Search PubMed⌕ Search

Biomedical subjects

L Harrison

Publications and source records attributed to L Harrison.

At least 163 records · Page 9Linked to original sources

The sock electrode array: a tool for determining global epicardial activation during unstable arrhythmias.

The conventional technique for mapping the sequence of epicardial activation uses a hand-held electrode moved over the heart to record from a number of epicardial sites one at a time, and requires 5-15 minutes to record from 50 or more sites distributed over the entire ventricular epicardium. This method is inadequate for arrhythmias that are transient or vary from beat to beat. To overcome these limitations the "sock electrode array," a contour-fitting sock containing 26 or 52 electrodes, has been developed. The nylon mesh sock is pulled over the heart and permits simultaneous recording of potentials from electrodes distributed over the entire ventricular epicardium. The electrograms are recorded and converted to digital form for computer generation of isochronous maps. Most of the epicardial activation sequence derived from the sock electrode were compared to those obtained by the hand-held electrode in six normal dogs during sinus rhythm and ventricular pacing. The sequence of local activation times acquired by both methods showed similar areas of early and late activation and comparable isochronous maps. The hand-held electrode technique required 10-15 minutes for data acquisition and another 15-30 minutes for analysis. The sock electrode array allowed electrograms from 26 epicardial electrodes to be recorded simultaneously during one cardiac cycle and computer generated isochronous maps could be displayed within 10 minutes. This method allows rapid recording and analysis of epicardial electrical phenomena and should meet the time constraints imposed during the intraoperative study of ventricular tachyarrhythmias in patients.

Animals↗

Effects of vitamin D on the absorption and retention of lead.

A relationship between lead retention and vitamin D has been recognized for many years, but the reasons for this association remained unknown. In rats, the manipulation of dietary vitamin D content had no significant effect on the absorption of lead from isolated gut loops and parenteral vitamin D stimulation did not affect lead absorption in rachitic animals. In contrast, dietary vitamin D deficiency and repletion resulted in increased absorption in intact animals due to prolonged gastrointestinal transit time. Both dietary vitamin D deficiency and repletion were associated with decreased body retention of radiolead given intravenously. Further, single doses of parenteral vitamin D administered to animals previously given tracer radiolead resulted in a dose-related enhancement of lead excretion and changes in tissue lead content.

Animals↗

Cryosurgical ablation of the atrioventricular node-His bundle: long-term follow-up and properties of the junctional pacemaker.

We used a cryosurgical technique to ablate the atrioventricular (AV) node-His bundle in twenty-two selected patients with disabling supraventricular tachyarrhythmias unresponsive to medical management. Successful AV block was achieved in seventeen. There was no intraoperative mortality and significant surgical complications were not encountered. Electrophysiologic studies performed 7-10 days after surgery revealed that the subsidiary pacemaker had a narrow QRS complex morphology and a mean cycle length of 1244 msec. Isoproterenol (1-4 microgram/min i.v.) significantly increased (p less than 0.01) the rate of the subsidiary pacemaker (mean maximum response 1008.3 msec); atropine (2 mg i.v.) had no effect on its rate. The cycle length of the subsidiary pacemaker during long-term follow-up (mean 14.8 months) showed a small but significant (p = 0.024) increase (mean cycle length 1430 msec). Treadmill exercise in seven patients did not result in the subsidiary pacemaker exceeding the rate of the implanted demand pacemaker set at 70 beats/min. The properties of the subsidiary pacemaker suggest an intra-Hisian site of impulse formation.

Adult↗

A microcomputer-based research system for the optical analysis of agar-cultured micro-organism colonies.

A system which has been developed for the automatic of agar-cultured microorganism colonies is described. A camera of the line-scanning type is used to scan the plates and details of the hardware and software development are explained. Flow diagrams are included which illustrate the operation of the system, but, as yet, no results are available. The prototype machine is undergoing evaluation testing.

Agar↗

Reaction of the myocardium to cryosurgery: electrophysiology and arrhythmogenic potential.

The acute and chronic electrophysiological effects of a cryolesion produced in the left ventricle were studied in six dogs. All dogs had frequent ventricular premature beats (VPB) and five of six dogs had ventricular tachycardia during the first 4 days after the cryolesion; only one of the six dogs continued to have VPBs after 1 week, and this dog had identical VPBs before the creation of the cryolesion. Neither control dog had VPBs. Two additional dogs underwent epicardial and transmural mapping studies immediately after production of a cryolesion. VPBs in these animals were shown to originate at the border of the cryolesion. Epicardial activation sequence during normal sinus rhythm was not altered by the chronic cryolesion. The border zone of the chronic cryolesion was sharply demarcated with normal potentials recorded outside of the lesion and "extrinsic" potentials recorded within.

Animals↗

Reentry within the atrioventricular node: surgical cure with preservation of atrioventricular conduction.

Paroxysmal supraventricular tachycardia (PSVT) is commonly caused by reentry within the atrioventricular (AV) node. This arrhythmia was abolished by operative dissection of the AV junction in a patient with disabling tachycardia that was not controlled by drugs. The operation was intended to create complete AV block, but AV conduction persisted after surgery. An electrophysiologic study 1 year after the operation revealed that the operation changed AV conduction in both the antegrade and retrograde directions, which may explain the absence of tachycardia. The patient has been free of arrhythmias for 18 months.

Atrioventricular Node↗

Cryoablation of drug-resistant ventricular tachycardia in a patient with a variant of scleroderma.

A 37-year-old man with a benign variant of scleroderma (CRST syndrome: calcinosis circumscripta, Raynaud's phenomenon, sclerodactyly, and telangiectasia) presented with recurrent ventricular tachycardia. Preoperative electrophysiologic study suggested that the mechanism of tachycardia was an ectopic pacemaker focus in the right ventricle. Right ventricular dilatation, tricuspid insufficiency, normal pulmonary pressures, and normal coronary arteries were also demonstrated. At surgery, epicardial mapping localized the site of origin of ventricular tachycardia to the anterior right ventricle near the crista supraventricular. Intramural recordings of the site of tachycardia demonstrated autonomous activity unreflected on the peripheral ECG during brief periods of sinus rhythm. Local epicardial cooling of this area with a cryoprobe promptly terminated ventricular tachycardia with resumption of tachycardia on warming. The focus was ablated by freezing the area at -60 degrees C. The patient remained free of dysrhythmia on no anti-arrhythmic agents for eight months at which time he had a single recurrence of ventricular tachycardia from a different site in the right ventricle. This technique offers a method for ablating sites of dysrhythmia arising in diffusely diseased myocardium.

Adult↗

Digital ultrasonic imaging with microprocessor manipulation.

The author describes the development of a digital scan converter system which accepts ultrasonic B-scans in "oscilloscope" format and displays them in video format. The system involves the use of a microprocessor, the function of which is outlined in the paper. A brief comparison with a system employing a scan converter tube is given.

Analog-Digital Conversion↗

Effects of calcium on the absorption and retention of lead.

An inverse relationship between lead retention and dietary calcium content has been known to exist for many years, but the reasons for this association remained unknown. In rats, the manipulation of dietary calcium had no significant effect upon the absorption of lead, but calcium-deprived animals had decreased excretion and thus increased body retention of lead. Intraluminal calcium decreased the absorption of test doses of lead from the small intestine in a dose-related manner. We postulated that this occurred because the two metals competed for similar binding sites on intestinal mucosal proteins which were important in the absorptive process. In vivo, lead bound to two heat-stable intestinal mucosal fractions which have been shown to bind calcium. Although more lead bound to the higher molecular weight fraction and more calcium bound to the lower molecular weight vitamin D-induced CaBP, substantial amounts of lead and calcium were found in both fractions. Further, the addition of calcium to test doses of lead markedly diminished the amount of lead bound by both fractions. Shared binding sites on absorptive proteins would explain why dietary calcium decreases lead absorption.

Animals↗

Effects of iron on the absorption and retention of lead.

An inverse relationship between lead retention and dietary iron content has been suspected for many years, but the reasons for this association remained unknown. In rats, the state of body iron repletion had significant effects on the absorption of lead but no effect on lead excretion. Intraluminal iron decreased the absorption of test doses of lead from the small intestine in a dose-related manner. We postulated that this occurred because the two metals competed for similar binding sites on intestinal mucosal proteins which were important in the absorptive process. In vivo, both lead and iron bound to two heat-stable intestinal mucosal fractions, particularly the higher-molecular-weight fraction. Addition of iron to test doses of lead markedly diminished the amount of lead bound by the high-molecular-weight fraction. Further investigation revealed that this fraction, with a molecular weight of approximately 370,000, bound both lead and iron. Shared binding sites on this protein may explain why dietary iron decreased lead absorption and iron deficiency increased it.

Animals↗

Cryosurgical ablation of the A-V node-His bundle: a new method for producing A-V block.

A cryosurgical instrument was used to ablate atrioventricular conduction. The procedure was carried out in 20 dogs and subsequently in three patients with drug resistant, life-threatening supraventricular tachycardias. In patients, the cryosurgical unit lowered the temperature of the His bundle area to 0 degrees C, effecting complete but reversible heart block. Rewarming resulted in resumption of normal atrioventricular conduction. The His bundle region then was cooled to -60 degrees C; complete heart block was produced with two or more 90-120 second freezes. Postoperative evaluations revealed persistent atrioventricular conduction block. The lesion showed no tendency to rupture, form aneurysm, or interfere with valvular function. In the clinical cases, postoperative studies demonstrated a stable pacemaker arising proximal to the branching portion of the His bundle. A potential application of the cryosurgical technique might be ablation of sites of dysrhythmia (i.e., ectopic foci, re-entry circuits, accessory pathways).

Adult↗

Cryosurgical ablation of accessory atrioventricular connections: a method for correction of the pre-excitation syndrome.

Cryothermia, a new technique for definitive treatment of the pre-excitation syndrome, is described in two patients. The first patient presented with a normal P-R interval with a delta wave and reciprocating tachycardia. Preoperative electrophysiologic study suggested a free-wall atrioventricular connection on the left posterior atrioventricular (A-V) groove. At surgery, epicardial mapping confirmed the site of pre-excitation on the posterior left ventricular (LV) wall. An electrogram arising from the accessory pathway (AP) was recorded at the site of earliest ventricular activation. Interatrial delay combined with an apparently long accessory pathway to the ventricle caused the P-R interval to appear normal. Local pressure abolished pre-excitation. The site of early ventricular activation was cooled to -60 degrees C with a specially designed cryoprobe. All evidence of pre-excitation and arrhythmias disappeared. The second patient presented with a refractory reciprocating tachycardia and was found to have an AP in the septum capable of only retrograde conduction. Retrograde conduction was abolished by applying a temperature of 0 degrees C to the anulus at this site during tachycardia. Conduction over the AP and reciprocating tachycardia returned with rewarming. Ablation of the AP was obtained by applying a temperature of -60 degrees C for 90 seconds on two occasions to the same area. The His bundle was not injured.

Adult↗