Dynamic assembly by electrokinetic microfluidics.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to L James Lee.
Explore the source record for details and available documents.
Using low-pressure carbon dioxide (CO2), we demonstrated a novel and versatile approach to assembling polymeric constructs in the presence of cells and/or biomolecules in an aqueous environment. By regulating the CO2 pressure, the assembly was completed at biologically permissive temperatures with excellent preservation of the original structures. We further demonstrated that mammalian cells can survive the CO2-assisted bioassembly process (37 degrees C, 1.38 MPa, approximately 1 h). Human mesenchymal stem cells from bone marrow (hMSCs) exhibited the same cell morphology and proliferation potential as the untreated control. Mouse embryonic stem cells (mESCs) maintained ES-specific Oct-4 gene expression and differentiation potential after CO2 treatment as well. This method highlights the ability to construct multiple biodegradable polymeric scaffolds with well-defined architecture, on which various types of cells were grown, into a predesigned three-dimensional complex. In addition, protein and DNA bioactivity can be preserved in the context of a CO2-assisted assembly. This CO2-assisted bioassembly method provides for a manufacturing platform that, thus far, has been lacking in the fields of tissue engineering, cell-based biochips, cell therapy, and drug delivery.
A novel surface treatment method using poly(ethyleneimine) (PEI), an amine-bearing polymer, was developed to enhance antibody binding on the poly(methyl methacrylate) (PMMA) microfluidic immunoassay device. By treating the PMMA surface of the microchannel on the microfluidic device with PEI, 10 times more active antibodies can be bound to the microchannel surface as compared to those without treatment or treated with the small amine-bearing molecule, hexamethylenediamine (HMD). Consequently, PEI surface modification greatly improved the immunoassay performance of the microfluidic device, making it more sensitive and reliable in the detection of IgG. The improvement can be attributed to the spacer effect as well as the functional amine groups provided by the polymeric PEI molecules. Due to the smaller dimensions (140x125 microm) of the microchannel, the time required for antibody diffusion and adsorption onto the microchannel surface was reduced to only several minutes, which was 10 times faster than the similar process carried out in 96-well plates. The microchip also had a wider detection dynamic range, from 5 to 1000 ng/mL, as compared to that of the microtiter plate (from 2 to 100 ng/mL). With the PEI surface modification, PMMA-based microchips can be effectively used for enzyme linked immunosorbent assays (ELISA) with a similar detection limit, but much less reagent consumption and shorter assay time as compared to the conventional 96-well plate.
A mechanistic understanding of adipose tissue differentiation is critical for the treatment and prevention of obesity and type 2 diabetes. Conventional in vitro models of adipogenesis are preadipocytes or freshly isolated adipocytes grown in two-dimensional (2D) cultures. Optimal results using in vitro tissue culture models can be expected only when adipocyte models closely resemble adipose tissue in vivo. Thus the design of an in vitro three-dimensional (3D) model which faithfully mimics the in vivo environment is needed to effectively study adipogenesis. Pluripotent embryonic stem (ES) cells are a self-renewing cell type that can readily be differentiated into adipocytes. In this study, a 3D culture system was developed to mimic the geometry of adipose tissue in vivo. Murine ES cells were seeded into electrospun polycaprolactone scaffolds and differentiated into adipocytes in situ by hormone induction as demonstrated using a battery of gene and protein expression markers along with the accumulation of neutral lipid droplets. Insulin-responsive Akt phosphorylation, and beta-adrenergic stimulation of cyclic AMP synthesis were demonstrated in ES cell-derived adipocytes. Morphologically, ES cell-derived adipocytes resembled native fat cells by scanning electron and phase contrast microscopy. This tissue engineered ES cell-matrix model has potential uses in drug screening and other therapeutic developments.
Soft lithographic techniques were used to fabricate polymeric microparticles for drug delivery applications. The microparticles were made of thermoplastics and thermosets from different types of precursors including reactive resin and polymer solutions in organic solvents or water. The microparticles produced using these methods were made of widely used polymers for drug delivery with highly uniform sizes, plate-like morphology, and well-defined lateral sizes and shapes, making them potentially useful for drug delivery applications and as platform for the construction of multi-functional drug delivery devices.
Polymeric materials possess many attractive properties such as high toughness and recyclability. Some possess excellent biocompatibility, are biodegradable, and can provide various bio-functionalities. Proper combination of functional polymers and biomolecules can offer tailored properties for various biomedical applications. This overview article covers three major sections: Applications of Polymeric Structures and Devices, Nanoscale Polymer Fabrication Technologies, and Conclusions and Future Directions.
In this chapter, we have presented an overview of microfluidic enzyme-linked immunosorbent assay (ELISA) by first introducing the principle of immunoassay, ELISA, and microfabricated devices, followed by a discussion of microfabrication technology and the characterization of microfluidic components. Significant advances in laboratory technology are contributing to the further understanding of microfluidic function, surface modification and immobilization, which lead to the development of improved biomolecule detection methods and prospective applications. For the future, the exploitation of more robust-manufacturing processes and integrated assay systems in an automatic fashion with much reduced assay time and reagent consumption will allow for the effective detection and quantification of biological agents that are of interest in medical diagnostics, food safety surveillance, and environmental monitoring.
This letter describes the fabrication of three-dimensional particulate-like hydrogel microstructures using a combination of soft lithography and volume expansion induced self-folding. Bilayer structures are produced by solvent casting and photocuring of liquid resins. They curl into three-dimensional (3D) structures upon contacting with water due to differential swelling of the two layers. The curvature can be controlled by adjusting the polymer composition of the primary swelling layer. A simple semiempirical mathematical model is used to predict this self-folding behavior. By designing the two-dimensional (2D) shapes of the bilayers, this technique can lead to complicated 3D microstructures.
Highly ordered arrays of stretched DNA molecules were generated over the millimeter scale by using a modified molecular combing method and soft lithography. Topological micropatterning on polydimethyl siloxane stamps was used to mediate the dynamic assembly of DNA molecules into arranged nonostrand arrays. These arrays consisted of either short nanostrands of several micrometers with fixed length and orientation or long nanostrands up to several hundred micrometers in length. The nanostrand arrays were transferred onto flat solid surfaces by contact printing, allowing for the creation of more complex patterns. This technique has potential applications for the construction of next-generation DNA chips and functional circuits of DNA-based 1D nanostructures.
A novel biologically benign technique was developed to produce three-dimensional tissue engineering scaffolds with well-defined structure. Photolithography was used to design and pattern a planar scaffold skeletal structure on a photoresist (SU-8), and a variety of microembossing processes including sacrificial layer embossing and bilayer embossing were developed to transfer the skeletal pattern to the poly(DL-lactide-co-glycolide) substrate as scaffold skeletons. Subcritical carbon dioxide was then introduced to assemble these skeletons to a three-dimensional scaffold at a low temperature. Compared with conventional scaffolds, which have a broad pore size distribution and varying pore geometry, these microfabricated scaffolds have a uniform and well-defined geometry and structure. This uniformity of structural parameters allows for the studies of cell attachment, spreading, and proliferation in scaffolds in a controlled and logical manner. The cytocompatibility of these microfabricated scaffolds was tested by seeding three different cell lines with different morphologies and growth patterns into these scaffolds. All three cell lines attached well to the scaffolds and grew to high densities as observed with scanning electron microscopy. This study demonstrates a controllable method to fabricate tissue scaffolds with a well-defined 3D architecture that can be used to better elucidate the effect of structure parameters such as pore geometry and pore size on tissue growth in 3D scaffolds.
This paper presents an integrated microfluidic device on a compact disk (CD) that performs an enzyme-linked immunosorbent assay (ELISA) for rat IgG from a hybridoma cell culture. Centrifugal and capillary forces were used to control the flow sequence of different solutions involved in the ELISA process. The microfluidic device was fabricated on a plastic CD. Each step of the ELISA process was carried out automatically by controlling the rotation speed of the CD. The work on analysis of rat IgG from hybridoma culture showed that the microchip-based ELISA has the same detection range as the conventional method on the 96-well microtiter plate but has advantages such as less reagent consumption and shorter assay time over the conventional method.
The present work focused on the design of an assembled drug delivery system (DDS) to provide multifunctions, such as drug protection, self-regulated oscillatory release, and targeted uni-directional delivery by a bilayered self-folding gate and simple surface mucoadhesion. In this device, a pH-sensitive hydrogel together with a poly(hydroxyethyl methacrylate) (HEMA) barrier was used as a gate to control drug release. In addition, poly(HEMA) coated with poly(ethylene oxide)/poly(propylene oxide)/poly(ethylene oxide) (PEO-PPO-PEO) surfactant was utilized to enhance mucoadhesion on the device surface. The release profiles of two model drugs, acid orange 8 (AO8) and bovine serum albumin (BSA) were studied in this assembled system, which compared with the conventional drug-entrapped carriers and enteric-coating systems. Furthermore, targeted uni-directional release was demonstrated in a side-by-side diffusion cell. In conclusion, for such an assembled device, the poly(HEMA) layer not only affects the folding direction but also serves as a barrier to protect the model drugs. The release time can be controlled by the thickness of the bilayered gate and the drug reservoir. Due to the reversible swelling behavior of poly(methyacrylic acid-g-ethylene glycol) (p(MAA-g-EG)) gels, the bilayered gate can sense the environmental pH change and achieve an oscillatory release pattern. Moreover, the local targeting and uni-directional release have been successfully demonstrated in vitro.
A new technique, resin-gas injection, has been developed for bonding and surface modification of polymer microfluidic devices. This method can easily bond biochips with complex flow patterns. A cascade micromixer and a multichannel DNA sequencing chip were demonstrated experimentally. By adding surface modification agents, the interfacial free energy of the substrate with water can be controlled. Local modification of the channel surface can also be achieved through sequential resin-gas injection in conjunction with a masking technique. For application, this technique is used to form a layer of dry monolithic stationary hydrogel on the walls of a microchannel, serving as a sieving material for electrophoresis separation of DNA fragments. The reagent loading and the electrophoresis separation efficiency of this technique were compared experimentally with the conventional linear polymer solution method used in the microchannel-based DNA sequencing process. It is found that our method has the advantages of more user-friendly operation, easier and faster sample loading, but slightly less separation efficiency.