Alloimmunity and nonimmunologic risk factors in cardiac allograft vasculopathy.

Graft vasculopathy is an accelerated form of coronary artery disease that occurs in transplanted hearts. Despite major advances in immunosuppression, the prevalence of the disease has remained substantially unchanged during the last two decades. According to the 'response to injury' paradigm, graft vasculopathy is the result of a continuous inflammatory response to tissue injury initiated by both alloantigen-dependent and independent stress responses. Experimental evidence suggests that these responses may become self-sustaining, as allograft re-transplantation into the donor strain at a later stage fails to prevent disease progression. Histological evidence of endothelitis and arteritis, in association with intima fibrosis and atherosclerosis, reflects the central role of alloimmunity and inflammation in the development of arterial lesions. Experimental results in gene-targeted mouse models indicate that cellular and humoral immune responses are both involved in the pathogenesis of graft vasculopathy. Circulating antibodies against donor endothelium are found in a significant number of patients, but their pathogenic role is still controversial. Alloantigen-independent factors include donor-transmitted coronary artery disease, surgical trauma, ischaemia-reperfusion injury, viral infections, hyperlipidaemia, hypertension, and glucose intolerance. Recent therapeutic advances include the use of novel immunosuppressive agents such as sirolimus (rapamycin), HMG-CoA reductase inhibitors, calcium channel blockers, and angiotensin converting enzyme inhibitors. Optimal treatment of cardiovascular risk factors remains of paramount importance.

Antibody Formation↗

Routine use of intravascular ultrasound for endovascular aneurysm repair: angiography is not necessary.

INTRODUCTION: to assess the outcome of endovascular aortic aneurysm repair (EVAR) using intravascular ultrasound (IVUS) without angiography. MATERIALS/METHODS: eighty consecutive patients (median age 69 years (range 25-90): male 72 (90%), female 8 (10%)) underwent endovascular aneurysm repair (AAA 68 (85%), TAA 12 (15%)) using either angiography in 31/80 patients (39%) or IVUS in 49/80 patients (61%) in accordance to the surgeons preference. RESULTS: hospital mortality was 2/80 (3%), 1/68 for AAA (2%), 1/12 for TAA (8%), 2/31 for angiography (7%), and 0/49 for IVUS (0.0%: NS). Median quantity of contrast medium was 190 ml (range: 20-350) for angiography versus 0 ml for IVUS (p<0.01). Median X-ray exposure time 24 min (range 9-65 min) versus 8 min (range 0-60 min) for IVUS (p<0.05). No coverage of renal or suprarenal artery orifices occurred in either group. Conversion to open surgery was necessary in 4/80 patients (5%), 1/31 for angiography (3%) and 3/49 patients for IVUS (6%: NS). Early endoleaks were observed in 13/80 patients (16%): 8/31 patients for angiography (26%) versus 5/49 for IVUS (10%: p<0.05): 5/13 endoleaks resolved spontaneously (39%) whereas 8/13 (61%) required additional procedures. CONCLUSIONS: IVUS is a reliable tool for EVAR. In most cases, perprocedural angiography is not necessary.

Adult↗

A new expandable cannula to increase venous return during peripheral access cardiopulmonary bypass surgery.

Peripheral cannulation for cardiopulmonary bypass (CPB) is of prime interest in minimally invasive open heart surgery. As CPB is initiated with percutaneous cannulae, venous drainage is impeded due to smaller vessel and cannula size. A new cannula was developed which can change shape in situ and therefore may improve venous drainage. An in vitro circuit was set-up with a penrose latex tubing placed between the preload reservoir and the cannula, encasing the cannula's inlet and simulating the vena cava. The preload (P) was stabilised at 2 and at 5 mmHg respectively. The maximum flow rate was determined for 4 conditions: passive venous drainage (PVD) and assisted venous drainage (AVD) using a centrifugal pump at the 2 preload settings. We compared the results of the prototype cannula to classical femoral venous cannulae: basket 28Fr, a thoracic 28Fr and a percutaneous 27Fr. Under PVD conditions and a CVP of 2 mmHg, the prototype cannula's flow rate outperformed the next best cannula by 14% (p=0.0002) and 13% under AVD conditions (p=0.0001). Under PVD conditions and a CVP of 5 mmHg, the prototype cannula outperformed the percutaneous cannula by 19% (p=0.0001) and 14% under AVD conditions (p=0.0002). The new cannula outperforms the classical percutaneous venous cannulae during all of the four conditions tested in vitro.

Cardiopulmonary Bypass↗

Poly2-methoxyethylacrylate (PMEA) coated oxygenator: an ex vivo study.

UNLABELLED: PMEA is a hydrophilic polymer coating with a unique design that minimizes the adsorption and denaturation of proteins and blood cells. This study compares thrombus resistance, blood path resistance, thrombocyte profile, and blood trauma of the PMEA coated Capiox membrane oxygenator (Terumo, Japan) vs. an uncoated version. METHOD: Six calves (mean bodyweight: 75.3 +/- 4.5kg) were placed on cardiopulmonary bypass for 6 hours and randomly assigned to the coated or uncoated oxygenator, with a low heparinisation protocol (ACT > 180s). RESULTS: Macroscopically, red staining was observed in all uncoated oxygenators, and in none of the coated ones. Inlet pressure was significantly higher in the uncoated group (at 1 h: 279 +/- 25 vs. 175 +/- 11mmHg, p < 0.01 and at 6h: 217 +/- 10 vs. 171(8mmHg, p < 0.01). Thrombocyte count values (corrected for hematocrit and normalized by prebypass values) were significantly higher in the coated group (at 1 h: 76 +/- 6 vs. 53 +/- 13%, p < 0.01 and at 6 h: 70 +/- 6 vs. 44 +/- 26%, p < 0.01). Plasma hemoglobin was below 100mg/L in both groups throughout the experiments. CONCLUSIONS: When compared with uncoated oxygenator, PMEA coated oxygenator exhibited increased thrombus resistance with lower inlet pressure and lower thrombocyte consumption. In both groups, trauma to red cells was minimal, emphasizing the efficient design of this type of oxygenator.

Acrylates↗

[Open heart radio frequency left atrial compartmentation during mitral valve surgery: an alternative to the labyrinth procedure?].

The authors report their experience of radiofrequency left atrial compartimentation during open heart mitral valve surgery on 37 patients with a 42 +/- 12 months history of atrial fibrillation. The preoperative left ventricular ejection fraction was 62 +/- 8%; the left atrial diameter was 59 +/- 11 mm. The mean operative time was 245 +/- 60 minutes, which included 19 +/- 5 minutes for the ablation procedure. There were 2 early postoperative deaths and 2 deaths from non-cardiac causes at 3 and 6 months. The left ventricular ejection fraction and left atrial dimension were significantly decreased at the time of hospital discharge (54 +/- 12% and 51 +/- 7 mm respectively) (p < 0.01). After an average follow-up of 1 year, 81% of patients were free of atrial fibrillation: 6 patients had undergone DC cardioversion and 1 had a dual-chamber pacemaker. Patients in sinus rhythm after the ablation were associated with shorter periods of atrial fibrillation and smaller left atrial dimensions postoperatively than those who remained in fibrillation. The authors conclude that radiofrequency compartimentation of the left atrium associated with antiarrhythmic therapy can interrupt atrial fibrillation in 81% of patients at 1 year: the ablation procedure takes only 8% of the operation time. Predictive factors of success of ablation should be defined to determine which patients benefit most from this technique.

Adolescent↗

Treatment of congenital aortic valve stenosis: impact of the Ross operation.

GOAL: To evaluate the impact of the Ross operation, recently (1997) introduced in our unit, for the treatment of patients with congenital aortic valve stenosis. METHODS: The period from January 1997 to December 2000 was compared with the previous 5 years (1992-96). Thirty-seven children (< 16 yrs) and 49 young adults (16-50 yrs) with congenital aortic valve stenosis underwent one of these treatments: percutaneous balloon dilatation (PBD), aortic valve commissurotomy, aortic valve replacement and the Ross operation. The Ross operation was performed in 16 patients, mean age 24.5 yrs (range 9-46 yrs) with a bicuspid stenotic aortic valve, 7/10 adults with calcifications, 2/10 adults with previous aortic valve commissurotomy, 4/6 children with aortic regurgitation following PBD, and 1/6 children who had had a previous aortic valve replacement with a prosthetic valve and aortic root enlargement. RESULTS: PBD was followed by death in two neonates (fibroelastosis); all other children survived PBD. Although there were no deaths, PBD in adults was recently abandoned, owing to unfavourable results. Aortic valve commissurotomy showed good results in children (no deaths). Aortic valve replacement, although associated with good results (no deaths), has been recently abandoned in children in favour of the Ross operation. Over a mean follow-up of 16 months (2-40 months) all patients are asymptomatic following Ross operation, with no echocardiographic evidence of aortic valve regurgitation in 10/16 patients and with trivial regurgitation in 6/16 patients. CONCLUSIONS: The approach now for children and young adults with congenital aortic valve stenosis should be as follows: (1) PBD is the first choice in neonates and infants; (2) Aortic valve commissurotomy is the first choice for children, neonates and infants after failed PBD; (3) The Ross operation is increasingly used in children after failed PBD and in young adults, even with a calcified aortic valve.

Adolescent↗

Myocardial angiogenesis induction with bone protein derived growth factors (animal experiment).

Myocardial angiogenesis induction with vascular growth factors constitutes a potential strategy for patients whose coronary artery disease is refractory to conventional treatment. The importance of angiogenesis in bone formation has led to the development of growth factors derived from bovine bone protein. Twelve pigs (mean weight, 73 +/- 3 kg) were chosen for the study. In the first group (n = 6, growth factor group) five 100 micrograms boluses of growth factors derived from bovine bone protein, diluted in Povidone 5%, were injected in the lateral wall of the left ventricle. In the second group (n = 6, control group), the same operation was performed but only the diluting agent was injected. All the animals were sacrificed after 28 days and the vascular density of the left lateral wall (expressed as the number of vascular structures per mm2) as well as the area of blood vessel profiles per myocardial area analysed were determined histologically with a computerised system. The growth factor group had a capillary density which was significantly higher than that of the control group: 12.6 +/- 0.9/mm2 vs 4.8 +/- 0.5/mm2 (p < 0.01). The same holds true for the arteriolar density: 1 +/- 0.2/mm2 vs 0.3 +/- 0.1/mm2 (p < 0.01). The surface ratios of blood vessel profiles per myocardial area were 4900 +/- 800 micron 2/mm2 and 1550 +/- 400 micron 2/mm2 (p < 0.01) respectively. In this experimental model, bovine bone protein derived growth factors induce a significant neovascularisation in healthy myocardium, and appear therefore as promising candidates for therapeutic angiogenesis.

Animals↗

Spinal cord stimulation treatment for angina pectoris: more than a placebo?

BACKGROUND: The effects of thoracolumbal spinal cord stimulation (SCS) are confined to restricted microcirculatory areas. This limitation is generally attributed to a predominantly segmental mode of action on the autonomic nervous system. The goal of this study was to determine whether SCS applied close to supraspinal autonomic centers would induce generalized hemodynamic changes that could explain its alleged antianginal properties. METHODS: Invasive hemodynamic tests were performed in 15 anesthetized Göttingen minipigs submitted to iterative cervical SCS of various duration and intensity. RESULTS: Hemodynamic changes exceeding 10% were observed in 59 of 68 SCS sessions (87%). Their extent and time to peak varied with SCS intensity. At 2, 5, and 10 V, significant (t test p < 0.05) peak changes occurred in cardiac output (+34%, +29%, and +28%, respectively), stroke volume (+19%, +16%, +15%), mean pressure (+9%, +27%, +40%), heart rate (+14%, +23%, +14%), systemic (-17%, NS, NS), and pulmonary vascular (25%, NS, NS) resistances. Strikingly, at 2 V, the increase in cardiac output (+34%) was higher than the synchronous rise in rate pressure product (+22%), indicating efficient cardiac work. At 10 V, however, the cardiac work was inefficient (rate pressure product + 53%/cardiac output + 28%). CONCLUSIONS: Low-voltage cervical neuromodulation reduces the postcharge and improves cardiac work efficiency. The resulting reduction in oxygen myocardial demand may account for decreased anginal pain.

Angina Pectoris↗

Is the GraftConnector a valid alternative to running suture in end-to-side coronary arteries anastomoses?

BACKGROUND: An animal study was carried out to compare long-term patency rates of coronary anastomoses performed with the GraftConnector versus running suture technique. METHODS: 10 sheep, 45 to 55 kg, underwent off-pump coronary artery bypass grafting (right internal mammary artery to left anterior descending artery). In 5 animals, the anastomosis was performed with a GraftConnector and in 5 animals with 7-0 running suture. Intraoperative fluoroscopy and a fluoroscopic control at 6 months were performed. After 6 months, the animals were sacrificed and the anastomoses were examined histologically. RESULTS: All animals survived at 6 months with 100% anastomosis patency rates in both groups. In the GraftConnector group, the anastomosis diameter at 6 months fluoroscopy was 118% of native left anterior descending artery versus 97% of the control group. Luminal anastomotic width at histology was 1.7 +/- 0.2 mm in the device group versus 1.6 +/- 0.1 mm in the control group. Mean intimal hyperplasia thickness was 0.21 +/- 0.1 mm in the device group versus 0.01 mm in the control group. CONCLUSIONS: The GraftConnector provides a consistent and reproducible coronary artery anastomosis and reduces technical demand and manual dexterity in coronary operations. Long-term results demonstrate that off-pump coronary artery bypass grafting performed with the GraftConnector had the same patency rate and luminal width as those performed with running suture.

Anastomosis, Surgical↗

Venous drainage with a single peripheral bicaval cannula for less invasive atrial septal defect repair.

New peripheral venous cannulae have recently been proposed for minimally invasive open cardiac surgery. We present a femoral venous cannula designed to simultaneously drain both superior and inferior vena cavae. Used in adult patients for atrial septal defect repair, the cannula allowed passive blood drainage of 70.6% +/- 11.7% of theoretical cardiac output. Drainage was augmented to 93.4% +/- 8.6% of theoretical cardiac output by means of a centrifugal pump.

Adult↗

Animal model to compare the effects of suture technique on cross-sectional compliance on end-to-side anastomoses.

OBJECTIVE: An animal model has been developed to compare the effects of suture technique on the luminal dimensions and compliance of end-to-side vascular anastomoses. METHODS: Carotid and internal mammalian arteries (IMAs) were exposed in three pigs (90 kg). IMAs were sectioned distally to perform end-to-side anastomoses on carotid arteries. One anastomosis was performed with 7/0 polypropylene running suture. The other was performed with the automated suture delivery device (Perclose/Abbott Labs Inc.) that makes a 7/0 polypropylene interrupted suture. Four piezoelectric crystals were sutured on toe, heel and both lateral sides of each anastomosis to measure anastomotic axes. Anastomotic cross-sectional area (CSAA) was calculated with: CSAA = pi x mM/4 where m and M are the minor and major axes of the elliptical anastomosis. Cross-sectional anastomotic compliance (CSAC) was calculated as CSAC=Delta CSAA/Delta P where Delta P is the mean pulse pressure and Delta CSAA is the mean CSAA during cardiac cycle. RESULTS: We collected a total of 1200000 pressure-length data per animal. For running suture we had a mean systolic CSAA of 26.94+/-0.4 mm(2) and a mean CSAA in diastole of 26.30+/-0.5 mm(2) (mean Delta CSAA was 0.64 mm(2)). CSAC for running suture was 4.5 x 10(-6)m(2)/kPa. For interrupted suture we had a mean CSAA in systole of 21.98+/-0.2 mm(2) and a mean CSAA in diastole of 17.38+/-0.3 mm(2) (mean Delta CSAA was 4.6+/-0.1 mm(2)). CSAC for interrupted suture was 11 x 10(-6) m(2)/kPa. CONCLUSIONS: This model, even with some limitations, can be a reliable source of information improving the outcome of vascular anastomoses. The study demonstrates that suture technique has a substantial effect on cross-sectional anastomotic compliance of end-to-side anastomoses. Interrupted suture may maximise the anastomotic lumen and provides a considerably higher CSAC than continuous suture, that reduces flow turbulence, shear stress and intimal hyperplasia. The Heartflo anastomosis device is a reliable instrument that facilitates performance of interrupted suture anastomoses.

Anastomosis, Surgical↗

Active cooling during open repair of thoraco-abdominal aortic aneurysms improves outcome.

OBJECTIVE: Evaluate impact of active cooling with partial cardiopulmonary bypass (CPB) and low systemic heparinization during open repair of thoracoabdoninal aortic aneurysms. METHODS: Prospective analysis of 100 consecutive patients undergoing surgical repair of thoracoabdominal aortic aneurysms. Partial CPB and normothermic (36 degrees C) or hypothermic (29 degrees C) perfusion was selected in accordance to the surgeons preference. In the hypothermic group, aortic cross clamp was applied when the target temperature of the venous blood was achieved and rewarming was started after declamping. RESULTS: 52/100 patients (62.2+/-10.9 years) received normothermic and 48/100 patients hypothermic perfusion (63.8+/-10.6 years: NS). Emergent procedures accounted for 18/52 (35%) with normothermia vs. 21/48 (44%: NS) with hypothermia. The number of aortic segments (eight = maximum including arch and bifurcation) replaced was 3.9+/-1.5 with normothermia vs. 4.1+/-1.5 with hypothermia (NS); Crawford type II aneurysms accounted for 21/52 patients (40%) for normothermia vs. 20/48 (42%:NS) for hypothermia. Total clamp time was 38+/-21 min with normothermia vs. 47+/-28 min with hypothermia (P=0.05). Pump time was 55+/-28 min with normothermia vs. 84+/-34 min with hypothermia (P=0.001). Mortality at 30 days was 8/52 patients (15%) with normothermia vs. 2/48 (4%) with hypothermia (P=0.06; odds ratio = 4.1). Parapareses/plegias occurred in 4/52 patients (8%) with normothermia vs. 4/48 (8%) with hypothermia (NS). Revisions for bleeding were required in 4/52 patients (8%) with normothermia vs. 2/48 patients (4%) with hypothermia (P=0.38). Revisions for distal vascular problems were necessary in 5/52 patients (10%) with normothermia vs. 2/48 (4%) with hypothermia (P=0.25). Freedom from death, paraplegia, and surgical revision was 89.9% with normothermia vs. 94.8% with hypothermia (P=0.04; odds ratio 2.0). CONCLUSIONS: Active cooling during repair of thoracoabdominal aortic aneurysms allows for longer cross-clamp times, more complex repairs and improves outcome.

Aged↗

Smart suction device for less blood trauma: a comparison with Cell Saver.

OBJECTIVE: The major source of hemolysis during cardiopulmonary bypass remains the cardiotomy suction and is primarily due to the interaction between air and blood. The Smart suction system involves an automatically controlled aspiration designed to avoid the mixture of blood with air. This study was set-up to compare this recently designed suction system to a Cell Saver system in order to investigate their effects on blood elements during prolonged intrathoracic aspiration. METHODS: In a calf model (n=10; mean weight, 69.3+/-4.5 kg), a standardized hole was created in the right atrium allowing a blood loss of 100 ml/min, with a suction cannula placed into the chest cavity into a fixed position during 6 h. The blood was continuously aspirated either with the Smart suction system (five animals) or the Cell Saver system (five animals). Blood samples were taken hourly for blood cell counts and biochemistry. RESULTS: In the Smart suction group, red cell count, plasma protein and free hemoglobin levels remained stable, while platelet count exhibited a significant drop from the fifth hour onwards (prebypass: 683+/-201*10(9)/l, 5 h: 280+/-142*10(9)/l, P=0.046). In the Cell Saver group, there was a significant drop of the red cell count from the third hour onwards (prebypass: 8.6+/-0.9*10(12)/l, 6 h: 6.3+/-0.4*10(12)/l, P=0.02), of the platelet count from the first hour onwards (prebypass: 630+/-97*10(9)/l, 1 h: 224+/-75*10(9)/l, P<0.01), and of the plasma protein level from the first hour onwards (prebypass: 61.7+/-0.6 g/l, 1 h: 29.3+/-9.1 g/l, P<0.01). CONCLUSIONS: In this experimental set-up, the Smart suction system avoids damage to red cells and affects platelet count less than the Cell Saver system which induces important blood cell destruction, as any suction device mixing air and blood, as well as severe hypoproteinemia with its metabolic, clotting and hemodynamic consequences.

Animals↗

Beating heart coronary artery surgery: is sternotomy a suitable alternative to minimal invasive technique?

OBJECTIVES: To evidence the respective advantages and drawbacks of minimal invasive-thoracotomy (MIDCAB) and off-pump sternotomy (OPCAB) coronary bypass techniques. METHODS: The perioperative and mid-term (3 months) results of the first 31 MIDCABs and 39 OPCABs performed by a single experienced coronary surgeon (F.S.) were compared. Differences were assessed by two-tailed chi-square or unpaired t-test, and significance assumed for P-values < or =0.05. RESULTS: Groups were widely comparable. There were no in-hospital deaths nor permanent neurologic events. OPCAB patients received more anastomoses (mean 1.09/patient vs. 1.89/patient, P<0.001) during a shorter coronary occlusion period (26.1+/-8 vs. 16.6+/-4.5min, P<0.001), whilst immediate extubation prevailed in MIDCABs (22/31 vs. 17/39, P<0.05). Significant complications occurred in seven MIDCABs vs. none in OPCABs (P<0.01). Other in-hospital parameters were similar. Controls at 3 months evidenced more residual discomfort among MIDCAB patients (14/30 vs. 7/39, P<0.05). CONCLUSIONS: Differences in early complication rates may be due to a learning effect. However, OPCAB allows us to implant more grafts and is more comfortable for both patient and surgeon. These advantages may well counterbalance the cosmetic benefits of MIDCAB procedures.

Aged↗

Optimization of venous return tubing diameter for cardiopulmonary bypass.

OBJECTIVE: To determine the optimal venous tubing diameter for adult cardiopulmonary bypass (CPB) to improve gravity drainage and to reduce priming volume. METHODS: (A) Maximum bovine blood flow rates by gravity drainage were assessed in vitro for four different tubing diameters (1/2, 3/8, 5/16,1/4 inch) with three different lengths and various pre- and afterloads. Based on the results of (A) and multiple regression analyses, we developed equations to predict tubing sizes as a function of target flows. (C) The equations obtained in (B) were validated by ex vivo bovine experiments. (D) The clinically required maximal flows were determined retrospectively by reviewing 119 perfusion records at Zurich University. (E) Based on our model (B), the clinical patient and hardware requirements, the optimal venous tubing diameter was calculated. (F) The optimized venous tubing was evaluated in a prospective clinical trial involving 312 patients in Hangzhou. RESULTS: For a mean body surface area of 1.83+/-0.2 m(2), the maximal perfusion flow rate (D) achieved with 1/2-inch (=1.27 cm(2)) venous tubing was 4.62+/-0.57 l/min (range: 2.50-6.24 l/min). Our validated model (B,C) predicted 1.0 cm(2) as optimal cross-sectional area for the venous line. New tubing packs developed accordingly were used routinely thereafter. The maximal flow rate was 4.93+/-0.58 l/min (range: 3.9-7.0) in patients with a mean body surface area of 1.62+/-0.21 m(2). CONCLUSION: The new venous tubing with 1.0-cm(2) cross-sectional area improves the drainage in the vast majority of adult patients undergoing CPB and reduces the priming volume (-27 ml/m). Reduced hemodilution can prevent homologous transfusions if a predefined transfusion trigger level is not reached.

Adult↗

Reshaping the remodelled left ventricle: a new concept.

OBJECTIVE: Based on the law of Laplace, transventricular tension members were designed to diminish wall stress by changing the left ventricle (LV) globular shape to a bilobular one, thus reducing the ventricular wall radius of curvature. This concept was tested in a model of congestive heart failure. METHODS: Seven calves were used for the study (74.3+/-4.2 kg). Treatment efficacy was assessed with sonomicrometric wall motion analysis coupled with intraventricular pressure measurement. Preload increase was applied stepwise with tension members in released and tightened position. RESULTS: Tightening of the tension members improved systolic function for CVP>10 mmHg (dP/dt: 828+/-122 vs. 895+/-112 mmHg/s, P=0.019, for baseline and 20% stress level reduction respectively; wall thickening: 11.6+/-1.5 vs. 13.3+/-1.7%, P<0.001) and diastolic function (LV end-diastolic pressure: 15.9+/-4.8 vs. 13.6+/-2.7 mmHg, P<0.001, for CVP>10 mmHg; peak rate of wall thinning: -12.2+/-2.2 vs. -14+/-2.3 cm(2)/s, P<0.001 and logistic time constant of isovolumic relaxation: 48.4 +/-10.9 vs. 39.8+/-9.6ms, P<0.001, for CVP>5 mmHg). CONCLUSIONS: This less aggressive LV reduction method significantly improves contractility and relaxation parameters in this model of congestive heart failure.

Animals↗

Surgery for aortic coarctation: a 30 years experience.

OBJECTIVE: A retrospective study to review the experience of a single center with surgery for aortic coarctation over a period of 30 years (1970-1999). METHODS: Criteria for inclusion: (a) aortic coarctation, isolated or associated with congenital heart defect; (b) surgery between 1970 and 1999. Data recorded: (1) date of surgery; (2) age at surgery; (3) associated lesions; (4) surgical technique; (5) simultaneous surgical procedures; (6) early and late surgical results in term of: (a) deaths; (b) need for reoperation because of re-coarctation or other cardiac lesion; (c) residual/recurrent pressure gradient, evaluated at cuff/Doppler at rest; (d) systemic hypertension, requiring medical treatment. RESULTS: One hundred and forty-one patients underwent surgery for aortic coarctation: 30 neonates, 29 infants, 45 children and 37 adults. Associated lesions were found in 8/37 (=21.6%) adults and in 73/104 (=70.1%) pediatric patients. There were no hospital deaths. During the follow-up there were one late death in the adults group (1/37=2.7%) and three late deaths in the pediatric group (3/104=2.9%), all unrelated with aortic coarctation. Re-operation because of re-coarctation occurred only in ten late survivors of the pediatric group (10/101=9.9%), 9/10 operated on before 1980 (P<0.00001). End-to-end anastomosis, enlarged to the aortic arch in neonates, was associated with the lowest incidence of re-coarctation (P<0.005). A significant (>20 mmHg at rest) pressure gradient was found in none of the adults, and in seven of the 91 pediatric patients (7/91=7.7%) late survivors. Three adults (3/36=8.3%) late survivors are on medical treatment to control systemic hypertension. CONCLUSIONS: The long-term results of our retrospective study confirm that surgery has to be considered the gold standard for the treatment of aortic coarctation. The interventional angioplasty techniques have to provide long-term outcome at least similar to the results obtained with surgery.

Age Factors↗