Noninvasive versus conventional mechanical ventilation. An epidemiologic survey.

A prospective survey was performed over a period of 3 wk among 42 intensive care units to assess the incidence of use and effectiveness of noninvasive mechanical ventilation (NIV) in clinical practice. All patients requiring ventilatory support for acute respiratory failure (ARF), either with endotracheal intubation (ETI) or NIV, were included. Ventilatory support was required in 689 patients, 581 with ETI and 108 (16%) with NIV (35% of patients not intubated on admission). Reasons for mechanical ventilation were coma (30%), cardiogenic pulmonary edema (7%), and hypoxemic (48%) and hypercapnic ARF (15%). NIV was never used for patients in coma (who were excluded from further analysis), but was used in 14% of patients with hypoxemic ARF, in 27% of those with pulmonary edema, and in 50% of those with hypercapnic ARF. NIV was followed by ETI in 40% of cases. The incidence of both nosocomial pneumonia (10% versus 19%, p = 0.03), and mortality (22% versus 41%, p < 0.001) was lower in NIV patients than in those with ETI. After adjusting for differences at baseline, Simplified Acute Physiology Score (SAPS) II (odds ratio [OR] = 1.05 per point; confidence interval [CI]: 1.04 to 1.06), McCabe/Jackson score (OR = 2.18; CI: 1.57 to 3.03), and hypoxemic ARF (OR = 2.30; CI: 1.33 to 4.01) were identified as risk factors explaining mortality; success of NIV was associated with a lower risk of pneumonia (OR = 0.06; CI: 0.01 to 0.45) and of death (OR = 0.16; CI: 0.05 to 0.54). In NIV patients, SAPS II and a poor clinical tolerance predicted secondary ETI. Failure of NIV was associated with a longer length of stay. In conclusion, NIV can be successful in selected patients, and is associated with a lower risk of pneumonia and death than is ETI.

Aged↗

Influence of tidal volume on alveolar recruitment. Respective role of PEEP and a recruitment maneuver.

Both reduction in tidal volume (VT) and alveolar recruitment may be important to limit ventilator-associated lung injury during mechanical ventilation of patients with the acute respiratory distress syndrome (ARDS). The aim of this study was to assess the risk of alveolar derecruitment associated with VT reduction from 10 to 6 ml/kg. Whether this VT-related derecruitment could be reversed, either by a recruitment maneuver or by an increase in positive end-expiratory pressure (PEEP) level, was also investigated. Fifteen patients with ARDS were successively ventilated using conventional VT (CVT = 10 +/- 1 ml/kg) and low VT (LVT = 6 +/- 1 ml/ kg); total PEEP (PEEPtot) was individually set at the lower inflection point (Plip) of the pressure-volume curve (PEEPtot = 11 +/- 4 cm H(2)O). Pressure-volume curves were recorded from zero PEEP (ZEEP) and from PEEP, and recruited volume (Vrec) was calculated as the volume difference between the two curves for a given pressure. Despite a similar PEEPtot, Vrec was significantly lower with LVT than with CVT, indicating low VT-induced alveolar derecruitment. Reduction in VT was associated with a reduced Sa(O(2)). In 10 patients, Vrec was also measured before and after a recruitment maneuver (two sustained inflations at 45 cm H(2)O), and after an increase in PEEP (by 4 cm H(2)O). Low VT-induced derecruitment was reversed by a recruitment maneuver and by increasing PEEP. We conclude that a reduction in VT could be responsible for alveolar derecruitment, which may be transiently reversed by a reexpansion maneuver or prevented by a PEEP increase above Plip.

Adult↗

Vascular endothelial growth factor synthesis in the acute phase of experimental and clinical lung injury.

Vascular endothelial growth factor (VEGF) is a potent angiogenic and endothelial survival factor, which is abundantly expressed in the normal lung. Conceivably, VEGF may be released by numerous cell types found around the airspaces, including alveolar type 2 cells, alveolar macrophages, and polymorphonuclear neutrophils. Using a bacteria-induced lung injury model in rats, VEGF expression in lung was investigated. Both VEGF protein and VEGF messenger ribonucleic acid (mRNA), 4 and 24 h after bacterial challenge (Pseudomonas aeruginosa), were decreased compared with sham rats. VEGF protein was also investigated in bronchoalveolar lavage (BAL) from patients studied within 7 days of acute respiratory distress syndrome (ARDS) onset and in patients without ARDS. VEGF protein levels in BAL were decreased in patients with ARDS versus those without (14.3 +/- 11.1 pg x mL(-1) versus 76.8 +/- 51.1 pg x mL(-1), p = 0.03). In aggregate, these findings show that the initial phase of acute lung injury is associated with a decrease in vascular endothelial growth factor in the lung. This downregulation may represent a protective mechanism aimed at limiting endothelial permeability, and may participate in the decrease in capillary number that is observed during early acute respiratory distress syndrome.

Animals↗

Pressure-volume curve: methods and meaning.

The pressure-volume curve of the respiratory system is a physiological method used for diagnotic purposes to describe the static mechanical properties of the respiratory system. A renewal of interest in the pressure-volume curve has recently appeared because of experimental evidence regarding the information conveyed by the curve, a better understanding of the pathophysiologic factors influencing its interpretation and the beneficial results of clinical trials based on the use of the pressure-volume curve for ventilatory management of acute respiratory distress syndrome. Thus, adapting ventilatory settings to individual characteristics of the patients in terms of respiratory mechanics may be an extremely important aspect for a better management of the most difficult to ventilate patients with acute lung injury. There is considerable experimental evidence that both the opening-collapse phenomena and the excessive lung stretch may cause damage to the lungs. Therefore tools allowing an individual titration of ventilatory settings taking into account the constraints of the respiratory system seem highly desirable. The pressure-volume curve might be easily achievable at the bedside as a monitoring tool. The low-flow technique using ventilator technology has several potential advantages. It is hopeful to think that in the future the measurement of the P-V curve and the quantification of alveolar recruitment may be easily provided at the bedside and may help for the titration of the ventilatory settings in clinical practice. This review will focus briefly on the physiologic background, technique description, and recent advances concerning the interpretation of the P-V curve in the critically ill patients.

Humans↗

Treatment of acute hypoxemic nonhypercapnic respiratory insufficiency with continuous positive airway pressure delivered by a face mask: A randomized controlled trial.

CONTEXT: Continuous positive airway pressure (CPAP) is widely used in the belief that it may reduce the need for intubation and mechanical ventilation in patients with acute hypoxemic respiratory insufficiency. OBJECTIVE: To compare the physiologic effects and the clinical efficacy of CPAP vs standard oxygen therapy in patients with acute hypoxemic, nonhypercapnic respiratory insufficiency. DESIGN, SETTING, AND PATIENTS: Randomized, concealed, and unblinded trial of 123 consecutive adult patients who were admitted to 6 intensive care units between September 1997 and January 1999 with a PaO(2)/FIO(2) ratio of 300 mm Hg or less due to bilateral pulmonary edema (n = 102 with acute lung injury and n = 21 with cardiac disease). INTERVENTIONS: Patients were randomly assigned to receive oxygen therapy alone (n = 61) or oxygen therapy plus CPAP (n = 62). MAIN OUTCOME MEASURES: Improvement in PaO(2)/FIO(2) ratio, rate of endotracheal intubation at any time during the study, adverse events, length of hospital stay, mortality, and duration of ventilatory assistance, compared between the CPAP and standard treatment groups. RESULTS: Among the CPAP vs standard therapy groups, respectively, causes of respiratory failure (pneumonia, 54% and 55%), presence of cardiac disease (33% and 35%), severity at admission, and hypoxemia (median [5th-95th percentile] PaO(2)/FIO(2) ratio, 140 [59-288] mm Hg vs 148 [62-283] mm Hg; P =.43) were similarly distributed. After 1 hour of treatment, subjective responses to treatment (P<.001) and median (5th-95th percentile) PaO(2)/FIO(2) ratios were greater with CPAP (203 [45-431] mm Hg vs 151 [73-482] mm Hg; P =.02). No further difference in respiratory indices was observed between the groups. Treatment with CPAP failed to reduce the endotracheal intubation rate (21 [34%] vs 24 [39%] in the standard therapy group; P =.53), hospital mortality (19 [31%] vs 18 [30%]; P =.89), or median (5th-95th percentile) intensive care unit length of stay (6.5 [1-57] days vs 6.0 [1-36] days; P =.43). A higher number of adverse events occurred with CPAP treatment (18 vs 6; P =.01). CONCLUSION: In this study, despite early physiologic improvement, CPAP neither reduced the need for intubation nor improved outcomes in patients with acute hypoxemic, nonhypercapnic respiratory insufficiency primarily due to acute lung injury. JAMA. 2000;284:2352-2360.

APACHE↗

Association of noninvasive ventilation with nosocomial infections and survival in critically ill patients.

CONTEXT: Invasive life-support techniques are a major risk factor for nosocomial infection. Noninvasive ventilation (NIV) can be used to avoid endotracheal intubation and may reduce morbidity among patients in intensive care units (ICUs). OBJECTIVE: To determine whether the use of NIV is associated with decreased risk of nosocomial infections and improved survival in everyday clinical practice among patients with acute exacerbation of chronic obstructive pulmonary disease (COPD) or hypercapnic cardiogenic pulmonary edema (CPE). DESIGN AND SETTING: Matched case-control study conducted in the medical ICU of a French university hospital from January 1996 through March 1998. PATIENTS: Fifty patients with acute exacerbation of COPD or severe CPE who were treated with NIV for at least 2 hours and 50 patients treated with mechanical ventilation between 1993 and 1998 (controls), matched on diagnosis, Simplified Acute Physiology Score II, Logistic Organ Dysfunction score, age, and no contraindication to NIV. MAIN OUTCOME MEASURES: Rates of nosocomial infections, antibiotic use, lengths of ventilatory support and of ICU stay, ICU mortality, compared between cases and controls. RESULTS: Rates of nosocomial infections and of nosocomial pneumonia were significantly lower in patients who received NIV than those treated with mechanical ventilation (18% vs 60% and 8% vs 22%; P<.001 and P =.04, respectively). Similarly, the daily risk of acquiring an infection (19 vs 39 episodes per 1000 patient-days; P =.05), proportion of patients receiving antibiotics for nosocomial infection (8% vs 26%; P =.01), mean (SD) duration of ventilation (6 [6] vs 10 [12] days; P =.01), mean (SD) length of ICU stay (9 [7] vs 15 [14] days; P =.02), and crude mortality (4% vs 26%; P =.002) were all lower among patients who received NIV than those treated with mechanical ventilation. CONCLUSIONS: Use of NIV instead of mechanical ventilation is associated with a lower risk of nosocomial infections, less antibiotic use, shorter length of ICU stay, and lower mortality. JAMA. 2000;284:2361-2367.

APACHE↗

[Performance studies of 6 new anesthesia ventilators: bench tests].

OBJECTIVE: To assess the pneumatic performances of six new anaesthesia ventilators. STUDY DESIGN: Bench test study. MATERIAL: The study included one ventilator operated by an electric motor: ABT 5300 (Kontron); four ventilators of "bellows-in-bottle" category: ADU version 97 (Datex-Ohmeda); Aestiva 3000 (Datex-Ohmeda), Kion (Siemens), the two versions of Julian (Dräger); and an original ventilator devised for quantitative, or self-regulating target controlled inhalation anaesthesia, with a totally closed circuit, made of four ventilating chambers: PhysioFlex (Dräger). METHODS: The bench test included a passive lung model with adjustable compliance and resistances, and flow and pressure gauges. The accuracy of volume and pressure measurements was tested in various conditions of resistance and compliance. RESULTS: Pneumatic performance and accuracy were satisfactory, even in severe ventilatory conditions. All the ventilators, except ABT 5300 and Julian 1, have a compliance compensation system permitting to deliver and to maintain a constant tidal volume under various conditions of downstream load, particularly under maximal load condition. Variations of tidal volume with the increase of the fresh gas flow are negligible. CONCLUSION: Recent technological progress has improved pneumatic performance of anaesthesia ventilators and the marketed models are more homogeneous at present. Ergonomics and training for the use of the machine are becoming major criteria for the global assessment and the choice of a ventilator.

Airway Resistance↗

Efficacy of continuous insufflation of oxygen combined with active cardiac compression-decompression during out-of-hospital cardiorespiratory arrest.

BACKGROUND: During experimental cardiac arrest, continuous insufflation of air or oxygen (CIO) through microcannulas inserted into the inner wall of a modified intubation tube and generating a permanent positive intrathoracic pressure, combined with external cardiac massage, has previously been shown to be as effective as intermittent positive pressure ventilation (IPPV). METHODS: After basic cardiorespiratory resuscitation, the adult patients who experienced nontraumatic, out-of-hospital cardiac arrest with asystole, were randomized to two groups: an IPPV group tracheally intubated with a standard tube and ventilated with standard IPPV and a CIO group for whom a modified tube was inserted, and in which CIO at a flow rate of 15 l/min replaced IPPV (the tube was left open to atmosphere). Both groups underwent active cardiac compression-decompression with a device. Resuscitation was continued for a maximum of 30 min. Blood gas analysis was performed as soon as stable spontaneous cardiac activity was restored, and a second blood gas analysis was performed at admission to the hospital. RESULTS: The two groups of patients (47 in the IPPV and 48 in the CIO group) were comparable. The percentages of patients who underwent successful resuscitation (stable cardiac activity; 21.3 in the IPPV group and 27.1% in the CIO group) and the time necessary for successful resuscitation (11.8 +/- 1.8 and 12.8 +/- 1.9 min) were also comparable. The blood gas analysis performed after resuscitation (8 patients in the IPPV and 10 in the CIO group) did not show significant differences. The arterial blood gases performed after admission to the hospital and ventilation using a transport ventilator (seven patients in the IPPV group and six in the CIO group) showed that the partial pressure of arterial carbon dioxide (PaCO2) was significantly lower in the CIO group (35.7 +/- 2.1 compared with 72.7 +/- 7.4 mmHg), whereas the pH and the partial pressure of arterial oxygen (PaO2) were significantly higher (all P < 0.05). CONCLUSIONS: Continuous insufflation of air or oxygen alone through a multichannel open tube was as effective as IPPV during out-of-hospital cardiac arrest. A significantly greater elimination of carbon dioxide and a better level of oxygenation in the group previously treated with CIO probably reflected better lung mechanics.

Adolescent↗

Airway occlusion pressure to titrate positive end-expiratory pressure in patients with dynamic hyperinflation.

BACKGROUND: Although the use of external positive end-expiratory pressure (PEEP) is recommended for patients with intrinsic PEEP, no simple method exists for bedside titration. We hypothesized that the occlusion pressure, measured from airway pressure during the phase of ventilator triggering (P0.1t), could help to indicate the effects of PEEP on the work of breathing (WOB). METHODS: Twenty patients under assisted ventilation with chronic obstructive pulmonary disease were studied with 0, 5, and 10 cm H2O of PEEP while ventilated with a fixed level of pressure support. RESULTS: PEEP 5 significantly reduced intrinsic PEEP (mean +/- SD, 5.2 +/- 2.4 cm H2O at PEEP 0 to 3.6 +/- 1.9 at PEEP 5; P < 0.001), WOB per min (12. 6 +/- 6.7 J/min to 9.1 +/- 5.9 J/min; P = 0.003), WOB per liter (1.2 +/- 0.4 J/l to 0.8 +/- 0.4 J/l; P < 0.001), pressure time product of the diaphragm (216 +/- 86 cm H2O. s-1. min-1 to 155 +/- 179 cm H2O. s-1. min-1; P = 0.001) and P0.1t (3.3 +/- 1.5 cm H2O to 2.3 +/- 1.4 cm H2O; P = 0.002). At PEEP 10, no further significant reduction in muscle effort nor in P0.1t (2.5 +/- 2.1 cm H2O) occurred, and transpulmonary pressure indicated an increase in end-expiratory lung volume. Significant correlations were found between WOB per min and P0.1t at the three levels of PEEP (P < 0.001), and between the changes in P0.1t versus the changes in WOB per min (P < 0.005), indicating that P0.1t and WOB changed in the same direction. A decrease in P0.1 with PEEP indicated a decrease in intrinsic PEEP with a specificity of 71% and a sensitivity of 88% and a decrease in WOB with a specificity of 86% and a sensitivity of 91%. CONCLUSION: These results show that P0.1t may help to assess the effects of PEEP in patients with intrinsic PEEP.

Adult↗

Ventilator circuit and secretion management strategies: a Franco-Canadian survey.

OBJECTIVE: To determine the use of ventilator circuit and secretion management strategies in France and Canada. DESIGN: Binational cross-sectional survey. POPULATION: Intensive care unit (ICU) directors in French and Canadian university hospitals. MEASUREMENTS: We compared responses between countries regarding the use of seven circuit and secretion strategies, the rationales against their use, decisional responsibility for these strategies, whether ventilator-associated pneumonia (VAP) practice was audited, and whether VAP prevention guidelines addressing these strategies were used. RESULTS: The response rate was 72/84 (85.7%) for French and 31/32 (96.9%) for Canadian ICUs. Endotracheal intubation was predominantly oral in both countries. Changing the ventilator circuits only for every new patient was more frequent in France than in Canada (p < .0001). Heated humidifiers were used more in Canada than France (p = .0003). Closed endotracheal suctioning was used more frequently in Canada (p < .0001). In both countries, subglottic secretion drainage and kinetic beds were rarely used. Semirecumbent positioning was reported more often by French than Canadian ICUs (p = .003). Reasons for nonuse of these strategies included adverse effects (heat and moisture exchangers), cost (kinetic beds), lack of convincing benefit (subglottic secretion drainage), and nurse inconvenience (semirecumbency). Decisional responsibility for each strategy differed among institutions. VAP prevention practice was periodically reviewed in 53% of French and 68% of Canadian ICUs (p = .20). VAP prevention guidelines were used in 64% and 30% of these ICUs, respectively (p = .002). CONCLUSIONS: Our study does not support the notion that published recommendations substantially impact reported use of several ventilator circuit and secretion management strategies. Based on the use of more frequent ventilator circuit changes, closed suctioning systems, heated humidifiers, and respiratory therapists, ventilator circuit and secretion management practice appears more costly in Canada than in France.

Canada↗

Clinical evaluation of a computer-controlled pressure support mode.

We have designed a computerized system providing closed-loop control of the level of pressure support ventilation (PSV). The system sets itself at the lowest level of PSV that maintains respiratory rate (RR), tidal volume (VT), and end-tidal CO(2) pressure (PET(CO(2))) within predetermined ranges defining acceptable ventilation (i.e., 12 < RR < 28 cycles/min, VT > 300 ml [> 250 if weight < 55 kg], and PET(CO(2)) < 55 mm Hg [< 65 mm Hg if chronic CO(2) retention]). Ten patients received computer-controlled (automatic) PSV and physician-controlled (standard) PSV, in random order, during 24 h for each mode. An estimation of occlusion pressure (P(0.1)) was recorded continuously. The average time spent with acceptable ventilation as previously defined was 66 +/- 24% of the total ventilation time with standard PSV versus 93 +/- 8% with automatic PSV (p < 0.05), whereas the level of PSV was similar during the two periods (17 +/- 4 cm H(2)O versus 19 +/- 6 cm H(2)O). The time spent with an estimated P(0.1) above 4 cm H(2)O was 34 +/- 35% of the standard PSV time versus only 11 +/- 17% of the automatic PSV time (p < 0.01). Automatic PSV increased the time spent within desired ventilation parameter ranges and apparently reduced periods of excessive workload.

Aged↗

Noninvasive ventilation with helium-oxygen in acute exacerbations of chronic obstructive pulmonary disease.

The use of helium-oxygen (HeO(2)) was tested in combination with noninvasive ventilation (NIV) in 10 patients with acute exacerbation of chronic obstructive pulmonary disease (COPD). Effort to breathe as assessed by the respiratory muscle pressure-time index (PTI), work of breathing (WOB), and gas exchange were the main endpoints. Results of NIV-HeO(2) were compared with those obtained with standard NIV (AirO(2)), at two levels of pressure-support ventilation (PSV), 9 +/- 2 cm H(2)O and 18 +/- 3 cm H(2)O. Significant reductions in PTI were observed between HeO(2) and AirO(2) at both the low PSV level (n = 9; 160 +/- 58 versus 198 +/- 78 cm H(2)O/s/ min; p < 0.05) and the high PSV level (n = 10; 100 +/- 45 versus 150 +/- 82 cm H(2)O/s/min; p < 0.01). WOB also differed significantly between HeO(2) and AirO(2) (7.8 +/- 4.1 versus 10.9 +/- 6.1 J/min at the low PSV level, p < 0.05; and 5.7 +/- 3.3 versus 9.2 +/- 5. J/min, p < 0.01 at the high PSV level). HeO(2) reduced Pa(CO(2)) at both the low PSV level (61 +/- 13 versus 64 +/- 15 mm Hg; p < 0.05) and the high PSV level (56 +/- 13 versus 58 +/- 14 mm Hg; p < 0.05), without significantly changing breathing pattern or oxygenation. We conclude that use of HeO(2) during NIV markedly enhances the ability of NIV to reduce patient effort and to improve gas exchange.

Administration, Inhalation↗

Hemodynamic tolerance of intermittent hemodialysis in critically ill patients: usefulness of practice guidelines.

Poor hemodynamic tolerance of intermittent hemodialysis (IHD) is a common problem for patients in an intensive care unit (ICU). New dialysis strategies have been adapted to chronic hemodialysis patients with cardiovascular insufficiency. To improve hemodynamic tolerance of IHD, specific guidelines were progressively implemented into practice through the year 1996 in our 26-bed medical ICU. To evaluate the efficiency of these guidelines we retrospectively compared all IHD performed during the years before (1995) and after (1997) implementation of these recommendations. Forty-five patients underwent 248 IHD sessions in 1995 and 76 patients underwent 289 IHD sessions in 1997. The two populations were similar for age, sex, chronic hemodialysis (26% versus 17%), and secondary acute renal failure. In 1997, patients were more severely ill with a higher SAPS II (50 +/- 17 versus 59 +/- 24; p = 0.036), and more patients required epinephrine or norepinephrine infusion before dialysis sessions (16% versus 34%; p < 0.0001). The compliance to guidelines was high, inducing a significant change in IHD modalities. As a result, hemodynamic tolerance was significantly better in 1997, with less systolic blood pressure drop at onset (33% versus 21%, p = 0. 002) and during the sessions (68% versus 56%, p = 0.002). IHD with hypotensive episode or need for therapeutic interventions were less frequent in 1997 (71% versus 61%, p = 0.015). The ICU mortality was similar (53.3% in 1995 versus 47.3% in 1997; p = 0.52) but death rate in 1997, but not in 1995, was significantly less than predicted from SAPS II (47.3% versus 65.6%; p = 0.02). Length of ICU stay was also reduced for survivors in 1997 (p = 0.04). Implementation of practice guidelines for intermittent hemodialysis in ICU patients lessens hemodynamic instability and may improve outcome.

Critical Illness↗

Continuous tracheal gas insufflation in preterm infants with hyaline membrane disease. A prospective randomized trial.

In mechanically ventilated neonates, the instrumental dead space is a major determinant of total minute ventilation. By flushing this dead space, continuous tracheal gas insufflation (CTGI) may allow reduction of the risk of overinflation. We conducted a randomized trial to evaluate the efficacy of CTGI in reducing airway pressure over the entire period of mechanical ventilation while maintaining oxygenation. A total of 34 preterm newborns, ventilated in conventional pressure-limited mode, were enrolled in two study arms, to receive or not receive CTGI. Transcutaneous Pa(CO(2)) (tcPa(CO(2))) was maintained at 40 to 46 mm Hg in both groups to ensure comparable alveolar ventilation. Respiratory data were collected several times during the first day and daily until Day 28. Both groups were similar at the time of inclusion. During the first 4 d of the study, the difference between peak pressure and positive end-expiratory pressure was significantly lower in the CTGI group by 18% to 35%, with the same tcPa(CO(2)) level and with no difference in the ratio of tcPa(O(2)) to fraction of inspired oxygen (245 +/- 29 versus 261 +/- 46 mm Hg [mean +/- SD] over the first 4 d). Extubation occurred sooner in the CTGI group (p < 0.05), and the duration of mechanical ventilation was shorter (median: 3.6 d; 25th to 75th quartiles: 1.5 to 12.0 d; versus median: 15.6 d; 25th to 75th quartiles: 7.9 to 22.2; p < 0.05) than in the non-CTGI group. CTGI allows the use of low-volume ventilation over a prolonged period and reduces the duration of mechanical ventilation.

Blood Gas Monitoring, Transcutaneous↗