Characterization of recovery profiles using gas chromatography-triple quadrupole mass spectrometry for the determination of pesticide residues in meat samples.

The assessment of the recovery factor with the analyte concentration in meat samples has been studied for the determination of organochlorine and organophosphorus pesticides in meat by gas chromatography-triple quadrupole mass spectrometry (GC-MS/MS). For that purpose, recent IUPAC recommendations, which distinguishes between two terms, recovery factor and apparent recovery, have been followed. Besides, the systematic error due to the matrix effect has been evaluated by a new term recently proposed, calibration recovery. Recovery profiles were obtained analyzing spiked blank matrix, where the analytes were added before and after the extraction procedure. In a first step, the quantification of the compounds was carried out using a solvent calibration curve. The systematic errors due to the matrix effect during the quantification step and the error due to the sample treatment have been evaluated. Both apparent and calibration recovery components depend on the actual analyte concentration in the sample while the recovery factor remains constant except for analyte concentration close to quantification limit. In addition, the concentration limits, from which an acceptable recovery value (70-110%) can be obtained, are given. If spiked samples are quantified by matrix-matched calibration, the matrix effect is minimized and the calibration recovery component is 100%, and apparent recovery only depends on the recovery factor. The obtained values indicate recovery factor does not depend on the analyte concentration, except for those values closed to quantification limit.

Animals↗

A comparative study of the correction of systematic errors in the quantitation of pyrethroids in vegetables using calibration curves prepared using standards in pure solvent.

A comparative study of two mathematical approaches was performed in order to correct systematic errors due to the presence of the unexpected interferences which appear when the quantitation of the analyte in real samples is carried out with calibration curves built using standards in pure solvent. These methods consisted in the establishment of different mathematical expressions which transform the concentration (Cs) obtained using calibration graphs built using pure solvent into the corrected concentration (C(M)) that should be obtained if the quantitation is carried out with calibration curves built using standards dissolved in blank matrix extracts. In the two approaches the correction is performed from the results of an intermediate precision study which was carried out using both calibration graphs (prepared using pure solvent and blank matrix extract). By using ANCOVA to compare the slope of both solvent-based and matrix-matched calibration graphs, matrix effect was found in the determination of deltamethrin in tomato and acrinathrin in tomato and pepper. In these cases, both approaches led to good results.

Calibration↗

Optimizing analytical methods using sequential response surface methodology. Application to the pararosaniline determination of formaldehyde.

Sequential response surface methodology is a general procedure to re-optimize common analytical methods on the basis of the application of the response surface methodology and of a new approach to the steepest ascent method. This procedure, which is easy to apply, consists of estimating an analytical function relating the response with the experimental parameters by means of a second-degree polynomial. Thus, a 2nd order design covering the total experimental domain is used and when a maximum is obtained, the characteristics of the response surface are confirmed using a new design, which is obtained contracting the first one. In the proposed methodology, Box-Behnken designs are used because they offer advantages in comparison with second order designs more frequently used in the steepest ascent method (central composite designs), i.e. fewer experiments are needed, they are more efficient, they can be moved through the experimental domain and they can even be easily contracted or expanded.