 patients admitted to a population-based primary care center with an initial ischemic stroke and a potential cardiac source of embolism (PCSE). Using systematic standardized cardiac, arterial, and cerebral investigations and the logistics of the prospective Lausanne Stroke Registry, we found that nonprogressive onset, hemianopia without hemiparesis or hemisensory disturbances, Wernicke's aphasia, ideomotor apraxia, involvement of specific territories (posterior division of middle cerebral artery, anterior cerebral artery, cerebellum, multiple territories), and a hemorrhagic component were associated with the presence of a PCSE, as compared with 1,006 initial ischemic stroke patients without PCSE. Although age and sex did not differ, the frequency of hypertension, diabetes, cigarette smoking, elevated blood cholesterol, and deep hemispheric or brainstem infarcts was higher in the patients without a PCSE. Nearly one-fourth of the patients with a PCSE had a coexisting potential arterial cause of stroke (large artery greater than or equal to 50% stenosis or small-vessel disease). In the majority of patients with a PCSE (76.7%), cardioembolism was the most likely cause of stroke, although a direct source of embolism was uncommon (4.3%) and intracranial embolic occlusions were present in less than one-half of the patients who were angiographed.
Because the great majority of clinically relevant arrhythmias are based on the principle of reentry, the understanding of the basic principle of this mechanism leads to alternative nonpharmacological therapy for such arrhythmias. The reentry circuit might be interrupted definitively by surgical or catheter ablative procedures, such as DC-energy shock delivery or radiofrequency coagulation, which will both lead to complete prevention of the tachycardia. On the other hand, electrical stimulation may influence the circus movement by wavefront collision and thus interrupt the tachycardia after it started. Antitachycardia pacemakers work on this principle. One major impact of antiarrhythmic treatment is the prevention of sudden death. The implantable defibrillator is currently the only treatment that really proves to be reliable in aborting sudden death. It is therefore the "gold standard" of antiarrhythmic treatment in life-threatening arrhythmias.
Explore the source record for details and available documents.
We studied 305 patients with a first stroke and a potential cardiac source of embolism (PCSE), on the basis of the Lausanne Stroke Registry. We have compared these patients with 1006 patients with stroke but without PCSE, admitted into the Registry during the same period, in order to assess the potential role of PCSE and the coexistence of other causes of stroke. Analysis of the various types of PCSE suggests that some neurologic characteristics are more frequent in patients with than without PCSE (infarcts of the posterior division of middle cerebral artery with Wernicke's aphasia and lateral hemianopia; maximal neurologic deficit at onset; haemorrhagic infarcts).
Antiarrhythmic therapy is intended for relief of symptoms or to reduce the risk of sudden death. Recent observations have cast doubt on the causal correlation between ventricular premature beats, ventricular tachycardia and ventricular fibrillation. The therapeutic approach has therefore to be modified in the light of new trends, and take into consideration electrophysiologic aspects and new diagnostic and therapeutic procedures.
Over a six months' period we prospectively studied the prevalence of patent foramen ovale (PFO) in patients under 50 years of age admitted for cerebral infarction as assessed by cerebral computed tomography. The study recruited 16 patients (9 male, 7 female, mean age 39 +/- 10 years). Before the contrast study, 5 patients had other identifiable sources of stroke after neurologic investigations and 2-D echocardiography with color-Doppler, whereas 11 had no precise origin. The overall prevalence was 50% with 8 PFO demonstrated, 6 during normal breathing and two during a coughing test. All were in the sub-group of 11 patients without a predetermined source of stroke (prevalence 73%) and in 83% of patients aged under 40. In accordance with the literature, we found a high prevalence of PFO in the ischemic cerebral infarction population aged under 50 years and without another possible source of stroke; this prevalence is higher in patients under 40 years old. This observation confirms the suspicion of paradoxical embolism in these cases.
Electrophysiologic studies are used for diagnosis and treatment in patients with sustained ventricular tachycardia. This method can only be employed if high inducibility of the spontaneous tachycardia can be demonstrated. We therefore investigated prospectively the induction yield in 35 patients with a history of documented sustained ventricular tachycardia. The patients' mean age was 58 years. Coronary artery disease was present in 24 patients, cardiomyopathy in 4, other organic heart diseases in 4, and no heart disease in 3. The ventricular tachycardia induction protocol consisted of three extrastimuli delivered during sinus rhythm and at two pacing cycle lengths, followed by intravenous isoproterenol if no tachycardia was induced before. With the method sustained ventricular tachycardia was induced in 100% of patients with coronary artery disease and cardiomyopathy, in 75% of patients with other heart diseases and in 33% of patients without detectable heart disease. We conclude that electrophysiologic studies have a high yield of sustained ventricular tachycardia induction in patients with underlying organic heart disease. The rational basis for use of electropharmacologic testing therefore exists in these patients. However, in patients without heart disease, the low sensitivity of electrophysiologic studies precludes its use for drug efficacy testing.
Explore the source record for details and available documents.
The introduction of balloon angioplasty represents the major step in modern cardiology. Today four different techniques for interventional treatment of coronary artery disease are at our disposition for classic balloon angioplasty, laser balloon, catheter atheromectomy and endovascular prosthesis make interventions in coronary artery disease more easy and reliable. However, the main problem, restenosis, which appears in one fourth of the cases, is not yet resolved. We report our experience in 1000 cases of transluminal approach to coronary artery disease.
Left atrial (LA) function was studied in 32 patients during percutaneous transluminal coronary angioplasty of the proximal left anterior descending artery with a dual micromanometer positioned transseptally in the left atrium and in the left ventricle. In 10 patients LA and left ventricular (LV) cineangiography was performed 30 minutes before percutaneous transluminal coronary angioplasty and 30 seconds after the occlusion of the left anterior descending coronary artery. Thirty seconds after left anterior descending occlusion, LV peak systolic pressure decreased from 135 +/- 12 to 106 +/- 9 mm Hg (p less than 0.05) and LV maximum dP/dt decreased from 1,634 +/- 136 to 1,137 +/- 127 mm Hg/s (p less than 0.01). Simultaneously, LA mean pressure increased from 11 +/- 2 to 29 +/- 1 mm Hg (p 177 +/- 13 to 381 +/- 21 mm Hg (p less than 0.001). There was a difference between LV end-diastolic pressure and LA mean pressure of 1.5 mm Hg at rest and 7.8 mm Hg during ischemia and LA pulse pressure increased from 16 +/- 3 to 26 +/- 3 mm Hg (p less than 0.05) together with increase of LA A and V waves peak pressure. LV stroke volume index decreased from 46 +/- 5 to 43 +/- 3 ml/m2 (difference not significant). The LA maximal volume increased from 18 +/- 2 to 29 +/- 3 ml/m2 (p less than 0.001). LA volume before LA contraction increased from 29 +/- 2 to 54 +/- 3 ml/m2 (p less than 0.001).(ABSTRACT TRUNCATED AT 250 WORDS)
Eight women (mean age 41 years, range 24 to 62) with drug-resistant atrioventricular (AV) node reentrant tachycardia underwent radiofrequency catheter ablation. Radiofrequency energy was delivered in a unipolar mode with use of a back paddle as the anode placed between the two scapulae. The total applied energy was 2,233 +/- 1,919 J. The AH interval increased from 87 +/- 13 to 113 +/- 17 ms (p less than 0.05) and the PQ interval increased from 141 +/- 15 to 169 +/- 34 ms (p less than 0.05). The anterograde Wenckebach cycle length increased from 300 +/- 41 to 320 +/- 42 ms (p less than 0.05). Retrograde conduction was abolished in five patients. Atrioventricular node tachycardia was still inducible in three patients. During a follow-up period of 9 +/- 3 months, four patients remained clinically asymptomatic without drug therapy and four patients had recurrent symptoms. Three of the latter responded to previously unsuccessful antiarrhythmic drugs and the fourth patient underwent surgical cure for persistence of tachycardia. Right bundle branch block occurred in five patients; it was permanent in four and transient in one. In conclusion, radiofrequency catheter ablation represents a valuable but still investigational therapy in patients with drug-refractory AV node reentrant tachycardia.
Two cases with drug refractory ectopic atrial tachycardia are described. A map-guided partial resection of the right atrium (RA) was done after preoperative endocardial catheter mapping had shown well-defined areas of fractionated RA potentials. Intraoperatively, there were no aneurysmal formations present as described by other authors. Histopathologic examination of the resected tissue showed atrial myocarditis in both patients. Postoperative right ventricular myocardial biopsies revealed no inflammatory tissue. A minor elevation of antibodies against echoviruses was found in one case. Postoperative electrophysiologic studies were negative. We conclude: focal RA myocarditis without concomitant ventricular myocarditis may represent one cause of drug-resistant ectopic atrial tachycardia. Map-guided surgical intervention may cure the disease.
To compare the complication rate in patients having a dual chamber versus a single chamber pacing system, 337 consecutive procedures performed during a 3-year period were analyzed prospectively. Two hundred fifty-eight patients (77%) received a VVI pacemaker and 75 (23%) a DDD unit. Thirteen VVI (5%) and 4 DDD (5.3%) needed reintervention. Lead displacement with reoperation was required for three ventricular leads (1%) and one atrial lead (1.3%). Infection occurred in two VVI units (0.77%) and one DDD (1.33%) unit. Muscular stimulation was noticed among three DDD (4%) and nine VVI systems (3.5%). Urgent reprogramming was needed for 23 VVI (9%) and six DDD units (8%). There was no increase in complications with dual chamber pacing compared to single chamber systems.
The follow-up and characteristics of 20 patients with ventricular tachycardia (VT) and no detectable heart disease is reported. These were 16 men and four women with a mean age of 44 years. Symptoms were present in 18 patients (eight had syncope and ten palpitations or dizziness), VT was sustained in 11 patients and a left bundle branch block morphology with inferior axis was found in 17 patients. In three patients, VT had a right bundle branch block morphology and left-axis deviation. The VT was inducible in 13 patients during the electrophysiological testing (EP) and was sustained in five patients. Medical treatment was introduced in 19 patients. During a mean follow-up of 10 years from the onset of the symptoms and 6 years from the EP testing, one patient died suddenly. He had stopped taking amiodarone 5 months before. In seven patients symptoms recurred and were due to discontinuation of therapy in two cases and inefficacy of previous effective treatment in five patients. After modification of the treatment (three cases), implantation of a pacemaker (one case) and catheter ablation (one case), all patients became asymptomatic. Eleven patients became asymptomatic with the first administered antiarrhythmic therapy. One patient continues to be asymptomatic in spite of discontinuation of his medical therapy. We conclude that patients with VT and no detectable heart disease have a good long-term prognosis and that appropriate therapy can be found in almost all patients.
An antitachycardia pulse generator, the Intermedics Intertach 262-12 was implanted in 16 patients (14 patients with supraventricular tachycardia of various origins and two patients with recurrent ventricular tachycardia), who were not responsive to various antiarrhythmic drug regimens. The follow-up was from 6-49 months (mean 30.9 +/- 13.8). Five patients had a follow-up of over 3 years. The device was used in all patients. One patient with ventricular tachycardia died from a nonarrhythmic cause. Loss of responsiveness to burst pacing was observed in 1/14 patients with supraventricular tachycardia and nontolerance of antitachycardia pacing in one patient. Overall clinical success of pacing was observed in 13/16 patients = 81%. The pacemaker proved to be a versatile system with reliable tachycardia detection and termination functions.
We studied 21 consecutive patients from the Lausanne Stroke Registry, who had first-ever ischemic stroke and lone atrial fibrillation, with a standard protocol of investigations including brain CT, and non-invasive cardiac and arterial tests. Rarity of associated risk factors and extracranial; arterial disease, presence of distal intracerebral occlusions on early angiography, and topography of cerebral infarct suggested that cardioembolism was the cause of stroke, though echocardiographic evidence for an atrial thrombus was uncommon. There was no recurrence during a post-stroke 14-day phase, during which anticoagulant and antiaggregant therapies were systematically avoided. Though low, the main risk of stroke recurrence was 0.99 per 100 patient-years during a mean follow-up period of 4.8 years, including a mean duration of anticoagulant therapy of 2.3 years in 18 patients. On the other hand, no death, severe cardiac events, or disabling anticoagulation-related hemorrhages occurred.