Cell alignment is induced by cyclic changes in cell length: studies of cells grown in cyclically stretched substrates.

Many types of cells, when grown on the surface of a cyclically stretched substrate, align away from the stretch direction. Although cell alignment has been described as an avoidance response to stretch, the specific deformation signal that causes a cell population to become aligned has not been identified. Planar surface deformation is characterized by three strains: two normal strains describe the length changes of two initially perpendicular lines and one shear strain describes the change in the angle between the two lines. The present study was designed to determine which, if any, of the three strains was the signal for cell alignment. Human fibroblasts and osteoblasts were grown in deformable, rectangular, silicone culture dishes coated with ProNectin, a biosynthetic polymer containing the RGD ligand of fibronectin. 24 h after plating the cells, the dishes were cyclically stretched at 1 Hz to peak dish stretches of 0% (control), 4%, 8%, and 12%. After 24 h of stretching, the cells were fixed, stained, and their orientations measured. The cell orientation distribution was determined by calculating the percent of cells whose orientation was within each of eighteen 5 degrees angular intervals. We found that the alignment response was primarily driven by the substrate strain which tended to lengthen the cell (axial strain). We also found that for each cell type there was an axial strain limit above which few cells were found. The axial strain limit for fibroblasts, 4.2 +/- 0.4%, (mean +/- 95% confidence), was lower than for osteoblasts, 6.4 +/- 0.6%. We suggest that the fibroblasts are more responsive to stretch because of their more highly developed actin cytoskeleton.

Adolescent↗

Mechanical stimulation by external application of cyclic tensile strains does not effectively enhance bone healing.

OBJECTIVE: To determine whether an externally induced interfragmentary movement enhances the healing process of a fracture under flexible fixation. DESIGN: Randomized, prospective in vivo animal study with control group. Twenty-four skeletally mature Merino sheep were randomly assigned to six groups of four animals, which received cyclic interfragmentary movements of 0.2 and 0.8 millimeters and stimulation frequencies of 1, 5, and 10 Hertz, respectively. Twelve animals did not receive any externally applied stimulation and served as a control group. SETTING: Unrestricted stall activity with weight bearing reduced by tenotomy of the Achilles tendon. INTERVENTIONS: Osteotomy of the tibial diaphysis with three-millimeter gap width fixed with a six-pin, monolateral, double-bar external fixator. Interfragmentary movement of the osteotomy gap was externally induced by a motor-driven actuator unit. Five hundred cycles inducing nonuniform tensile strains within the gap were performed each day. MAIN OUTCOME MEASUREMENTS: Nine weeks after surgery, the animals were killed, and bone mineral density and callus cross-sectional area were measured with quantitative computed tomography. Callus projectional area was assessed by radiographs, and mechanical stability was determined with a three-point bending test. RESULTS: External stimulation with nonuniform cyclic tensile strains did slightly affect but not significantly enhance the fracture healing process. Varying the stimulation frequency had no influence on the healing process. The stimulation with 0.8 millimeter displacement magnitude resulted in a larger periosteal callus, but a decreased bone mineral density compared with the 0.2-millimeter displacement magnitude. The stimulation had no significant influence on the mechanical properties of the healing bone. CONCLUSIONS: Induced cyclic tensile strains did not produce a relevant enhancement of bone healing under flexible fixation.

Animals↗

Radiographic results of callus distraction aided by pulsed low-intensity ultrasound.

OBJECTIVES: To determine whether pulsed low-intensity ultrasound (frequency of 1.5 megahertz, pulsed by one kilohertz, signal burst width of 200 microseconds, intensity of thirty milliwatts per square centimeter, and daily treatment time of twenty minutes per day) stimulates regenerate maturation after callus distraction. DESIGN: Prospective, controlled animal trial. METHODS: Operatively, we created a fifteen-millimeter defect in the right metatarsus of eighteen female mature merino sheep. A segmental transport was begun on Day 5 using a high-stiffness experimental ring fixator. The distraction rate was one millimeter per day divided into two increments of 0.5 millimeters each. On Day 21 after the operation, distraction was finished and the maturation period started and lasted until Day 84 after operation. During this period, Group 1 was treated with a daily twenty-minute low-intensity ultrasound stimulation (frequency of 1.5 megahertz, pulsed by one kilohertz, signal burst width of 200 microseconds, intensity of thirty milliwatts per square centimeter). Group 2 had no stimulation. Animals bore full weight. Plain radiographs in the anteroposterior view were taken every two weeks during the maturation period. After the animals were killed on Day 84, anteroposterior and lateral high resolution radiographs and computed tomography (CT) scans of the regenerate were performed. For each plain and high resolution radiograph, two different relationships (callus relation, the ratio of the amount of periosteal callus to the size of the space between the proximal fragment and transported segment; and interzone relation, the ratio of the fibrous callus interzone to the size of the new formed callus) were calculated. Using CT scan, callus area, bone density, and bone mineral content were evaluated. RESULTS: The results of interzone relation (both views) and callus relation (lateral view) in high-resolution radiographs and bone mineral content in CT indicate a significantly accelerated maturation of the regenerate in the ultrasound stimulated group even when a Bonferroni-Holm adjustment was used for multiple testing. CONCLUSION: Pulsed low-intensity ultrasound appears to stimulate the healing processes in the regenerate in this animal model and may have applicability in clinical practice.

Animals↗

Effects of neck movements on stability and subsidence in cervical interbody fusion: an in vitro study.

OBJECT: The aim of this in vitro study was to determine the influence of simulated postoperative neck movements on the stabilizing effect and subsidence of four different anterior cervical interbody fusion devices. Emphasis was placed on the relation between subsidence and spinal stability. METHODS: The flexibility of 24 human cervical spine specimens was tested before and directly after being stabilized with a WING, BAK/C, AcroMed I/F cage, or with bone cement in standard flexibility tests under 50 N axial preload. Thereafter, 700 pure moment loading cycles (+/- 2 Nm) were applied in randomized directions to simulate physiological neck movements. Additional flexibility tests in combination with measurements of the subsidence depth were conducted after 50, 100, 200, 300, 500, and 700 loading cycles. In all four groups, simulated postoperative neck movements caused an increase of the range of motion (ROM) ranging from 0.4 to 3.1 degrees and of the neutral zone from 0.1 to 4.2 degrees. This increase in flexibility was most distinct in extension followed by flexion, lateral bending, and axial rotation. After cyclic loading, ROM tended to be lower in the group fitted with AcroMed cages (3.3 degrees in right lateral bending, 3.5 degrees in left axial rotation, 7.8 degrees in flexion, 8.3 degrees in extension) and in the group in which bone cement was applied (5.4 degrees, 2.5 degrees, 7.4 degrees, and 8.8 degrees, respectively) than in those fixed with the WING (6.3 degrees, 5.4 degrees, 9.7 degrees, and 6.9 degrees, respectively) and BAK cages (6.2 degrees, 4.5 degrees, 10.2 degrees, and 11.6 degrees, respectively). CONCLUSIONS: Simulated repeated neck movements not only caused an increase of the flexibility but also subsidence of the implants into the adjacent vertebrae. The relation between flexibility increase and subsidence seemed to depend on the implant design: subsiding BAK/C cages partially supported stability whereas subsiding WING cages and AcroMed cages did not.

Biomechanical Phenomena↗

Subsidence resulting from simulated postoperative neck movements: an in vitro investigation with a new cervical fusion cage.

STUDY DESIGN: A biomechanical in vitro subsidence test of different cervical interbody fusion devices was performed using a new testing protocol that simulates physiologic conditions. OBJECTIVES: To investigate the effect of simulated postoperative neck movements on the subsidence of the new WING cervical interbody fusion cage in comparison with two other cages and bone cement. SUMMARY OF BACKGROUND DATA: Cervical interbody fusion cages sometimes cause complications because of subsidence into the adjacent vertebrae with collapse of the intervertebral space. Complications such as cage dislocation or nonunion with instability also have been reported. To prevent such complications, the new WING cervical interbody fusion cage (Medinorm AG, Quierschied, Germany) has been developed. Its area of contact with the adjacent vertebrae is supposed to be large enough to resist excessive subsidence and small enough to prevent stress protection of the tissue growing in the cage. METHODS: In this study, 24 human cervical spine specimens were tested after stabilization with either a WING, BAK/C, AcroMed I/F cage or bone cement. Then, in a new testing protocol, 700 pure-moment loading cycles (+/-2 Nm) were applied in randomized directions (lateral bending, flexion-extension, and axial rotation alone or in combination with each other) to simulate the patient's neck movements during the first few postoperative days. Measurements of the subsidence depth (total height loss) in combination with flexibility tests (+/-2.5 Nm) were performed before cyclic loading and after 50, 100, 200, 300, 500, and 700 loading cycles. RESULTS: Cyclic loading caused subsidence in all four device groups, most distinct with BAK/C-cages (1.63 mm after 700 loading cycles) followed by the new WING (0.90 mm) and the AcroMed (0.82 mm) cages. No statistically significant difference could be found among the three cage designs. However, all three cage types showed a significantly higher subsidence depth than bone cement (0.48 mm;P = 0.023 between each of the three cage-types and bone cement). A moderate correlation between bone mineral density and subsidence depth could be found only in the BAK/C group (r2 = 0.495). A large subsidence depth after 700 loading cycles was associated with a large flexibility increase in the WING (r2 = 0.786) and AcroMed groups (r2 = 0.21), but with a small flexibility increase in the BAK/C group (r2 = 0.58). CONCLUSIONS: Postoperative neck movements caused subsidence in all cervical interbody implant types. The new WING cage and the AcroMed cage seemed to have a better resistance against subsidence than the BAK/C cage. However, all three cage types had a significantly higher subsidence tendency than bone cement.

Bone Cements↗

Effects of specimen length on the monosegmental motion behavior of the lumbar spine.

STUDY DESIGN: An in vitro biomechanical analysis of the segmental motion behavior of the same segments in polysegmental (five segments), bisegmental, and monosegmental specimens using sheep lumbosacral spines. OBJECTIVES: To investigate the effect of specimen length on monosegmental motion behavior. These data may be helpful in planning in vitro tests and in comparing results of studies using specimens of different lengths. SUMMARY OF BACKGROUND DATA: The length of spinal specimens used for in vitro stability tests varies greatly, depending on the purpose of the study. Some investigators prefer testing specimens with one adjacent segment on either end of the region of interest. Others favor specimens as short as possible. METHODS: In a first step, seven sheep spine specimens, L3-S1 (note that sheep spines normally have seven lumbar vertebrae), each were tested without preload in a spine-loading apparatus. Alternating sequences of pure lateral bending, flexion/extension, and axial rotation moments (+/-3.75 Nm) were applied continuously. The motion in each single segment was measured simultaneously. Then, these polysegmental specimens were cut into two bisegmental specimens, L3-L5 and L6-S1, and tested in the same way. Finally, another vertebra was removed to obtain two monosegmental specimens, L3-L4 and L7-S1, and to test them as described. RESULTS: In general, the range of motion at L3-L4 and L7-S1 was smaller when tested in polysegmental than in monosegmental specimens. In polysegmental specimens (five segments), the range of motion at L3-L4 and L7-S1 was approximately 80% (range, 70.6-92.5%) and in bisegmental specimens approximately 95% (range, 66.7-100%) of their range of motion measured in monosegmental specimens. Neutral zone and coupled motions showed the inverse behavior. Significant differences were found. However, they were not consistent with either the loading direction or with the specimen length. CONCLUSIONS: For comparison of results, the specimen length should be kept constant within one experiment. Segmental motion behavior of specimens with different lengths should be compared only qualitatively.

Animals↗

[Mechanical modification of callus healing].

Interfragmentary movement and size of the fracture gap influence fracture healing. Limited movements promote callus formation and may result in increased mechanical stability. Although larger movements still promote callus formation, the bony consolidation of the fracture is hampered. Fracture healing is also hampered if the size of the fracture gap is too large. A combination of large movement and large gap bears the risk of non-union. Therefore, having in mind a minimally invasive surgical approach, one should strive for good reduction of the fracture ends and flexible yet stable osteosynthesis. Dynamization of the fracture by enabling axial movement will close the fracture gap, stimulate tissue differentiation and possibly accelerate the healing process. External mechanical stimulation, however, has not been shown to effectively enhance the healing process under flexible fixation or in load-bearing patients.

Animals↗

[In vitro cell behavior of human osteoblasts after physiological dynamic stretching].

The cell activity of human bone derived cell cultures was studied after mechanical stimulation by cyclic strain at a magnitude occurring in physiologically loaded bone tissue. Monolayers of subconfluently grown human bone derived cells were stretched in rectangular silicone dishes with cyclic uniaxial movement along their longitudinal axes. Strain was applied over two days for 30 min per day with a frequency of 1 Hz and a strain magnitude of 1000 mustrain. Cyclic stretching of the cells resulted in an increased proliferation (10-48%) and carboxyterminal collagen type I propeptide release (7-49%) of human cancellous bone derived osteoblasts while alkaline phosphatase activity and osteocalcin release were significantly reduced by 9-25% and 5-32% respectively. These results demonstrate that cyclic strain at physiologic magnitude leads to an increase of osteoblast activities related to matrix production while those activities which are characteristic for the differentiated osteoblast and relevant for matrix mineralization are decreased.

Adult↗

Vertebral body replacement with a bioglass-polyurethane composite in spine metastases--clinical, radiological and biomechanical results.

Metastatic spine lesions frequently require corpectomy in order to achieve decompression of the spinal cord and restoration of spinal stability. A variety of systems have been developed for vertebral body replacement. In patients with prolonged life expectancy due to an improvement of both systemic and local therapy, treatment results can be impaired by a loosening at the implant-bone interface or mechanical failure. Furthermore, early detection of a metastatic recurrence using sensitive imaging modalities like computed tomography (CT) and magnetic resonance imaging (MRI) is possible in these patients without artefact interference. The aim of our pilot study was to evaluate the clinical applicability and results of a new radiolucent system for vertebral body replacement in the lumbar spine. The system consists of bone-integrating biocompatible materials - a polyetherurethane/bioglass composite (PU-C) replacement body and an integrated plate of carbon-fibre reinforced polyetheretherketone (CF-PEEK) - and provides high primary stability with anterior instrumentation alone. In a current prospective study, five patients with metastatic lesions of the lumbar spine were treated by corpectomy and reconstruction using this new system. Good primary stability was achieved in all cases. Follow-up (median 15 months) using CT and MRI revealed progressive osseous integration of the PU-C spacer in four patients surviving more than 6 months. Results obtained from imaging methods were confirmed following autopsy by biomechanical investigation of an explanted device. From these data, it can be concluded that implantation of the new radiolucent system provides sufficient long-term stability for the requirements of selected tumour patients with improved prognosis.

Adult↗

Primary stabilizing effect of interbody fusion devices for the cervical spine: an in vitro comparison between three different cage types and bone cement.

Interbody fusion cages are small hollow implants that are inserted into the intervertebral space to restore physiological disc height and to allow bony fusion. They sometimes cause clinical complications due to instability, subsidence or dislocation. These are basic biomechanical parameters, which influence strongly the quality of a fusion device; however, only few data about these parameters are available. Therefore, the purpose of the present study was to investigate the primary stabilizing effect of four different cervical fusion devices in in vitro flexibility tests. Twenty-four human cervical spine segments were used in this study. After anterior discectomy, fusion was performed either with a WING cage (Medinorm AG, Germany), a BAK/C cage (Sulzer SpineTech, USA), an AcroMed cervical I/F cage (DePuy AcroMed International, UK) or bone cement (Sulzer, Switzerland). All specimens were tested in a spine tester in the intact condition and after implantation of one of the four devices. Alternating sequences of pure lateral bending, flexion-extension and axial rotation moments (+/- 2.5 Nm) were applied continuously and the motions in each segment were measured simultaneously. In general, all tested implants had a stabilizing effect. This was most obvious in lateral bending, where the range of motion was between 0.29 (AcroMed cage) and 0.62 (BAK/C cage) with respect to the intact specimen (= 1.00). In lateral bending, flexion and axial rotation, the AcroMed cervical I/F cages had the highest stabilizing effect, followed by bone cement, WING cages and BAK/C cages. In extension, specimens fused with bone cement were most stable. With respect to the primary stabilizing effect, cages, especially the AcroMed I/F cage but also the WING cage and to a minor extent the BAK/C cage, seem to be a good alternative to bone cement in cervical interbody fusion. Other characteristics, such as the effect of implant design on subsidence tendency and the promotion of bone ingrowth, have to be determined in further studies.

Biomechanical Phenomena↗

Biomechanical evaluation of a new modular rod-screw implant system for posterior instrumentation of the occipito-cervical spine: in-vitro comparison with two established implant systems.

Posterior instrumentation of the occipito-cervical spine has become an established procedure in a variety of indications. The use of rod-screw systems improved posterior instrumentation as it allows optimal screw positioning adapted to the individual anatomic situation. However, there are still some drawbacks concerning the different implant designs. Therefore, a new modular rod-screw implant system has been developed to overcome some of the drawbacks of established systems. The aim of this study was to evaluate whether posterior internal fixation of the occipito-cervical spine with the new implant system improves primary biomechanical stability. Three different internal fixation systems were compared in this study: the CerviFix System, the Olerud Cervical Rod Spinal System and the newly developed Neon Occipito Cervical System. Eight human cervical spine CO/C5 specimens were instrumented from C0 to C4 with occipital fixation, transarticular screws in C1/C2 and lateral mass or pedicle screws in C3 and C4. The specimens were tested in flexion/extension, axial rotation, and lateral bending using pure moments of +/- 2.5 Nm without axial preload. After testing the intact spine, the different instrumentations were tested after destabilising C0/C2 and C3/C4. Primary stability was significantly increased, in all load cases, with the new modular implant system compared to the other implant systems. Pedicle screw instrumentation tended to be more stable compared to lateral mass screws; nevertheless, significant differences were observed only for lateral bending. As the experimental design precluded any cyclic testing, the data represent only the primary stability of the implants. In summary, this study showed that posterior instrumentation of the cervical spine using the new Neon Occipito Cervical System improves primary biomechanical stability compared to the CerviFix System and the Olerud Cervical Rod Spinal System.

Biomechanical Phenomena↗

Load-displacement properties of the normal and injured lower cervical spine in vitro.

The objective of this study was to determine which discoligamentous structures of the lower cervical spine provide significant stability with regard to different loading conditions. Accordingly, the load-displacement properties of the normal and injured lower cervical spine were tested in vitro. Four artificially created stages of increasing discoligamentous instability of the segment C5/6 were compared to the normal C5/6 segment. Six fresh human cadaver spine segments C4-C7 were tested in flexion/extension, axial rotation, and lateral bending using pure moments of +/- 2.5 Nm without axial preload. Five conditions were investigated consecutively: (1) the intact functional spinal unit (FSU) C5/6; (2) the FSU C5/6 with the anterior longitudinal ligament and the intertransverse ligaments sectioned; (3) the FSU C5/6 with an additional 10-mm-deep incision of the anterior half of the anulus fibrosus and the disc; (4) the FSU C5/6 with additionally sectioned ligamenta flava as well as interspinous and supraspinous ligaments; (5) the FSU C5/6 with additional capsulotomy of the facet joints. In flexion/extension, significant differences were observed concerning range of motion (ROM) and neutral zone (NZ) for all four stages of instability compared to the intact FSU. In axial rotation, only the stage 4 instability showed a significantly increased ROM and NZ compared to the intact FSU. For lateral bending, no significant differences were observed. Based on these data, we conclude that flexion/extension is the most sensitive load-direction for the tested discoligamentous instabilities.

Aged↗

Dynamic cell stretching increases human osteoblast proliferation and CICP synthesis but decreases osteocalcin synthesis and alkaline phosphatase activity.

The cell activity of human-bone-derived cell cultures was studied after mechanical stimulation by cyclic strain at a magnitude occurring in physiologically loaded bone tissue. Monolayers of subconfluently grown human-bone-derived cells were stretched in rectangular silicone dishes with cyclic predominantly uniaxial movement along their longitudinal axes. Strain was applied over two days for 30 min per day with a frequency of 1 Hz and a strain magnitude of 1000 microstrain. Cyclic stretching of the cells resulted in an increased proliferation (10-48%) and carboxyterminal collagen type I propeptide release (7-49%) of human-cancellous bone-derived osteoblasts while alkaline phosphatase activity and osteocalcin release were significantly reduced by 9-25 and 5-32%, respectively. These results demonstrate that cyclic strain at physiologic magnitude leads to an increase of osteoblast activities related to matrix production while those activities which are characteristic for the differentiated osteoblast and relevant for matrix mineralization are decreased.

Alkaline Phosphatase↗

Initial stability of fully and partially cemented femoral stems.

OBJECTIVE: To test the initial stability of a newly designed partially cemented femoral stem in comparison with a fully cemented conventional stem. DESIGN: An in vitro study to determine the interface motion between femoral stem and bone as a response to loading. BACKGROUND: The aim of the new prosthesis design is a proximal load transfer by a defined partial cement fixation in the proximal femur region and a slim prosthesis stem in the distal region. Before a clinical study can be started, the new stem has to show an initial stability comparable to that of fully cemented prostheses. METHOD: Six paired fresh cadaveric femora were used for the testing of the new partially cemented stem (Option 3000, Mathys Orthopaedics, Bettlach, Switzerland) and a fully cemented stem (Weber Shaft, AlloPro, Baar, Swizerland). Under cyclic loading up to 1600 N hip joint forces, the interface motion between implants and bone was measured at six locations. RESULTS: Both stems showed uncritical interface motions below 43 microm. However, the Option 3000 stem exhibited significantly smaller motions in the proximal region and slightly larger movements in the distal regions than the Weber prosthesis. CONCLUSIONS: The new type of partially cemented stem provided a comparable initial stability to the fully cemented Weber prosthesis. Relevance The high initial stability of the Option 3000 stem justified the clinical use of the new implant. More than 100 implantations in the last three years, with very good preliminary clinical results, support the preclinical findings.

Aged↗

Comparative stability of the "Internal Fixator" and the "Universal Spine System" and the effect of crosslinking transfixating systems. A biomechanical in vitro study.

In this study, the three-dimensional stabilizing capabilities of the AO-Internal Fixator (IF) and the new Universal Spine System (USS) were investigated. Both devices were tested without and with the cross-link system (IF, IFC, USS, USSC). To determine biomechanical characteristics, a human thoracolumbar spine instability model with resection of the vertebral body Th12 was created. The vertebral body was replaced by a spacer and transpedicular posterior stabilization was performed from Th11 to L1. All devices reduced the range of motion (ROM) significantly compared to the values of the intact specimen. In flexion the IFC showed the highest reduction of ROM (85% of intact), followed by the USSC, USS and IF (79% of intact). In extension the ROM was restored again most by the IFC (52% of intact), followed by the USSC, IF and USS (44% of intact). In lateral bending stability was provided by the USSC (right 78% and left 81% of intact), followed in right lateral bending by the IF, IFC and USS and in left lateral bending by the USS, IF and IFC. In axial rotation the ROM was reduced primary by the IFC (right 51% and left 46% of intact), followed in right axial rotation by the USS, USSC and IF, in left axial rotation by the USSC, USS and IF. Additional stability by crosslinking has been provided in the IF and the USS in flexion and extension, in the USS in lateral bending and in the IF in axial rotation nonsignificantly. The neutral zone (NZ) was reduced by posterior instrumentation in flexion/extension and right/left lateral bending significantly. In axial rotation only the USSC decreased the NZ below intact levels. The study showed no statistical significant differences in the stabilizing capabilities of the USS compared to the IF. For both implants the cross-link system increased stability in the chosen instability model insignificantly only.

Aged↗

Stabilizing effect of posterior lumbar interbody fusion cages before and after cyclic loading.

OBJECT: The function of interbody fusion cages is to stabilize spinal segments primarily by distracting them as well as by allowing bone ingrowth and fusion. An important condition for efficient formation of bone tissue is achieving adequate spinal stability. However, the initial stability may be reduced due to repeated movements of the spine during everyday activity. Therefore, in addition to immediate stability, stability after cyclic loading is of remarkable relevance; however, this has not yet been investigated. The object of this study was to investigate the immediate stabilizing effect of three different posterior lumbar interbody fusion cages and to clarify the effect of cyclic loading on the stabilization. METHODS: Before and directly after implantation of a Zientek, Stryker, or Ray posterior lumbar interbody fusion cage, 24 lumbar spine segment specimens were each evaluated in a spine tester. Pure lateral bending, flexion-extension, and axial rotation moments (+/- 7.5 Nm) were applied continuously. The motion in each specimen was measured simultaneously. The specimens were then loaded cyclically (40,000 cycles, 5 Hz) with an axial compression force ranging from 200 to 1000 N. Finally, they were tested once again in the spine tester. CONCLUSIONS: In general, a decrease of movement in all loading directions was noted after insertion of the Zientek and Ray cages and an increase of movement after implantation of a Stryker cage. In all three cage groups greater stability was demonstrated in lateral bending and flexion than in extension and axial rotation. Reduced stability during cyclic loading was observed in all three cage groups; however, loss of stability was most pronounced when the Ray cage was used.

Exercise Test↗

The influence of stiffness of the fixator on maturation of callus after segmental transport.

The treatment of large bony defects by callus distraction is well accepted, but the duration of treatment is long and the rate of complications increases accordingly. We have examined the effect of the stiffness of the axial fixator on reducing the time for maturation of callus. We created a mid-diaphyseal defect of 15 mm in the metatarsal bone in sheep and stabilised it with a ring fixator. After four days a bony segment was transported for 16 days at 1 mm per day. After 64 days the animals were divided into four groups, three with axial interfragmentary movement (IFM) of 0.5, 1.2 and 3.0 mm, respectively, and a control group. The 3.0 mm IFM group had the smallest bone density (p = 0.001) and area of callus and the largest IFM after 12 weeks; it also had typical clinical signs of hypertrophic nonunion. The most rapid stiffening of the callus was in the 0.5 mm group which had the smallest IFM (p = 0.04) after 12 weeks and radiological signs of bridging of the defect. These results indicate that suitable dynamic axial stimulation can enhance maturation of distraction callus when the initial amplitude is small, but that a large IFM can lead to delayed union.

Animals↗