Search PubMed⌕ Search

Biomedical subjects

Konstantin Nikolaou

Publications and source records attributed to Konstantin Nikolaou.

At least 19 recordsLinked to original sources

ECG-gated 64-MDCT angiography in the differential diagnosis of acute chest pain.

OBJECTIVE: The most important differential diagnoses of acute chest pain include myocardial infarction, aortic dissection, and pulmonary embolism. The purpose of this study was to evaluate the diagnostic value of an ECG-gated 64-MDCT angiography protocol for simultaneous assessment of the pulmonary arteries, coronary arteries, and aorta within a single breath-hold. SUBJECTS AND METHODS: In 55 patients with acute chest pain, ECG-gated CT angiography was performed with a CT system in which 64 slices per gantry rotation were acquired. Density measurement and visual assessment of motion artifacts were performed to evaluate image quality. CT findings were correlated with results of laboratory tests and clinical follow-up. For 20 patients, two independent blinded reviewers compared findings on CT angiography with those on X-ray coronary angiography. RESULTS: Adequate contrast enhancement of the pulmonary vessels, coronary arteries, and aorta was achieved in all cases. Regarding image quality of the coronary arteries, there was minor blurring in seven patients, and in one examination the images did not provide enough information for diagnosis. The average image quality rating was 1.2 on a scale in which 1 indicated no artifacts; 2, minor motion artifacts; and 3, image insufficient for diagnosis. The cause of chest pain was correctly identified with MDCT in 37 patients. The diagnoses included pulmonary embolism (n = 10), coronary stenosis (n = 9), and aortic dissection (n = 1). In four patients, additional diagnoses were found with other examinations. CONCLUSION: With current techniques, ECG-gated CT angiography of the entire chest has very good image quality. The protocol proved helpful in the differential diagnosis of acute chest pain.

Acute Disease↗

Visual and automatic grading of coronary artery stenoses with 64-slice CT angiography in reference to invasive angiography.

The aim of this study was to assess the performance of a software tool for quantitative coronary artery analysis of computed tomography coronary angiography (CT-QCA) in comparison with invasive coronary angiography with quantitative analysis (CAG-QCA) as standard of reference. Two radiologists reviewed the CT angiography data sets (Siemens Sensation 64) of 25 patients, grading coronary artery stenoses visually and with a software tool (Circulation, Siemens). Twenty-three data sets with sufficient image quality were included in the final analysis. CAG revealed a total of 30 wall irregularities and 28 stenoses, of which 17 were graded as moderate and nine as hemodynamically significant. CT-QCA showed a better agreement to CAG-QCA, with a systematic overestimation of the degree of stenosis of 6.1% and limits of agreement of +36.1% and -23.9; the correlation coefficient was 0.82 (p < 0.0001). Using CT-QCA, sensitivity, specificity, and positive and negative predictive value were 89%, 100%, 89%, and 100%, respectively, for significant area stenoses greater than 75%. The positive predictive value for the visual assessment amounted to 53%. Interobserver variability between CT-QCA and visual assessment showed a kappa value of 0.72. In conclusion, software-supported CT-QCA makes it possible to quantify significant coronary artery stenoses automatically, with good agreement to CAG-QCA.

Contrast Media↗

High-spatial-resolution multistation MR angiography with parallel imaging and blood pool contrast agent: initial experience.

The purpose of this study was to prospectively evaluate the diagnostic accuracy of reader detection of 75% or greater stenosis at high-spatial-resolution multistation magnetic resonance (MR) angiography performed with matrix coils and a blood pool contrast agent. Ten healthy volunteers and 10 patients were examined. All participants provided informed consent to participate in this institutional review board-approved study. For contrast agent-enhanced multistation MR angiography, an albumin-binding gadolinium chelate, gadofosveset trisodium, was used. Imaging was performed during the first-pass and steady-state phases of the contrast agent. Vessel conspicuity on the first-pass MR angiograms obtained in both volunteers and patients was rated as excellent for 93% of vessels. At steady-state imaging, vessel conspicuity was rated as excellent or good for 89% of vessels. Gadofosveset trisodium-enhanced MR angiography yielded sensitivities of 100% and 97% and specificities of 96% and 97% for detection of significant disease in the carotid and lower extremity arteries, respectively.

Adult↗

Sixty-four slice spiral CT angiography does not predict the functional relevance of coronary artery stenoses in patients with stable angina.

PURPOSE: The aim of this study was to evaluate spiral multidetector computed tomography (MDCT) angiography using 64-slice technique in the detection of functionally relevant coronary artery stenoses (CAS). METHODS: Thirty-eight patients (62+/-11 years, 28 men) with stable angina (26 with suspected and 12 with known coronary artery disease) were investigated using 64-slice MDCT angiography and gated myocardial perfusion SPECT (gated SPECT); a subgroup of 30 patients had additional invasive coronary angiography (ICA). Stenoses with luminal narrowing of >or=50% were defined as "significant" in MDCT angiography and ICA. MDCT angiography was compared with gated SPECT and the combination of gated SPECT plus ICA with respect to the detection of functionally relevant CAS. RESULTS: The sensitivity, specificity and negative and positive predictive values of MDCT angiography in detecting reversible perfusion defects on gated SPECT were 63%, 80%, 94% and 32%, respectively, in vessel-based analysis and 71%, 62%, 72% and 60%, respectively, in patient-based analysis. If only reversible perfusion defects on gated SPECT with CAS >or=50% on ICA were considered, the sensitivity, specificity and negative and positive predictive values were, respectively, 85%, 79%, 98% and 33% for vessel-based analysis and 85%, 59%, 83% and 61% for patient-based analysis. CONCLUSION: Sixty-four slice MDCT angiography failed to predict the functional relevance of CAS, but had a high negative predictive value in the exclusion of functionally relevant CAS in symptomatic patients.

Angina Pectoris↗

Dual-source CT cardiac imaging: initial experience.

The relation of heart rate and image quality in the depiction of coronary arteries, heart valves and myocardium was assessed on a dual-source computed tomography system (DSCT). Coronary CT angiography was performed on a DSCT (Somatom Definition, Siemens) with high concentration contrast media (Iopromide, Ultravist 370, Schering) in 24 patients with heart rates between 44 and 92 beats per minute. Images were reconstructed over the whole cardiac cycle in 10% steps. Two readers independently assessed the image quality with regard to the diagnostic evaluation of right and left coronary artery, heart valves and left ventricular myocardium for the assessment of vessel wall changes, coronary stenoses, valve morphology and function and ventricular function on a three point grading scale. The image quality ratings at the optimal reconstruction interval were 1.24+/-0.42 for the right and 1.09+/-0.27 for the left coronary artery. A reconstruction of diagnostic systolic and diastolic images is possible for a wide range of heart rates, allowing also a functional evaluation of valves and myocardium. Dual-source CT offers very robust diagnostic image quality in a wide range of heart rates. The high temporal resolution now also makes a functional evaluation of the heart valves and myocardium possible.

Algorithms↗

Detection of healed myocardial infarction with multidetector-row computed tomography and comparison with cardiac magnetic resonance delayed hyperenhancement.

Decreased myocardial attenuation on contrast-enhanced multidetector computed tomography (MDCT) images can be observed in subjects with myocardial infarctions (MIs). It was hypothesized that myocardial hypoattenuation in MDCT can accurately detect the presence of a healed MI as determined by cardiac magnetic resonance delayed hyperenhancement (CMR-DH). Coronary MDCT and CMR-DH were performed in 42 subjects. Pre- and postcontrast MDCT images were analyzed for the presence of myocardial hypoattenuation, and volumes of MIs were quantified on MDCT and CMR-DH images in a blinded manner. The sensitivity, specificity, and negative and positive predictive values of postcontrast MDCT for the detection of MI were 91%, 81%, 83%, and 90%, respectively. MI sizes by postcontrast MDCT and by CMR-DH were strongly correlated (r=0.87, p<0.0001), although MDCT systematically underestimated MI volume (2.7+/-2.5 vs 25.9+/-19.9 ml, p<0.0001). MI size by MDCT was correlated negatively with the left ventricular ejection fraction (r=-0.62, p=0.03) and positively with left ventricular volumes (r=0.68 to 0.72, p<0.01). In 71% of subjects with MIs by CMR-DH, corresponding areas of hypoattenuation were noted also in precontrast MDCT. In conclusion, healed MIs can be detected as areas of myocardial hypoattenuation on MDCT images with high diagnostic accuracy, although their sizes are largely underestimated compared with CMR-DH. The presence of precontrast hypoattenuation suggests that mechanisms independent of reduced contrast delivery contribute to this finding.

Adolescent↗

High-resolution ex vivo imaging of coronary artery stents using 64-slice computed tomography--initial experience.

The aim of the study was to evaluate the potential of new-generation multi-slice computed tomography (CT) scanner technology for the delineation of coronary artery stents in an ex vivo setting. Nine stents of various diameters (seven stents 3 mm, two stents 2.5 mm) were implanted into the coronary arteries of ex vivo porcine hearts and filled with a mixture of an iodine-containing contrast agent. Specimens were scanned with a 16-slice CT (16SCT) machine; (Somatom Sensation 16, Siemens Medical Solutions), slice thickness 0.75 mm, and a 64-slice CT (64SCT, Somatom Sensation 64), slice-thickness 0.6 mm. Stent diameters as well as contrast densities were measured, on both the 16SCT and 64SCT images. No significant differences of CT densities were observed between the 16SCT and 64SCT images outside the stent lumen: 265+/-25HU and 254+/-16HU (P=0.33), respectively. CT densities derived from the 64SCT images and 16SCT images within the stent lumen were 367+/-36HU versus 402+/-28HU, P<0.05, respectively. Inner and outer stent diameters as measured from 16SCT and 64SCT images were 2.68+/-0.08 mm versus 2.81+/-0.07 mm and 3.29+/-0.06 mm versus 3.18+/-0.07 mm (P<0.05), respectively. The new 64SCT scanner proved to be superior in the ex vivo assessment of coronary artery stents to the conventional 16SCT machine. Increased spatial resolution allows for improved assessment of the coronary artery stent lumen.

Animals↗

Accuracy of 64-slice computed tomography to classify and quantify plaque volumes in the proximal coronary system: a comparative study using intravascular ultrasound.

OBJECTIVES: We evaluated the accuracy of a new 64-slice computed tomography (CT) scanner, compared with intravascular ultrasound, to visualize atherosclerosis in the proximal coronary system. BACKGROUND: Noninvasive determination of plaque composition and plaque burden may be important to improve risk stratification. METHODS: In 20 patients, a 64-slice CT scan (Sensation 64, Siemens Medical Solutions, Forchheim, Germany) and an intravascular ultrasound investigation of vessels without stenosis >50% was performed. Diagnostic image quality with 64-slice CT was obtained in 36 vessels in 19 patients. RESULTS: In these vessels, which were divided in 3-mm sections, 64-slice CT enabled a correct detection of plaque in 54 of 65 (83%) sections containing noncalcified plaques, 50 of 53 (94%) sections containing mixed plaques, and 41 of 43 (95%) sections containing calcified plaques. In 192 of 204 (94%) sections, atherosclerotic lesions were excluded correctly. In addition, 64-slice CT enabled the visualization of 7 of 10 (70%) sections revealing a lipid pool and could identify a spotty calcification pattern in 27 of 30 (90%) sections. The correlation coefficient to determine plaque volumes per vessel was r2 = 0.69 (p < 0.001) with an underestimation of mixed and noncalcified plaque volumes (p < 0.03) and a trend to overestimate calcified plaque volumes by 64-slice CT. The interobserver variability to determine plaque volumes was 37%. Interobserver agreement to identify atherosclerotic sections was good (Cohen's kappa coefficient = 0.75). CONCLUSIONS: We conclude that 64-slice CT reveals encouraging results to noninvasively detect different types of coronary plaques located in the proximal coronary system. The ability to determine plaque burden currently is hampered by mainly an insufficient reproducibility.

Coronary Angiography↗

Cardiac CINE MR imaging with a 32-channel cardiac coil and parallel imaging: impact of acceleration factors on image quality and volumetric accuracy.

PURPOSE: To assess the impact of parallel imaging algorithms on image quality and volumetric accuracy of CINE magnetic resonance imaging (MRI) with high temporal and spatial resolution using a new 32-channel dedicated cardiac phased array coil. MATERIALS AND METHODS: Fourteen individuals underwent steady-state free precession (SSFP) CINE MRI using a 32-element phased-array coil and parallel imaging acceleration using spatiotemporal sensitivity encoding (TSENSE). Acquisition acceleration ranged from R = 2 to 7. In conjunction with data extracted from phantom measurements, contrast-to-noise ratio (CNR) performance was evaluated for each acceleration factor and subjective image quality was evaluated by two independent readers. In addition, volumetric assessment was performed for each acceleration factor based on a single breath-hold multi-slice data acquisition. Results were compared to nonTSENSE measurements. RESULTS: CNR for non-accelerated CINE (R = 1) was 45.7 +/- 12.8 and showed a constant decrease with increase in acceleration of 51% at R = 4 and 86% at R = 7. CNR losses accompanied reductions in subjective image quality. Volumetric evaluation was accurate for R <or= 4, with significant underestimation of ejection fraction (EF) at higher accelerations. CONCLUSION: This study shows that one-dimensional acceleration factors up to R = 4 allow accurate SSFP CINE MRI even though CNR is significantly reduced. This allows for a marked reduction in scan time and allows for multi-slice CINE imaging with high spatial and temporal resolution.

Adult↗

Assessment of coronary artery stent patency and restenosis using 64-slice computed tomography.

RATIONALE AND OBJECTIVES: Restenosis remains a major limitation of coronary catheter-based stent placement. Therefore, a reliable noninvasive diagnostic method for the evaluation of stented coronary arteries would be highly desirable. Our aim was to evaluate the diagnostic accuracy of high-resolution 64-slice computed tomography (64SCT) in a pilot study for the assessment of the lumen of coronary artery stents. MATERIALS AND METHODS: Twenty-five patients underwent 64SCT of the coronary arteries and quantitative x-ray coronary angiography (QCA) after coronary artery stent placement. 64SCT coronary angiography was performed with the following parameters: spatial resolution = 0.4 x 0.4 x 0.4 mm; temporal resolution = 83-165 milliseconds; contrast agent = 80 mL at a flow rate of 5 mL/second; retrospective electrocardiogram gating. The 64SCT scans were evaluated for image quality and for the presence of significant in-stent and peri-stent (proximal and distal) stenoses. Determinations were made of the sensitivity, specificity, diagnostic accuracy, and positive and negative predictive values (PPV and NPV) of 64SCT for the detection or exclusion of stenoses. RESULTS: A total of 46 stents were evaluated, of which 45 (98%) were of diagnostic image quality. Significant in-stent restenosis or occlusion was detected on QCA in 8/45 cases (>/=50% stenosis = 6; occlusion = 2). The sensitivity, specificity, accuracy, PPV, and NPV of 64SCT for the detection of significant in-stent disease was 75%, 92%, 89%, 67%, and 94%, respectively. Both occluded coronary artery stents were correctly identified. The sensitivity, specificity, and accuracy values of 64SCT for the detection of significant proximal peri-stent stenoses were 75%, 95%, and 93%, respectively, whereas the values for detection of significant distal peri-stent stenoses were 67%, 85%, and 84%, respectively. CONCLUSION: The high spatial and temporal resolution of 64SCT may permit improved assessment of stent occlusion and peri-stent disease, although detection of in-stent stenosis remains difficult.

Adult↗

Cardiac steady-state free precession CINE magnetic resonance imaging at 3.0 tesla: impact of parallel imaging acceleration on volumetric accuracy and signal parameters.

OBJECTIVES: We sought to evaluate the impact of 3.0 T on accelerated CINE steady-state free precession (SSFP) regarding signal parameters and its volumetric accuracy. MATERIAL AND METHODS: Ten individuals underwent cardiac CINE imaging at 1.5 T and 3.0 T using standard single-slice CINE and multislice TSENSE-accelerated CINE (5 slices/breath-hold) with 4-fold acceleration. Data were evaluated for left ventricular volumetric parameters (EDV, ESV, and EF) as well as for SNR and CNR. Phantom based data allowed for g-factor evaluation for estimation of noise levels for accelerated data sets. Volumetric results and signal parameters were compared with results of single-slice CINE SSFP at 1.5 T as standard of reference (SOR). RESULTS: Single-slice CINE at 3.0 T showed a approximately 90% increase in CNR compared with the SOR (P < 0.001). At 3.0 T, TSENSE CINE showed a less pronounced estimated loss in CNR (-58 +/- 6%) compared with single-slice CINE than at 1.5 T (-71 +/- 2%). 3.0 T TSENSE CINE showed a 21 +/- 18% lower CNR than the nonaccelerated 1.5 T CINE (P < 0.05). EF results for all data sets did not show any significant error while for EDV some errors have been encountered. CONCLUSION: 3.0 T permits compensation for the high CNR loss, which accompanies the 4-fold TSENSE acceleration at 1.5 T and shows volumetric accuracy. The use of parallel imaging may help to alleviate SAR limitations at higher field strength.

Adult↗

Image quality, motion artifacts, and reconstruction timing of 64-slice coronary computed tomography angiography with 0.33-second rotation speed.

OBJECTIVES: We sought to evaluate the impact of patients' heart rate (HR) on coronary CTA image quality (IQ) and motion artifacts using a 64-slice scanner with 0.33/360 degrees rotation. MATERIALS AND METHODS: Coronary CTA data sets of 32 patients (HR 65 bpm to 75 bpm, n = 7) examined on a 64-slice scanner (Sensation 64, Siemens Medical Solutions, Forchheim, Germany) with 0.33s/360 degrees gantry rotation speed were analyzed. All patients had suspicion of coronary artery disease. Data acquisition was performed using 64 x 0.6-mm collimation, and contrast enhancement was provided by injection of 80 mL of iopromide (5 mL/s + NaCl). Images were reconstructed throughout the RR interval using half-scan and dual-segment reconstruction. IQ was rated by 2 observers using a 3-point scale from excellent (1) to nondiagnostic (3) for coronary segments. Quality was correlated to the HR, time point of optimal IQ analyzed, and the benefit of dual-segment reconstruction evaluated. RESULTS: Overall mean IQ was 1.31 +/- 0.32 for all HR, with IQ being 1.08 +/- 0.12 for HR 65 bpm 75 bpm (P = 0.0003). Dual-segment reconstruction did not significantly improve IQ in any HR group (P = NS). Mean IQ was significantly better for LAD than for RCA (P < 0.0001) and LCX (P < 0.01). A total of 3.5% (11/318) of coronary artery segments were rated nondiagnostic by at least one reader based on motion artifacts. Although in HR < 65 bpm, the best IQ was predominately in diastole (93%), in HR > 75 bpm, the best IQ shifted to systole in most cases (86%). CONCLUSIONS: Temporal resolution at 0.33-second rotation allows for diagnostic IQ within a wide range of HR using half-scan reconstruction. With increasing HR the time point of best IQ shifts from mid-diastole to systole.

Adult↗

Contrast bolus optimization for cardiac 16-slice computed tomography: comparison of contrast medium formulations containing 300 and 400 milligrams of iodine per milliliter.

OBJECTIVES: The aims of our study were to compare contrast injection protocols with contrast media containing 300 and 400 mg iodine per milliliter for optimal contrast enhancement in cardiac multidector row computed tomography (CT) and to evaluate the correlation of test bolus curve parameters with the final contrast density of the main bolus. MATERIALS AND METHODS: Sixty patients with known or suspected coronary artery disease were included in a prospective double-blind study. Patients were randomized to 2 groups. Group 1 received 83 mL of a contrast medium (CM) containing 300 mg of iodine (Iomeron 300, Bracco Imaging SpA, Milan, Italy) at a flow rate of 3.3 mL/s, whereas group 2 received 63 mL of the same agent containing 400 mg of iodine (Iomeron 400) at a flow rate of 2.5 mL/s. The test bolus volumes were 20 mL and 15 mL, respectively. Imaging was performed using a 16-slice CT system (16DCT; Somatom Sensation 16, Siemens Medical Solutions, Forchheim, Germany). Contrast densities (Hounsfield Units [HU]) were determined in the cardiac chambers and in the main coronary arteries. The peak density and area under the curve of the test bolus were calculated for each patient. RESULTS: The mean contrast densities of the coronary arteries were 259.1 +/- 46.7 HU for group 1 and 251.6 +/- 51.0 HU, for group 2. No noteworthy differences between groups were noted for density measurements in the cardiac chambers or for the ratio of right-to-left ventricle density. Whereas a positive correlation was noted for both groups between the area under the curve of the test bolus and the mean density of the main bolus, a positive correlation between peak density of the test bolus and mean density of the main bolus was noted only for group 1. CONCLUSION: Equivalent homogenous enhancement of the ventricular cavities and coronary arteries to that obtained using a CM with standard iodine concentration (Iomeron 300) can be achieved with lower overall volumes of administered CM and reduced injection flow rates when a CM with high iodine concentration (Iomeron 400) is used.

Adult↗

Clinical value of MDCT in the diagnosis of coronary artery disease in patients with a low pretest likelihood of significant disease.

OBJECTIVE: The aim of this study was to evaluate the clinical value of MDCT in the diagnosis of coronary artery disease in a population having a low pretest likelihood of significant disease. SUBJECTS AND METHODS: Sixty-four patients with suspected coronary artery disease and a low pretest likelihood of significant disease according to the criteria of the American Heart Association underwent both MDCT of the heart and quantitative conventional coronary angiography (QCA). MDCT examinations were performed on a 16-MDCT scanner. CT data sets were evaluated on a per-patient basis and a per-segment basis and were classified as indicating no disease, nonsignificant disease (stenoses </= 50%), or significant disease (stenoses > 50%). Sensitivity, specificity, negative predictive value (NPV), and positive predictive value (PPV) of 16-MDCT in the detection or exclusion of significant and nonsignificant coronary artery disease were evaluated on both per-patient and per-segment bases. RESULTS: Regarding the success rate of 16-MDCT, 94% (60/64) of patients and 92% (388/420) of vessel segments were of sufficient quality for diagnosis. In the remaining 60 patients evaluated, QCA revealed significant coronary artery disease, nonsignificant disease, and no disease in 8.3% (5/60), 75.0% (45/60), and 16.7% (10/60) of cases, respectively, on a per-patient basis, and in 1.3% (5/388), 23.2% (90/388), and 75.5% (293/388) of cases, respectively, on a per-segment basis. The sensitivity, specificity, NPV, and PPV of 16-MDCT for the detection of significant coronary artery disease were 80.0%, 94.5%, 98.1%, and 57.1%, respectively, on a per-patient basis, and 80.0%, 99.2%, 99.7%, and 57.1% on a per-segment basis. CONCLUSION: In a population having a low pretest likelihood of significant coronary artery disease, 16-MDCT shows a moderate to high sensitivity and high NPV for the detection or exclusion of significant disease, but has a somewhat reduced PPV compared with QCA.

Adult↗

Accuracy of 64-MDCT in the diagnosis of ischemic heart disease.

OBJECTIVE: The aim of this study was to evaluate the potential clinical value of a new generation of 64-MDCT systems with that of invasive coronary angiography in the diagnosis of coronary artery disease (CAD). SUBJECTS AND METHODS: Seventy-two consecutive patients with known or suspected CAD underwent both 64-MDCT and quantitative coronary angiography (QCA). A CT system with acquisition of 64 slices per gantry rotation was used with a spatial resolution of 0.4 x 0.4 x 0.4 mm and a gantry rotation time of 330 milliseconds. Sensitivity, specificity, and diagnostic accuracy of 64-MDCT in the detection or exclusion of CAD were evaluated on both a per patient and a per segment basis. RESULTS: Sixty-eight of 72 coronary CT angiograms (CTAs) (94%) were of diagnostic image quality. QCA showed significant CAD (i.e., one or more stenoses in > 50%) in 57% (39/68) and nonsignificant disease or healthy CTAs in 43% (29/68) of the patients. Sensitivity, specificity, and the negative predictive value (NPV) of 64-MDCT per patient were 97%, 79%, and 96%, respectively. Per segment, 923 of 1,020 coronary artery segments were assessable (90%). For the detection of stenoses of more than 50% and more than 75% per segment, 64-MDCT showed a sensitivity of 82% and 86%, respectively. Per segment, specificity and NPV were as high as 95% and 97%, respectively. CONCLUSION: In clinical routine, coronary CTA will primarily be used for risk stratification on a per patient basis. In the present study, coronary 64-MDCT showed a high diagnostic accuracy on both per patient and per segment analyses.

Adult↗

Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography: a comparative study with quantitative coronary angiography and intravascular ultrasound.

OBJECTIVES: The aim of the present study was to determine the diagnostic accuracy of 64-slice computed tomography (CT) to identify and quantify atherosclerotic coronary lesions in comparison with catheter-based angiography and intravascular ultrasound (IVUS). BACKGROUND: Currently, the ability of multislice CT to quantify the degree of coronary artery stenosis and dimensions of coronary plaques has not been evaluated. METHODS: We included 59 patients scheduled for coronary angiography due to stable angina pectoris. A contrast-enhanced 64-slice CT (Senation 64, Siemens Medical Solutions, Forchheim, Germany) was performed before the invasive angiogram. In a subset of 18 patients, IVUS of 32 vessels was part of the catheterization procedure. RESULTS: In 55 of 59 patients, 64-slice CT enabled the visualization of the entire coronary tree with diagnostic image quality (American Heart Association 15-segment model). The overall correlation between the degree of stenosis detected by quantitative coronary angiography compared with 64-slice CT was r = 0.54. Sensitivity for the detection of stenosis <50%, stenosis >50%, and stenosis >75% was 79%, 73%, and 80%, respectively, and specificity was 97%. In comparison with IVUS, 46 of 55 (84%) lesions were identified correctly. The mean plaque areas and the percentage of vessel obstruction measured by IVUS and 64-slice CT were 8.1 mm2 versus 7.3 mm2 (p < 0.03, r = 0.73) and 50.4% versus 41.1% (p < 0.001, r = 0.61), respectively. CONCLUSIONS: Contrast-enhanced 64-slice CT is a clinically robust modality that allows the identification of proximal coronary lesions with excellent accuracy. Measurements of plaque and lumen areas derived by CT correlated well with IVUS. A major limitation is the insufficient ability of CT to exactly quantify the degree of stenosis.

Aged↗

Pulmonary arterial hypertension: diagnosis with fast perfusion MR imaging and high-spatial-resolution MR angiography--preliminary experience.

PURPOSE: To determine prospectively the accuracy of a magnetic resonance (MR) perfusion imaging and MR angiography protocol for differentiation of chronic thromboembolic pulmonary arterial hypertension (CTEPH) and primary pulmonary hypertension (PPH) by using parallel acquisition techniques. MATERIALS AND METHODS: The study was approved by the institution's internal review board, and all patients gave written consent prior to participation. A total of 29 patients (16 women; mean age, 54 years +/- 17 [+/- standard deviation]; 13 men; mean age, 57 years +/- 15) with known pulmonary hypertension were examined with a 1.5-T MR imager. MR perfusion imaging (temporal resolution, 1.1 seconds per phase) and MR angiography (matrix, 512; voxel size, 1.0 x 0.7 x 1.6 mm) were performed with parallel acquisition techniques. Dynamic perfusion images and reformatted three-dimensional MR angiograms were analyzed for occlusive and nonocclusive changes of the pulmonary arteries, including perfusion defects, caliber irregularities, and intravascular thrombi. MR perfusion imaging results were compared with those of radionuclide perfusion scintigraphy, and MR angiography results were compared with those of digital subtraction angiography (DSA) and/or contrast material-enhanced multi-detector row computed tomography (CT). Sensitivity, specificity, and diagnostic accuracy of MR perfusion imaging and MR angiography were calculated. Receiver operator characteristic analyses were performed to compare the diagnostic value of MR angiography, MR perfusion imaging, and both modalities combined. For MR angiography and MR perfusion imaging, kappa values were used to assess interobserver agreement. RESULTS: A correct diagnosis was made in 26 (90%) of 29 patients by using this comprehensive MR imaging protocol. Results of MR perfusion imaging demonstrated 79% agreement (ie, identical diagnosis on a per-patient basis) with those of perfusion scintigraphy, and results of MR angiography demonstrated 86% agreement with those of DSA and/or CT angiography. Interobserver agreement was good for both MR perfusion imaging and MR angiography (kappa = 0.63 and 0.70, respectively). CONCLUSION: The combination of fast MR perfusion imaging and high-spatial-resolution MR angiography with parallel acquisition techniques enables the differentiation of PPH from CTEPH with high accuracy.

Diagnosis, Differential↗