Search PubMed⌕ Search

Biomedical subjects

L G Hanson

Publications and source records attributed to L G Hanson.

4 recordsLinked to original sources

Perfusion quantification using Gaussian process deconvolution.

The quantification of perfusion using dynamic susceptibility contrast MRI (DSC-MRI) requires deconvolution to obtain the residual impulse response function (IRF). In this work, a method using the Gaussian process for deconvolution (GPD) is proposed. The fact that the IRF is smooth is incorporated as a constraint in the method. The GPD method, which automatically estimates the noise level in each voxel, has the advantage that model parameters are optimized automatically. The GPD is compared to singular value decomposition (SVD) using a common threshold for the singular values, and to SVD using a threshold optimized according to the noise level in each voxel. The comparison is carried out using artificial data as well as data from healthy volunteers. It is shown that GPD is comparable to SVD with a variable optimized threshold when determining the maximum of the IRF, which is directly related to the perfusion. GPD provides a better estimate of the entire IRF. As the signal-to-noise ratio (SNR) increases or the time resolution of the measurements increases, GPD is shown to be superior to SVD. This is also found for large distribution volumes.

Cerebrovascular Circulation↗

Evaluation of CA1 damage using single-voxel 1H-MRS and un-biased stereology: Can non-invasive measures of N-acetyl-asparate following global ischemia be used as a reliable measure of neuronal damage?

Global brain ischemia provoked by transient occlusion of the carotid arteries (2VO) in gerbils results in a severe loss of neurons in the hippocampal CA1 region. We measured the concentration of the neuron specific N-acetyl-aspartate, [NAA], in the gerbil dorsal hippocampus by proton MR spectroscopy (1H-MRS) in situ, and HPLC, 4 days after global ischemia. The [NAA] was correlated with graded hippocampus damage scoring and stereologically determined neuronal density. A basal hippocampal [NAA] of 8.37+/-0.10 and 9.81+/-0.44 mmol/l were found from HPLC and 1H-MRS, respectively. HPLC measurements of [NAA] obtained from hippocampus 4 days after 2VO showed a 20% reduction in the [NAA] following 4 min of ischemia (P<0.001). 1H-MRS measurements on gerbils subjected to 4 or 8 min of ischemia showed a similar 24% decline in the [NAA] (P<0.05). Thus, there was correlation between the HPLC and 1H-MRS determined NAA decline. There was also a significant correlation between 1H-MRS [NAA] and the corresponding reduction in CA1 neuronal density (P<0.004). In summary our findings show that single voxel 1H-MRS can be used as a supplement to histological evaluation of neuronal injury in studies after global brain ischemia. Accordingly, volume selective spectroscopy has a potential for assessment of neuroprotective therapeutic compounds/strategies with respect to neuronal rescue for delayed ischemic brain damage.

Animals↗

Optimal voxel size for measuring global gray and white matter proton metabolite concentrations using chemical shift imaging.

Quantification of gray and white matter levels of spectroscopically visible metabolites can provide important insights into brain development and pathological conditions. Chemical shift imaging offers a gain in efficiency for estimation of global gray and white matter metabolite concentrations compared to single voxel methods. In the present study, the optimal voxel size is calculated from segmented human brain data and accompanying field maps. The optimal voxel size is found to be approximately 8 cc, but a wide range of values, 4-64 cc, can be chosen with little increase in estimated concentration error (<15%). Magn Reson Med 44:10-18, 2000.

Body Water↗

Reconstruction strategy for echo planar spectroscopy and its application to partially undersampled imaging.

The most commonly encountered form of echo planar spectroscopy involves oscillating gradients in one spatial dimension during readout. Data are consequently not sampled on a Cartesian grid. A fast gridding algorithm applicable to this particular situation is presented. The method is optimal, i.e., it performs as well as the full discrete Fourier transform for band limited signals while allowing for use of the fast Fourier transform. The method is demonstrated for reconstruction of data that are partially undersampled in the time domain. The advantages of undersampling are lower hardware requirements or fewer interleaves per acquisition. The method is of particular interest when large bandwidths are needed (e.g., for high field scanning) and for scanners with limited gradient performance. The unavoidable artifacts resulting from undersampling are demonstrated to be acceptable for spectroscopy with long echo times.

Algorithms↗