Search PubMed⌕ Search

Biomedical subjects

L E Young

Publications and source records attributed to L E Young.

At least 37 records · Page 2Linked to original sources

Doppler ultrasonography and single-fiber laser Doppler flowmetry for measurement of hind limb blood flow in anesthetized horses.

OBJECTIVE: To use Doppler ultrasonography and single-fiber laser Doppler flowmetry (LDF) to evaluate blood flow in the dependent and nondependent hind limbs of anesthetized horses and to evaluate changes in femoral arterial blood flow and microvascular skeletal muscle perfusion in response to administration of phenylephrine hydrochloride or dobutamine hydrochloride. ANIMALS: 6 healthy adult horses. PROCEDURE: Horses were anesthetized and positioned in left lateral recumbency. Doppler ultrasonography was used to measure velocity and volumetric flow in the femoral vessels. Single-fiber LDF was used to measure relative microvascular perfusion at a single site in the semimembranosus muscles. Phenylephrine or dobutamine was then administered to decrease or increase femoral arterial blood flow, and changes in blood flow and microvascular perfusion were recorded. RESULTS: Administration of phenylephrine resulted in significant decreases in femoral arterial and venous blood flows and cardiac output and significant increases in mean aortic blood pressure, systemic vascular resistance, and PCV. Administration of dobutamine resulted in significant increases in femoral arterial blood flow, mean aortic blood pressure, and PCV. Significant changes in microvascular perfusion were not detected. CONCLUSION AND CLINICAL RELEVANCE: Results suggest that Doppler ultrasonography and single-fiber LDF can be used to study blood flows in the hind limbs of anesthetized horses. However, further studies are required to determine why changes in femoral arterial blood flows were not associated with changes in microvascular perfusion.

Anesthetics, Dissociative↗

Cardiac output measured by lithium dilution, thermodilution, and transesophageal Doppler echocardiography in anesthetized horses.

OBJECTIVE: To assess the suitability of lithium dilution as a method for measuring cardiac output in anesthetized horses, compared with thermodilution and transesophageal Doppler echocardiography. ANIMALS: 6 horses (3 Thoroughbreds, 3 crossbreeds). PROCEDURE: Cardiac output was measured in 6 anesthetized horses as lithium dilution cardiac output (LiDCO), thermodilution cardiac output (TDCO), and transesophageal Doppler echocardiographic cardiac output (DopplerCO). For the LiDCO measurements, lithium chloride was administered i.v., and cardiac output was derived from the arterial lithium dilution curve. Sodium nitroprusside, phenylephrine hydrochloride, and dobutamine hydrochloride were used to alter cardiac output. Experiments were divided into 4 periods. During each period, 3 LiDCO measurements, 3 DopplerCO measurements, and 3 sets of 3 TDCO measurements were obtained. RESULTS: 70 comparisons were made between LiDCO, DopplerCO, and triplicate TDCO measurements over a range of 10 to 43 L/min. The mean (+/- SD) of the differences of LiDCO - TDCO was -0.86 +/- 2.80 L/min; LiDCO = -1.90 + 1.05 TDCO (r = 0.94). The mean of the differences of DopplerCO - TDCO was 1.82 +/- 2.67 L/min; DopplerCO = 2.36 + 0.98 TDCO (r = 0.94). The mean of the differences of LiDCO - DopplerCO was -2.68 +/- 3.01 L/min; LiDCO = -2.53 + 0.99 DopplerCO (r = 0.93). CONCLUSIONS AND CLINICAL RELEVANCE: These results indicate that lithium dilution is a suitable method for measuring cardiac output in horses. As well as being accurate, it avoids the need for pulmonary artery catheterization and is quick and safe to use. Monitoring cardiac output during anesthesia in horses may help reduce the high anesthetic mortality in this species.

Animals↗

Effect of age and training on murmurs of atrioventricular valvular regurgitation in young thoroughbreds.

Cardiac auscultation was carried out on 111 Thoroughbred horses age 2-5 years to test the hypothesis that athletic training might influence the development of atrioventricular (AV) valve regurgitation in young Thoroughbreds. Murmurs of valvular regurgitation were identified and graded on a 1-6 scale. There were 2 sources of auscultation data: 1) 55 2-year-old horses that were examined by auscultation before training commenced and 9 months later when at race fitness; 2) 56 horses age 2-5 years that were examined on one occasion only (25 2-year-olds, 23 3-year-olds, five 4-year-olds and five 5-year olds). All horses in the second data set were in full training and racing regularly at the time of the examination. To conclude the study, 35 horses were selected randomly from both groups of horses and examined with colour-flow Doppler echocardiography. The aim of the final part of the study was to check specificity and sensitivity of auscultation for detection of AV valve murmurs and therefore validate the auscultation findings. Prior to training, the prevalence in 2-year-old racehorses of murmurs of mitral regurgitation and tricuspid regurgitation was 7.3% (4/55) and 12.7% (7/55), respectively. After training, the prevalence proportions increased to 21.8% (12/55) and 25.5% (14/55). After training, one horse developed a murmur characteristic of aortic regurgitation. The differences in murmur prevalence were statistically significant for mitral and tricuspid regurgitation (paired t test results: mitral regurgitation, P = 0.019; tricuspid regurgitation, P = 0.007), as were the differences in mean murmur grade (P = 0.018 and P = 0.0006, respectively). There were no significant effects of age on the prevalence of valvular regurgitation in 56 horses examined at race fitness. Auscultation was a specific (specificity 100%) and reasonably sensitive method for detection of murmurs of mitral and tricuspid regurgitation (mitral regurgitation: positive predictive value 100%, negative predictive value 84%, tricuspid regurgitation: positive predictive value 100%, negative predictive value 65%). These data suggest that the prevalence and grade of murmurs of mitral and tricuspid valvular regurgitation increase in 2-year-old Thoroughbreds after 9 months of athletic training. Whereas the effects of age and growth on the prevalence of murmurs cannot be ruled out from these data, this study suggests that there is an influence of athletic training on the development of atrioventricular valvular regurgitation in flat-racing Thoroughbreds.

Age Factors↗

Repeatability of Doppler ultrasound measurements of hindlimb blood flow in halothane anaesthetised horses.

The purpose of this study was to determine the repeatability of femoral blood flow recorded using Doppler ultrasound in anaesthetised horses. Doppler ultrasound of the femoral artery and vein was performed in 6 horses anaesthetised with halothane and positioned in left lateral recumbency. Velocity spectra, recorded using low pulse repetition frequency, were used to calculate time-averaged mean velocity (TAV), velocity of component a (TaVa), velocity of component b (TaVb), volumetric flow, early diastolic deceleration slope (EDDS) and pulsatility index (PI). Within-patient variability was determined for sequential Doppler measurements recorded during a single standardised anaesthetic episode. Within-patient variability was also determined for Doppler and cardiovascular measurements recorded during 4 separate standardised anaesthetic episodes performed at intervals of at least one month. Within-patient variation during a single anaesthetic episode was small. Coefficients of variation (cv) were <12.5% for arterial measurements and <17% for venous measurements. Intraclass correlation coefficient was >0.75 for all measurements. No significant change was observed in measurements of cardiovascular function suggesting that within-patient variation observed during a single anaesthetic episode was due to measurement error. In contrast, within-patient variation during 4 separate anaesthetic episodes was marked (cv>17%) for most Doppler measurements obtained from arteries and veins. Variation in measurements of cardiovascular function were marked (cv>20%), suggesting that there is marked biological variation in central and peripheral observed. Further studies are warranted to determine the ability of this technique to detect differences in blood flow during administration of different anaesthetic agents.

Anesthetics, Inhalation↗

A comparison of the haemodynamic effects of isoflurane and halothane anaesthesia in horses.

The purpose of this study was to compare the haemodynamic effects of equipotent isoflurane and halothane anaesthesia. Six adult horses were investigated on two separate occasions at least 4 weeks apart. On both occasions anaesthesia was induced by ketamine 2.2 mg/kg bwt given 5 min after i.v. administration 100 microg/kg bwt romifidine. Anaesthesia was maintained either by halothane or isoflurane (end-tidal concentrations 0.9-1.0% and 1.3-1.4%, respectively). Horses were ventilated by intermittent positive pressure to maintain PaCO2 between 40-50 mmHg. Haemodynamic variables were measured using catheter-mounted strain gauge transducers in the left and right ventricle, aorta, and right atrium. Cardiac output (CO), velocity time integral (VTI), maximal aortic blood flow velocity (Vmax) and acceleration (dv/dt(max)), left ventricular pre-ejection period (PEP) and ejection time (ET) were measured from aortic blood flow velocity waveforms obtained by transoesophageal Doppler echocardiography. Flow velocity waveforms were recorded from the femoral arteries and veins using low pulse repetition frequency Doppler ultrasound. Time-averaged mean velocity (TAV), velocity of component a (TaVa), velocity of component b (TaVb) and early diastolic deceleration slope (EDDS) were measured. Pulsatility index (PI) and volumetric flow were calculated. Microvascular blood flow was measured in the left and right semimembranosus muscles by laser Doppler flowmetry. Maximal rate of rise of LV pressure (LVdp/dt(max)), CO, Vmax, dv/dt(max), ET, VTI were significantly higher at all time points during isoflurane anaesthesia compared to halothane anaesthesia. Pre-ejection period and diastolic aortic blood pressure were significantly less throughout isoflurane anaesthesia compared to halothane. Isoflurane anaesthesia was associated with significantly lower systemic vascular resistance than halothane anaesthesia. Femoral arterial and venous blood flow were significantly higher and EDDS and PI were significantly lower during isoflurane anaesthesia compared to halothane anaesthesia. In addition during both halothane and isoflurane anaesthesia, femoral arterial flow was higher and EDDS and PI lower in the left (dependent) artery compared to the right (nondependent) artery. This study supports previous work demonstrating improved left ventricular systolic function during isoflurane compared to halothane anaesthesia. This improvement was still evident after premedication with a potent-long acting alpha2-adrenoreceptor agonist, romifidine, and induction of anaesthesia with ketamine. There was also evidence of increased hindlimb blood flow during isoflurane anaesthesia. However, there were differences observed in flow between the left and right hindlimb during maintenance of anaesthesia with each agent, suggesting that there were differences in regional perfusion in anaesthetised horses caused by factors unrelated to agents administered.

Anesthetics, Inhalation↗

Variability of Doppler ultrasound measurements of hindlimb blood flow in conscious horses.

Ultrasonography of the left and right femoral artery and vein was performed in 5 conscious horses. Velocity waveforms, recorded using low pulse repetition frequency, were used to calculate time-averaged mean velocity (TAV), velocity of component a (TaVa), velocity of component b (TaVb) and volumetric flow. Waveform analysis included calculation of early diastolic deceleration slope (EDDS) and pulsatility index (PI) and subjective description of the waveform. Measurements were recorded at monthly intervals for 6 months. The repeated measurements were used to determine the within-horse variation. Horses were then anaesthetised with halothane and the same measurements recorded 60 min after induction. Differences between measurements recorded in conscious and anaesthetised horses were determined. Within-horse variability for diameters of femoral arteries and veins was small (CV<10%). Within variability for all other measurements was marked (CV>11%), with within-horse variability being the largest for femoral venous flow (CV>35%). Source of variability was measurement error and biological variation. Despite variability in conscious horses it was possible to detect changes in blood flow during anaesthesia. In the femoral arteries, volumetric flow was lower and EDDS and PI was higher in anaesthetised horses. In the femoral veins, volumetric flow was also lower in anaesthetised horses. Therefore Doppler ultrasound appears to be a useful technique for studying blood flow in conscious and anaesthetised horses.

Animals↗

Qualitative methods add quality to cardiovascular science.

Qualitative research methods are systematic approaches to knowledge development that do not involve quantification. Such methods are used widely in nursing to understand the lived experience and the socioeconomic contexts of cardiovascular health and illness. The evolution of qualitative methods through three phases - traditional, modern and postmodern - frames the discussion. Three common qualitative methods - ethnography, phenomenology and grounded theory - are presented. Applications of qualitative methods have contributed to an understanding of such phenoma as adjustment after myocardial infarction, the experience of an acute cardiac event, the experience of chronic heart disease, the family and the cardiac illness experience, family adjustment to heart transplantation, physical activity practices of working women and family influence on individual health-related decisions in response to heart health intiatives. Postmodern approaches are briefly discussed. Participatory research is presented as an example of a postmodern approach to knowledge development. It is posited that interdisciplinary and multimethod cardiovascular research programs that incorporate qualitative methods will strengthen knowledge development in the cardiovascular field by contributing to an understanding of complex issues related to cardiovascular health and illness for individual persons, families, communities and populations, and to program and policy development.

Cardiology↗

Effects of inhaled nitric oxide 10 ppm in spontaneously breathing horses anaesthetized with halothane.

Inhaled nitric oxide, a selective pulmonary vasodilator, is known to improve arterial oxygenation after cardiopulmonary bypass and during acute respiratory distress syndrome in humans. During general anaesthesia with spontaneous ventilation, healthy adult horses develop large alveolar-arterial oxygen tension differences. In this study, we have determined the effects of inhaled nitric oxide (10 parts per million (ppm)) on venous admixture and pulmonary haemodynamics in horses anaesthetized with halothane. Seven adult horses were studied twice in random sequence. After premedication with romifidine 100 micrograms kg-1, anaesthesia was induced with ketamine 2.2 mg kg-1 and maintained with 1.1 MAC (0.95%) of halothane in oxygen. Horses breathed spontaneously. After 65 min, each horse had nitric oxide 10 ppm added to the inspired gas for 20 min (procedure HA + NO) or anaesthesia was continued with halothane in oxygen (procedure HA). Cardiac output, minute ventilation, arterial and mixed venous oxygen and carbon dioxide tensions, and mean pulmonary and carotid arterial pressures were measured for 100 min. Shunt fraction and pulmonary and systemic vascular resistances were calculated. Shunt fraction (SF) and mean pulmonary artery pressure (PPA mean) were not different between the two groups after 65 min of general anaesthesia (HA: SF 0.20 (SD 0.06), PPA mean 45 (8) mm Hg; HA + NO: SF 0.21 (0.04), PPA mean 44 (7) mm Hg) or after 85 min (HA: SF 0.22 (0.07), PPA mean 45 (8) mm Hg; HA + NO: SF 0.20 (0.03), PPA mean 43 (7) mm Hg). There were no significant effects of time or nitric oxide inhalation on any other variable. There was a significant correlation (r = 0.80, P < 0.05) between calculated shunt fraction 65 min after induction of anaesthesia and body weight.

Administration, Inhalation↗

Cardiac responses to training in 2-year-old thoroughbreds: an echocardiographic study.

Guided M-mode echocardiography was performed in seven 2-year-old Thoroughbreds before commencement of commercial flat-race training, and 18 weeks later, when all horses were either racing regularly (5 horses), or at racing fitness (2 horses). M-mode echocardiography was performed using a 2.5 MHz annular phased array ultrasound transducer and a Vingmed 800 Supervision echocardiograph. Images were obtained from the right hemithorax; a short axis view of the left ventricle (LV) at the level of the chordae tendinae was used to position the M-mode cursor. The following variables were measured: left ventricular (LV) internal diameter in diastole (LVIDd) and systole (LVIDs) and interventricular septal (IVS) and left ventricular free wall thickness (LVFW) in systole and diastole. The following variables were also calculated: LV fractional shortening (%FS), LV ejection fraction (EF), LV relative and mean wall thickness and muscle mass. Values before and after training were compared using a paired Student's t test. Training resulted in significant reductions in %FS and EF. Left ventricular internal diameter increased from 11.38 s.d = 0.58) cm before training to 12.16 (s.d. = 0.7) cm after training (P < 0.001). Calculated left ventricular mass also increased significantly (mean increase of 33% P < 0.001). Bodyweight was unchanged in the present study. Relative wall thickness was significantly increased in all horses, suggesting that eccentric cardiac hypertrophy occurs in response to commercial flat-race training. The mean post training value for relative wall thickness of 0.45 (s.d. = 0.05) for the horses in the present study is similar to that of human athletes in power/endurance disciplines.

Animals↗

Aberrant fetal growth and development after in vitro culture of sheep zygotes.

The effects of in vitro culture systems for sheep zygotes on subsequent fetal growth and development to day 61 and day 125 of gestation were studied. Zygotes recovered from superovulated Scottish Blackface ewes approximately 36 h after intrauterine insemination using semen from a single Suffolk sire were cultured for 5 days in (a) a granulosa cell co-culture system (co-culture); (b) synthetic oviductal fluid medium without serum (SOF-); and (c) synthetic oviductal fluid medium supplemented with human serum (SOF+). Control embryos were recovered from superovulated donor ewes at day 6 after oestrus. Embryos were transferred at day 6 to synchronous Scottish Blackface recipient ewes. In total, 146 gravid uteri were recovered, comprising 97 at day 61 (20 co-culture, 27 SOF-, 25 SOF+ and 25 control) and 49 at day 125 (13 co-culture, 8 SOF-, 6 SOF+ and 22 control) of gestation. Fetuses derived from co-cultured embryos were 14% heavier (P < 0.01) by day 61 of gestation than those derived from control embryos. Growth coefficients derived from the linear allometric equation logey = logea + b logex (where y = organ mass; x = fetal mass) were significantly greater (P < 0.05) for liver, heart, kidneys and plantaris muscle in fetuses derived from co-cultured embryos, and for liver in fetuses derived from SOF+ embryos than those for control fetuses. Fetuses derived from co-cultured embryos were 34% heavier (P < 0.001) and fetuses derived from SOF+ embryos were 18% heavier (P < 0.01) by day 125 of gestation than those derived from control embryos. Growth coefficients for liver and heart for fetuses derived from co-culture and SOF+ embryos were also significantly greater (P < 0.05) at this stage of gestation than those for control group fetuses. In contrast, allometric coefficients for these organs in fetuses derived from embryos cultured in SOF without serum supplementation were not different from those for controls. Excessive volumes of amniotic fluid (polyhydramnios) were observed in 23% of conceptuses derived from co-cultured embryos. In vitro embryo culture can significantly influence fetal growth and this study provides quantitative evidence of major shifts in the patterns of organ and tissue development.

Animals↗

Fetal growth and development following temporary exposure of day 3 ovine embryos to an advanced uterine environment.

The effect of exposing Day 3 ovine embryos to an advanced uterine environment for a period of 3 days on subsequent fetal growth and development between Day 35 and Day 135 of gestation was studied. Day 3 embryos were recovered from superovulated donor ewes and transferred to synchronous final or asynchronous temporary recipients for 3 days. Embryos were recovered from these temporary recipients and transferred to Day 6 final recipients. Gravid uteri were recovered, weighed and dissected on Days 35, 45, 60, 90, 110, 125 and 135 of gestation. Fetal weight and length data were analysed by fitting non-linear Gompertz models of the form log(e) y = a - be(-ct), where y is fetal size and t is time from conception. Various terms including treatment, gestational age, embryo stage at transfer and fetal sex were fitted to this model. Fetal development was assessed by relating organ weight to fetal bodyweight using the linear allometric equation log(e) y = log(e) a + b log(e) x, where y is organ weight and x is fetal weight. Temporary exposure of Day 3 embryos to an advanced uterine environment did not increase the rate of embryo development and had no effect on fetal growth and development between Days 35 and 135 of gestation in this study. A single Gompertz model (log(e) y = 10.134 - 17.047e(-0.1733t)) explained 99.8% of the variation in fetal weight. Of terms fitted to this model only gestational age and fetal sex influenced fetal weight, with male fetuses being 5% heavier (P<0.05) than female fetuses. Fetal development was also unaffected by experimental treatment in this study. Allometric coefficients established for various fetal components agreed well with those from previously published studies.

Animals↗

Haemodynamic effects of a sixty minute infusion of dopamine hydrochloride in horses anaesthetised with halothane.

To describe the haemodynamic effects of a 60 min infusion of dopamine 4 microg/kg bwt/min during halothane anaesthesia, 7 mature Thoroughbred horses were studied. The infusion began 1 h after induction of anaesthesia by romifidine (100 microg/kg) and ketamine (2.2 mg/kg bwt). Throughout the period of dopamine infusion and for 30 min after its discontinuation, the horses were ventilated by intermittent positive pressure to maintain PaCO2 between 4.6-5.4 KPa. Inspired halothane concentration was adjusted to maintain an end tidal halothane concentration of 0.9%. Haemodynamic variables were measured using intracardiac strain gauge transducers sited in the left and right ventricle, aorta, and pulmonary artery. Left ventricular pressure was differentiated to obtain maximal rate of increase of intraventricular pressure (LVdp/dtmax). Transoesophageal Doppler echocardiography was performed to measure maximum aortic blood flow velocity (vmax) and acceleration (dv/dtmax), left ventricular velocity time integral (vTI) and cardiac output (CO), and left ventricular pre-ejection period (PEP) and ejection time (ET). Measurements were made during the 60 min infusion, and for 30 min after the infusion was discontinued. Infusion of dopamine 4 microg/kg/min significantly decreased mean aortic pressure, while left and right ventricular end-diastolic pressure and mean pulmonary artery pressure remained unchanged. There was a small, but significant, increase in heart rate during dopamine infusion. Maximum acceleration of aortic blood flow, CO and vTI were also significantly increased by dopamine infusion. Maximal rate of increase of intraventricular pressure (LVdp/dtmax) was significantly decreased 10 min after commencing infusion, but then returned to baseline for the remainder of the study. Left ventricular pre-ejection period (PEP) decreased during dopamine infusion whilst ejection time (ET) significantly increased. All measured variables except LVET had returned to baseline values within 30 min of discontinuing the infusion. This study demonstrated beneficial effects of dopamine infusion upon left ventricular systolic function. However, the therapeutic value of the drug is likely to be limited in clinical anaesthesia due to the simultaneous falls in arterial blood pressure which accompany its administration.

Anesthesia, Inhalation↗

Measurement of cardiac function by transthoracic echocardiography: day to day variability and repeatability in normal Thoroughbred horses.

In order to assess the reliability and repeatability of transthoracic echocardiography for detecting serial changes in cardiac function in horses, day to day variability of a number of echocardiographic indices of ventricular function were studied. The variables investigated were, from 2-dimensional (2-D) and M-mode echocardiography - aortic diameter in systole (Aos), pulmonary artery diameter in systole (Pas), left ventricular internal diameter in systole (LLVIDs) and diastole (LLVIDd), and left ventricular fractional shortening (%FS) and estimated ejection fraction (EF). From pulsed Doppler echocardiography - maximum velocity (Vmax) and acceleration (dv/dtmax) of aortic and pulmonary arterial blood flow, left and right ventricular velocity time integral (AoVTI and PAVTI) and estimated cardiac output (COLV, and CORV), left and right ventricular ejection time (LVET and RVET) and pre-ejection period (LVPEP and RVPEP), and heart rate. Maximum velocity of early rapid right ventricular filling (ETV) and late right ventricular filling due to right atrial contraction (ATV) were measured. Maximum deceleration and time for deceleration of early rapid filling (dv/dtTV and dt TV) were also determined. Seven healthy mature Thoroughbred horses weighing 490-600 kg were studied. The horses' management regimes and environment were standardised and an echocardiographic examination was carried out on each horse at the same time every day for 6 consecutive days. Two statistical measures of repeatability were calculated for each variable: the intraclass correlation coefficient (rI) and the 95% confidence intervals for error free value of a single measurement. In general, the dimensions and indices of cardiac function derived from 2-D and M-mode echocardiography showed better repeatability for individual horses than did the indices derived from Doppler echocardiography. Overall the 95% confidence intervals for an error-free value of all variables derived from Doppler echocardiography were wide. This must be appreciated when attributing serial measured changes of Doppler echocardiographic variables in an individual animal to effects of a treatment or disease.

Analysis of Variance↗

Large offspring syndrome in cattle and sheep.

Bovine and ovine embryos exposed to a variety of unusual environments prior to the blastocyst stage have resulted in the development of unusually large offspring which can also exhibit a number of organ defects. In these animals, the increased incidence of difficult parturition and of fetal and neonatal losses has limited the large-scale use of in vitro embryo production technologies commonly used in humans and other species. Four different situations have been identified that result in the syndrome: in vitro embryo culture, asynchronous embryo transfer into an advanced uterine environment, nuclear transfer and maternal exposure to excessively high urea diets. However, programming of the syndrome by all of these situations is unpredictable and not all of the symptoms described have been observed universally. Neither the environmental factors inducing the large offspring syndrome nor the mechanisms of perturbation occurring in the early embryo and manifesting themselves in the fetus have been identified.

Animals↗

Temporal effects of an infusion of dobutamine hydrochloride in horses anesthetized with halothane.

OBJECTIVE: To evaluate temporal hemodynamic effects of dobutamine in horses anesthetized with halothane. ANIMALS: 8 adult Thoroughbreds. PROCEDURE: Anesthesia was induced by i.v. administration of romifidine and ketamine and maintained using halothane in oxygen. After 60 minutes, dobutamine was administered i.v. for 60 minutes at 4 micrograms/kg of body weight/min. Measurements of left ventricular function were obtained by transesophageal echocardiography and cardiac catheterization. RESULTS: Mean, systolic, diastolic, aortic, pulmonary arterial, and left and right ventricular end-diastolic and systolic pressures, maximal rate of increase of intraventricular pressure (LVdp/dtmax), maximum acceleration (dv/dtmax) and velocity (Vmax) of aortic blood flow, cardiac output, and left ventricular velocity time integral were significantly increased, whereas left ventricular pre-ejection period and ejection time significantly decreased. Cardiac output, LVdp/dtmax, Vmax, and dv/dtmax increased throughout infusion. Heart rate was significantly less after 10 minutes and significantly greater at 60 minutes than before infusion. Supraventricular tachycardia developed in 2 horses. Cardiac output, LVdp/dtmax, Vmax, dv/dtmax, left ventricular and aortic systolic pressures, and mean aortic pressure had not returned to control values 30 minutes after infusion was discontinued. CONCLUSIONS: At this dosage, dobutamine did not achieve peak effect on many hemodynamic variables within 40 minutes of commencing infusion, and effects of 60-minute infusion persisted after infusion was discontinued. CLINICAL RELEVANCE: Dobutamine has a hemodynamic profile suited to treatment of low cardiac output in anesthetized horses; however, sustained administration may be associated with supraventricular tachycardia and a protracted time to peak effect.

Anesthesia, Inhalation↗

Measurement of cardiac output in standing horses by Doppler echocardiography and thermodilution.

Measurement of cardiac output by Doppler echocardiography were compared to simultaneous measurements by thermodilution in 9 conscious horses. In the Doppler technique, mean blood flow velocities for estimation of cardiac output were recorded from the aorta and pulmonary artery. The flow area of each vessel was calculated from the vessel diameter, measured from a 2-dimensional ultrasound image. Differences in the site and method of measuring the vessel diameter altered the estimation of cardiac output by the Doppler method. Cardiac output was modified by the i.v. infusion of 4 micrograms/kg bwt/min dopamine and 4 micrograms/kg bwt/min dobutamine and by the i.v. administration of 10 micrograms/kg bwt detomidine and 20 micrograms/kg bwt butorphanol. Doppler measurements of cardiac output correlated closely with measurement by thermodilution. Measurements from the aortic outflow correlated more closely with thermodilution, than those from the pulmonary artery (r = 0.89 and r = 0.77, respectively). Doppler measurements when the mean flow velocity was recorded from the aorta and the flow area was measured from the ascending aorta using the leading edge method. There was no significant bias between the 2 techniques when Doppler flow velocities were recorded by this method and the limits of agreement were narrow (+/- 12.26 l/min). The differences between the 2 methods increased with increasing cardiac output. Doppler echocardiography is a safe noninvasive method of measuring cardiac output in horses. The agreement between Doppler echocardiography and thermodilution in this study is similar to that reported in man and is similar to that reported between thermodilution and other techniques in man.

Analgesics↗

Temporal effects of an infusion of dopexamine hydrochloride in horses anesthetized with halothane.

OBJECTIVE: To evaluate the hemodynamic effects of a 60-minute infusion of dopexamine in horses anesthetized with halothane. ANIMALS: 7 adult Thoroughbreds. PROCEDURE: Measurements of left ventricular function obtained by transesophageal Doppler echocardiography and cardiac catheterization. RESULTS: Infusion of dopexamine (4 micrograms/kg of body weight/min) significantly increased heart rate, cardiac output, maximal rates of increase and decrease of left ventricular pressure, and maximal acceleration and maximal velocity of aortic blood flow. Left ventricular ejection time significantly increased, and pre-ejection period decreased during the infusion. Cardiac output, maximal rate of increase of left ventricular pressure, and maximal acceleration continued to increase as the infusion progressed. Right ventricular end-diastolic pressure was significantly decreased after 20 minutes of infusion and decreased progressively throughout the remaining time of infusion. Many hemodynamic variables, including right ventricular end-diastolic pressure, had not returned to control values 30 minutes after the infusion was discontinued. A number of undesirable adverse effects were observed in horses receiving dopexamine infusion; during administration, profuse sweating occurred in every horse. In 6 horses, recovery from anesthesia was associated with excitement and violent shivering. Colic developed in 2 horses within 3 hours of recovery. CONCLUSIONS: Dopexamine (4 micrograms/kg/min) does not achieve a peak effect on many hemodynamic variables within a short period of commencing administration, and the effects of infusion may persist for extended periods after drug administration is discontinued. CLINICAL RELEVANCE: Dopexamine has a hemodynamic profile suited to treatment of low cardiac output in anesthetized horses; however, at the dosage rate studied (4 micrograms/kg/min), its administration was associated with a number of undesirable adverse effects which could preclude its clinical use.

Anesthetics, Inhalation↗

Measurement of cardiac output by transoesophageal Doppler echocardiography in anaesthetized horses: comparison with thermodilution.

In order to determine if transoesophageal Doppler echocardiography could be used to estimate cardiac output in anaesthetized horses, we have compared the technique with estimations of cardiac output by thermodilution in eight healthy adult thoroughbreds. Measurements of aortic blood flow velocity were made by high pulse repetition frequency (HPRF) and continuous wave (CW) Doppler echocardiography from a 3.5-MHz transoesophageal probe. Cardiac output was increased during the study by administration of dobutamine, providing a range of cardiac output measurements by thermodilution from 15.0 to 64.4 liter min-1. Estimations derived from CW Doppler overestimated cardiac output compared with thermodilution (bias = 4.0 litre min-1). Estimations from HPRF Doppler echocardiography more closely reflected measurements obtained by thermodilution (bias = 0.7 litre min-1). Limits of agreement between the techniques were similar for both modes of insonation (HPRF = -7.7 to 9.1 litre min-1, CW = -4.9 to 12.8 litre min-1). There were significant differences in bias between both Doppler techniques and thermodilution for individual horses. As a result, for any individual horse, limits of agreement between the techniques were closer (HPRF = +/- 6.4 litre min-1, CW = +/- 7.6 litre min-1). We conclude that transoesophageal echocardiography provided an alternative, effective and non-invasive method for measurement of cardiac output in anaesthetized horses.

Anesthesia, General↗