Crowns, veneers, and temporaries: restoring a porcelain damaged dentition.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to L Berland.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The purpose of this study was twofold: (1) to develop multiple regression equations for predicting computed tomography (CT) derived intra-abdominal (IAF), subcutaneous (SCF), and total (TOTF= IAF+SCF) abdominal adipose tissue areas from anthropometric measures in adult white males with a large range of age (18-71 years) and percent body fat (2.0-40.6); and (2) to validate the new and existing equations that used similar Hounsfield Units (HU) for determining IAF for estimating these fat depots. One hundred fifty-one white male subjects had IAF, SCF, and TOTF determined by a single CT scan, skinfold and circumference measures taken and body density determined. Linear intra-correlations and factor analysis procedures were used to identify variables for inclusion in stepwise multiple regression solutions. IAF was estimated from age, waist circumference, the sum of mid-thigh and lower thigh circumferences, and vertical abdominal skinfold. SCF was estimated from age, umbilicus circumference, chest and suprailiac skinfolds. TOTF was estimated from age, body mass index (BMI), chest skinfold, and umbilicus circumference. R2 for IAF, SCF, and TOTF was .73, .77, and .86 respectively. The existing and the new equations were validated on an independent sub-sample of 51 subjects. The only existing equation that met validation criteria had a validation R2 = .67 for IAF. All three new equations met validation criteria with R2 validations of .75, .79, and .85 for IAF, SCF, and TOTF respectively. It is concluded that the new equations might be used as an inexpensive estimation of IAF, SCF, and TOTF in adult white males varying greatly in age and percent body fat.
Central fat distribution and more recently intra-abdominal adipose tissue (IAF) have been associated with elevated cardiovascular risk factors (CRF). Despite increased interest in use of LAF for screening for CRF, interpretation of risk found in a specific IAF is difficult since regressions for estimating CRF from IAF have not been published. The purpose of this paper is to report IAF values that are likely to be associated with elevated CRF. One hundred forty-six healthy male subjects 30-71 years were evaluated for IAF and subcutaneous fat (computed tomography scan at 4th lumbar vertebra), height, body weight, % fat, various anthropometric measures, blood cholesterol (CHOL), HDL cholesterol (HDL), systolic blood pressure (SBP), and diastolic blood pressure (DBP). Receiver-Operating-Characteristic curves (ROC) were used to develop IAF cutpoints associated with elevation of at least one established CRF criteria (CHOL=200, HDL=<35, SBP=140, DBP=90). A sensitivity/(1- specificity) curve established the value of using IAF cutpoints for detecting elevated CRF. Likelihood ratios were used to identify optimal cutpoints. Two cutpoints were identified, 131 cm2 with a relatively high Lpos ratio and 71 cm2 with a relatively low Lneg. False positives associated with 131 cm2 were 14% for one or more elevated CRF. False negatives associated with 71 cm2 were 9% for one or more elevated CRF, 4% for two or more CRF, and 0% for three or more elevated CRF. This study clearly indicates that IAF above 131 cm2 is related to elevated CRF and IAF below 71 cm2 is associated with reduced cardiovascular risk.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Femoral artery pseudoaneurysm formation is a significant problem in patients undergoing cardiac catheterization and interventional cardiac procedures. It is especially more common with the use of anticoagulant and antiplatelet therapy and the use of intracoronary stents. We describe our initial experience with clinically guided bedside compression of femoral pseudoaneurysms in such patients. Eleven patients, 10 undergoing coronary angioplasty (including 3 with intracoronary stents) and 1 undergoing diagnostic cardiac catheterization, developed a femoral pseudoaneurysm. All patients had a femoral bruit and 9 had an expansile groin hematoma. The diagnosis was confirmed in each case by Doppler ultrasound. Seven patients were receiving heparin while 4 were on oral anticoagulants at the time of detection of the pseudoaneurysm. These patients underwent clinically guided graded external compression to close the pseudoaneurysm neck while maintaining femoral arterial flow. External compression for 104.1 +/- 63 min resulted in successful clinical resolution of pseudoaneurysm in all patients without complications. The results were confirmed by Doppler ultrasound at least 12 hr later. Bedside compression of femoral pseudoaneurysms guided by clinical clues is simple and appears to be an effective and safe technique to manage this iatrogenic problem.
Treatment planning for dental implants presents special challenges to the dentist. The authors review the conventional radiographic and non-radiographic methods for the assessment of the implant site. A new dental interactive treatment planning program under development at the University of Alabama School of Dentistry Department of Periodontics is described.
Explore the source record for details and available documents.