Search PubMed⌕ Search

Biomedical subjects

L J Thomas

Publications and source records attributed to L J Thomas.

At least 55 records · Page 3Linked to original sources

Risk factors for sudden death after acute myocardial infarction: two-year follow-up.

The risk of sudden coronary death after myocardial infarction (MI) was assessed in 533 patients who survived 10 days after MI and were followed for up to 24 months (mean 18) in the Multicenter Investigation of the Limitation of Infarct Size. Analysis of multiple clinical and laboratory variables determined before hospital discharge revealed that frequent ventricular premature beats (VPBs) (greater than or equal to 10/hour) on ambulatory electrocardiographic monitoring and left ventricular (LV) dysfunction (radionuclide LV ejection fraction less than or equal to 0.40) were independently significant markers of risk for subsequent sudden death believed to be the result of a primary ventricular arrhythmia. The incidence of sudden death was 18% in patients with both LV dysfunction and frequent VPBs (11 times that of patients with neither of these findings). Seventy-nine percent of all sudden deaths occurred within 7 months after the index MI. In 280 survivors reclassified 6 months after MI with regard to the presence or absence of frequent VPBs and LV dysfunction, these risk factors could not be associated with sudden coronary death over a further follow-up period of up to 18 months; the overall incidence of sudden cardiac death was low (1.4%) after 6 months. Thus, the presence of frequent VPBs in association with LV dysfunction early after MI identifies patients at high risk for sudden death over the next 7 months.

Aged↗

Comparison of left ventricular function and infarct size in patients with and without persistently positive technetium-99m pyrophosphate myocardial scintigrams after myocardial infarction: analysis of 357 patients.

One hundred nine patients with persistently positive technetium-99m pyrophosphate (Tc-99m-PPi) myocardial scintigrams 6 months after acute myocardial infarction (MI) (Group A) and 185 patients without such persistently positive scintigrams (Group B) were compared with regard to enzymatically determined infarct size, early and late measurements of left ventricular (LV) function determined by radionuclide ventriculography, and preceding clinical course during the 6 months after MI. The CK-MB-determined infarct size index in Group A (17.4 +/- 10.6 g-Eq/m2) did not differ significantly from that in Group B (16.0 +/- 14.6 g-Eq/m2). Similarly, myocardial infarct areas in the 2 groups, determined by planimetry of acute Tc-99m-PPi scintigrams in those patients with well-localized 3+ or 4+ anterior pyrophosphate uptake, were not significantly different (35.7 +/- 13.4 vs 34.4 +/- 13.1 cm2, respectively). However, patients in Group A had significantly lower LV ejection fractions than those in Group B, both within 18 hours of the onset of MI (0.42 +/- 0.14 vs 0.49 +/- 0.14, p less than 0.01) and at 3 months after MI, both at rest (0.42 +/- 0.14 vs 0.51 +/- 0.14, p less than 0.01) and at maximal symptom-limited supine bicycle exercise (0.44 +/- 0.17 vs 0.51 +/- 0.17, p less than 0.01). Peak exercise levels achieved in the 2 groups were not significantly different. Furthermore, patients in Group A demonstrated a greater incidence of congestive heart failure during the initial hospital admission (41 vs 24%; p less than 0.01) and a greater requirement for digoxin (p less than 0.05) and furosemide (p less than 0.01) after discharge.(ABSTRACT TRUNCATED AT 250 WORDS)

Ambulatory Care↗

The implantation of a closed loop artificial beta cell in dogs.

1. Seven more diabetic dogs have been implanted with complete feedback artificial beta cell systems. 2. All of these units have functioned fairly well with maintenance of the animals in the process of extensive surgery but none have brought the animals under complete control. 3. The glucose sensors are at fault because they are insensitive to the glucose levels giving readings that appear functionally to be about half of true readings. 4. The defective function of the electrodes has been traced to the design of the electrodes which does not take the Km of glucose oxidase for oxygen into consideration. 5. Redesign of the electrodes by inclusion of a convertor for pO2 based on the reading of the reference electrodes leads to a reliable glucose reading. 6. It is recommended that all glucose electrodes which are based on glucose oxidase be redesigned to include an oxygen electrode to permit correction of the readings to account for the effect of local pO2 on their function.

Alloxan↗

Non-accidental injury: a two-year study in central Liverpool.

In the two years following the implementation in Liverpool of a case conference system for dealing with non-accidental injury to children, 76 children were discussed at 73 such conferences. Factors in both the children and their families were identified as predisposing to non-accidental injury, notably male sex, illegitimacy, low birthweight, previous injuries in the children, the mothers having become pregnant at an early age, and the families having environmental stress factors. The evolving rôle of the case conference system in providing support for affected families is discussed.

Age Factors↗

Continuous extracorporeal monitoring of animal blood using the glucose electrode.

A continuous extracorporeal monitoring system for blood glucose employing an electrochemical sensor is described. The sensor, about the size of a nickel, is rapid, is specific for glucose, generates its own power, and consists of two galvanic oxygen electrodes. Over one oxygen electrode is affixed a plastic matrix to which glucose oxidase is covalently bound; a blank matrix is over the other, which serves as a reference. Oxygen is consumed in the glucose-oxidase-containing matrix, decreasing the current from the underlying oxygen electrode. The current decrease is nonlinearly proportional to the glucose concentration. The sensor is clamped between small blocks of plastic fitted with inlet and outlet nipples so that blood pumped from the animal passes over the two electrodes and thence to an automated chemical analysis for comparison. Blood is collected and anticoagulant added in a double-lumen catheter. Blood is withdrawn at the rate of 1 cc. per hour. Results obtained by use of the system in rabbits are reported. The capacity of the system to continuously monitor changes in blood glucose produced by repeated glucose tolerances is shown in hypo-, normo-, and hyperglycemic animals. Some properties of the system and its calibration are discussed.

Animals↗

A sensitive and reproducible assay for the quantitation of erythrophagocytosis and its correlation with reduction in tritiated thymidine uptake in a tumor target cell system modified by immunoenhancing or immunosuppressive agents.

A new and sensitive assay procedure for studying erythrophagocytosis is described. The assay technique permits quantitation of the in vivo and in vitro effects of chemicals, hormones, and cell, or microbrial products, on the level of phagocytic activation of glass-adherent cells. The effect of intraperitoneal injection of BCG, Zymosan, Vitamin A, B. pertussis, cortisone, estrone, and thioglycollate on phagocytic activation of peritoneal exudate cells harvested from two days up to 28 days following drug injection was examined by this assay. Erythrophagocytosis was compared to the effect of "activated" spleen cells on tritiated thymidine uptake of a tumor target cell suspension.

Animals↗

Insulin from individual isolated islets of Langerhans 2. Effect of glucose in varying concentrations.

1. Insulin secretion of individual isolated islets of Langerhans from mice, determined at 15 second intervals, demonstrated a pulsatile pattern. Glucose stimulated increased amounts of insulin to be released from these individual islets. 2. Insulin secretion of individual isolated mouse islets of Langerhans incubated for 5-15 minute intervals showed a direct relationship to concentration. There was negligible "leakage" in the absence of glucose. 3. Serial determination of insulin release from individual islets at 15 sec. intervals also demonstrated augmented magnitude of insulin release in response to increase of glucose in the medium. More important, a pulsatile pattern of insulin release was evident, which may be related to inherent physiological periodicity of islet physiology as also reflected in the pattern of islet electrical activity.

Animals↗

Prototype for an implantable micropump powdered by piezoelectric disk benders.

A prototype for an implantable mul pump to be used in an artificial pancreas has been constructed, in which pressure is developed by a bellows formed from 2 apposed piezoelectric disk benders connected to the high impedance secondary winding of aminiature transformer. Active valving, properly phased, is achieved by a miniature solenoid valve connected in series with the transformer primary winding and a rectangular wave generator.

Artificial Organs↗