Search PubMed⌕ Search

Biomedical subjects

L E Olsson

Publications and source records attributed to L E Olsson.

33 records · Page 2Linked to original sources

Ferrous sulphate gel dosimetry and MRI for proton beam dose measurements.

Ferrous sulphate gel dosimetry has the potential for measurement of absorbed dose distributions in proton therapy. The chemical properties of the gel are altered according to the radiation dose and these changes can be evaluated in three dimensions using MRI. The purpose of this work was to investigate the properties of a ferrous gel used with clinical proton beams. The gel was irradiated with both monoenergetic and range-modulated proton beams. It was then evaluated using MRI. The depth dose by means of the 1/T1 distribution was studied and compared with data from a plane-parallel plate ionization chamber. 1/T1 was shown to be proportional to the dose at a mean proton energy of approximately 90 MeV. The dose response was no different from that obtained using photon beams. However, on normalization at the entrance, the relative 1/T1 at the Bragg peak was 15-20% lower than the corresponding ionization chamber data for the monoenergetic proton beam. Better agreement was found for the modulated beam, but with significant differences close to the distal edge of the 1/T1 distribution. The change in sensitivity with depth was explained by means of a linear energy transfer dependence. This property was further studied using Monte Carlo methods.

Calibration↗

Pleurotomy, pneumothorax, and surveillance during living donor nephroureterectomy.

OBJECTIVES: To determine the incidence of and risk factors associated with pneumothorax after donor nephroureterectomy and to determine the utility of postoperative chest roentgenography. METHODS: A retrospective review was made of 130 living donor nephroureterectomies performed at one institution (Yale-New Haven Hospital) using an extraperitoneal flank incision. RESULTS: Incidental pleurotomy occurred in 11 cases (8.5%). Rib resection was associated with pleurotomy. Patient age, sex, and side of operation were not associated with pleurotomy. Ten (91 %) of the 11 cases were identified intraoperatively. One unrecognized pneumothorax was identified postoperatively with chest roentgenography; no specific intervention was necessary. CONCLUSIONS: The extraperitoneal flank incision poses a significant risk for pneumothorax. Most pneumothoraces will be recognized intraoperatively. No adverse effects were noted secondary to pneumothorax.

Adolescent↗

Verification of single beam treatment planning using a ferrous dosimeter gel and MRI (FeMRI).

A method for analysing and comparing treatment planning system (TPS) data and ferrous dosimeter gel measurements evaluated with MRI (FeMRI) was developed, including image processing to final absorbed dose images. Measurements were analysed according to this method and FeMRI data were thereby compared with the TPS-calculated dose distribution. For photons, differences between FeMRI- and TPS dose data were mainly within +/- 2%. Minor shortcomings found in both the FeMRI system and the TPS are explained and discussed. For electron beams, there was an overall good agreement. It was found that the TPS underestimates the lateral scattering dose outside the primary beam, but the reported dose difference corresponds to a small spatial deviation (less than 2 mm). It is important to consider this single beam data comparison when the method is extended to more complicated situations, for example when using several beams.

Ferrous Compounds↗

Improvements in absorbed dose measurements for external radiation therapy using ferrous dosimeter gel and MR imaging (FeMRI).

A ferrous gel, based on ferrous (Fe) sulphate and agarose, was used with a clinical magnetic resonance imaging (MRI) scanner to obtain relative dose distribution data from therapeutic photon and electron beams. The FeMRI gel was scanned using a new MRI acquisition protocol optimized for T1 measurements. Thorough comparisons with silicon semiconductor detector and ionization chamber measurements, as well as with Monte Carlo calculations, were performed in order to quantify the improvements obtained using FeMRI for dose estimations. Most of the relative doses measured with FeMRI were within 2% of the doses measured with other methods. The larger discrepancies (2-4%) found at shallow depths are discussed. The uncertainty in relative dose measurements using FeMRI was significantly improved compared with previously reported results (5-10%, one standard deviation, 1 SD), and is today between 1.6% and 3.3% (depending on dose level, 2 SD). This corresponds to an improvement in the minimum detectable dose (3 SD above background) from approximately 2 Gy to better than 0.6 Gy. The results obtained in this study emphasize the importance of obtaining basic FeMRI dose data before the method is extended to complicated treatment regimes.

Electrons↗

Bladder instillation and intraperitoneal injection of Escherichia coli lipopolysaccharide up-regulate cytokines and iNOS in rat urinary bladder.

Systemic bacterial lipopolysaccharides (LPS) induce inflammatory responses characteristic of sepsis. Instillation of LPS into rat bladder produces a localized inflammatory response similar to that seen in urinary tract infections (UTIs). Four hours after intravesical instillation of LPS, neutrophils infiltrate into the bladder, and mRNA for inducible nitric oxide synthase (iNOS) and the cytokines, interleukin (IL)-6 and IL-10, is detected in rat bladder but not in the kidney. Induction of iNOS protein is inferred because urinary nitrate and cGMP levels are increased 4 hr after LPS intravesical instillation and remain elevated for at least 24 hr. When LPS is injected intraperitoneally, iNOS and IL-6 mRNA are induced both in the bladder and in the kidney. These data are consistent with the effects of intravesical instillation of LPS remaining localized, iNOS activity increases in both particulate and soluble bladder fractions when measured 4 hr after intravesical instillation of LPS. The magnitude of these increases in iNOS activity in the bladder is not as great as when LPS is injected intraperitoneally. Intravesical instillation of LPS induces no increase in lung or kidney NOS activity. The localized inflammatory response produced by intravesical instillation of LPS demonstrates the importance of LPS as a mediator of the host response in UTIs and supports the use of urinary measurements of nitrate and cGMP in humans as indicative of the localized induction of iNOS in UTIs.

Animals↗

Dosimeter gel and MR imaging for verification of calculated dose distributions in clinical radiation therapy.

A dosimeter gel, based on an agarose gel infused with a ferrous sulphate solution and evaluated in a magnetic resonance scanner, was used for complete verification of calculated dose distributions. Two standard treatment procedures, treatment of cancer in the urinary bladder and treatment of breast cancer after modified radical mastectomy, were examined using pixel-by-pixel and dose volume histogram comparison. The dose distributions calculated with the dose planning system was in very good agreement with the measured ones. However, in the case of the more complicated breast cancer treatment, some discrepancies were found, mainly at the beam abutment region. This may be explained by field displacements errors and by a small limitation of the dose planning utilising small electron beams in this region. The dosimeter gel system have proven to be a useful tool for dosimetry in clinical radiation therapy applications.

Breast Neoplasms↗

Three-dimensional dose mapping from gamma knife treatment using a dosimeter gel and MR-imaging.

A new method has been investigated for the mapping of dose distributions in three dimensions delivered by the Leksell gamma knife. The irradiation unit is used to selectively treat small volumes in the brain with single high doses of ionising radiation--a treatment procedure known as radiosurgery. The dosimetry method investigated utilises a dosimeter gel consisting of ferrous sulphate solution and agarose which is, prior to irradiation, loaded into a cavity in a spherical phantom. Chemical changes induced in the gel by the radiation are measured by means of an MR-scanner. This imaging method permits rapid evaluation of the dose distribution in an irradiated volume. It thus offers a potential verification of individual radiation intracranial target treatment regimes as well as quality assurance measurements, assuming that the precision and accuracy of the dose mapping are adequate. The dose and its distribution registered by the gel dosimeter, in this initial experiment, are in good agreement with corresponding computed data obtained with the KULA treatment planning system of the gamma knife. The gel has thus the potential of being an attractive alternative dose mapping method to those used at present in radiosurgery, i.e. radiographic film and small ionisation chambers. The precision of the dosimeter gel is, however, not yet sufficient high to be used as a basic dosimetry system for the gamma knife.

Gels↗

Nickel-doped agarose gel phantoms in MR imaging.

A method for the production of a tissue-mimicking phantom material for MR imaging is described. The material consists of a nickel-doped agarose gel. The T1 and T2 values of the gel can be varied independently by changing the relative amounts of nickel and agarose. Practically any T1 and T2 combination of clinical interest can be obtained. The long-term stability was studied and found to be good. The relaxation times were estimated using an MR analyzer. The accuracy and the reproducibility of these measurements were evaluated and found to be reassuring. Gel phantoms were also scanned in an MR unit. The signal strength of an inversion recovery sequence was evaluated using the gel phantoms in order to verify their usefulness. These measurements were compared to theory with good agreement. Furthermore, tissue-equivalent phantoms were made. Gels resembling gray matter, white matter, and CSF were scanned. Comparisons with clinical in vivo scans, as well as calculated levels were made. It is anticipated that the gel phantoms described here will be useful in quality assurance as well as in pulse sequence optimization.

Gels↗

MR imaging of absorbed dose distributions for radiotherapy using ferrous sulphate gels.

The measurement of absorbed dose distributions using dosemeter gel and magnetic resonance imaging (MRI) in a standard geometry has been investigated. Absorbed depth-dose curves and profiles measured with this new technique show good agreement with corresponding measurements using diodes. This was proven in a 60Co beam as well as an electron beam. The dosemeter gel is made of agarose and ferrous sulphate solution. The dose response is linear (r = 0.9996) in the investigated dose interval, 0-40 Gy. The sensitivity is a factor of about six higher compared to ordinary ferrous sulphate solution, known as 'Fricke'. This is a true 3D dose measurement technique which will have a number of applications in radiation therapy, since it is possible to mould the gel to arbitrary geometries, mix different radiation qualities and integrate the absorbed dose from different kinds of fields.

Dose-Response Relationship, Radiation↗

Preoperative localization in unilateral parathyroid surgery. A cost-benefit study on ultrasound, computed tomography and scintigraphy.

In 50 patients with primary hyperparathyroidism, investigation before initial neck exploration included ultrasonography, computed tomography and 99technetium-201thallium subtraction scintigraphy. The sensitivity for correct preoperative localization was 50%, 54% and 56%, respectively. There was marked inter-observer variation in assessment of ultrasonography and computed tomography, while scintigrams were evaluated by only one person. The scintigraphic sensitivity increased with size of the glands. In cases where correct preoperative localization permitted unilateral parathyroidectomy, the time for surgery and anesthesia was significantly reduced. A cost-benefit analysis, however, revealed that the financial saving from this time reduction was outweighed by the cost of the localization procedures. The authors conclude that investigations for definition of enlarged parathyroid glands are not indicated prior to unilateral parathyroidectomy.

Adult↗

Tomographic scintigraphy using a pinhole collimator and a rotating gamma camera.

When a pinhole collimator is to be used for tomographic studies the standard SPECT software has to be modified so as to avoid serious image distortion outside the axis of rotation. The MTF measured at the axis of rotation shows that the better resolution of the pinhole collimator as compared with that of a parallel-hole collimator improves the tomographic image. The low sensitivity of the pinhole collimator excludes the use of an aperture smaller than 6 mm for patient tomographic studies where the activity which may be administered is restricted.

Adenoma↗

Ferrous sulphate gels for determination of absorbed dose distributions using MRI technique: basic studies.

Two gels have been found to be suitable to load with ferrous sulphate solution. In these soft tissue equivalent phantoms, the absorbed dose distribution can be measured after irradiation in clinically used MR imaging equipment. The present studies were carried out using a 0.25 T NMR analyser without imaging properties. A ferrous sulphate solution, 0.05 M with respect to sulphuric acid, can be gelled with 4% gelatin to give a dosemeter which has a response which is linearly correlated (r = 0.998) with the absorbed dose in the interval 0-40 Gy. Ferrous sulphate solution can also be gelled with 1% agarose, but this gel has to be purged with oxygen to obtain a linear relationship (r = 0.997) in the same absorbed dose interval. The ferrous sulphate loaded gels have a sensitivity which is a factor of 2.2 or 4.0 times higher for gelatin and agarose, respectively, than the ordinary dosemeter solution. Because the standard deviation of background measurements is higher for the gels than for the dosemeter solution, the minimum detectable absorbed dose is about the same, or 1.0 Gy, for the two gels and the dosemeter solution. The sensitivity of the ferrous sulphate loaded gels shows no dependence on dose rate if the mean dose rate and the absorbed dose per pulse are within the limits normally used by accelerators for radiotherapy.

Ferrous Compounds↗