Cell constant of the tetrapolar conductivity cell.

The factors that specify the cell constant k of the tetrapolar conductivity cell are investigated. An equation to predict the value of k from the geometry of the cell is derived and validated by measuring the cell constant for different geometries in solutions of known resistivity. The constant-current method for tetrapolar resistivity measurement is used. The results show that the value of k depends only on the cell geometry and is independent of solution resistivity in the range of 30-3000 omega cm. Excellent agreement (less than 5 per cent error with a correlation coefficient of 0.99) between the predicted and the experimentally measured values of the cell constant is obtained, demonstrating that the derived expression can be used to predict the tetrapolar conductivity cell constant.

Electric Conductivity↗

End-tidal carbon dioxide concentration, carbon dioxide production, heart rate, and blood pressure as indicators of induced hyperthermia.

In 4 spontaneously breathing, barbiturate-anesthetized dogs, hyperthermia was induced with 2,4-dinitrophenol while rectal temperature, heart rate, mean blood pressure, end-tidal carbon dioxide, and carbon dioxide production (milliliters per minute) were measured continuously. The latter was determined with a pneumotachygraph (to obtain respired volume) and an infrared carbon dioxide analyzer that measured inspired and expired carbon dioxide concentration. Of the five physiologic measurements, the increase in carbon dioxide production preceded the increase in rectal temperature by more than 120 seconds. End-tidal carbon dioxide was an unreliable indicator in the spontaneously breathing animal of approaching hyperthermia during spontaneous breathing due to a transient tachypnea, which decreased end-tidal carbon dioxide. The carbon dioxide production (milliliters per minute) increased immediately and reached three to five times the control value. Blood pressure and heart rate were insensitive indicators of approaching hyperthermia.

2,4-Dinitrophenol↗

Oxygen uptake and mean blood pressure as indicators of induced hyperthermia.

This dog study was designed to identify which of two measurements (oxygen consumption, mean blood pressure) tracked the onset of hyperthermia as reflected by rectal temperature. The animals were anesthetized, paralyzed, and mechanically ventilated. Hyperthermia was induced with 2,4-dinitrophenol (5 mg/kg) injected intravenously in 5 dogs. It was found that the best and earliest predictor of approaching hyperthermia was the increase in oxygen consumption, which increased 10% in 1.72 min. Mean blood pressure was an insensitive indicator of approaching hyperthermia. Rectal temperature, not surprisingly, was found to be a late and undependable early indicator of developing hyperthermia, requiring about 15 minutes to exhibit a definite increase. It is concluded that among these indicators, monitoring oxygen consumption (ml/min) is the most reliable way to identify a metabolic change such as incipient hyperthermia.

2,4-Dinitrophenol↗

Auscultatory mean blood pressure.

This study examined the relationship between direct mean arterial blood pressure and cuff pressure for the maximum acoustic index calculated from the Korotkoff sounds in the dog. The acoustic index was computed by summing the squares of amplitudes in each Korotkoff sound complex, thereby providing a measure of acoustic energy content. Mean arterial pressure was compared with cuff pressure for the maximum acoustic index. Ten mongrel dogs were fitted with appropriately sized blood-pressure cuffs containing a microphone mounted inside the bladder and positioned over the brachial artery. The Korotkoff sounds, cuff pressure, and direct arterial pressure were recorded over a range of mean arterial pressures (23 to 155 mm Hg), achieved by manipulating the depth of anesthesia with halothane. It was found that cuff pressure at the maximum acoustic index overestimated mean arterial blood pressure by a mean of 14% (range, -8 to +30%).

Acoustics↗

Comparison of Snellen and interferometer visual acuity in an aging noncataractous population.

Using standard clinical procedures we have compared visual acuity (VA) estimates made with a hand-held white light interferometer to those obtained with a Snellen acuity chart. Fifty noncataractous patients with a mean age of 45 years (SD = 18) were tested. Snellen and interferometric acuity measures were obtained with and without refractive correction. On average, aided Snellen VA's were better (decimal acuity = 0.98) than the unaided interferometric VA's (decimal acuity = 0.67). Although we found a statistically significant p less than 0.01) correlation between unaided interferometric and aided Snellen VA's, the correlation was poor (r = 0.36). This poor correlation may account for the often observed failure to estimate postoperative aided Snellen VA with preoperative interferometric VA in cataract patients.

Adolescent↗

The use of electrically stimulated skeletal muscle to pump blood.

Electrically stimulated skeletal muscle can be used in many ways to pump blood. The important physiological characteristics of skeletal muscle for use in a cardiac assist role are presented. The force developed by a twitch and tetanic contraction are quantitated and the considerations in the choice of the stimulus applied to the innervating motor nerve are discussed. The importance of stimulus frequency and duration of the stimulus train are presented in terms of the stroke volume produced by skeletal muscle contracting around a pouch. The effect that preload has on pouch stroke volume and muscle blood flow are demonstrated. Finally an example is given in which cardiac output is augmented by an untrained, electrically stimulated, canine rectus abdominis muscle wrapped around a pouch connected between the apex of the left ventricle and the aorta. In this study, the augmentation in cardiac output was measured when the skeletal muscle was contracted after each second, third, and fourth ventricular contraction. The augmentation was 46% +/- 4, 31% +/- 7, and 25% +/- 4, respectively, for the three contraction regimens. Although electrically stimulated skeletal muscle can be used as a power source to assist the failing heart, the optimum application is yet to be discovered. Important considerations in selecting the optimal application are preload, stimulus train duration, train rate, and muscle blood flow.

Abdominal Muscles↗

Stroke volume and the three phase cardiac output rate relationship with ventricular pacing.

Knowledge of how stroke volume (SV), and hence cardiac output (CO), changes with ventricular pacing rate (R) constitutes a key aspect of sensor driven, variable rate pacemakers. It has been established that the relationship between CO and pacing rate exhibits three phases for rest and constant exercise. At low rates (phase 1), CO increases with increasing R; with additional rate increase (phase 2), CO either remains constant or increases slightly; and above some critical rate, CO decreases (phase 3). However, the nature of the relationship between SV and pacing rate has not been as clearly described. Therefore, the objectives of this study were (1) to describe and document the relationship between SV and R, and (2) to demonstrate the consequence of this relationship in terms of the three phase CO versus R relationship. In six anesthetized dogs, right ventricular SV was determined from pulmonary artery blood flow measured using an electromagnetic flow meter, and the right ventricle was paced over a range of rates. In general, SV decreased with increasing R, although the exact nature of the relationship varied from animal to animal. The results demonstrate that it is the manner in which SV decreases with increasing R that determines the three phase relationship between CO and R. The relationships described in this study have important implications for choosing pacing rates for patients receiving sensor driven, variable rate pacemakers.

Animals↗

The use of an electrically activated valve to control preload and provide maximal muscle blood flow with a skeletal-muscle ventricle.

A new method for optimally loading a skeletal muscle-wrapped pouch to act as a blood pump is described. The method takes advantage of the fact that the high preload pressure required for a forceful contraction needs to be present for only a short time. By using an electrically controlled valve to delay pouch filling until just before muscle contraction, pouch diastolic pressure can be kept low, which in turn maintains a high muscle capillary blood flow. The intrapouch precontraction pressure can be controlled by selecting the appropriate valve-open time (VOT). The pumping capabilities of untrained rectus abdominis and latissimus dorsi muscles were evaluated using a hydraulic circulatory system in a ten dog study (weight range 20-32.7 kg). The afterload was constant at 100 mmHg, and the pouch precontraction pressure, selected by choice of the VOT, was the test variable. It was found that for maximum pouch output, a precontraction pressure of 60-100 mmHg was required, being attained in this hydraulic model with a VOT of 400-500 msec. Typical pouch outputs were 400-600 mL/min with a muscle contraction rate of 40/min. Muscle capillary blood flow, measured with a periarterial electromagnetic flowmeter, varied inversely with pouch diastolic pressure and was near zero during tetanic muscle contraction. In one animal, a pouch output of 200 mL/min or more was maintained for more than 20 hours of continuous pumping without fatigue. In a related experiment, the method was applied to pump blood in a 32.7 kg dog, in which the muscle-wrapped pouch was connected between the descending thoracic aorta and the abdominal aorta. A pouch output of about 400 mL/min was obtained when the muscle was contracted 30 times/min and the VOT was 400 msec. This flow represented about 20% of the animal's cardiac output. This study demonstrates that by delaying pouch filling until just before the muscle is to be contracted, a low pouch diastolic pressure can be maintained, thereby maximizing muscle capillary blood flow and, in turn, providing the best opportunity for prolonged pumping.

Animals↗

Small intestinal submucosa as a small-diameter arterial graft in the dog.

Autogenous saphenous vein, human umbilical vein, modified bovine collagen, Dacron, and PTFE have been used as small-diameter arterial grafts with moderate success. We tested autogenous small intestine submucosa as a small-diameter arterial graft in both a carotid and femoral artery (mean ID 4.3 mm) of 18 dogs (total of 36 grafts). All dogs received aspirin and warfarin sodium for the first 8 weeks after surgery. Graft patency was evaluated by Doppler ultrasound techniques and angiography. Two grafts ruptured and 5 grafts occluded by 21 days after surgery. One graft became occluded at 14 weeks. Fifteen dogs were sacrificed at periodic intervals until 48 weeks after surgery. Patent grafts had no evidence of infection, propagating thrombus, or intimal hyperplasia. Graft aneurysmal dilation occurred in 4 grafts (11%). The grafts were composed of a dense organized collagenous connective tissue with no evidence of endothelial cell growth on the smooth luminal surface. Three dogs are alive at 76 to 82 weeks after surgery. Overall, graft patency was 75%. Graft patency after cessation of anticoagulation therapy was 92.3% (12 of 13 grafts). We conclude that autogenous small intestinal submucosa can be used as a small-diameter arterial graft in the dog and is worthy of further investigation.

Animals↗

Tracking cardiac output by a saline dilution technique using esophageal catheter electrodes.

This paper presents preliminary results of a study in which saline indicator dilution curves were obtained by measuring impedance dilution curves using a tetrapolar catheter-based electrode placed in the esophagus of anesthetized dogs. Cardiac output (CO) was calculated from the area under the impedance-derived saline dilution curve, and compared to CO calculated from the saline dilution curve obtained by a cylindrical external conductivity cell placed in an arterio-venous shunt. The results revealed an approximately two-third overestimation in CO determined using the esophageal electrodes. However, the esophageal impedance CO tracked CO determined by the conventional indicator dilution method very well. When the data were pooled, a cumulative correlation coefficient of 0.96 was obtained. Although the esophageal impedance CO method overestimates CO, it tracks changes in CO well. Further investigation is indicated to determine an optimal electrode configuration for the tetrapolar esophageal electrode.

Animals↗

Cardiac assistance with electrically stimulated skeletal muscle.

This study examined the ability of a skeletal muscle-powered assist ventricle (SMV) to augment cardiac output in ten dogs with pharmacologically induced heart failure under acute conditions. An SMV was surgically constructed in each dog by wrapping the untrained rectus abdominis muscle around a compressible pouch that was inserted into a left ventricular apex-to-aortic vascular conduit. The multiple motor nerves to the rectus muscle were then stimulated during ventricular diastole at a rate which equalled a ratio of 1:2, 1:3, or 1:4 with the natural ventricular beat. There was an increased cardiac output during SMV assistance compared with preassistance values in all ten dogs at each stimulation ratio with a mean increase of 46 +/- 4 per cent with a ratio of 1:2, 25 +/- 4 per cent with a ratio of 1:3, and 31 +/- 7 per cent with a ratio of 1:4 (p less than 0.01 for all values). The diastolic blood pressure and mean blood pressure were both increased (p less than 0.01 and p less than 0.05, respectively) during SMV stimulation at ratios of 1:2 and 1:3, but not 1:4. We have shown that untrained rectus abdominis muscle, when used as the power supply for a SMV in an apico-aortic conduit, can temporarily augment cardiac output in dogs with pharmacologically induced heart failure.

Abdominal Muscles↗

Small intestinal submucosa as a large diameter vascular graft in the dog.

Autogenous saphenous vein and synthetic materials, such as Dacron and expanded polytetrafluoroethylene, have been used extensively as vascular grafts with moderate success. Improved success rates for vascular graft surgery may be possible if superior graft material was available. We tested the use of autogenous small intestinal submucosa (SIS) as a large diameter (10 mm) vascular graft in the infrarenal aorta of 12 dogs. One dog died with graft thrombosis within 48 hr of surgery. Nine dogs were sacrificed at various times during a 52-week post-surgical period and showed patent grafts without infection, thrombosis, intimal hyperplasia, or adverse effects upon blood pressure. There was no ultrastructural evidence of endothelial cell growth on the luminal surface of the SIS graft which was composed of a dense, non-thrombogenic, organized collagenous connective tissue. The SIS material was approximately one order of magnitude less elastic than natural aorta and showed an immediate dilatation of approximately 18% after exposure to the systemic blood pressure. However, there was no progressive dilatation during the 52-week postsurgical period. Two dogs remain alive at 8 and 52 weeks post-surgery with patent grafts as determined by positive contrast radiography and Doppler studies. We conclude that autogenous small intestinal submucosa can be successfully used as a large diameter arterial graft in the dog and is worthy of further investigation.

Animals↗

A skeletal muscle ventricle made from rectus abdominis muscle in the dog.

This study examined the ability of a skeletal muscle-powered assist ventricle to augment cardiac output in 10 dogs with experimentally induced heart failure. Heart failure was induced with the use of the beta-blocking agents atenolol and propranolol. A "skeletal muscle ventricle" was then surgically constructed by wrapping the rectus abdominis muscle, with an intact neurovascular supply, around a double open-ended compressible pouch. The skeletal muscle ventricle was then interposed in a left ventricular apicoaortic conduit. The motor nerves to the skeletal muscle ventricle were stimulated by a custom designed pulse generator and caused tetanic contraction of the ventricle during diastole of every fourth natural heart beat. Stimulation was continued for 60 min. Cardiac output, systolic and diastolic blood pressures, mean blood pressure, left ventricular end diastolic pressure, and central venous pressure were then monitored prior to, during, and several times after skeletal muscle ventricle stimulation to evaluate assist ventricle function. There was an increased cardiac output in all 10 dogs at all recording times during skeletal muscle ventricle assistance compared to the cardiac output prior to stimulation of the assist ventricle. The mean increase in cardiac output after 30 min of assist ventricle stimulation was 31.0 +/- 14% (P less than 0.01), and at 60 min was 8.0 +/- 1% (P less than 0.05). The mean diastolic blood pressure after 1 and 30 min of skeletal muscle ventricle assistance (50.0 +/- 2.9 and 48.6 +/- 2.2 mm Hg, respectively) was increased (P less than 0.05) vs the preassistance value (44.9 +/- 2.8 mm Hg).(ABSTRACT TRUNCATED AT 250 WORDS)