Search PubMed⌕ Search

Biomedical subjects

L B Liem

Publications and source records attributed to L B Liem.

43 records · Page 3Linked to original sources

Pharmacodynamics of procainamide in patients with ventricular tachyarrhythmias.

The onset and offset of the electropharmacologic effect of procainamide was studied in nine patients with ventricular arrhythmias. Procainamide was given at a constant infusion rate of 0.27 +/- 0.05 mg/kg/min for 50 to 60 minutes to an average total dose of 15.5 +/- 4.4 mg/kg. The QRS interval (used as an index of electropharmacologic effect) at a paced cycle length of 500 ms, and the plasma procainamide concentration were measured simultaneously every 5 minutes during infusion and at frequent intervals for up to 4 hours during a washout period. The average peak plasma concentration was 15.8 +/- 9.6 micrograms/ml and the average maximum QRS interval prolongation was 23.9 +/- 6.8% from baseline. The temporal and static plasma concentration-effect relationships were evaluated by pharmacodynamic modeling and linear regression. For six patients, there was a minimal (less than 2 minutes) delay in the plasma concentration-effect relationship, and the data fit a linear relationship with an average slope of 3.2 +/- 1.1 msec/microgram/ml. For the other three patients, there was a significant delay (3, 10, and 18 minutes respectively) in the plasma concentration-effect relationship. In most patients, the electropharmacologic effect of procainamide is rapid and proportional to plasma concentration; but in a minority of patients, significant delay occurs and could influence the results and interpretation of electropharmacologic studies.

Adult↗

Pacing hazards in helicopter aeromedical transport.

A 62-year-old man with third-degree atrioventricular block and hemodynamically unstable ventricular tachycardia had a cardiac arrest during helicopter transport to a specialized cardiac care unit. Before transport, his ventricular tachycardia had been successfully terminated by a rapid overdrive pacing technique. The failure of "burst suppression" and the absence of pacer spike artifact on the electrocardiographic monitor raise questions about the potential hazards of using various pacing techniques during helicopter transports. Most significantly, this case points to the possibility of interference by exogenous electromagnetic signals in the medical compartment of the helicopter.

Aircraft↗

Cycle length dependence of human action potential duration in vivo. Effects of single extrastimuli, sudden sustained rate acceleration and deceleration, and different steady-state frequencies.

Using a new method for long-term recording of monophasic action potentials from the human heart, we studied in 17 patients the effects on ventricular action potential duration (APD) of three clinically pertinent cycle length perturbations: (1) single extrastimuli, (2) abrupt sustained rate acceleration and deceleration, and (3) different steady-state cycle lengths. Results were: (a) APD after single extrastimuli at progressively longer cycle lengths were related to the extrastimulus cycle length with a biphasic electrical restitution curve which after an initial steep rise and a subsequent transient descent rose again more gradually to a plateau at cycle lengths above 800-1,000 ms. (b) After a sustained step decrease in cycle length, the first APD shortened abruptly while final steady-state adaptation required up to several minutes. The transition between the rapid and slow phase of APD change was characterized by a variable alternans of APD which correlated inversely with the preceding diastolic interval. (c) In the steady state, APD correlated linearly with cycle length, increasing an average of 23 ms per 100 ms cycle length increase (r = 0.995). The divergence between steady-state and non-steady-state APD, and the slowness of steady-state adaptation, are important factors to be considered in clinical electrophysiologic studies and in rate correction algorithms of APD or QT intervals, respectively.

Action Potentials↗

Electropharmacology of flestolol for supraventricular tachycardia without associated structural heart disease.

Flestolol is an ultrashort-acting beta-blocking drug with a half-life of 6.9 minutes. Its antiarrhythmic efficacy was studied in 21 patients with spontaneous and inducible supraventricular tachycardia: atrioventricular (AV) nodal tachycardia in 6 patients and orthodromic AV reciprocating tachycardia in 15. It increased the effective refractory period of the AV node in all patients with AV nodal tachycardia (fast pathway, p less than 0.02; slow pathway, p less than 0.01), but did not alter the anterograde (n = 8) or retrograde (n = 9) refractory periods of accessory pathways. Flestolol prevented initiation of tachycardia by causing block in anterograde AV nodal conduction. It was more effective in patients with AV nodal tachycardia (5 of 6) than in those with AV reciprocating tachycardia (4 of 15, p less than 0.03). In patients in whom it was ineffective, the mean tachycardia cycle length increased by 54 ms because of an increase in AH interval (p less than 0.0001, n = 11). The cycle length of tachycardia induced 30 minutes after infusion was similar to the cycle length in the control state (354 vs 355 ms, n = 16). Flestolol's kinetics permitted clinically indicated electropharmacologic testing of a second antiarrhythmic drug in 8 patients and control of ventricular rate until arrhythmia surgery in 1 patient with incessant tachycardia. No hypotension or toxicity occurred. Our findings indicate that flestolol's principal antiarrhythmic effects are on the AV node, similar to the effects of other beta-blocking drugs. Its ultrashort duration of action is an advantage during electropharmacologic testing.

Adrenergic beta-Antagonists↗

Electrophysiology and antiarrhythmic efficacy of intravenous pirmenol in patients with sustained ventricular tachyarrhythmias.

We assessed the electrophysiologic effects and antiarrhythmic efficacy of intravenous pirmenol in 15 patients who had spontaneous and induced sustained ventricular tachyarrhythmias. At a plasma concentration of 2.29 +/- 0.75 micrograms/ml, pirmenol decreased sinus cycle length by 11 +/- 13%, increased QRS, QTc, and HV intervals by 14 +/- 12%, 13 +/- 12%, and 22 +/- 28%, respectively, and increased atrial and ventricular effective refractory periods (ERP) by 20 +/- 14% and 7 +/- 8%, respectively. There was a greater increase in QRS duration during ventricular tachycardia and ventricular pacing than during sinus rhythm (p less than 0.005). By electropharmacologic testing, pirmenol was judged effective in six patients (40%) and was proarrhythmic in one (6%). In the nine patients in whom pirmenol was judged ineffective, the cycle length of induced VT increased by 36 +/- 15% and the associated mean arterial pressure increased by 21 +/- 14 mm Hg. The only side effects were mild hypotension and mild nausea in one patient each. Intravenous pirmenol has type IA electrophysiologic effects. It can be administered safely to patients with sustained ventricular tachyarrhythmias and is as effective as approved antiarrhythmic drugs when assessed by electropharmacologic testing.

Adult↗

Summation and inhibition by ultrarapid train pacing in the human ventricle.

Trains of ultrarapid stimuli that begin late in the refractory period have been reported both to produce early single captures to terminate tachyarrhythmias and to inhibit the response to subsequent threshold stimuli. To determine which characteristics of trains facilitate capture and which enhance inhibition, we compared the right ventricular strength interval relationship for single extrastimuli (S2) with that for 100 Hz trains with a duration of 100 msec in 29 patients. Pulse frequency was varied in 12 patients (50, 100, and 200 Hz) and train duration (50, 100, and 150 msec) was varied in 11 patients; the effect of procainamide (10.1 +/- 2.3 micrograms/ml) was assessed in 10 patients. Relative to S2, 100 Hz trains with a duration of 100 msec prolonged the effective refractory period (ERP) at low current strength (inhibition), but shortened the ERP at high-current strength (summation): at 0.5 mA, the train ERP was 47 +/- 6 (SEM) msec longer than the S2 ERP (p less than .001); at 16 mA it was 12 +/- 1 msec shorter (p less than .001). Trains prolonged the functional refractory period (FRP) slightly at low currents (13 +/- 3 msec, p = .001 at .05 mA), but did not shorten FRP significantly at high currents (2 +/- 2 msec, p = NS at 16 mA) because of increased stimulus-response latency. Inhibition increased with increasing pulse frequency (p less than .001), increasing train duration (p less than .001), and procainamide (p less than .01). Summation increased with increasing pulse frequency (p less than .001), but not increasing train duration or procainamide, suggesting that inhibition and summation depend on different electrophysiologic mechanisms.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Effects of high stimulation current on the induction of ventricular tachycardia.

Programmed stimulation at 2 right ventricular sites with 1 to 3 extrastimuli was performed at current strengths of twice diastolic threshold (1.0 +/- 0.2 mA, mean +/- standard deviation) and 10 mA in 41 patients undergoing an electrophysiologic study because of sustained ventricular tachycardia (VT) (11 patients), nonsustained VT (19 patients) or unexplained syncope (11 patients). In 26 patients, VT was not induced by programmed stimulation at twice diastolic threshold. Programmed stimulation at 10 mA induced VT or ventricular fibrillation in 16 of these 26 patients (62%). In 4 of 16 patients, the coupling intervals of the extrastimuli that induced VT/ventricular fibrillation at 10 mA were all equal to or longer than the shortest coupling intervals resulting in ventricular capture at twice diastolic threshold. Fifteen patients had inducible VT at twice diastolic threshold. Programmed stimulation at 10 mA induced a similar VT in 12 of these patients, but resulted in no VT induction in 3 of 15 patients (20%), despite ventricular capture at the same coupling intervals that had induced VT at twice diastolic threshold. This study shows that programmed stimulation at a high current strength may either facilitate or prevent induction of VT. Facilitation of VT induction usually is attributable to a shortening of ventricular refractoriness and the ability of extrastimuli at 10 mA to capture the ventricle at shorter coupling intervals than possible at twice diastolic threshold. However, in 25% of cases, the facilitation of VT induction by 10-mA stimuli is not explained by a shortening of ventricular refractoriness.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗