L A DeWerd

Publications and source records attributed to L A DeWerd.

At least 19 recordsLinked to original sources

A new internal pair production branching ratio of 90Y: the development of a non-destructive assay for 90Y and 90Sr.

(90)Y is utilized as a therapeutic radioisotope in radiolabeled monoclonal antibodies and in microspheres for targeted radiation therapy of the liver. Currently, the widely used dose calibrator assay of (90)Y can have uncertainties exceeding +/-10%. A non-destructive assay using spectroscopy is possible by reducing the currently published uncertainty (+/-12%) in the internal pair production branching ratio for the 0(+)-0(+) transition of (90)Zr. A high-purity germanium detector was used to determine the branching ratio to be (31.86+/-0.47) x 10(-6).

Calibration↗

The US radiation dosimetry standards for 60Co therapy level beams, and the transfer to the AAPM accredited dosimetry calibration laboratories.

This work reports the transfer of the primary standard for air kerma from the National Institute of Standards and Technology (NIST) to the secondary laboratories accredited by the American Association of Physics in Medicine (AAPM). This transfer, performed in August of 2003, was motivated by the recent revision of the NIST air-kerma standards for 60Co gamma-ray beams implemented on July 1, 2003. The revision involved a complete recharacterization of the two NIST therapy-level 60Co gamma-ray beam facilities, resulting in new values for the air-kerma rates disseminated by the NIST. Some of the experimental aspects of the determination of the new air-kerma rates are briefly summarized here; the theoretical aspects have been described in detail by Seltzer and Bergstrom ["Changes in the U.S. primary standards for the air-kerma from gamma-ray beams," J. Res. Natl. Inst. Stand. Technol. 108, 359-381 (2003)]. The standard was transferred to reference-class chambers submitted by each of the AAPM Accredited Dosimetry Calibration Laboratories (ADCLs). These secondary-standard instruments were then used to characterize the 60Co gamma-ray beams at the ADCLs. The values of the response (calibration coefficient) of the ADCL secondary-standard ionization chambers are reported and compared to values obtained prior to the change in the NIST air-kerma standards announced on July 1, 2003. The relative change is about 1.1% for all of these chambers, and this value agrees well with the expected change in chambers calibrated at the NIST or at any secondary-standard laboratory traceable to the new NIST standard.

Accreditation↗

The effect of ambient pressure on well chamber response: experimental results with empirical correction factors.

For some air-communicating well-type chambers used for low-energy brachytherapy source assay, deviations from expected values of measured air kerma strength were observed at low pressures associated with high altitudes. This effect is consistent with an overcompensation by the air density correction to standard atmospheric temperature and pressure (P(TP)). This work demonstrates that the P(TP) correction does not fully compensate for the high altitude pressure effects that are seen with air-communicating chambers at low photon energies in the range of 20-100 keV. Deviations of up to 18% at a pressure corresponding to an approximate elevation of 8500 ft for photon energies of 20 keV are possible. For high-energy photons and for high-energy beta emitters in air-communicating chambers the P(TP) factor is applicable. As expected, the ambient pressure does not significantly affect the response of pressurized well chambers (within 1%) to either low- or high-energy photons. However, when used with beta emitters, pressurized chambers appear to exhibit a slight dependence on the ambient pressure. Using measured data, the response and correction factors were determined for three models of air-communicating well chambers for low-energy photon sources at various pressures corresponding to elevations above sea level. Monte Carlo calculations were also performed which were correlated with the experimental findings. A more complete study of the Monte Carlo calculations is presented in the accompanying paper, "The effect of ambient pressure on well chamber response: Monte Carlo calculated results for the HDR1000 Plus."

Artifacts↗

Low dose fraction behavior of high sensitivity radiochromic film.

A high sensitivity (HS) model of radiochromic film is receiving increasing use. The film's linear sensitometric response in the range of 0.5-40 Gy would make this film an ideal candidate for complex dosimetry applications that require tissue equivalence. This study investigates the potential use for clinical dosimetry of typical radiotherapy fractions at relatively low doses (0.5-5 Gy). The experiment involved exposing 25 pre-exposed pieces of HS film to five equal fractions of doses from 0.5 to 5 Gy 24 hours apart. The cumulative dose for each film was carefully monitored and optical density measurements were used as the sole determination of film response to dose. The average behavior of the various fractionation schemes was roughly consistent with previous observations of the MD-55 radiochromic film with about twice the overall sensitivity as expected. However, at low doses and low dose increments, unexpected variations beyond a well-documented low dose nonlinearity were observed. These unexpected variations may indicate complex polymer kinetics at low doses. This type of film would require extra care beyond that described in TG-55 for accurate use at low doses or low dose fraction schemes.

Dose Fractionation, Radiation↗

A thermoluminescent dosimetry postal dose inter-comparison of radiation therapy centres in Malaysia.

A thermoluminescent dosimetry (TLD) postal dose inter-comparison was carried out amongst radiotherapy centres in Malaysia. The aim of this TLD inter-comparison was to compare the uniformity involved in the measurement of absorbed dose among the participating centres. A set of 5 TLD chips placed within acrylic trays were mailed to all participating centres for irradiation to an absorbed dose to water of 2 Gy. Measurements were made for 6 MV and 60Co photon beams. Results show an agreement of +/- 5% for all but three radiotherapy centres. The ratios of the TLD readings to that of the reference centre are comparable with other national/regional dose inter-comparisons. The importance of a proper ongoing quality assurance program is essential in maintaining the consistency and uniformity of doses delivered.

Equipment Failure Analysis↗

The effect of spectra on calibration and measurement with mammographic ionization chambers.

Mammographic imaging uses x-ray tubes with molybdenum, rhodium, or tungsten anodes with the produced bremsstrahlung filtered by thin sheets of molybdenum, rhodium, or aluminum. The National Institute of Standards and Technology, the Accredited Dosimetry Calibration Laboratories, and several manufacturers offer calibrations of mammography ionization chambers with reference x-ray beams with different radiation qualities in the range 23-40 kVp. The energy response of ten commercially available chambers was determined for these reference radiation qualities using the Attix variable-length free-air chamber. The evaluated chambers are designed with thin entrance windows of varying thickness and composition. The chambers show variation in their air kerma response as a function of beam radiation quality. This response with beam radiation quality may affect the measurement of clinical beam half value layer (HVL) and the determination of the mean glandular dose. The combined effect of the chamber's energy dependence and HVL measurement affects the mean glandular dose calculation resulting in differences ranging from -1.8% to +2.5%.

Calibration↗

Assessment of the linear reference air kerma rate of 192Ir wires.

In this study, a procedure to test the linear reference air kerma rate of 192Ir wires using a well-type chamber is described. The method is based on a special lead insert with a 1 cm acrylic aperture that provides a differential response of the well chamber. The wire is considered divided into 1 cm parts. Using an external positioning system it is possible to place every part of the wire at the aperture position in the lead insert allowing measurement of each 1 cm making up the length of the wire. By means of a set of equations that take into account the contribution of all parts of the wire, in all possible positions, the relative linear reference air kerma rate is obtained. The estimated uncertainties of this procedure are about 2 to 3%. So, a well chamber and the specific inserts allow the measurements of total and linear reference air kerma rate for 192Ir wires.

Iridium Radioisotopes↗

AAPM protocol for 40-300 kV x-ray beam dosimetry in radiotherapy and radiobiology.

The American Association of Physicists in Medicine (AAPM) presents a new protocol, developed by the Radiation Therapy Committee Task Group 61, for reference dosimetry of low- and medium-energy x rays for radiotherapy and radiobiology (40 kV < or = tube potential < or = 300 kV). It is based on ionization chambers calibrated in air in terms of air kerma. If the point of interest is at or close to the surface, one unified approach over the entire energy range shall be used to determine absorbed dose to water at the surface of a water phantom based on an in-air measurement (the "in-air" method). If the point of interest is at a depth, an in-water measurement at a depth of 2 cm shall be used for tube potentials > or = 100 kV (the "in-phantom" method). The in-phantom method is not recommended for tube potentials < 100 kV. Guidelines are provided to determine the dose at other points in water and the dose at the surface of other biological materials of interest. The protocol is based on an up-to-date data set of basic dosimetry parameters, which produce consistent dose values for the two methods recommended. Estimates of uncertainties on the final dose values are also presented.

Air↗

The water-equivalence of phantom materials for 90Sr-90Y beta particles.

Intravascular brachytherapy requires that the dose be specified within millimeters of the source. High dose gradients near brachytherapy sources require that the source-detector distance be accurately known for dosimetry purposes. Solid phantoms can be designed to accommodate these stringent requirements. This study reports dosimeter readings from 90Sr-90Y sources measured in water, A150, polystyrene and in an epoxy-based water-equivalent plastic. Measurements showed that while A150 and the epoxy-based plastic agreed well with water when the surface of the source contacted the detector housing, the relative response in the phantoms decreased with increasing depth in phantom, falling to approximately 0.55 those of water at a depth of 5 mm. Readings in polystyrene were within 4% of those in water between 1 and 2 mm depth. However, while polystyrene followed water more closely than the other two materials, at greater depths the relative response in polystyrene to water varied from 0.65 to 1.34. When the density of the materials is accounted for, the relative response in A150 is nearly constant with increasing areal density. Furthermore, the response in A150 shows the closest agreement with that in water of any of the solid materials for higher areal densities. For values below 0.3 g/cm2, polystyrene shows the closest agreement with water.

Angioplasty↗

Recommendations of the American Association of Physicists in Medicine on 103Pd interstitial source calibration and dosimetry: implications for dose specification and prescription.

The National Institute of Standards and Technology (NIST) introduced a national standard for air kerma strength of the ThreaSeed Model 200 103Pd source (the only 103Pd seed available until 1999) in early 1999. Correct implementation of the NIST-99 standard requires the use of dose rate constants normalized to this same standard. Prior to the availability of this standard, the vendor's calibration procedure consisted of intercomparing Model 200 seeds with a 109Cd source with a NIST-traceable activity calibration. The AAPM undertook a comprehensive review of 103Pd source dosimetry including (i) comparison of the vendor and NIST-99 calibration standards; (ii) comparison of original Task Group 43 dosimetry parameters with more recent studies; (iii) evaluation of the vendor's calibration history; and (iv) evaluation of administered-to-prescribed dose ratios from the introduction of 103Pd sources in 1987 to the present. This review indicates that for a prescribed dose of 115 Gy, the administered doses were (a) 124 Gy for the period 1988-1997 and (b) 135 Gy for the period 1997-1999. The AAPM recommends that the following three steps should be undertaken concurrently to implement correctly the 1999 dosimetry data and NIST-99 standard for 103Pd source: (1) the vendor should provide calibrations in terms of air kerma strength traceable to NIST-99 standard, (2) the medical physicist should update the treatment planning system with properly normalized (to NIST-99) dosimetry parameters for the selected 103Pd source model, and (3) the radiation oncologist in collaboration with the medical physicist should decide which clinical experience they wish to duplicate; the one prior to 1997 or the one from 1997 to 1999. If the intent is to duplicate the experience prior to 1997, which is backed by the long-term follow-up and published outcome studies, then the prior prescriptions of 115 Gy should be replaced by 124 Gy to duplicate that experience.

Brachytherapy↗

Mammographic image quality and exposure in South East Asia.

Generally there is a significant delay before optimized performance of mammography is fully realized in the developing countries. To evaluate the status of mammographic performance, a survey of mammographic image quality and exposure was performed in nine hospitals from four selected South East Asian countries. The entrance exposure on the surface of the American College of Radiology (ACR) mammographic phantom (ACR-RMI model 156) was made using both thermoluminescent dosimeters (TLDs) and an ionization chamber. The TLDs were mailed from the University of Wisconsin Radiation Calibration Laboratory (UWRCL) to the cooperating hospitals. The surveyed hospitals processed the images and returned them to the UWRCL for subsequent evaluation of the image quality of the mammographic phantom. Machine-specific data, technique factors and sensitometric data were also obtained. At 28 kVp, the mean entrance exposure is 0.91 R (0.46 to 2.6 R), mean glandular dose is 1.61 mGy (0.90 to 4.15 mGy), mean optical density is 1.37 (0.66 to 2.30), mean total phantom image score is 9.1(4-12). Only three of the nine hospitals tested achieved an acceptable score above the minimum 10. Results for 25 and 30 kVp showed similar trend. The variation between the ion chamber measurements and TLD measurements ranged from 4 to 24%. There is a wide variation in the image quality and entrance exposure among hospitals in South East Asia. There is a need for a quality assurance program. The factors that cause low score in the phantom images must be corrected. Calibration and the use of appropriate ionization chambers for mammography is important.

Asia, Southeastern↗

Characteristics of radiation detectors for diagnostic radiology.

The use of X-rays for diagnosis has been significant since its discovery. A measurement of the X-ray dose is the main determinant for risk vs benefit of these examinations. Radiation detectors are important for dose measurement. A description of these detectors, including the most frequently used ionization chamber, aids in the understanding necessary for their use. Proper and accurate use of detectors depends on an understanding of their calibration and their characteristics. Detectors such as ionization chamber, including specialized chambers, and solid detectors, including luminescent detectors, are described. This is followed by a description of the calibration process. The precision of measurements can be greatly affected by an understanding of the detector in use.

Female↗

Guidance to users of Nycomed Amersham and North American Scientific, Inc., I-125 interstitial sources: dosimetry and calibration changes: recommendations of the American Association of Physicists in Medicine Radiation Therapy Committee Ad Hoc Subcommittee on Low-Energy Seed Dosimetry.

Dose calculations to patients undergoing implantation of 125I interstitial brachytherapy sources are affected by two recent changes in low-energy seed dosimetry: (a) implantation of a new primary air-kerma strength standard at the National Institute of Standards and Technology (NIST) on 1 January 1999 and (b) publication of revised dose-rate distributions in AAPM's Task Group 43 Report. The guidance herein represents AAPM's recommendations for users of 125I interstitial seed products marketed prior to 1 January 1999 (Nycomed Amersham models 6711 and 6702 and North American Scientific, Inc. models 3631 A/S and 3631 A/M. Implementation of Task Group 43 (TG43) 125I dose calculations involves revising data stored in files of radiation treatment planning software and lowering the prescribed dose to be delivered to patients by as much as 15% to avoid modifying the dose actually delivered to patients. The magnitude of the dose prescription change depends on the dosimetry data used prior to TG43 and the implant geometry. Adapting to the revised NIST calibration standard requires the user to increase the dose-rate constant (or its equivalent by 11.5%) but does not require modification of the prescribed dose. Failure to correctly implement these modifications can result in 20% or even 30% errors.

Brachytherapy↗

Dependence of scatter on atomic number for x rays from tungsten and molybdenum anodes in the mammographic energy range.

A study was done to determine the relative amounts of scatter for the following materials with atomic numbers ranging from Z=6 to Z=82: C, Al, Ti, Fe, Cu, Zn, Zr, Y, Mo, Ta, and Pb. Measurements were performed for each material on two constant potential x-ray units--one fitted with a molybdenum (Mo) anode-Mo filter and the other with a tungsten (W) anode-aluminum (Al) filter (medium filtration) at 30 kVp. Theoretical calculations were also performed for each anode to explain the scatter behavior and to aid in predicting the behavior for materials where measurements were not made. There was good agreement between the theoretical calculations and the experimental data.

Biophysics↗

Comparison of exposure standards in the mammography x-ray region.

Direct comparisons of the National Institute of Standards and Technology's (NIST) Ritz 20 kV to 100 kV standard free-air ionization chamber and a portable variable-length free-air ionization chamber designed by the University of Wisconsin-Madison Accredited Dosimetry Calibration Laboratory (UW-ADCL) were made on NISTs low-energy tungsten x-ray range. As a result of this direct comparison, NIST has established a UW-ADCL designed chamber, the Attix chamber, as the national standard chamber for the mammography energy x-ray range. The Ritz standard chamber and the Attix standard chamber have been extensively compared using the new molybdenum and rhodium beam qualities. The results indicate that exposure measurements in the mammography energy x-ray region with the two free-air chambers can be made with a discrepancy of less than 0.35%.

Evaluation Studies as Topic↗

Entrance skin exposure and mean glandular dose: effect of scatter and field gradient at mammography.

PURPOSE: To investigate the effect of scatter and x-ray field gradient on entrance skin exposure and mean glandular dose by using the measurement protocol of the American College of Radiology. MATERIALS AND METHODS: The exposure difference between the off-axis geometry of the American College of Radiology protocol and the central-axis geometry was measured by using eight common ionization chambers and two mammographic units (Senographe DMR; GE Medical Systems, Milwaukee, Wis; and Mam-CP II; Transcontinental X-ray, Charlotte, NC) at 25, 28, and 30 kVp. The field gradient was also measured on film with a scanning densitometer. RESULTS: The central-axis exposure was 2.0%-3.6% higher than the off-axis exposure for the Senographe DMR unit and 3.1%-8.0% higher for the Mam-CP II unit. The maximum phantom scatter was 0.7% (Senographe DMR) and 1.3% (Mam-CP II). CONCLUSION: Entrance skin exposure varies, depending on the type of ionization chamber and the characteristics of the mammographic unit. Determination of mean glandular dose with the American College of Radiology protocol may lead to underestimates of the actual measured dose by 4%-8% for the x-ray machines used in this study.

Breast↗