Search PubMed⌕ Search

Biomedical subjects

L J Crouse

Publications and source records attributed to L J Crouse.

22 records · Page 2Linked to original sources

Early evaluation of cardiac injury by two-dimensional echocardiography in patients suffering blunt chest trauma.

The availability of two-dimensional echocardiography as a clinical tool has led to an interest in its applicability, usefulness, and reliability in the evaluation of blunt cardiac trauma. Forty patients who sustained objective evidence of blunt chest trauma were evaluated at our institution using serial ECGs, creatine phosphokinase (CPK) isoenzyme determinations, and two-dimensional echocardiography. Twenty patients (50%) manifested evidence of cardiac injury as demonstrated by abnormal ECGs, elevated CPK isoenzymes, or abnormal echocardiograms. Nine (23%) patients had abnormal echocardiograms with findings of pericardial effusions in four, chamber enlargement in three, and echodense areas of the right ventricle in two. There was no correlation with ECG changes or the presence of CPK isoenzymes. Based on these observations we believe echocardiography can be used as a noninvasive modality to complement other clinical tools in the detection of blunt cardiac injury.

Adult↗

Elimination of artifactual acetaldehyde in the measurement of human blood acetaldehyde by the use of polyethylene glycol and sodium azide: normal blood acetaldehyde levels in the dog and human after ethanol.

A new procedure is described for the preparation of human blood samples for analysis of acetaldehyde and ethanol by head space gas chromatography. High concentrations of polyethylene glycol were used to remove the hemoglobin and approximately 50% of the plasma protein. Artifactual formation of acetaldehyde from ethanol was inhibited by sodium azide. Using this method, no artifactual acetaldehyde was detectable in human, dog, sheep, and rat blood when spiked with ethanol in final concentrations of 65 mM. The recovery of added acetaldehyde was approximately 80% for human dog, and sheep blood, whereas it was only 30% for rat blood. Following ethanol administration, acetaldehyde levels were determined in blood taken from the pulmonary artery and descending aorta of the dog and human, and also from the hepatic vein of the latter. The relative blood acetaldehyde concentrations at these sites were hepatic vein greater than pulmonary artery greater than descending aorta.

Acetaldehyde↗

Stress echocardiography: technical considerations.

Stress echocardiography has evolved into a widely practiced and accepted method for the noninvasive assessment of the status of the coronary anatomy. Furthermore, this modality incorporates the ability to assess left ventricular function, valvular structure and function, intracardiac masses, the pericardium, and hemodynamics. The extent to which this tool can reliably provide useful clinical information is dependent, in part, on optimal performance. The purpose of this report is to provide an overview of those technical considerations that can contribute to the successful operation of a stress echocardiography laboratory. Consideration is given to personnel qualifications, functional requirements of the digital acquisition/storage/replay system, functional integration of the various hardware components, characteristics of the software, physical layout of the facility, and alternatives to treadmill exercise as the stressor. A thorough understanding of the physiologic basis of stress echocardiography, coupled with optimization of resources used in its performance, enable this tool to be an extraordinarily useful and cost-efficient method for comprehensive cardiovascular assessment.

Contrast Media↗