Search PubMed⌕ Search

Biomedical subjects

Kristin N Schultz

Publications and source records attributed to Kristin N Schultz.

2 recordsLinked to original sources

Monitoring dopamine in vivo by microdialysis sampling and on-line CE-laser-induced fluorescence.

Microdialysis sampling was coupled on-line to micellar electrokinetic chromatography (MEKC) to monitor extracellular dopamine concentration in the brains of rats. Microdialysis probes were perfused at 0.3 microL/min and the dialysate mixed on-line with 6 mM naphthalene-2,3-dicarboxaldehye and 10 mM potassium cyanide pumped at 0.12 microL/min each into a reaction capillary. The reaction mixture was delivered into a flow-gated interface and separated at 90-s intervals. The MEKC separation buffer consisted of 30 mM phosphate, 6.5 mM SDS, and 2 mM HP-beta-CD at pH 7.4, and the electric field was 850 V/cm applied across a 14-cm separation distance. Analytes were detected by laser-induced fluorescence excited using the 413-nm line of a 14-mW diode-pumped laser. The detection limit for dopamine was 2 nM when sampling by dialysis. The basal dopamine concentration in dialysates collected from the striatum of anesthetized rats was 18 +/- 3 nM (n = 12). The identity of the putative dopamine peak was confirmed by showing that dopamine uptake inhibitors increased the peak and dopamine synthesis inhibitors eliminated the peak. The utility of this method for behavioral studies was demonstrated by correlating dopamine concentrations in vivo and with psychomotor behavior in freely moving rats following the intravenous administration of cocaine. Over 60 additional peaks were detected in the electropherograms, suggesting the potential for monitoring many other substances in vivo by this method.

Animals↗

Systematic error in automated in-tube solid-phase microextraction.

The widely employed configuration for automated in-tube solid-phase microextraction (SPME) involves modification of a commercial liquid chromatographic autosampler into an automated extraction device. This popular configuration is demonstrated to result in an inherent systematic error in the quantitation of analyte in a given matrix. The source of error is traced to the accumulation of analyte in the extraction and the pre-extraction segment (i.e., sample loop, metering valve and tubing prior to the metering valve) of the autosampler where the analyte comes in contact with the residual mobile phase. This results in cross-contamination due to sample/mobile phase mixing. The quantity of analyte accumulated in these segments is shown to consistently increase with the increasing number of draw/eject cycles. As a result of the accumulation, the amount of analyte recorded leads to inaccurate quantitative information, leading to overestimation of the limit of detection and limit of quantitation, when automated in-tube SPME is employed as an approach for sample enrichment. Insertion of a 100-microl air plug prior to extraction step was able to significantly minimize sample/mobile phase mixing of analyte with the residual mobile phase in the pre-extraction and extraction step, thus minimizing the systematic error.

Automation↗