Computerized color perimetry in multiple sclerosis.

Color visual field analysis has proven highly sensitive for early visual impairments diagnosis in MS, yet it has never attained widespread popularity usually because the procedure is difficult to standardize, the devices are costly, and the test is fatiguing. We propose a computerized procedure running on standard PC, cost effective, clonable, and easy handled. Two hundred and sixty-four colored patches subtending 1 degree angle vision, with selected hues and low saturation levels are sequentially and randomly displayed on gray equiluminous background of the PC screen subtending 24 degrees x 40 degrees angle of vision. The subject is requested to press a switch at the perception of the stimulus. The output provides colored maps with quantitative information. Comparison between normals and a selected population of MS patients with no actual luminance visual field defects, showed high statistical difference.

Adolescent↗

On-line analysis of AEP and EEG for monitoring depth of anaesthesia.

Achieving and monitoring adequate depth of anaesthesia is a challenge to the anaesthetist. With the introduction of muscle relaxing agents, the traditional signs of awareness are often obscured or difficult to interpret. These signs include blood pressure, heart rate, pupil size, etc. However, these factors do not describe the depth of anaesthesia, (DA), in a cerebral activity sense, hence there is a desire to achieve a better measure of the DA. Auditory Evoked Potentials (AEP) provide two aspects relevant to anaesthesia: (1) they have identifiable anatomical significance and, (2) their characteristics reflect the way in which the brain reacts to a stimulus. However, AEP is embedded in noise from the ongoing EEG background activity. Hence, processing is needed to improve the signal to noise ratio. The methods applied were moving time averaging (MTA) and ARX-modeling. The EEG was collected from the left hemisphere and analysed by FFT to 1 sec epochs and the spectral edge frequency was calculated. Both the changes in ARX extracted AEP and the spectral edge frequency of the EEG correlated well with the time interval between propofol induction and onset of anaesthesia measured by clinical signs (i.e., cessation of eye-lash reflex). The MTA extracted AEP was significantly slower in tracing the transition from consciousness to unconsciousness.

Anesthesia↗

Reduction of ocular artefacts in source current density brain mappings by ARX2 filtering.

Sweep by sweep analysis of event-related potentials (ERP) of the human scalp represents a reliable tool for both the diagnosis of neurologic diseases and the study of the central nervous system during cognitive tasks. The off-line procedure based on stochastic parametric identification and filtering herewith described, allows an accurate analysis of single-sweep ERP and a drastic reduction of ocular artefacts variously propagating through the skull. Moreover, the spatial distribution of the recorded ERP in bidimensional form was enhanced by using the Laplacian operator in order to get an estimate of the source current density (SCD) flow from the skull into the scalp. Complete single-trial signals were filtered according to an autoregressive model of signal generation with 2 exogenous inputs (ARX2). The ARX2 procedure models the recorded signal as the sum of three signals: (a) the background EEG activity, modelled as an autoregressive process driven by a white noise; (b) a filtered version of a reference signal carrying the average information contained in each sweep; (c) a signal due to the ocular artefact propagation. The evaluation of the effect of artefact suppression on those channels close to the eyes was compared with standard ordinary least squares method (OLS) based on a linear model of the influence of EOG on ERP. Finally, the better results obtainable through ARX filtering on sweep-by-sweep brain mappings are also presented.

Adult↗

ARX filtering of single-sweep movement-related brain macropotentials in mono- and multi-channel recordings.

A technique of stochastic parametric identification and filtering is applied to the analysis of single-sweep event-related potentials. This procedure, called AutoRegressive with n eXogenous inputs (ARXn), models the recorded signal as the sum of n+1 signals: the background EEG activity, modeled as an autoregressive process driven by white noise, and n signals, one of which represents a filtered version of a reference signal carrying the average information contained in each sweep. The other (n-1) signals could represent various sources of noise (i.e., artifacts, EOG, etc.). An evaluation of the effects of both artifact suppression and accurate selection of the average signal on mono- or multi-channel scalp recordings is presented.

Brain Mapping↗

Automatic visual field: a software diagnostic procedure.

A recently developed technique for the automatic acquisition of data on visual field losses was tested, with reliable neuro-ophthalmological parameters, on 300 subjects with and without eye disorders. Algorithms for acquisition and processing of the central visual field were implemented on an IBM-AT personal computer with standard peripherals. The contours of scotomata (visual field losses) were best estimated by probabilistic adaptive enhancement of data sampling in those areas with greater visual variability. Image processing tools were specially designed to extract information concerning the size, shape, position and number of scotomata in the visual field. The diagnosis of wider campimetric lesions required parameters such as symmetry or specularity coefficients, obtainable by analysing the visual field of both eyes. Data obtained were correlated to the pathology involved by univariate statistical tools.

Algorithms↗

Changes in visual evoked potentials in children on chronic dialysis treatment.

Visual evoked potentials (VEP) were recorded in 20 children undergoing dialysis for chronic renal failure. VEP before treatment (72 h after last dialysis) were pathological in 17 patients (85%); responses obtained 3 h after treatment were abnormal in only 6 cases (30%). Furthermore, all patients improved after treatment, except two who were unchanged. However, VEP recorded immediately after dialysis were worse in 4 of 7 patients than before treatment, probably as an effect of the dysequilibrium syndrome; they improved spontaneously afterwards. The acute changes caused by dialysis seem to be more evident in children than in adults. No correlations have been found between blood chemistry indexes and VEP modifications. Finally, VEP have proved to be more sensitive than EEG in identifying a central nervous system (CNS) dysfunction in these uremic patients.

Adolescent↗

Use of urea kinetic model and haemofiltration to improve nitrogen balance in haemodialysed children.

To improve nitrogen balance and nutritional status, 10 paediatric patients (11.2 +/- 2.7 years; 28.5 +/- 5.1 kg) on regular haemodialysis (HD) for 25.3 +/- 1.2 months were treated with haemofiltration (HF) for 12.2 +/- 3.4 months. HF was prescribed using a urea kinetic model to ensure a pre-treatment blood urea nitrogen (BUN) of 130 mg/100ml. Urea generation rate (Gu) and protein catabolic rate (PCR) were computed by urea kinetics. Protein and calorie intake was assessed in the children on an unrestricted diet by analysis of 10 days' dietary records obtained every two months. During HF treatment a significant decrease of Gu and PCR was obtained and nitrogen balance increased in all the children.

Adolescent↗