Search PubMedSearch

Biomedical subjects

L Bolinger

Publications and source records attributed to L Bolinger.

At least 19 recordsLinked to original sources

A novel approach to observing articular cartilage deformation in vitro via magnetic resonance imaging.

The design of a pressure cell that compresses a cartilage specimen in one dimension within an imaging magnet is presented. One-dimensional projection images in a direction perpendicular to the articular surface of the cartilage specimen were used to generate a uniaxial confined deformation creep curve for normal and trypsin-degraded cartilage specimens during a continuous 0.690 MPa (100 psi) pressure application. The resulting curves are shown to fit a two time constant viscoelastic model well and also indicate that the elastic modulus of cartilage decreases and the deformation rate increases upon trypsin proteolysis. Furthermore, cartilage permeability is shown as a function of cartilage strain for both the normal and trypsin-degraded case. Several two-dimensional slice-selective images were collected both before and after 80 minutes of continuous compression. These images were used to evaluate the relative changes in the spin-lattice, T1, and spin-spin, T2, relaxation time constant maps for both normal and degraded cartilage specimens in response to compression. The results of this study demonstrate the utility of a novel, non-magnetic, cartilage compression device and also support the validity of a simple two-component rheological model of articular cartilage.

Animals

Magnetization transfer imaging of the brain: A quantitative comparison of results obtained at 1.5 and 4.0 T.

The preliminary results of magnetization transfer (MT) imaging on a whole body 4.0 T system are presented. Cooked egg phantoms and several volunteers were imaged on 1.5 and 4.0 T magnets interfaced to GE Signa scanners. The MT ratio (MTR), signal difference to noise ratio (SDNR), and contrast parameters were measured at both fields and compared. Furthermore, single-shot Z-spectroscopy was used to characterize the frequency dependence of the MT phenomenon. The results show that MT imaging can be safely performed at 4.0 T without exceeding limitations of radio frequency power. The MT effect is more pronounced at the higher field, leading to better quality images with higher contrast and SDNR. The Z-spectra are not markedly different at the higher field although the MTR is greater. The potential applications of this technique to study neurodegenerative diseases, as well as, perfusion imaging and angiography are discussed. J. Magn. Reson. Imaging 1999;10:527-532.

Brain

High-resolution imaging using Hadamard encoding.

High-resolution imaging techniques using noninvasive modalities such as magnetic resonance (MR) imaging are being pursued as in vivo cancer screening techniques in an attempt to eliminate the invasive nature of surgical biopsy. When acquiring high-resolution MR images for tissue screening, image fields of view have in the past been limited by the matrix sizes available in conventional MR scanners. We present here a technique that uses aliasing to produce high resolution images with larger matrix sizes than are currently available. The image is allowed to alias in both the frequency encoding and phase encoding dimensions, and the individual, aliased fields of view are recovered by Hadamard encoding methods. These fields may then be tiled to obtain a composite image with high spatial resolution and a large field of view. The technique is demonstrated using two-dimensional and three-dimensional in vivo imaging of the human brain and breast.

Brain

Sequence requirements for stabilization of a peptide reverse turn in water solution--proline is not essential for stability.

To probe the sequence requirements for stabilization of a reverse turn conformation in a short peptide in water solution, the behavior of two series of peptides was investigated by nuclear magnetic resonance (NMR) spectroscopy. The peptides have the general sequences XPGDV and AXGDV, where X is a representative subset of all 20 naturally occurring amino acids. The residues chosen at positions 3 and 4, Gly and Asp, respectively, were shown to give the greatest population of reverse turns in a previous study [Dyson, H. J., Rance, M., Houghten, R. A., Lerner, R. A. & Wright, P. E. (1988) J. Mol. Biol. 201, 161-200]. Within this framework, the identity of the first residue of the turn (X in XPGDV) does not greatly influence the turn population, although a small but significant increase is observed for residues such as Ala which have a preference for backbone conformations in the alpha region of (phi,psi) space. The series AXGDV was initially studied for completeness only, since it was expected that the turn would not be stabilized in such a small linear peptide in the absence of proline. In contrast, it appears that a significant population of type II turn conformations is to be found in peptides in the series AXGDV, although proline remains one of the most favorable residues at position 2. These results indicate that while residues at all positions within the turn can influence the turn population, the presence of Gly-Asp as the third and fourth members of the sequence gives a strong bias towards type II turn formation regardless of the residues at positions 1 and 2. Our results give a final prediction that the sequence with the highest intrinsic propensity for turn formation is APGD.

Amino Acid Sequence

Sodium multiple quantum spectroscopy of articular cartilage: effects of mechanical compression.

The effects of mechanical compression on the multiple quantum coherences generated from sodium ions in articular cartilage were investigated. Cartilage samples obtained from bovine patellae were studied during compression at 0.7 MPa (100 psi) for 1 hour. The double quantum filtered spectra showed marked lineshape changes in the compressed samples. Compression did not seem to influence the lineshapes of the single quantum and triple quantum filtered spectra significantly. We found that the residual quadrupolar interaction was reduced in the compressed samples. Changes in the ordering of collagen fibers may be responsible for the observed effect.

Animals

MR identification of white matter abnormalities in multiple sclerosis: a comparison between 1.5 T and 4 T.

BACKGROUND AND PURPOSE: Although MR spectroscopy and functional MR imaging of the brain have been successful at 4 T, conventional fast spin-echo imaging of the brain at 4 T has not been adequately evaluated. The purpose of this study was to compare the detection of white matter abnormalities in multiple sclerosis (MS) at 1.5 T and 4 T. METHODS: Fifteen patients with clinically definite MS were imaged at both 1.5 T and 4 T within a 1-week period. Comparison was made between fast spin-echo long-TR images at both field strengths. Pulse sequences were tailored to maximize resolution and signal-to-noise ratio in clinically relevant imaging times (< 7 min). Four interpreters independently reviewed the images obtained at both field strengths in separate sessions and evaluated them for lesion identification, size, characterization, and subjective resolution. Differences in interpretations at 1.5 T and 4 T were subsequently recorded. RESULTS: Images obtained at 4 T showed a mean of 88 more lesions as compared with images obtained at 1.5 T. All the lesions measured less than 5 mm and were typically aligned along perivascular spaces. Twenty-five consensually identified lesions on 4-T images were not seen at all on 1.5-T images. Moreover, 4-T images showed 56 additional consensually identified lesions, which were indistinct and seen only in retrospect on 1.5-T images. These lesions were frequently (n = 48) identified in large confluent areas of white matter signal intensity abnormality at 1.5 T. All observers also agreed that 4-T images subjectively enhanced the perception of normal perivascular spaces and small perivascular lesions. CONCLUSION: MR imaging at 4 T can depict white matter abnormalities in MS patients not detectable at 1.5 T through higher resolution with comparable signal-to-noise ratio and imaging times.

Adult

Lipid composition changes in normal breast throughout the menstrual cycle.

The detection of breast cancer in women using magnetic resonance imaging (MRI) is increasingly used as a supplement to X-ray mammography. Furthermore, proton MR spectroscopy (1H MRS) has detected alterations in lipid profiles that are linked with tumor development and progression in human biopsy tissue. Because normal "resting" breast is highly active, it is necessary to consider that any alterations observed in lipid profiles may not be indicative of breast tumor development. The purpose of this study was to assess the changes in lipid composition in the breast throughout the menstrual cycle in "normals" using MRS at 4.0 T. Five women with no known history of breast disease were subject to biweekly MRS breast examinations. MRS results showing water and fat resonances revealed cyclic changes in the lipid content throughout the duration of the menstrual cycle. In particular, intensity changes were seen in methylene (-CH2-) and allylic methylene (CH2CH2*CH=) resonances at 2.1 ppm and 1.3 ppm, respectively. These intensity changes assumed a similar cyclic trend for each subject over the 28 days that correlate with the follicular, ovulatory, and luteal phases of the menstrual cycle. The results obtained may indicate cell synthesis or metabolic activity in the breast during the menstrual cycle and provide valuable information pertinent to lipid responses associated with breast disease.

Adult

Fatty tissue on opposed-phase MR images: paradoxical suppression of signal intensity by paramagnetic contrast agents.

PURPOSE: To evaluate paradoxically decreased signal intensity on gadolinium-enhanced opposed-phase magnetic resonance (MR) images of fatty tissues. MATERIALS AND METHODS: Unenhanced and gadolinium-enhanced axial, opposed-phase, gradient-echo images were analyzed visually and with region-of-interest measurements. Tissues measured included adipose tissue (n = 10), angiomyolipomas (n = 8), and vertebral hemangiomas (n = 7). Additionally, a phantom of mayonnaise, soybean oil, agarose, and water (63% lipid signal) with variable concentrations of gadolinium chelate was imaged with similar technique. RESULTS: After administration of gadolinium chelate, signal intensity reduction averaged 18% for adipose tissue, 34% (72-48 units) for predominately fatty angiomyolipomas, and 39% (85-52 units) for vertebral hemangiomas. Imaging of the phantom showed a maximum of 79% reduction in signal intensity with gadolinium chelate (227-47 units). DISCUSSION: Gadolinium-enhanced opposed-phase images depict a significant loss in signal intensity in tissues with MR signal predominately from lipid. Gadolinium chelate increases the signal of water within fatty tissues, which increases the amount of lipid signal suppression due to destructive interference between water and lipid proton magnetizations.

Adipose Tissue

Detection of residual quadrupolar interaction in human skeletal muscle and brain in vivo via multiple quantum filtered sodium NMR spectra.

Using sodium multiple quantum filtered methods, we have, for the first time, demonstrated the presence of residual quadrupolar interaction in human skeletal muscle and brain in vivo. Surface coils were used in both skeletal muscle and brain studies on healthy human volunteers. Theoretical analysis shows that even with arbitrary flip angles the double quantum filter retains filtering capability; it passes even rank two quantum coherence more efficiently than odd rank two quantum coherence. Multiple quantum filtered spectra were obtained from the gastrocnemius muscle in the leg and from the parietal lobe region of the brain. In double quantum filtered spectra, we observed different proportions of narrow and broad components with preparation time, while the line shape of triple quantum filtered spectra remained similar to the one observed in isotropic environment. These results suggest that, in human skeletal muscle and brain, sodium ions are bound to some ordered structures.

Female

Renal perfusion in humans: MR imaging with spin tagging of arterial water.

The authors tested a noninvasive technique for magnetic resonance imaging of perfusion in human kidneys. Magnetic labeling (spin tagging) of aortic arterial water was performed to generate an endogenous tracer. Breath-hold renal perfusion images obtained in seven volunteers yielded average perfusion rates in cortex and medulla of 278 mL.100 g-1.min-1 +/- 55 (standard error) and 55 mL.100 g-1.min-1 +/- 25, respectively.

Humans

Quantitative magnetic resonance imaging of human brain perfusion at 1.5 T using steady-state inversion of arterial water.

We report our experience using a noninvasive magnetic resonance technique for quantitative imaging of human brain perfusion at 1.5 T. This technique uses magnetically inverted arterial water as a freely diffusible blood flow tracer. A perfusion image is calculated from magnetic resonance images acquired with and without arterial blood inversion and from an image of the apparent spin-lattice relaxation time. Single-slice perfusion maps were obtained from nine volunteers with approximately 1 x 2 x 5-mm resolution in an acquisition time of 15 min. Analysis yielded average perfusion rates of 93 +/- 16 ml.100 g-1.min-1 for gray matter, 38 +/- 10 ml.100 g-1.min-1 for white matter, and 52 +/- 8 ml.100 g-1.min-1 for whole brain. Significant changes in perfusion were observed during hyperventilation and breath holding. This technique may be used for quantitative measurement of perfusion in human brain without the risks and expense of methods which use exogenous tracers.

Brain

Metastatic lesions of the brain: imaging with magnetization transfer.

PURPOSE: To study solitary metastatic lesions of the brain with routine spin-echo (SE) and magnetization transfer (MT) magnetic resonance (MR) imaging. MATERIALS AND METHODS: In 15 patients with such lesions, the MT ratio (MTR) was calculated in the center and at the periphery of the metastatic lesion, and distally in adjacent white matter, from the periphery of the lesion radially to the most distant cortex. It also was calculated for mirror-image locations in the opposite hemisphere to provide control values. RESULTS: MTRs were decreased in and immediately around the site of the metastatic focus. MTRs also were lower than control values far distal to the metastatic focus, even when no abnormality was seen on SE MR images obtained before and those obtained after administration of gadopentetate dimeglumine. CONCLUSION: MT enables demonstration of white matter abnormalities in patients with metastatic lesions not seen on SE MR images. These changes can be found in white matter far distal to the lesion and surrounding areas of edema.

Adult

Validation of near-infrared spectroscopy in humans.

Near-infrared (NIR) spectroscopy is a noninvasive technique that uses the differential absorption properties of hemoglobin to evaluate skeletal muscle oxygenation. Oxygenated and deoxygenated hemoglobin absorb light equally at 800 nm, whereas at 760 nm absorption is primarily from deoxygenated hemoglobin. Therefore, monitoring these two wavelengths provides an index of deoxygenation. To investigate whether venous oxygen saturation and absorption between 760 and 800 nm (760-800 nm absorption) are correlated, both were measured during forearm exercise. Significant correlations were observed in all subjects (r = 0.92 +/- 0.07; P < 0.05). The contribution of skin flow to the changes in 760-800 nm absorption was investigated by simultaneous measurement of skin flow by laser flow Doppler and NIR recordings during hot water immersion. Changes in skin flow but not 760-800 nm absorption were noted. Intra-arterial infusions of nitroprusside and norepinephrine were performed to study the effect of alteration of muscle perfusion on 760-800 nm absorption. Limb flow was measured with venous plethysmography. Percent oxygenation increased with nitroprusside and decreased with norepinephrine. Finally, the contribution of myoglobin to the 760-800 nm absorption was assessed by using 1H-magnetic resonance spectroscopy. At peak exercise, percent NIR deoxygenation during exercise was 80 +/- 7%, but only one subject exhibited a small deoxygenated myoglobin signal. In conclusion, 760-800 nm absorption is 1) closely correlated with venous oxygen saturation, 2) minimally affected by skin blood flow, 3) altered by changes in limb perfusion, and 4) primarily derived from deoxygenated hemoglobin and not myoglobin.

Absorption

In vivo magnetic resonance spectroscopy measurement of deoxymyoglobin during exercise in patients with heart failure. Demonstration of abnormal muscle metabolism despite adequate oxygenation.

BACKGROUND: Skeletal muscle metabolic abnormalities have been described in patients with heart failure that are independent of total limb perfusion, histochemical changes, and muscle mass. However, these skeletal muscle metabolic abnormalities may result from tissue hypoxia caused by maldistribution of flow. Myoglobin is an O2 binding protein that can indirectly assess tissue hypoxia. METHODS AND RESULTS: In vivo measurement of deoxymyoglobin was performed by use of proton (1H) magnetic resonance spectroscopy in 16 heart failure (HF) (left ventricular ejection fraction = 20 +/- 6%; VO2 = 14.5 +/- 5.1 mL/kg per minute) and 7 healthy (Nl) subjects. Simultaneous phosphorus (31P) magnetic resonance spectroscopy and near-infrared spectroscopy also were obtained to examine muscle metabolism and oxygenation. Supine calf plantarflexion was performed every 4 seconds. Incremental steady-state work was performed. A second exercise protocol studied rapid incremental (RAMP) exercise with plantarflexion every 2 seconds. Arterial occlusion at end exercise provided physiological calibration for myoglobin and hemoglobin signals. With steady-state exercise, the work slope, ie, inorganic phosphorus to phosphocreatine ratios versus work, was significantly greater in patients with heart failure (Nl: 0.18 +/- 0.08; HF: 0.40 +/- 0.32 W-1; P < .05). Intracellular pH was reduced significantly at end exercise in patients but not healthy subjects. Despite these metabolic abnormalities, muscle oxygenation derived from 760- to 850-nm absorption was comparable in both groups throughout exercise. The relation of inorganic phosphorus/phosphocreatine (P1/PCr) ratio and muscle oxygenation was shifted upward in patients with heart failure such that at the same muscle oxygenation, Pi/PCr ratio in these patients was increased. No deoxymyoglobin signals were observed at rest. At maximal exercise, 4 of the healthy subjects and 3 of the patients exhibited deoxymyoglobin (P = NS). With RAMP exercise, the work slope was again significantly greater in patients with heart failure (Nl: 0.21 +/- 0.10; HF: 0.57 +/- 0.32 W-1; P < .05). Intracellular pH again was significantly decreased at end exercise in patients but not healthy subjects. Five of the healthy subjects and 3 of the heart failure patients had deoxymyoglobin signal (P = NS). With arterial occlusion, deoxymyoglobin was seen in all subjects. CONCLUSION: Abnormal skeletal muscle metabolism in patients with heart failure usually occurs in the absence of myoglobin deoxygenation, suggesting that the abnormalities are not a result of cellular hypoxia during exercise with minimal cardiovascular stress.

Aged

Continuous inversion angiography.

A subtractive time-of-flight technique for magnetic resonance angiography is described. In this approach, the arterial supply to an organ is inverted in a steady-state fashion by applying off-resonance irradiation in the presence of a linear magnetic field gradient. An angiogram is formed by subtracting an image acquired with arterial inversion from a control image acquired with no arterial inversion. A single coil is used to apply both the inversion and observation pulses. Intracranial angiograms obtained from normal volunteers using a two-dimensional projective implementation of this technique at 1.5 T illustrate excellent small vessel detail and background suppression.

Algorithms

Structural determinants of Cys2His2 zinc fingers.

Two mutants of the zinc finger peptide Xfin-31 (Ac-YKCGLCERSFVEKSALSRHQRVHKN-CONH2) containing alterations to the conserved hydrophobic core have been constructed and their zinc-bound structures investigated by 1H NMR techniques. In the first (Xfin-31B) a double mutation R8F/F10G places the conserved core aromatic residue at position 8 rather than position 10. In the second (Xfin-31C), Phe-10 is replaced by Leu. A qualitative analysis of 1H chemical shifts, NOE connectivities and coupling constants indicates that the global folds of both mutants are similar to that of the wild-type protein. However, amide exchange rates suggest that the F10L mutant is much less stable than either the wild-type or the R8F/F10G mutant.

Amino Acid Sequence

Metabolic heterogeneity in human calf muscle during maximal exercise.

Human skeletal muscle is composed of various muscle fiber types. We hypothesized that differences in metabolism between fiber types could be detected noninvasively with 31P nuclear magnetic resonance spectroscopy during maximal exercise. This assumes that during maximal exercise all fiber types are recruited and all vary in the amount of acidosis. The calf muscles of seven subjects were studied. Two different coils were applied: an 11-cm-diameter surface coil and a five-segment meander coil. The meander coil was used to localize the 31P signal to either the medial or the lateral gastrocnemius. Maximal exercise, consisting of rapid plantar flexions, resulted in an 83.7% +/- 7.8% decrease of the phosphocreatine pool and an 8-fold increase of the inorganic phosphate (Pi) pool. At rest the Pi pool was observed as a single resonance (pH 7.0). Toward the end of the first minute of exercise, three subjects showed three distinct Pi peaks. During the second minute of exercise the pH values stabilized at 7.12 +/- 0.12, 6.63 +/- 0.15, and 6.27 +/- 0.23. The same pattern was seen when the signal was collected from the medial or lateral gastrocnemius. In four subjects only two distinct Pi peaks were observed. The Pi peaks had differing relative areas in different subjects, but they were reproducible in each individual. This method allowed us to study the appearance and disappearance of the different Pi peaks, together with the changes in pH. Because multiple Pi peaks were seen in single muscles they most likely identify different muscle fiber types.

Adenine Nucleotides

The use of finite impulse response filters in pulse design.

We develop a new way of synthesizing pulse sequences with desirable frequency characteristics. By combining our previous results with techniques from the theory of finite impulse response filters, we can specify (1) the total duration of the pulse sequence, (2) the frequency ranges it is desired to perturb, (3) the desired perturbation, and (4) the frequency range it is desired not to perturb. We can then synthesize a hard pulse sequence which will yield that desired perturbation with the minimal possible error. The minimum error is global, in the sense that no pulse sequence can do better at achieving the specifications, and is not just a local minimum, around the pulse sequences close to the derived pulse.

Algorithms