Search PubMed⌕ Search

Biomedical subjects

Kuan J Lee

Publications and source records attributed to Kuan J Lee.

5 recordsLinked to original sources

Simultaneous parallel inclined readout image technique.

Sensitivity-encoded phase undersampling has been combined with simultaneous slice excitation to produce a parallel MRI method with a high volumetric acquisition acceleration factor without the need for auxiliary stepped field coils. Dual-slice excitation was produced by modulating both spin and gradient echo sequences at +/-6 kHz. Frequency aliasing of simultaneously excited slices was prevented by using an additional gradient applied along the slice axis during data acquisition. Data were acquired using a four-channel receiver array and x4 sensitivity encoding on a 1.5 T MR system. The simultaneous parallel inclined readout image technique has been successfully demonstrated in both phantoms and volunteers. A multiplicative image acquisition acceleration factor of up to x8 was achieved. Image SNR and resolution was dependent on the ratio of the readout gradient to the additional slice gradient. A ratio of approximately 2:1 produced acceptable image quality. Use of RF pulses with additional excitation bands should enable the technique to be extended to volumetric acquisition acceleration factors in the range of x16-24 without the SNR limitations of pure partially parallel phase reduction methods.

Algorithms↗

Parallel imaging of hyperpolarized helium-3 with simultaneous slice excitation.

Hyperpolarized (HP) gas imaging of the lungs is an ideal potential application for parallel imaging. This is due to the fact that there is limited scan time (breath hold of 20 s) and limited non-renewable polarization. Reduced phase encode parallel imaging is demanding on hardware in that it requires multiple receivers. In this work, simultaneous parallel acquisition of hyperpolarized (HP) 3He images from multiple slices was demonstrated in phantoms and in vivo using a simultaneous slice excitation method, at a field strength of 1.5 T. The pulse sequence allows simultaneous acquisition of n slices per RF excitation, thus reducing the number of RF pulses needed to fully cover a given volume with multi-slicing. Unlike conventional parallel imaging, this method does not require prior reference scan information, which would consume some of the finite longitudinal polarization in lung ventilation studies with HP gas.

Artifacts↗

Automated gamma knife radiosurgery treatment planning with image registration, data-mining, and Nelder-Mead simplex optimization.

Gamma knife treatments are usually planned manually, requiring much expertise and time. We describe a new, fully automatic method of treatment planning. The treatment volume to be planned is first compared with a database of past treatments to find volumes closely matching in size and shape. The treatment parameters of the closest matches are used as starting points for the new treatment plan. Further optimization is performed with the Nelder-Mead simplex method: the coordinates and weight of the isocenters are allowed to vary until a maximally conformal plan specific to the new treatment volume is found. The method was tested on a randomly selected set of 10 acoustic neuromas and 10 meningiomas. Typically, matching a new volume took under 30 seconds. The time for simplex optimization, on a 3 GHz Xeon processor, ranged from under a minute for small volumes (<1000 cubic mm, 2-3 isocenters), to several tens of hours for large volumes (>30,000 cubic mm, >20 isocenters). In 8/10 acoustic neuromas and 8/10 meningiomas, the automatic method found plans with conformation number equal or better than that of the manual plan. In 4/10 acoustic neuromas and 5/10 meningiomas, both overtreatment and undertreatment ratios were equal or better in automated plans. In conclusion, data-mining of past treatments can be used to derive starting parameters for treatment planning. These parameters can then be computer optimized to give good plans automatically.

Automation↗

B1AC-MAMBA: B1 array combined with multiple-acquisition micro B0 array parallel magnetic resonance imaging.

The combination of an in-plane B(1) sensitivity encoding (SENSE) technique with a simultaneous multiple-slice B(0) field step technique (multiple-acquisition micro B(0) array (MAMBA)) has produced high scan time reduction factors (R < or = 8). In this study, two slices were acquired simultaneously in combination with x2 and x4 SENSE in-plane encoding using a MAMBA stepped B(0) field coil inside a four-channel phased-array coil system. Experiments were performed on a 1.5 T Infinion system (Philips Medical Systems, Cleveland, OH). The signal-to-noise ratio (SNR) was reduced with higher R factors, as was expected from the reduced number of acquisitions used to create the unaliased images. The combination of SENSE and MAMBA offers great promise for reducing scan times through parallel acquisition while at the same time reducing the number of RF channels required by a factor equal to the number of field steps employed. The B(1) array combined with MAMBA (B(1)AC-MAMBA) technique is applicable when the length of an object is much greater than its diameter, as in scanning limbs or in whole-body screening for disease.

Artifacts↗

Interleaved pulsed MAMBA: a new parallel slice imaging method.

A method of acquiring slices in parallel is described which uses interleaved sets of pulsed B(0) field coils to generate discrete regions of uniform field within the main magnetic field known as interleaved MAMBA (multiple acquisition micro B(0) array). Simulations of a number of coil designs were performed using the Biot-Savart law. A six-step coil was built and interfaced to a 0.17 T Niche MRI system and the field steps measured using an imaging technique. Measured field steps were in good agreement with the values predicted by simulation. The coil design was then scaled up by a factor of three, interfaced to a 1.5 T whole-body MRI system, and scans of the hands and arms of volunteers were acquired from up to four field steps using standard spin and gradient echo sequences. Images were also acquired simultaneously from two field steps with no frequency encode aliasing and one excitation. The one-dimensional interleaved pulsed MAMBA step field technique shows great promise for enabling many slices to be acquired simultaneously along the axis of the coil for rapid volumetric studies without the need for multiple shot Hadamard encoding. Extension of interleaved coil design to two or three dimensions is feasible, which could provide full spatial coverage combined with ultra-rapid data acquisition.

Echo-Planar Imaging↗