Search PubMed⌕ Search

Biomedical subjects

L E Crooks

Publications and source records attributed to L E Crooks.

At least 37 records · Page 2Linked to original sources

Magnetic resonance imaging the velocity vector components of fluid flow.

Encoding the precession phase angle of proton nuclei for Fourier analysis has produced accurate measurement of fluid velocity vector components by MRI. A pair of identical gradient pulses separated in time by exactly 1/2 TE, are used to linearly encode the phase of flow velocity vector components without changing the phase of stationary nuclei. Two-dimensional Fourier transformation of signals gave velocity density images of laminar flow in angled tubes which were in agreement with the laws of vector addition. These velocity profile images provide a quantitative method for the investigation of fluid dynamics and hemodynamics.

Fourier Analysis↗

Assessment of cardiac anatomy using nuclear magnetic resonance imaging.

Nuclear magnetic resonance imaging has emerged in the past few years as a completely noninvasive method for medical imaging of internal organs. Because of the loss of signal intensity by motional nuclei (hydrogen) using most proton imaging techniques, flowing blood within the cardiovascular system generates little or no signal and consequently there is high natural contrast between blood and the walls of blood vessels or cardiac chambers. However, motion during imaging also complicates cardiac imaging because signal is lost from the nuclei in the moving cardiac structures. Consequently electrocardiographic gating of data acquisition is required for nuclear magnetic resonance imaging of the heart. Distinct advantages of nuclear magnetic resonance imaging in relation to other imaging modalities are good contrast between soft tissues and the capability for characterization of specific tissues by estimation of magnetic relaxation times. Early in vitro studies measuring relaxation times of myocardial tissue samples of excised hearts indicate that nuclear magnetic resonance imaging will be capable of discriminating infarcted from normal myocardium. Recent studies using electrocardiographically gated nuclear magnetic resonance imaging of dogs with acute infarction showed the infarct as a region of high intensity on spin-echo images. Initial clinical experience with electrocardiographically gated nuclear magnetic resonance imaging (0.35 tesla) in patients has clearly defined internal cardiac anatomy without the use of contrast media. This technique has demonstrated the consequence of previous myocardial infarction such as regional wall thinning, aneurysm, thrombus and contractile dysfunction, a number of pericardial abnormalities and the morphology of hypertrophic and congestive cardiomyopathies.

Coronary Circulation↗

A comparison of saddle-shaped and solenoidal coils for magnetic resonance imaging.

Differences in magnetic resonance (MR) imaging signal-to-noise (S/N) performance between saddle-shaped and solenoidal coils have been postulated. Each coil shape is tied to a particular magnetic field configuration, so that they are not typically interchangeable except in special situations. The solenoidal coil is predicted to have a two- to three-fold advantage over the saddle-shaped coil. Simple basic arguments raise a dispute with this assertion. Experiments show that both coils produce essentially equivalent S/N levels.

Animals↗

Bone marrow imaging: magnetic resonance studies related to age and sex.

Measurements of T1 and T2 relaxation values and spin density of the lumbar vertebral bone marrow were performed in 212 patients, and the results were correlated with the patients' age and sex. T1 and T2 relaxation times for bone marrow in the lumbar vertebral bodies showed a progressive decrease with age for both sexes (except for the T2 relaxation values in female patients). The replacement of hematopoietic marrow by fatty marrow could explain the decrease in T1 and T2. The T1 and T2 values were in the same range for the first two age groups (age 1-10 years and age 21-40 years) and became slightly greater for the older female patients (age 51 years and older) than for the older males. This could be due to the loss of bone and mineral content, which is more rapid and significant for women. These normal T1 and T2 values may provide a baseline for future evaluation of diseases involving the lumbar spine.

Adolescent↗

Multiple spin-echo magnetic resonance imaging.

Spin-echo magnetic resonance (MR) imaging detects a variety of pathologic states with great sensitivity. A technique for producing multiple spin-echo images in multisection operation is presented. This method of intensity-image acquisition is compared with retrospective intensity-image synthesis from routine data sets. Both yield long echo time (TE) images with similar image contrast and comparable and often increased diagnostic utility. Technical and clinical considerations are addressed, including signal-to-noise levels, flow effects, and patient throughput.

Brain Diseases↗

Magnetic resonance imaging of the heart: a review of the experience in 172 subjects.

Gated magnetic resonance (MR) imaging was used to evaluate central cardiovascular anatomy in 172 subjects, 31 of whom were healthy volunteers. Using the spin-echo technique, images of diagnostic quality were obtained in 93% of cases with TE = 28 msec and in 65% of cases with TE = 56 msec. Transverse multisection sequences encompassing most of the left ventricle required approximately 6-8 minutes. Corroborative studies were available in 134 of 141 patients who had cardiovascular disease; two dimensional echocardiograms and angiography in 133 and 100 patients, respectively. Gated MR demonstrated the wall thinning and complications caused by prior myocardial infarctions and high signal intensity of the myocardium at the site of acute myocardial infarctions. MR accurately demonstrated anatomic abnormalities owing to hypertrophic and congestive cardiomyopathies, congenital abnormalities of the heart and great vessels, rheumatic heart disease, pulmonary hypertension, and cardiac and paracardiac masses. Depiction of cardiovascular anatomy and pathoanatomy was attained without the use of any contrast media. Consequently, gated MR is an effective technique for cardiac diagnosis. The short time required for tomographic examination of the entire heart using the multisection technique renders this a practical cardiac imaging modality.

Adolescent↗

Variable magnetic resonance imaging parameters: effect on detection and characterization of lesions.

With change in the imaging technique and magnetic field strength used in magnetic resonance imaging, wide variations in the delineation of pathologic features occur. Using imaging data from patients with known pathologic conditions, we evaluated the intensity images in spin-echo and inversion-recovery imaging at varying repetition times, echo times, and inversion times over broad ranges and changing magnetic field strengths. Differences in conspicuity and the apparent size of the lesions are important to consider in diagnosing and evaluating pathologic conditions, especially when different imagers and techniques are employed.

Brain Diseases↗

Gated MR imaging of the heart: intracardiac signals in patients and healthy subjects.

The appearance of intraluminal signal in the cardiac chambers, the descending aorta, and blood vessels was studied in healthy subjects and patients with myocardial disease on first and second spin-echo gated magnetic resonance images. Signal was present in the cardiac chambers and the aorta at various phases of the cardiac cycle when physiological or pathological slow flow conditions are expected in healthy subjects and in patients. Healthy individuals tended to show signal in the ventricles and aorta during end-diastole, and signal was less likely to be present at higher heart rates and in systolic images. In patients with regional or global left ventricular dysfunction, intraventricular signal tended to persist into systole. Surprisingly, intraventricular signal was not present with increased frequency adjacent to infarcted regions of the myocardial wall. Thus, the mere presence of intracavitary signal cannot be used as an indicator of either regional or global cardiac contraction abnormalities. In the left atrium, signal was often present during systole. Physical factors determining the appearance of signal of flowing blood are discussed in an Appendix.

Adult↗

Inner volume MR imaging: technical concepts and their application.

Although cross-sectional magnetic resonance examination of the head and body is useful for screening large regions of tissue, subsectional regions of the head and body often need to be examined. Orthogonally directed, selectively irradiated planes with different flip angles produce a spatially limited signal region from which two- or three-dimensional volume images can be reconstructed. Images with limited fields-of-view can be acquired in reduced imaging time. We present a general description of this technique. These subsectional or "inner volume" images eliminate respiratory motion artifacts by excluding moving tissues from the imaged volume. A result of this technique is a high signal from rapid pulsatile blood flow, produced without cardiac gating the pulse sequence.

Blood Flow Velocity↗

Urinary bladder MR imaging. Part I. Normal and benign conditions.

The normal urinary bladder and several benign entities of the bladder were examined in 50 patients by magnetic resonance (MR) imaging. Specific features assessed included appearance of the bladder wall, optimal repetition (TR) and echo delay (TE) parameters for bladder-wall demonstration, and differentiation among various benign abnormalities, including bladder-wall hypertrophy, inflammation, and mucosal congestion, on MR images. The bladder wall in the 30 healthy subjects was best displayed using a TR = 2 sec, TE = 56 msec image, which gave 60% contrast between the bladder wall and urine and 48% contrast between the bladder wall and fat. Demonstration of bladder-wall hypertrophy required similar imaging; bladder distention was necessary to demonstrate the thickness of the bladder wall. Congestion and inflammation were best demonstrated on TR = 2 sec, TE = 56 msec images, which gave 45% contrast. Normal and/or hypertrophic bladder wall were distinguished from inflammation and congestion on the basis of signal intensity variations and/or T1 and T2 relaxation parameters.

Adult↗

Hydrogen MR imaging of the head at 0.35 T and 0.7 T: effects of magnetic field strength.

To determine whether hydrogen magnetic resonance imaging at 0.7 T provides added clinical value over imaging at 0.35 T, images of the heads of patients with various intracranial disorders were obtained at these field strengths. Measurements of tissue contrast (C), signal-to-noise (S/N) ratio, and T1 and T2 relaxation times were determined. For a given spin-echo sequence with equal imaging time, resolution, and data sampling window, the product C X S/N was somewhat lower for the lower field strength. Under conditions of imaging with equal chemical shift artifact, C X S/N at 0.35 T was equal to or greater than that measured at 0.7 T. With an increase in field strength, T1 of pathologic areas and surrounding normal tissues increased, resulting in a corresponding loss of absolute signal level and decrease in contrast. Lesions were equally well seen at both 0.35 T and 0.7 T. The increased T1 and decreased C X S/N for higher magnetic fields--when measured with a fixed imaging time, resolution, chemical shift, and sequence--suggest that such field strengths may not improve tissue contrast, diagnostic ability, or clinical throughput when compared with lower field strength systems.

Brain↗

MR imaging of the aorta with three-dimensional vessel reconstruction: validation by angiography.

Longitudinal vascular structures are difficult to observe on the standard abdominal transaxial magnetic resonance (MR) image sections. To display the information in a three-dimensional reconstruction, an algorithm was written to identify blood flow in a series of transaxial MR sections and was applied to reconstructing images of the aorta and iliac arteries in 12 patients with aortic aneurysm, dissection, or aortoiliac atherosclerosis. Results were validated by angiography. In all patients, the outline of the flow channel in the reconstructed image followed closely the outline of the lumen on angiograms. In aortic dissection, the MR images showed the two lumens more completely than did the angiograms, and in atherosclerosis, sites of vascular stenosis were correctly identified on MR images. The technique is valuable in providing anatomic information as well as functional information on cross-sectional areas and relative flow velocities.

Aortic Dissection↗

MR imaging of blood vessels using three-dimensional reconstruction: methodology.

Multisection, dual-echo magnetic resonance (MR) transaxial images of blood vessels contain both anatomic and qualitative information about flow. Even so, the images are produced as a series of two-dimensional tomographic sections from which full visualization of connected structures is difficult. A computer algorithm was developed that automatically detects flowing blood based on pixel intensity and calculated T2 and provides reconstructed views of vessels while analyzing and displaying flow characteristics. Images of abdominal vessels, aortic aneurysms, and the heart were encoded by flow and color to demonstrate depth. In addition, these data were reconstructed to derive a more accurate assessment of patency. With this technique, transaxial images can be used to analyze flow patterns, determine patent areas, and visualize all levels of vessels in a single image.

Blood Flow Velocity↗

Signal to noise in derived NMR images.

The NMR image is dependent on multiple tissue parameters: hydrogen density, relaxation times T1 and T2, and flow. From the acquired intensity images, T1, T2, and hydrogen images may be produced. The signal/noise of these derived images is critically dependent on the choice of acquisition parameters. Using the calculated T1, T2, and hydrogen images, intensity images may be calculated at arbitrary values of TE and TR, some of which (for example, short TE or TR) may be physically unacquirable.

Brain↗

Nuclear magnetic resonance of pulmonary arteriovenous fistula: effects of flow.

Nuclear magnetic resonance (NMR) imaging can be of value in distinguishing vascular and nonvascular lesions in the lung and mediastinum, in that rapidly flowing blood results in little or no NMR signal. We wish to report a patient having a pulmonary arteriovenous fistula evaluated using physiological studies, dynamic computed tomography, and spin-echo NMR. On the NMR images, the fistula was invisible because of rapid flow through its lumen.

Aged↗