Search PubMed⌕ Search

Biomedical subjects

L Ambrosio

Publications and source records attributed to L Ambrosio.

At least 55 records · Page 3Linked to original sources

Viscoelastic behavior of composite ligament prostheses.

Despite the compelling need for artificial connective tissue replacements for orthopedic applications, to date, there is no material which can adequately reproduce the mechanical behavior of natural tissue with necessary long-term endurance. In this work, we introduce a novel soft composite material as a more suitable candidate for connective tissue replacement. The material proposed is based on a hydrogel-polymer matrix reinforced with poly(ethylene terephthalate) fibers wound helically to mimic the architecture of the collagen fibers in natural tissue. Macroscopic behaviors such as static stress-strain, stress relaxation, and dynamic frequency responses can be modulated with choice of the components and design of the composite structure. In doing so, the mechanical characteristics of natural ligaments can be qualitatively reproduced and sustained over time.

Composite Resins↗

Isothermal and non-isothermal polymerization of a new bone cement.

A new bone cement based on poly(ethylmethacrylate) (PEMA), hydroxyapatite powder (HA) and n-butylmethacrylate monomer (n-BMA) has been studied using isothermal and non-isothermal polymerization. Methacrylate monomers are highly reactive and release a considerable amount of heat during polymerization. A quantitative understanding of the methacrylate polymerization is necessary because the thermal history of the polymerization has considerable influence on the final properties of a bone cement. In the first part, polymerization kinetics are analysed by means of differential scanning calorimetry (DSC). DSC data are used to evaluate a phenomenological model describing the cure kinetics of this new bone cement. In the second part, a kinetic model coupled with the energy balance is used to obtain temperature and degree of conversion profiles in the bone-cement-prosthesis system, under non-isothermal conditions, as function of initial temperature and thickness of the cement. Material properties, boundary and initial conditions and the kinetic behaviour are the input data for the numerically solved heat-transfer model. The temperature at the bone/cement interface, can be considered as a weak point, often responsible for total joint replacement failure. For this particular bone cement exhibiting a low exotherm and low glass transition temperature, the interfacial temperature is lower than the threshold level for thermal tissue damage (50 degrees C). The conversion occurs almost completely, avoiding problems with unreacted monomers that can be released by the cement, giving rise to tissue damage.

Journal Article↗

Comparison between the polymerization behavior of a new bone cement and a commercial one: modeling and in vitro analysis.

The polymerization behavior of a new bone cement based on poly(ethylmethacrylate), hydroxyapatite powder and n-butylmethacrylate monomer and a commercial cement have been studied. Polymerization kinetics were analyzed by means of differential scanning calorimetry (DSC). DSC data have been used to evaluate a phenomenological model describing the cure kinetics of this new bone cement. The kinetic model coupled with the energy balance was then used to obtain temperature and degree of conversion profiles in the bone-cement-prosthesis system, under non-isothermal conditions, as function of initial temperature and thickness of the cement. Material properties, boundary and initial conditions and the kinetic behavior were the input data for the numerically solved heat-transfer model. The modeling results have been compared with in vitro results.

Journal Article↗

Composite hydrogels for implants.

Hydrophilic composite structures are designed to mimic the transport and mechanical properties of natural soft tissue such as tendons, ligaments and intervertebral discs. Mechanical and viscoelastic behaviour of a soft composite material based on a hydrogel matrix reinforced with bundles of polyethylene therephthalate (PET) fibres is analysed. The typical J-shaped stress-strain behaviour, displayed by natural tendons and ligaments, is reproduced. The mechanical characteristics, such as the extent of the 'toe-in region' and the elastic modulus in the linear region, can be controlled by varying the winding angle of the fibres and the matrix composition. Dynamic mechanical analysis showed the dual behaviour of the composite systems due to the progressive contribution of the PET fibres. Different poly(2-hydroxyethylmethacrylate)/polycaprolactone (PHEMA/PCL) semi-interpenetrating polymer networks (IPNs) hydrogel composite systems reinforced with PET fibres have been investigated for potential use as intervertebral disc prostheses. Compression properties have been evaluated by static and dynamic tests. Uniaxial compression tests on the swollen samples showed an increase of the modulus and maximum stress with increasing content of PCL and PET fibres. Creep behaviour is also dependent on the hydrogel composition. The composite PHEMA/PCL hydrogels showed compression properties similar to those expressed by canine intervertebral discs in different spinal locations.

Animals↗

The differential effects of poly(2-hydroxyethyl methacrylate) and poly(2-hydroxyethyl methacrylate)/poly(caprolactone) polymers on cell proliferation and collagen synthesis by human lung fibroblasts.

Because of its chemical versatility and demonstrated biocompatibility, poly(2-hydroxyethyl methacrylate) (pHEMA) has been widely used as a polymer for biomedical applications. Since this hydrophilic material shows a poor interface with cells, blendings with other polymers were done to improve cytocompatibility. In our polymer, the presence of hydrophobic dominions on the material surface, due to the interpenetrating polymerization of pHEMA with poly(caprolactone) (PCL), seems to ameliorate the cytocompatibility in terms of cell adhesion and metabolism. For our experiments, we used IMR-90 human fibroblasts, as these cells strongly regulate DNA, RNA, and protein synthesis as anchorage-dependent variables. Cell attachment on a pHEMA/PCL interpenetrating polymer network was optimal, suggesting a strong adhesion between the cells and the polymer surface. Cell adhesion was weaker on pHEMA, as a significant fraction of the fibroblasts revealed a lack of spreading, with most cells remaining spherical. Moreover, only fibroblasts seeded on pHEMA significantly decreased mRNA synthesis; collagen production and cell shapes ranged from fully flat and proliferating, to minimally spread and nonproliferating. Finally, DNA synthesis, as a measure of cell proliferation, was markedly inhibited in cells cultured on pHEMA but not on pHEMA/PCL. In conclusion, our results suggest that control of cell growth and metabolism by biomedical polymers is based on physicochemical mechanism(s) in which the hydrophilicity/hydrophobicity ratio of the material surfaces may play an important role.

Base Sequence↗

Characterization of maternal and zygotic D-raf proteins: dominant negative effects on Torso signal transduction.

The maternal D-raf serine/threonine kinase acts downstream of Torso (Tor) for specification of cell fates at the embryonic termini. D-raf activity is also required in other signal transduction pathways and consistent with its pleiotropic role, we find accumulation of a 90-kD D-raf protein throughout embryonic development. We also characterize the accumulation of maternal D-raf proteins in 0-2-hr embryos derived from females with germ cells lacking D-raf activity. Accumulation of a 90-kD or truncated mutant D-raf protein is observed for some of these embryos, while others lack the maternal D-raf protein. Then to determine whether rescue of the Tor pathway is influenced by pools of nonfunctional maternal D raf. wild-type D-raf mRNA was injected into embryos that inherit maternal stores of inactive 90-kD of truncated D-raf protein. For embryos lacking the maternal D-raf protein, a high level of terminal rescue is obtained. In contrast, rescue is reduced or not observed for embryos that accumulate mutant maternal D-raf proteins. These findings suggest that mutant forms of D-raf may deplete the embryo of a positive activator and/or form inactive protein complexes that affect rescue of the Tor pathway.

Animals↗

Comparison between in vitro and in vivo UHMW-PE degradation.

There is an increasing interest in orthopedics for clinical problems associated with wear and failure of ultra-high-molecular-weight (UHMW) polyethylene devices. Wear not only affects the implant performance but, more importantly, produces the release of particulate debris in the surrounding tissues and fluids. The debris in turn cause a deleterious biological response that can include an inflammatory reaction with subsequent loosening of the implant components. Surface wear is certainly promoted from the oxidation process that can occur during the prosthesis life. However, the oxidation mechanism involved during the implantation period has not been described yet for the UHMW-polyethylene devices. Here, the comparison of FT-IR spectra of a retrieved acetabular cup (9 years in a human body) and thin UHMW-PE films treated respectively with: H2O2, KO2/THF, and Fe[II]/H2O2 solutions indicates the effect of the high reactive hydroxyl radicals as the most important cause of in vivo polymer degradation.

Biocompatible Materials↗

The activity of D-raf in torso signal transduction is altered by serine substitution, N-terminal deletion, and membrane targeting.

The Raf family of serine/threonine kinases are essential components in many receptor tyrosine kinase-mediated signal transduction pathways. Here, we analyze the function of D-raf in the Torso (Tor) pathway required to specify cellular fates at the embryonic poles. Using mutant embryos lacking endogenous D-raf protein, we show that D-raf's serine/threonine kinase activity is essential for its role in Tor signal transduction and that human Raf-1 will substitute for D-raf in this pathway. After Tor activation, D-raf becomes hyperphosphorylated. We identified two putative serine phosphorylation sites (S388 and S743) in SF9 cells and demonstrate that S743 or its phosphorylation is essential for D-raf function in embryos. Alanine substitution at S388, N-terminal truncation, or targeted membrane association permits transmission of the Torso signal by D-raf, but these D-raf molecules differ in their rescuing potential and relative biological activity. Membrane-targeted D-raftor4021 showed the highest level of activity, followed by alanine-substituted D-rafS388A and N-terminal-truncated D-raf delta 445. Since the activity profiles for these altered forms of D-raf are distinct, these findings indicate that each structural modification differentially affects the regulation and/or propagation of the Tor signal by these mutant D-raf proteins.

Alanine↗

Synthesis and characterization of a new interpenetrated poly(2-hydroxyethylmethacrylate)-gelatin composite polymer.

Poly(2-hydroxyethylmethacrylate) [poly(HEMA)] is a widely used biomaterial which does not allow cell adhesion and growth on its surface, limiting its use in biomedical applications in which cell cohesion is detrimental. We have prepared a poly(HEMA)-gelatin composite hydrogel using a sequential interpenetrating polymer network technique. The properties of this material were compared with poly(HEMA) freeze-dried sponges in terms of morphology, mechanical properties and biocompatibility. Moreover, in vivo biocompatibility experiments highlighted the occurrence of cellular interactions on the surface of the poly(HEMA)-gelatin interpenetrating polymer network, which are usually absent when unmodified poly(HEMA) hydrogels are implanted in the same host organism. These tests also showed a progressive gelatin degradation from the surface to the bulk of the poly(HEMA)-gelatin specimens during short-term (7 d) implantation. Finally, in vitro tests confirmed an improved ability of this composite to scaffold for the cells.

3T3 Cells↗

Imaging and manipulating chromosomes with the atomic force microscope.

Polytene chromosomes from the salivary gland cells of Drosophila melanogaster were examined by atomic force microscopy. The atomic force microscope (AFM) was capable of resolving chromosomal features down to the limits of the tip sharpness, about 500 A for pyramidal-shaped tips. Resolution was increased to 300 A by using electron beam deposited (EBD) tips with high aspect ratios. This significantly exceeds the resolution obtainable with conventional optical microscopes, but at the cost of compromising the structural integrity of the sample. A reasonable compromise was achieved by using oxide-sharpened tips. In this case high resolution was obtained without sample degradation, but when desired these tips were also capable of sample disintegration with increased scanning force and rate. Thus, oxide-sharpened tips were used to precisely dissect defined chromosomal regions to illustrate their potential use in genetic mapping efforts. This study illustrates the utility of the AFM in the characterization and manipulation of chromosomes and chromosomal DNA.

Animals↗

Mechanical behaviour of composite artificial tendons and ligaments.

The mechanical behaviour of a soft composite material based on a hydrogel polymer matrix reinforced with bundles of poly(ethylene terephthalate) (PET) fibres is analysed. The composite reproduces the typical J-shaped stress-strain curves displayed by natural tendons and ligaments. The lamination composite theory was used to investigate the role of the fibres and the matrix properties, as well as the role of the winding angle and the volumetric fraction of fibres, on the mechanical response of this system. The results suggested that large variations in the mechanical behaviour can be obtained by changing the winding angle of the fibres in the composite which determines the extent of the 'toe' region and the sensitivity of the system to the rigidity of the fibres.

Animals↗

Combining optical and atomic force microscopy for life sciences research.

The atomic force microscope (AFM), a three-dimensional imaging tool that can measure structures from the atomic level to micron scale, has been combined with an inverted optical microscope capable of confocal imaging. The robust design of this microscope, termed the BioScope, enables the operator to use fluorescent markers on a wide variety of biological specimens to determine internal structure to 200 nm resolution and determine surface morphology of the same sample to 20 nm resolution while imaging under physiological conditions. In this report we demonstrate the capabilities of the BioScope by examining living Xenopus retinal glial (XR1) cells, Drosophila polytene chromosomes and colloidal gold-labeled plasmid DNA.

Animals↗

In vivo induction of macrophage Ia antigen (MHC class II) expression by biomedical polymers in the cage implant system.

Examination of the cellular components in the inflammatory exudate, which infiltrates subcutaneous cages, can be used to monitor the progress of an inflammatory response to an implanted material. Of particular interest is the study of monocyte/macrophage infiltration into the implanted cages containing biomaterials, as macrophages may initiate a wide spectrum of responses upon interaction with a foreign material. In this study, the authors propose a technique using subcutaneous tissue cages in conjunction with cytofluorimetric analysis of exudate leukocytes to evaluate the monocyte/macrophage cell activation in response to different materials. The studies reported here used several materials (thermoplastic and elastomeric polymers) as the challenging agent, to demonstrate whether polymers, chemically different from each other, could differentially activate macrophages to carry out their proinflammatory role more effectively. The materials tested included: poly(etherurethane ureas) (PEUU A'), poly(etherurethane ureas) with a surface active additive, Methacrol, (PEUU C'), polymethylsiloxane (PDMS), polyetherimide, (PEI), and polyetheretherketone, (PEEK). For all tested materials, the maximum numbers of exudate cells and of Ia-positive macrophages were found on day 7, although the entity of the cell increase was associated with the material used for the implant. Similarly, the percentage of Ia-positive macrophages varied according to the specific polymer present in the cages after 7 days. By day 14, the percentage of Ia-positive macrophages decreased with individual exudates showing 19-32% Ia-positive cells depending on the different type of material. Only in the case of PDMS did the percentage of Ia-positive macrophages remain the same as compared with control empty cage macrophages.

Animals↗

Chitosan-mediated stimulation of macrophage function.

According to the modern definition of biocompatibility, a biocompatible material need not be inert but be bioactive. A benign reactivity implies that the reactivity has to be appropriate for the intended use. Chitosan, a non-acetylated or partially deacetylated chitin (a linear homopolymer of beta (1-4)-linked N-acetylglucosamine) has been proposed as a biomaterial because of its apparent satisfactory biocompatibility. The present investigation demonstrates that chitosan has an in vitro stimulatory effect on both macrophage nitric oxide (NO) production and chemotaxis. The macrophage NO secretion is attributed to the N-acetylglucosamine unit of the chitosan molecule rather than to the glucosamine residue (28 and 15 microM NO respectively). Moreover, the immune stimulatory effect of chitosan was very specific since other glycosaminoglycans, such as N-acetyl-D-mannosamine and N-acetyl-D-galactosamine, had no effects on NO production (5 and 8 respectively). In vivo experiments strengthen this hypothesis. Transmission electron microscopy analysis identifies the presence of many leucocytes in the specimens after 14 d post-implantation, showing poor healing processes (i.e. fibroblast proliferation and collagen deposition) that characterize the tissue repair at this time in our animal model.

Acetylglucosamine↗

Hydrogels as an interface between bone and an implant.

The use of fully hydrated hydrogels in the body has been well established. The forces a hydrogel generates on swelling when it is placed in a constrained space were investigated with a view to providing a mechanism for fixing a prosthesis in the intramedullary cavity. A cross-linked poly(2-hydroxyethyl methacrylate) [p(HEMA)] hydrogel was investigated as a potential material. In vitro mechanical tests were carried out to determine the stresses generated in the p(HEMA) when it was placed in water and not allowed to swell. Pull out loads of up to 375 N indicated that the system could be used successfully in vivo. Consequently, the material was placed intraosseously at two sites in a rabbit animal model, in the mid-shaft (diaphysis) and the lower end (metaphysis) of the femur. Histological examination showed there was no adverse bone response; bone was growing from the endosteal surface up to and into the hydrogel in the diaphyseal implants and surrounded the hydrogel in the metaphysis. As a result of the shape and size variations in the rabbit femur, in vivo mechanical tests were found to give lower values than those obtained in vitro.

Animals↗

Comparative biological tests on segmented polyurethanes for cardio-vascular applications.

In order to select a candidate segmented polyurethane (SPU) elastomer for the preparation of cardio-vascular prostheses, a series of biological tests (namely haemolysis, aPTT and PT coagulation tests, cytotoxicity, human endothelial cells seeding) was carried out on five commercially available biomedical polyurethanes. The tests were performed on solvent cast samples, from THF (Cardiothane 51, Pellethane 2363 80A, Estane 5714 F1, and Estane 58810), or DMAC (Biomer). All the materials were sterilized by gamma-irradiation before being tested. From the results obtained all the polyurethanes used in this study were shown to be devoid of toxicity towards blood (as proved by haemolysis and coagulation time tests) or blood cells (as proved by cytotoxicity and cell adhesion assays). A clear difference among the tested copolymers didn't stand out under our test conditions, although Cardiothane, possibly due to its physico-chemical characteristics, was less effective in promoting endothelial cell adhesion.

Animals↗

Developmental and molecular characterization of mutations in the Drosophila-raf serine/threonine protein kinase.

Formation of the tail region of the Drosophila larva requires the activities of the terminal class genes. Genetic and molecular analyses of these genes suggests that localized activation of the receptor tyrosine kinase torso at the posterior egg pole triggers a signal transduction pathway. This pathway, mediated through the serine/threonine protein kinase D-raf and the protein tyrosine phosphatase corkscrew, controls the domains of expression of the transcription factors tailless and huckebein. In this paper, we report the molecular and developmental characterization of mutations in the D-raf gene. We show that mutations that alter conserved residues known to be necessary for kinase activity are associated with a null phenotype, demonstrating that D-raf kinase activity is required for its role in torso signaling. Another mutation, D-rafPB26, which prematurely truncates the kinase domain shows a weaker maternal effect phenotype that is strikingly similar to the corkscrew maternal effect phenotype, suggesting that a lower amount of kinase activity decreases the terminal signaling pathway. Finally, molecular and developmental characterization of two mutations that affect the late D-raf zygotic function(s) implies a novel role for D-raf in cell fate establishment in the eye. One of these mutations, D-rafC110, is associated with a single amino acid change within the putative D-raf regulatory region, while the other, D-rafHM-7, most likely reduces the wild-type amount of D-raf protein.

Amino Acid Sequence↗