Search PubMedSearch

Biomedical subjects

L K Gardner

Publications and source records attributed to L K Gardner.

At least 19 recordsLinked to original sources

Prosthetic rehabilitation of the cleft palate patient.

This article is a brief overview of prosthodontic and restorative methods used in the treatment of unilateral and bilateral cleft palate patients. Some past, present, and future methods of rehabilitation are discussed.

Adolescent

Swing-lock design considerations for obturator frameworks.

The conventional and swing-lock (S/L) obturator prostheses can be highly effective in restoring maxillary defects when careful attention is paid to the principles of framework design. Although the S/L modality has been available since the mid 1960s, its use in maxillofacial prosthetics has been limited, and little information is available in the literature to guide the practitioner. This modality offers a conservative design option that lies somewhere between the conventionally designed obturator prosthesis and the prosthesis designed to use extensive fixed reconstruction or endosseous implants. When the S/L obturator is considered, single, double, or dual labial bar designs are possible and may be required by the length and complexities of the arc of closure. Such designs provide a flexible labial bar that transmits less stress to abutment teeth. This article reviewed conventional obturator framework designs and compared them with S/L designs for similar patient categories.

Dental Abutments

Osteogenesis at the dental implant interface: high-voltage electron microscopic and conventional transmission electron microscopic observations.

The osteogenesis of mandibular bone to endosteal dental implants was examined using an in vivo dog model. One half of the implants examined were unloaded implants, with the remaining one half prosthodontically loaded for 6 months. Undecalcified mandibular implant samples were examined with both high-voltage electron microscopy (HVEM) stereology and routine transmission electron microscopy. The osseous interface to integrated implants was shown to vary in its morphology. Mineralized bone was observed directly apposing the implant, often separated from the implant by an electron-dense deposit of approximately 50 nm. Within this densely mineralized matrix, osteocytes were routinely observed. Adjacent areas were shown to contain slightly wider zones of either a less dense mineralized matrix or, alternatively, unmineralized tissue. Other zones consisted of wider unmineralized matrices containing collagen fibers and osteoblasts. These latter zones were consistent with the appearance of an appositional type of bone growth. Because bone is a dynamic, actively remodeling tissue, a varied morphology of the support tissues to dental implant is not unexpected. Areas of mature bone interfacing with successfully integrated implants were demonstrated, as well as areas adjacent to the mature bone that were undergoing remodeling or mineralization. This study has also shown that HVEM stereology is a valuable research tool to investigate the oral tissue interface with dental implants.

Aluminum Oxide

Morphology of the bone that supports endosteal dental implants. Transmission electron microscopic and high voltage electron microscopic observations.

The morphologic features of the bone-dental implant interface were investigated using an in vivo dog model. The undecalcified bone and associated support tissues were serially sectioned and examined with both conventional and high voltage transmission electron microscopy. A varied morphologic appearance of the tissues supporting clinically and radiographically appearing integrated implants was observed. Osteoblasts were observed at the implant interface, and osteocytes were routinely seen encased within lacunae extremely close to the implant surface. Often these osteocytes extended cellular projections to the implant surface. The variable tissue types observed were suggestive of healthy lamellar and appositional type mineralization patterns adjacent to the implants.

Animals

Comparative implant research in dogs: a prosthodontic model.

One-hundred twenty endosteal dental implants were inserted bilaterally in the mandibles of 30 adult mongrel dogs after bilateral extraction of all premolars. The 120 implants were evenly divided into one- and two-stage systems and included ceramic and titanium cylindrical root-form implants and titanium blade implants. The research design of this investigation divided the 30 animals into 10 groups of three dogs. This article describes an animal model that is useful in evaluating dental implant designs and compares the results with those from humans. In particular, this article delineates the prosthodontic approach appropriate for this model using one- and two-stage titanium implants. Rexillium alloy fixed prostheses were placed on 32 endosteal implants and 16 natural mandibular molar teeth. The implants and prosthetic components of the Sterio-Oss implant system were used. All prostheses are functional with minimal maintenance. To date, after 1-year of follow-up, none of the implants have been lost and none of the fixed prostheses have required recementation or maintenance other than normal hygiene. Histologic and survival data as well as results with other implant systems will be presented in other reports.

Animals

The mandibular swing-lock complete denture for patients with microstomia.

Regardless of cause, the treatment of an edentulous patient with microstomia is difficult and often ingenious. Prosthodontic treatment modalities previously described are reviewed. A new type of prosthesis, the collapsible mandibular swing-lock complete denture, is introduced. The prosthesis incorporates a cast cobalt-chromium framework with a lingual hinge and a conventional labial swing-lock. This combination allows the prosthesis to be collapsible while maintaining structural durability. Advantages include ease of insertion and removal while providing maximum coverage for support, retention, and stability. A stepwise technique for the clinical and laboratory phases is described.

Dental Impression Technique

Simulated implant surgery in rabbit long bones: a descriptive study.

The objectives of this study were: (a) to observe and describe the variability of bone healing in implant receptor sites which were prepared in rabbit femurs by use of different surgical methods; and (b) to determine if the animal model which was used was suitable for the detection of differences in healing reactions in implant receptor sites which were prepared by different surgical methods. Three 3-mm-wide implant receptor sites were prepared in the right and left femurs of four large New Zealand white rabbits. The surgical parameters used in preparation of the different sites included: low speed with no irrigation (LSO); low speed with internal irrigation only (LSI); low speed with external irrigation only (LSE); high speed with no irrigation (HSO); or high speed with external irrigation only (HSE). The sites were randomized so that each animal had one of each type of site in either the right or left femur. A non-treated control site was located in each animal for comparison with experimental sites. The animals were killed at 7, 14, 21, and 28 days post-operatively. The resultant samples were fixed, embedded, sectioned, and stained with basic fuchsin and toluidine blue. The results indicated that this was probably not a suitable animal model, since no discernible differences were detected in the various healed sites.

Animals

Comparative implant research in dogs: prosthodontic protocol using two-stage ceramic endosseous dental implants.

This report describes one phase of a long-term comparative implant investigation involving 20 of 120 endosseous implants placed in 30 adult mongrel dogs. Fixed prostheses involving 16 of the 20 (4 control implants) two-stage ceramic endosseous implants have been provided using routine prosthodontic procedures and the limited prosthetic components available for the Bioceram Series II implant system. The prostheses have proven to be functional with minimal maintenance. To date, after 1 year of follow-up, 2 of the two-stage implants have exhibited problems caused by fracture of the hexagonal collar. None of the implants to date has been lost and none of the fixed prostheses has required re-cementation or any other type of maintenance other than normal hygiene. Clinical evaluation suggests continued implant and prosthesis serviceability after 1 year in function.

Aluminum Oxide

Film thickness of die coating agents.

Die coating agents are often used during the fabrication of porcelain margins for crowns and fixed partial dentures. These agents seal microscopic irregularities within the stone die and resist abrasion. This investigation measured the film thickness of several die coating agents. A specific reference point was used during the measurement process. The results indicate that there is no significant difference between the die coating agents examined under the conditions of the study. The film thickness measurements ranged between 0.367 microns for Duro Super Glue Material and 2.3 microns for Zap CA material.

Acrylic Resins