Search PubMed⌕ Search

Biomedical subjects

L F Satler

Publications and source records attributed to L F Satler.

At least 37 records · Page 2Linked to original sources

Are we making progress with percutaneous saphenous vein graft treatment? A comparison of 1990 to 1994 and 1995 to 1998 results.

OBJECTIVES: We sought to determine whether strategies to reduce procedural distal embolization and late repeat revascularization have resulted in more favorable outcomes after saphenous vein graft (SVG) angioplasty. BACKGROUND: Angioplasty of SVG lesions has been associated with frequent procedural and late cardiac events. Therefore, evolving strategies have been attempted to improve outcomes after SVG angioplasty. METHODS: We compared our earlier experience (1990 to 1994) of 1,055 patients with 1,412 SVG lesions with a recent group (1995 to 1998) of 964 patients with 1,315 lesions. RESULTS: Baseline characteristics were similar between the groups. However, there were significantly more unfavorable lesion characteristics (older, longer and significantly more degenerated SVGs) in the recent series. Between the two periods, there was decreased use ofatheroablative devices, whereas stent use increased. The procedural success rates (96.6% vs. 96.1%) were similar. However, one-year outcome (event-free survival) was significantly improved in the more recent experience (70.7% vs. 59.1%, p < 0.0001), especially late mortality (6.1% vs. 11.3%, p < 0.0001). Multivariate analysis showed stent use to be the only protective variable for both periods. CONCLUSIONS: This study shows that despite higher risk lesions, strategies to reduce distal embolization have maintained high procedural success. Late cardiac events, including mortality, have also been substantially reduced.

Aged↗

Vascular complications after percutaneous coronary interventions following hemostasis with manual compression versus arteriotomy closure devices.

OBJECTIVES: We evaluated the vascular complications after hemostasis with arteriotomy closure devices (ACD) versus manual compression after percutaneous coronary interventions (PCI). BACKGROUND: Previous clinical studies have indicated that ACD can be used for achievement of hemostasis and early ambulation after PCI. This study investigated the safety of ACD in achieving hemostasis after PCI compared with manual compression in a large cohort of consecutive patients. METHODS: A total of 5,093 patients were followed after PCI was performed with the transfemoral approach. Univariate and multivariate analysis were used to identify the predictors of vascular complications with ACD (n = 516) or with manual compression (n = 5,892) as a hemostasis option after sheath removal. RESULTS: The use of ACD was associated with a more frequent occurrence of hematoma compared with manual compression (9.3 vs. 5.1%, p < 0.001). There was also a higher rate of significant hematocrit drop (>15%) with ACD versus manual compression (5.2% vs. 2.5%, p < 0.001). Similar rates of pseudoaneurysm and arteriovenous fistulae were noted with either hemostasis technique. Vascular surgical repair at the access site was required more often with ACD versus manual compression (2.5 vs. 1.5%, p = 0.03). CONCLUSIONS: In this early experience with ACD after PCI, their use was associated with higher vascular complication rates than hemostasis with manual compression.

Aged↗

The effect of intracoronary radiation for the treatment of recurrent in-stent restenosis in patients with chronic renal failure.

OBJECTIVES: This study was designed to analyze the in-hospital and six-month clinical and angiographic outcomes of patients with chronic renal failure (CRF) treated with intracoronary radiation for the prevention of recurrence of in-stent restenosis. BACKGROUND: Patients with CRF are at a higher risk than the general population for accelerated atherosclerotic cardiovascular disease and for restenosis after percutaneous coronary intervention. Previous studies have shown the effectiveness of both beta and gamma radiation in preventing recurrent restenosis in patients with in-stent restenosis. METHODS: We studied the in-hospital and six-month clinical and angiographic outcomes of 118 patients with CRF and 481 consecutive patients without CRF who were treated with intracoronary radiation for the prevention of recurrence of in-stent restenosis in native coronaries and saphenous vein grafts. RESULTS: Patients with CRF were usually older, women, hypertensive and diabetic, with multivessel disease and with reduced left ventricular function. In-hospital outcome for patients with CRF was marred by a higher incidence of death, non-Q-wave myocardial infarction and major vascular and bleeding complications. At six-month follow-up, the mortality rate was higher in patients with CRF, 7.6% compared with 1.9% in non-CRF patients (p = 0.003). Restenosis, target lesion revascularization (TLR) and target vessel revascularization (TVR) rates were similar in the two groups. In patients with CRF, radiation therapy compared to placebo reduced restenosis (53.8% vs. 22.6%, p = 0.04), TLR (71.4% vs. 15.3%, p < 0.0001) and TVR (78.6% vs. 23.7%, p = 0.0002). CONCLUSIONS: Intracoronary radiation for the prevention of recurrence of in-stent restenosis achieved similar rates of restenosis and revascularization procedures in patients with and without CRF. Despite this benefit, patients with renal dysfunction continued to have significantly higher in-hospital and six-month adverse outcomes.

Aged↗

Treatment of focal in-stent restenosis with balloon angioplasty alone versus stenting: Short- and long-term results.

BACKGROUND: Although both percutaneous transluminal coronary angioplasty (PTCA) and additional stenting can be used for the treatment for focal in-stent restenosis (ISR), no large-scale comparative data on the clinical outcomes after these interventional procedures have been reported. METHODS: In the current study we compared the in-hospital and long-term clinical results of PTCA alone (n = 266 patients, n = 364 lesions) versus stenting (n = 135 patients, n = 161 lesions) for the treatment of focal ISR, defined as a lesion length less than or equal to 10 mm. RESULTS: There were significantly more diabetic patients in the PTCA group than in the stent group (36% vs 26%, P =.04), but other baseline characteristics were similar. Lesion length and preprocedure minimal lumen diameter (MLD) were also similar in the two groups, but the stent group had a larger reference vessel diameter (3.40 +/- 0.73 mm vs 2.99 +/- 0.68 mm, P <.001). Stenting achieved a larger postprocedure MLD than PTCA did (2.95 +/- 0.95 mm vs 2.23 +/- 0.60 mm, P <.001) and a smaller residual diameter stenosis (11% +/- 15% vs 23% +/- 16%, P =.04). Angiographic success was achieved in all cases. The rate of death/Q-wave infarction of urgent revascularization was higher with PTCA than with stent (5.6% vs 0.7%, P =.02). Postprocedure creatine kinase myocardial band enzyme elevation >5 times normal was more frequent with stent (18.5% vs 9.7%, P =.05). At 1 year the two interventional strategies had similar cumulative mortality (4.6% PTCA vs 5.1% stent, P not significant) and target lesion revascularization rate (24.6% PTCA vs 26.5% stent, P not significant). By multivariate analysis, the sole predictor of target lesion revascularization was diabetes (odds ratio 2.4, 95% confidence intervals 1.2-4.7, P =.01). CONCLUSION: Repeat stenting for the treatment of focal ISR had a higher postprocedure creatine kinase myocardial band elevation rate and similar long-term clinical results compared with PTCA alone.

Aged↗

The contribution of "mechanical" problems to in-stent restenosis: An intravascular ultrasonographic analysis of 1090 consecutive in-stent restenosis lesions.

OBJECTIVES: Serial intravascular ultrasonographic (IVUS) studies have shown that in-stent restenosis is the result of intimal hyperplasia (IH). However, routine preintervention IVUS imaging has suggested that many restenotic stents were inadequately deployed. The purpose of this IVUS study was to determine the incidence of mechanical problems contributing to in-stent restenosis (ISR). METHODS: Between April 1994 and June 2000, 1090 patients with ISR were treated at the Washington Hospital Center. All underwent preintervention IVUS imaging. IVUS measurements included proximal and distal reference lumen areas and diameters; stent, minimum lumen, and IH (stent minus lumen) areas; and IH burden (IH/stent area). RESULTS: In 49 ISR lesions (4.5%), there were morphologic findings that contributed to the restenosis. These were termed mechanical complications. Examples include (1) missing the lesion (eg, an aorto-ostial stenosis), (2) stent "crush," and (3) having the stent stripped off the balloon during the implantation procedure. Excluding mechanical complications, stent underexpansion was common. In 20% of the ISR cases the stents had a cross-sectional area (CSA) at the site of the lesion <80% of the average reference lumen area. Twenty percent of lesions had a minimum stent area <5.0 mm(2) and an additional 18% had a minimum stent area of 5.0 to 6.0 mm(2). Twenty-four percent of lesions had an IH burden <60%. CONCLUSION: Mechanical problems related to stent deployment procedures contribute to a significant minority of ISR lesions (approximately 25%).

Coronary Stenosis↗

Carotid artery stenting in patients with high-risk anatomy for carotid endarterectomy.

PURPOSE: To report the results of carotid artery stenting (CAS) in patients considered to have high-risk anatomical characteristics for carotid endarterectomy. METHODS: CAS was performed in 39 carotid arteries of 37 consecutive patients (26 men; mean age 72 +/- 8 years, range 56-88) who met the criteria for high-risk surgical anatomy: previous ipsilateral carotid endarterectomy (20/39, 51.3%), common carotid bifurcation above the mandibular angle (5/39, 12.8%), contralateral carotid artery occlusion (15/39, 38.5%), or previous radiation therapy to the neck (1/39, 2.6%). Palmaz, Integra, or Wallstents were deployed via a percutaneous femoral artery access. Independent neurological evaluation was performed at specified time points, and a dedicated committee adjudicated all clinical events. RESULTS: Procedural success was 100%, with no major in-hospital complications. Neurological events were rare. Only 1 (2.6%) transient ischemic attack occurred prior to discharge; at 30 days, 1 (2.6%) additional minor stroke had been observed, giving a 2.6% cumulative 30-day "death plus any stroke" rate. Over a mean 11 +/- 6-month follow-up, 2 (5.4%) patients died of nonneurological causes, but there were no strokes. CONCLUSIONS: CAS is a viable endovascular revascularization technique that can be performed safely and effectively in patients with high-risk anatomy for carotid endarterectomy.

Aged↗

Transient contrast encephalopathy after carotid artery stenting.

PURPOSE: To report an unusual case of transient contrast encephalopathy arising after carotid artery stenting. CASE REPORT: An 82-year-old right-handed man with a recent history of transient ischemic events was admitted to the hospital for evaluation of carotid artery disease. During cerebral angiography, which identified a 90% right internal carotid artery stenosis, the patient received 25 mL of an ionic, low-osmolar contrast agent (ioxaglate) in each carotid artery. The following day he underwent successful carotid stenting, during which 180 mL of ioxaglate were used. He developed rapidly worsening confusion and left hemiparesis on the table. Noncontrast computed tomography showed marked cortical enhancement and edema of the right cerebral hemisphere in the distribution of the right anterior and middle cerebral arteries. The patient improved rapidly and by day 2 was completely recovered; magnetic resonance imaging documented no cortical edema and normal sulci. One month after the procedure, he was well, with patent carotid arteries. CONCLUSIONS: Transient neurotoxicity after carotid interventions must be differentiated from massive cerebral infarction and hyperperfusion syndrome, but the prognosis is excellent. However, subsequent contrast studies in a patient with this complication should be undertaken with extreme caution.

Aged↗

Effect of preintervention plaque burden on subsequent intimal hyperplasia in stented coronary artery lesions.

We sought to determine if axial and circumferential distribution of plaque before stenting determines the axial and circumferential distribution of subsequent intimal hyperplasia (IH). We studied 22 patients with a single Palmaz-Schatz stent implanted in a native coronary artery, who underwent intravascular ultrasound (IVUS) imaging before intervention, after stenting, and at 6-month follow-up. For each lesion, 7 locations were analyzed: proximal and distal reference, proximal and distal edge of the stent, proximal and distal location within the body of the stent, and the articulation. Pre- and postintervention and follow-up image slices were precisely aligned and analyzed for pre- and postintervention plaque area and follow-up IH area and thickness. The location of maximal IH area was at or adjacent to the location of maximal preintervention plaque in 17 of 22 of the patients (77%). Similiarly, the circumferential distribution of IH at follow-up paralleled the eccentricity pattern of the native plaque burden in 69% (24 of 35 slices). Using multivariant analysis, the strongest predictor of IH was preintervention plaque area (p = 0.001). IH accumulates axially and circumferentially preferentially at the site of maximal preintervention plaque.

Angioplasty, Balloon, Coronary↗

Assessing a strategy of initial stand-alone extractional atherectomy followed by staged stent placement in degenerated saphenous vein graft lesions.

To assess whether a staged strategy (initial stand alone transluminal extraction atherectomy and coumadin therapy followed by stenting six weeks later) could reduce ischemic complications in degenerated saphenous vein graft (SVG) interventions, we studied 72 patients undergoing percutaneous interventions of degenerated SVG. Patients were divided into two groups; 28 were treated with a staged strategy (group I) and 44 with similar lesion characteristics were treated with a definitive initial procedure with transluminal extraction atherectomy +/- adjunctive balloon angioplasty and stenting (group II). Procedural success, major in-hospital complications (death, Q-wave myocardial infarction, and emergent coronary bypass surgery), and incidence of distal embolization were compared between the 2 groups. Procedural success was lower (92% vs 100%, p = 0.14) and major in-hospital complications were higher (0% vs 11%, p = 0.14) in group II. Distal embolization occurred in 11% of the patients in group I compared with 23% of the patients in group II (p = 0.19). At 6 week follow-up (group I), 9 patients (33%) had negative symptoms, 11 (41%) underwent stent implantation, 3 (11%) did not require any further therapy (without significant stenosis), and 4 (14%) had total occlusions. We therefore conclude that this staged strategy in degenerated SVG appears to reduce distal embolization but most importantly avoids major in-hospital complications, including any deaths either at the time of initial procedure or during the 6-week follow-up period.

Aged↗

The prognostic implications of further renal function deterioration within 48 h of interventional coronary procedures in patients with pre-existent chronic renal insufficiency.

BACKGROUND: Acute deterioration in renal function is a recognized complication after coronary angiography and intervention. OBJECTIVES: The goal of this study was to determine the impact on acute and long-term mortality and morbidity of contrast-induced deterioration in renal function after coronary intervention. METHODS: We studied 439 consecutive patients who had a baseline serum creatinine > or = 1.8 mg/dL (159.1 /micromol/L) who were not on dialysis who underwent percutaneous coronary intervention in a tertiary referral center. All patients were hydrated before the procedure, and almost all received ioxaglate meglumine; 161 (37%) patients had an increase in serum creatinine > or = 25% within 48 h or required dialysis and 278 (63%) did not. In-hospital and out-of-hospital clinical events (death, myocardial infarction, repeat revascularization) were assessed by source documentation. RESULTS: Independent predictors of renal function deterioration were left ventricular ejection fraction (p = 0.02) and contrast volume (p = 0.01). In-hospital mortality was 14.9% for patients with further renal function deterioration versus 4.9% for patients with no creatinine increase (p = 0.001); other complications were also more frequent. Thirty-one patients required hemodialysis; their in-hospital mortality was 22.6%. Four patients were discharged on chronic dialysis. The cumulative one-year mortality was 45.2% for those who required dialysis, 35.4% for those who did not require dialysis and 19.4% for patients with no creatinine increase (p = 0.001). Independent predictors of one-year mortality were creatinine elevation (p = 0.0001), age (p = 0.03) and vein graft lesion location (p = 0.08). CONCLUSIONS: For patients with pre-existing renal insufficiency, renal function deterioration after coronary intervention is a marker for poor outcomes. This is especially true for patients who require dialysis.

Aged↗

Incidence, management, and outcome of coronary artery perforation during percutaneous coronary intervention.

We have analyzed the incidence, management, and outcome of 84 cases of coronary artery perforation in patients who underwent percutaneous coronary intervention at our institution. This complication was more frequent in female patients and in patients who underwent lesion modification with atheroablative devices. A total of 8 patients (9.5%) died after the procedure. They were usually older and had a higher incidence of cardiac tamponade; a larger percentage of these patients underwent emergency surgery than those who survived.

Adult↗

Mechanism of lumen enlargement during intracoronary stent implantation: an intravascular ultrasound study.

BACKGROUND: Intravascular ultrasound analysis has assessed mechanisms of lumen enlargement after nonstent interventions, but not after stenting. METHODS AND RESULTS: Preintervention and postintervention intravascular ultrasound was used to study 25 de novo native coronary lesions treated with single MultiLink stents without preatheroablation. External elastic membrane, lumen, and plaque and media (P&M) areas were measured every 1 mm to include the lesion and reference segments that were 5 mm proximal and distal to it. Lesion mean lumen area increased from 4.0+/-1.0 mm(2) before the intervention to 8.8+/-2.0 mm(2) after the intervention (P<0.0001) as a result of an increase in mean external elastic membrane area (14. 2+/-2.7 to 16.1+/-3.0 mm(2), P<0.0001) and a decrease in mean P&M area (10.2+/-2.2 to 7.2+/-1.8 mm(2), P<0.0001). The decrease in lesion P&M was accompanied by an increase in both proximal reference mean P&M (7.0+/-1.9 to 8.4+/-2.0 mm(2), P<0.0001) and distal reference mean P&M (5.8+/-2.1 to 7.2+/-2.1 mm(2), P<0.0001). Volumetric analysis showed an axial redistribution of plaque away from the center of the lesion toward the reference segments to increase the plaque burden in both the proximal and distal reference segments. Total (lesion plus reference) mean P&M decreased from 8. 6+/-2.1 to 7.5+/-1.8 mm(2) (P<0.0001). CONCLUSIONS: The mechanisms of lumen enlargement after stenting involved (1) significant axial redistribution of plaque from the lesion into the reference segments, (2) vessel expansion, and (3) either plaque embolization or compression.

Aged↗

Treatment of in-stent restenosis with excimer laser coronary angioplasty versus rotational atherectomy: comparative mechanisms and results.

BACKGROUND: Atheroablation yields improved clinical results for balloon angioplasty (percutaneous transluminal coronary angioplasty, PTCA) in the treatment of diffuse in-stent restenosis (ISR). METHODS AND RESULTS: We compared the mechanisms and clinical results of excimer laser coronary angioplasty (ELCA) versus rotational atherectomy (RA), both followed by adjunct PTCA; 119 patients (158 ISR lesions) were treated with ELCA+PTCA and 130 patients (161 ISR lesions) were treated with RA+PTCA. Quantitative coronary angiographic and planar intravascular ultrasound (IVUS) measurements were performed routinely. In addition, volumetric IVUS analysis to compare the mechanisms of lumen enlargement was performed in 28 patients with 30 lesions (16 ELCA+PTCA, 14 RA+PTCA). There were no significant between-group differences in preintervention or final postintervention quantitative coronary angiographic or planar IVUS measurements of luminal dimensions. Angiographic success and major in-hospital complications with the 2 techniques were also similar. Volumetric IVUS analysis showed significantly greater reduction in intimal hyperplasia volume after RA than after ELCA (43+/-14 versus 19+/-10 mm(3), P<0.001) because of a significantly higher ablation efficiency (90+/-10% versus 76+/-12%, P = 0.004). However, both interventional strategies had similar long-term clinical outcome; 1-year target lesion revascularization rate was 26% with ELCA+PTCA versus 28% with RA+PTCA (P = NS). CONCLUSIONS: Despite certain differences in the mechanisms of lumen enlargement, both ELCA+PTCA and RA+PTCA can be used to treat diffuse ISR with similar clinical results.

Angioplasty, Balloon, Coronary↗