Saturated double-angle method for rapid B1+ mapping.

For in vivo magnetic resonance imaging at high field (> or =3 T) it is essential to consider the homogeneity of the active B(1) field (B(1)+), particularly if surface coils are used for RF transmission. A new method is presented for highly rapid B(1)+ magnitude mapping. It combines the double angle method with a B(1)-insensitive magnetization-reset sequence such that the choice of repetition time (TR) is independent of T(1) and with a multislice segmented (spiral) acquisition to achieve volumetric coverage with adequate spatial resolution in a few seconds. Phantom experiments confirmed the accuracy of this technique even when TR << T(1), with the side effect being lowered SNR. The speed of this method enabled B(1)+ mapping in the chest and abdomen within a single breath-hold. In human cardiac imaging, the method enabled whole-heart coverage within a single 16-s breath-hold. Results from phantoms and healthy volunteers at 1.5 T and 3 T are presented.

Algorithms↗

Rapid cardiac-output measurement with ungated spiral phase contrast.

An ungated spiral phase-contrast (USPC) method was used to measure cardiac output (CO) rapidly and conveniently. The USPC method, which was originally designed for small peripheral vessels, was modified to assess CO by measuring flow in the ascending aorta (AA). The modified USPC used a 12-interleaf spiral trajectory to acquire full-image data every 283 ms with 2-mm spatial resolution. The total scan time was 5 s. For comparison, a triggered real-time (TRT) method was used to indirectly calculate CO by measuring left-ventricular (LV) volume. The USPC and TRT measurements from all normal volunteers agreed. In a patient with patent ductus arteriosus (PDA), high CO was measured with USPC, which agreed well with the invasive cardiac-catheterized measurement. In normal volunteers, CO dropped about 20-30% with Valsalva maneuvering, and increased about 100% after exercise. Continuous 28-s cycling between Valsalva maneuvering and free-breathing showed that USPC can temporally resolve physiological CO changes.

Adult↗

Real-time color-flow CMR in adults with congenital heart disease.

CMR is valuable in the evaluation of congenital heart disease (CHD). Traditional flow imaging sequences involve cardiac and respiratory gating, increasing scan time and susceptibility to arrhythmias. We studied a real-time color-flow CMR system for the detection of flow abnormalities in 13 adults with CHD. All 16 congenital flow abnormalities previously detected by echocardiography were visualized using color-flow CMR, including atrial septal defects (n = 4), ventricular septal defects (n = 9), aortic coarctation (n = 1), Blalock-Taussig shunt (n = 1) and Fontan shunt (n = 1). Real-time color-flow CMR can identify intra- and extra-cardiac flow abnormalities in adults with congenital heart disease.

Adult↗

Rapid measurement of renal artery blood flow with ungated spiral phase-contrast MRI.

PURPOSE: To verify the potential of ungated spiral phase-contrast (USPC), which has been shown to provide accurate and reproducible time-averaged measurements of pulsatile flow, for rapid measurement of renal artery blood flow (RABF) in vivo. MATERIALS AND METHODS: The RABF rates of 11 normal human subjects and one patient with renal failure were measured with USPC within six seconds. RESULTS: Rapid USPC scans produced reproducible RABF measurements (SD < or = 9%) that agreed with the normal RABF rates known from the literature. The RABF rates of the patient with renal failure were substantially less (<50-65%) than the normal RABF rates. CONCLUSION: The results demonstrate that it is now possible to obtain rapid and consistent RABF measurements within six seconds with USPC.

Adult↗

High-resolution real-time spiral MRI for guiding vascular interventions in a rabbit model at 1.5 T.

PURPOSE: To study the feasibility of a combined high spatial and temporal resolution real-time spiral MRI sequence for guiding coronary-sized vascular interventions. MATERIALS AND METHODS: Eight New Zealand White rabbits (four normal and four with a surgically-created stenosis in the abdominal aorta) were studied. A real-time interactive spiral MRI sequence combining 1.1 x 1.1 mm(2) in-plane resolution and 189-msec total image acquisition time was used to image all phases of an interventional procedure (i.e., guidewire placement, balloon angioplasty, and stenting) in the rabbit aorta using coronary-sized devices on a 1.5 T MRI system. RESULTS: Real-time spiral MRI identified all rabbit aortic stenoses and provided high-temporal-resolution visualization of guide-wires crossing the stenoses in all animals. Angioplasty balloon dilatation and deployment of coronary-sized copper stents in the rabbit aorta were also successfully imaged by real-time spiral MRI. CONCLUSION: Combining high spatial and temporal resolution with spiral MRI allows real-time MR-guided vascular intervention using coronary-sized devices in a rabbit model. This is a promising approach for guiding coronary interventions.

Animals↗

Spiral balanced steady-state free precession cardiac imaging.

Balanced steady-state free precession (SSFP) sequences are useful in cardiac imaging because they achieve high signal efficiency and excellent blood-myocardium contrast. Spiral imaging enables the efficient acquisition of cardiac images with reduced flow and motion artifacts. Balanced SSFP has been combined with spiral imaging for real-time interactive cardiac MRI. New features of this method to enable scanning in a clinical setting include short, first-moment nulled spiral trajectories and interactive control over the spatial location of banding artifacts (SSFP-specific signal variations). The feasibility of spiral balanced SSFP cardiac imaging at 1.5 T is demonstrated. In observations from over 40 volunteer and patient studies, spiral balanced SSFP imaging shows significantly improved contrast compared to spiral gradient-spoiled imaging, producing better visualization of cardiac function, improved localization, and reduced flow artifacts from blood.

Artifacts↗

Variable-density one-shot Fourier velocity encoding.

In areas of highly pulsatile and turbulent flow, real-time imaging with high temporal, spatial, and velocity resolution is essential. The use of 1D Fourier velocity encoding (FVE) was previously demonstrated for velocity measurement in real time, with fewer effects resulting from off-resonance. The application of variable-density sampling is proposed to improve velocity measurement without a significant increase in readout time or the addition of aliasing artifacts. Two sequence comparisons are presented to improve velocity resolution or increase the velocity field of view (FOV) to unambiguously measure velocities up to 5 m/s without aliasing. The results from a tube flow phantom, a stenosis phantom, and healthy volunteers are presented, along with a comparison of measurements using Doppler ultrasound (US). The studies confirm that variable-density acquisition of kz-kv space improves the velocity resolution and FOV of such data, with the greatest impact on the improvement of FOV to include velocities in stenotic ranges.

Aorta, Abdominal↗

The future of real-time cardiac magnetic resonance imaging.

Dynamic changes in cardiac structure and function are usually examined by real-time imaging techniques such as angiography or echocardiography. MRI has many advantages compared with these established cardiac imaging modalities. However, system hardware and software limitations have limited cardiac MRI to gated acquisitions that are lengthy and often result in failed acquisitions and examinations. Recently, MRI has evolved into a technique capable of imaging dynamic processes in real time. Improvements in hardware, pulse sequences, and image reconstruction algorithms have enabled real-time cardiac MRI with high spatial resolution, high temporal resolution, and various types of image contrast without requiring cardiac gating or breath-holding. This article provides an overview of current capability and highlights key technical and clinical advances. The future prospects of real-time cardiac MRI will depend on 1) the development of techniques that further improve signal to noise ratio, contrast, spatial resolution, and temporal resolution, without introducing artifacts; 2) the development of software infrastructure that facilitates rapid interactive examination; and 3) the development and validation of several new clinical assessments.

Computer Systems↗

Real-time cardiac MRI at 3 tesla.

Real-time cardiac and coronary MRI at 1.5T is relatively "signal starved" and the 3T platform is attractive for its immediate factor of two increase in magnetization. Cardiac imaging at 3T, however, is both subtly and significantly different from imaging at 1.5T because of increased susceptibility artifacts, differences in tissue relaxation, and RF homogeneity issues. New RF excitation and pulse sequence designs are presented which deal with the fat-suppression requirements and off-resonance issues at 3T. Real-time cardiac imaging at 3T is demonstrated with high blood SNR, blood-myocardium CNR, resolution, and image quality, using new spectral-spatial RF pulses and fast spiral gradient echo pulse sequences. The proposed sequence achieves 1.5 mm in-plane resolution over a 20 cm FOV, with a 5.52 mm measured slice thickness and 32 dB of lipid suppression. Complete images are acquired every 120 ms and are reconstructed and displayed at 24 frames/sec using a sliding window. Results from healthy volunteers show improved image quality, a 53% improvement in blood SNR efficiency, and a 232% improvement in blood-myocardium CNR efficiency compared to 1.5T.

Adipose Tissue↗

Real-time imaging of skeletal muscle velocity.

PURPOSE: To test the feasibility of using real-time phase contrast (PC) magnetic resonance imaging (MRI) to track velocities (1-20 cm/second) of skeletal muscle motion. MATERIALS AND METHODS: To do this we modified a fast real-time spiral PC pulse sequence to accommodate through-plane velocity encoding in the range of -20 to +20 cm/second. We successfully imaged motion of the biceps brachii and triceps brachii muscles during elbow flexion and extension in seven unimpaired adult subjects using real-time PC MRI. RESULTS: The velocity data demonstrate that the biceps brachii and the triceps brachii, antagonistic muscles, move in opposite directions during elbow flexion and extension with velocity values in the muscle tissue ranging from -10 to +10 cm/second. CONCLUSION: With further development, real-time PC MRI may provide a means to analyze muscle function in individuals with neurologic or movement disorders who cannot actively complete the repeated motions required for dynamic MRI techniques, such as cine PC MRI, that are more commonly used in musculoskeletal biomechanics applications.

Adult↗

Triggered real-time MRI and cardiac applications.

Real-time interactive MRI is becoming the method of choice for many cardiac applications. One current limitation of real-time techniques is inaccurate slice registration during free-breathing. A simple "triggered real-time" imaging approach is proposed which enables the acquisition of synchronized and accurately registered real-time movie loops during short breathholds. Initial in vivo results demonstrate application to complete 4D ventricular function assessment and fully resolved flow imaging.

Anatomy↗

Fat-suppressed steady-state free precession imaging using phase detection.

Fully refocused steady-state free precession (SSFP) is a rapid, efficient imaging sequence that can provide diagnostically useful image contrast. In SSFP, the signal is refocused midway between excitation pulses, much like in a spin-echo experiment. However, in SSFP, the phase of the refocused spins alternates for each resonant frequency interval equal to the reciprocal of the sequence repetition time (TR). Appropriate selection of the TR results in a 180 degrees phase difference between lipid and water signals. This phase difference can be used for fat-water separation in SSFP without any increase in scan time. The technique is shown to produce excellent non-contrast-enhanced, flow-independent angiograms of the peripheral vasculature.

Adipose Tissue↗

Rapid quantitation of high-speed flow jets.

Flow jets containing velocities up to 5-7 m/s are common in patients with congenital defects and patients with valvular disease (stenosis and regurgitation). The quantitation of peak velocity and flow volume in these jets is clinically significant but requires specialized imaging sequences. Conventional 2DFT phase contrast sequences require lengthy acquisitions on the order of several minutes. Conventional spiral phase contrast sequences are faster, but are highly corrupted by flow artifacts at these high velocities due to phase dispersion and motion during the excitation and readout. A new prospectively gated method based on spiral phase contrast is presented, which has a sufficiently short measurement interval (<4 ms) to minimize flow artifacts, while achieving high spatial resolution (2 x 2 x 4 mm(3)) to minimize partial volume effects, all within a single breathhold. A complete single-slice phase contrast movie loop with 22 ms true temporal resolution is acquired in one 10-heartbeat breathhold. Simulations indicate that this technique is capable of imaging through-plane jets with velocities up to 10 m/s, and initial studies in aortic stenosis patients show accurate in vivo measurement of peak velocities up to 4.2 m/s (using echocardiography as a reference).

Aortic Valve Stenosis↗

In vivo real-time intravascular MRI.

PURPOSE: The Magnetic resonance imaging (MRI) is an emerging technology for catheter-based imaging and interventions. Real-time MRI is a promising methodfor overcoming catheter and physiologic motion for intravascular imaging. METHODS: All imaging was performed on a 1.5 T Signa MRI scanner with high-speed gradients. Multiple catheter coils were designed and constructed, including low-profile, stub-matched coils. Coil sensitivity patterns and SNR measurements were compared. Real-time imaging was performed with an interleaved spiral sequence using a dedicated workstation, providing real-time data acquisition, image reconstruction and interactive control and display. Real-time "black-blood" imaging was achieved through incorporation of off-slice saturation pulses. The imaging sequence was tested in a continuous flow phantom and then in vivo in the rabbit aorta using a 2 mm catheter coil. RESULTS: The real-time intravascular imaging sequence achieved 120-440 micron resolution at up to 16 frames per second. Low-profile stub-tuned catheter coils achieved similar SNR to larger traditional coil designs. In the phantom experiments, addition of real-time black-blood saturation pulses effectively suppressed the flow signal and allowed visualization of the phantom wall. In vivo experiments clearly showed real-time intravascular imaging of the rabbit aortic wall with minimal motion artifacts and effective blood signal suppression. CONCLUSIONS: Real-time imaging with low-profile coil designs provides significant enhancements to intravascular MRI.

Animals↗