Search PubMed⌕ Search

Biomedical subjects

Kurtis H Yearsley

Publications and source records attributed to Kurtis H Yearsley.

2 recordsLinked to original sources

Assessment of T-cell clonality via T-cell receptor-gamma rearrangements in cutaneous T-cell-dominant infiltrates using polymerase chain reaction and single-stranded DNA conformational polymorphism assay.

Discerning the pathologic significance of cutaneous T-cell infiltrates can pose a diagnostic challenge for dermatopathologists. Reactive conditions such as drug-associated lymphomatoid hypersensitivity and lymphomatoid lupus erythematosus can demonstrate lymphoid atypia and a phenotype resembling cutaneous T-cell lymphoma (CTCL). Further, lymphoid dyscrasias such as pityriasis lichenoides chronica, large plaque parapsoriasis, and atypical pigmentary purpura confuse the picture because they not only mimic CTCL but also represent prelymphomatous states with inherent malignant potential. Although the emergence of a dominant clone has been considered a clue indicative of a T-cell dyscrasia, there are reports concerning the identification of monoclonality in biopsies of reactive lymphoid infiltrates. We have conducted a modified single-stranded DNA conformational polymorphism (SSCP) assay using paraffin-embedded, formalin-fixed tissue on 92 T-cell-rich biopsies to determine the relative specificity and sensitivity of this methodology. In addition, laser capture microdissection (LCM) was performed on 22 of the 92 samples to isolate the area of interest and to compare its specificity and sensitivity with those SSCP assays performed without LCM. We found that monoclonality or oligoclonality is 86% specific for preneoplastic and neoplastic states, whereas the finding of polyclonality appears to be relatively specific for a reactive process. Some cases of reversible T-cell dyscrasia produced a molecular profile mimicking lymphoma or prelymphomatous states by virtue of monoclonality or oligoclonality. Although LCM appears to improve the sensitivity for detecting preneoplastic conditions, the relative specificity appears to be the same as that encountered with routine SSCP.

Clone Cells↗

Using a modified standard microscope to generate virtual slides.

A standard microscope was reconfigured as a virtual slide generator by adding a Prior Scientific H101 robotic stage with H29 controller and 0.1 microm linear scales and a Hitachi HV-C20 3CCD camera. Media Cybernetics Image Pro Plus version 4 (IP4) software controlled stage movement in the X-, Y-, and Z-axis, whereas a Media Cybernetics Pro-Series Capture Kit captured images at 640 x 480 pixels. Stage calibration, scanning algorithms, storage requirements, and viewing modes were standardized. IP4 was used to montage the captured images into a large virtual slide image that was subsequently saved in TIF or JPEG format. Virtual slides were viewed at the workstation using the IP4 viewer as well as Adobe Photoshop and Kodak Imaging. MGI Zoom Server delivered the virtual slides to the Internet, and MicroBrightField's Neuroinformatica viewing software provided a browser-based virtual microscope interface together with labeling tools for annotating virtual slides. The images were served from a Windows 2000 platform with 2 GB RAM, 500 GB of disk storage, and a 1.0 GHz P4 processor. To conserve disk space on the image server, TIF files were converted to the FlashPix (FPX) file format using a compression ratio of 10:1. By using 4x, 10x, 20x, and 40x objectives, very large gigapixel images of tissue whole-mounts and tissue arrays with high quality and morphologic detail are now being generated for teaching, publication, research, and morphometric analysis. Technical details and a demonstration of our system can be found on the Web at http://virtualmicroscope.osu.edu.

Anatomy, Cross-Sectional↗