Search PubMed⌕ Search

Biomedical subjects

L B Bell

Publications and source records attributed to L B Bell.

22 records · Page 2Linked to original sources

Technique for continuous measurement of compliance in isolated vascular segments.

A method has been developed that provides an on-line (1/s) measurement of elastance [E = 1/compliance (C)] in a perfused isolated vessel segment in situ. Values of E can be obtained as a function of perfusion pressure (P) or in response to drug interventions. Noncompliant stainless steel tubes are used as inflow and outflow cannulas. Segment P is obtained from a short small-bore stainless steel catheter and miniature pressure transducer. During constant flow through the inflow cannula, an adjustable outflow resistance is used to set the segment P. Simultaneous activation of solenoid pinch valves, for 200 ms, compresses in-line Silastic tubing next to each cannula and serves to simultaneously 1) isolate the segment and 2) inject a small volume into the segment (delta V). This delta V results in a step increase in segment P (delta P). delta V is not significantly altered by changing the volume of air in the in-line windkessel reservoir (when air volume is greater than or equal to 100 ml), mean perfusion pressure (over a range of 50-150 mmHg) or compliance of the test cell. Therefore, delta P alpha E, and 1/delta P alpha C. Since this recorded variable is linearly related to C, actual C can be continuously recorded on a recorder after a simple two-point calibration process. C as determined by this method was found to be linearly related (r = 0.997) to calculated C of a test cell air bubble (range: 0.1 less than C less than 0.7 microliter/mmHg; resolution: 0.001 microliter/mmHg).(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Mechanical effects of vasoactive drugs on carotid sinus.

Carotid sinus diameter (CSD) is influenced by changes in sympathetic tone and vasoactive agents. This study was designed to determine which mechanical properties of the carotid sinus region were influenced by infusing vasoconstrictors (epinephrine, 4.56 X 10(-6) M, and phenylephrine, 9.85 X 10(-5) M) and a vasodilator (nitroprusside, 1.68 X 10(-4) M). CSD, carotid sinus length (CSL), pressure (CSP), and compliance (CSC), and arterial pressure were all recorded simultaneously from the isolated constant-flow-perfused carotid sinus region of 11 anesthetized dogs (35 mg/kg pentobarbital sodium) before and after drug perfusion. CSC was measured by a method previously described in which 13 microliters of perfusate is injected into the segment in a step-like manner and the resultant step change in pressure recorded. The compliance of the vessel segment is read on-line after a calibration procedure. CSD and CSL were measured using sonomicrometer length gauges positioned across and along the length of the carotid sinus segment. At a CSP of 99.9 +/- 0.6 (SE) mmHg, CSD, CSL, and CSC were 8.50 +/- 0.44 mm, 9.44 +/- 0.84 mm, and 0.46 +/- 0.05 microliter/mmHg, respectively. Decreasing CSP to 50 mmHg significantly reduced CSD and CSL and increased CSC. Increasing CSP to 150 mmHg produced opposite results. Vasoconstrictor drug infusion significantly decreased and vasodilator drug infusion significantly increased both CSD and CSL, producing parallel shifts in the CSP-CSD and -CSL curves toward and away from the pressure axis. The shift to new pressure-volume curves resulted in no change in CSC in response to the vasoactive agents.

Animals↗