[Stimulation by automatic scanning in the long-term treatment of hyperkinetic arrhythmias (author's transl)].

The use of programmed stimulation in the long-term treatment of re-entry tachycardia offers encouraging perspectives. Among the others proposed the "scanning" system seems to be the most effective. However, an implantable stimulator with such pictures is not yet available and a temporary electrode is thus required. These difficulties have been overcome utilizing the radiofrequency as a sincronizing and stimuli-producing means. An implantable appliance was therefore designed which is triggered by the patient himself and automatically researches the zone of interruption of tachycardia by exploring the R-R cycle. The program of external transmitter which can produce one or two sincronized impulses, seams the cycle with progressive steps of 10 msec each; when tachycardia is interrupted, further stimulation is inhibited. The implanted part of the appliance connected with a normal endocavitary electrode, does not have any power supply and thus is very small. The efficacy of this method has been shown in 4 junctional reciprocating and 1 ventricular recurrent chronic tachycardias, resistent to conventional pharmacologic therapy.

Humans↗

[Programmed electrical stimulation in the treatment of reciprocating arrhythmias. Use of radiofrequency as a stimulating and synchronising means (author's transl)].

A new model of radiofrequency stimulator is presented, which can be programmed for the transmission of one or two impulses synchronised and delayed on the endocardial electrogram. This pacemaker was successfully used in jounctional reciprocating tachycardias and in a case of recurrent ventricular tachycardia. The implanted device, connected to the electrode catheter in right ventricle, does not contain energy sources. This lets a little size and allows having outside the body all the program controls, which in the time can have to change, due to variations of the parameters of tachycardias interruption. The implanted receiver is designed to induce in the resonant coil of external transmitter a frequency modulation proportional to the endocavitary signal. A slope detector receives this signal and programs on them the stimulating impulses, transmitted to stop the tachycardia. It is possible to manufacture such a simple device that the same patient can use it. Of course, periodic controls on the patient must be made to assess the cause of the tachycardia.

Cardiac Pacing, Artificial↗