Search PubMed⌕ Search

Biomedical subjects

Klaus Scheffler

Publications and source records attributed to Klaus Scheffler.

18 recordsLinked to original sources

A computational ontology framework for the synthesis of multi-level pathology reports from brain MRI scans.

BackgroundConvolutional neural network (CNN) based volumetry of MRI data can help differentiate Alzheimer's disease (AD) and the behavioral variant of frontotemporal dementia (bvFTD) as causes of cognitive decline and dementia. However, existing CNN-based MRI volumetry tools lack a structured hierarchical representation of brain anatomy, which would allow for aggregating regional pathological information and automated computational inference.ObjectiveDevelop a computational ontology pipeline for quantifying hierarchical pathological abnormalities and visualize summary charts for brain atrophy findings, aiding differential diagnosis.MethodsUsing FastSurfer, we segmented brain regions and measured volume and cortical thickness from MRI scans pooled across multiple cohorts (N = 3433; ADNI, AIBL, DELCODE, DESCRIBE, EDSD, and NIFD), including healthy controls, prodromal and clinical AD cases, and bvFTD cases. Employing the Web Ontology Language (OWL), we built a semantic model encoding hierarchical anatomical information. Additionally, we created summary visualizations based on sunburst plots for visual inspection of the information stored in the ontology.ResultsOur computational framework dynamically estimated and aggregated regional pathological deviations across different levels of neuroanatomy abstraction. The disease similarity index derived from the volumetric and cortical thickness deviations achieved an AUC of 0.88 for separating AD and bvFTD, which was also reflected by distinct atrophy profile visualizations.ConclusionsThe proposed automated pipeline facilitates visual comparison of atrophy profiles across various disease types and stages. It provides a generalizable computational framework for summarizing pathologic findings, potentially enhancing the physicians' ability to evaluate brain pathologies robustly and interpretably.

Humans↗

Principles and applications of balanced SSFP techniques.

During the past 5 years balanced steady-state free precession (SSFP) has become increasingly important for diagnostic and functional imaging. Balanced SSFP is characterized by two unique features: it offers a very high signal-to noise ratio and a T2/T1-weighted image contrast. This article focuses on the physical principles, on the signal formation, and on the resulting properties of balanced SSFP. Mechanisms for contrast modification, recent clinical application, and potential extensions of this technique are discussed.

Angiography↗

Is TrueFISP a gradient-echo or a spin-echo sequence?

It is commonly accepted that TrueFISP (balanced FFE, FIESTA) belongs to the class of gradient-echo (GRE) sequences. GRE sequences are sensitive to dephasing effects of the transverse magnetization between the excitation pulse and echo acquisition, and phase coherence is only established directly after and before excitation pulses. However, an analysis of the phase evolution of transverse magnetization in a TrueFISP experiment shows very close similarities to the echo formation of a spin-echo (SE) experiment. If dephasing between excitation pulses is below +/-pi, TrueFISP exhibits a nearly complete refocusing of transverse magnetization at TE = TR/2. Only signals acquired before and after TR/2 show an additional T*2 sensitivity.

Magnetic Resonance Imaging↗

Multiecho sequences with variable refocusing flip angles: optimization of signal behavior using smooth transitions between pseudo steady states (TRAPS).

A variation of the rapid acquisition with relaxation enhancement (RARE) sequence (also called turbo spin-echo (TSE) or fast spin-echo (FSE)) is presented. This technique uses variable flip angles along the echo train such that magnetization is initially prepared into the static pseudo steady state (PSS) for a low refocusing flip angle (alpha < 180 degrees ). It is shown that after such a preparation, magnetization will always stay very close to the static PSS even after significant variation of the subsequent refocusing flip angles. This allows the design of TSE sequences in which high refocusing flip angles yielding 100% of the attainable signal are applied only for the important echoes encoding for the center of k-space. It is demonstrated that a reduction of the RF power (RFP) by a factor of 2.5-6 can be achieved without any loss in signal intensity. The contribution of stimulated-echo pathways leads to a reduction of the effective TE by a factor f(t), which for typical implementations is on the order of 0.5-0.8. This allows the use of longer echo readout times, and thus longer echo trains, for acquiring images with a given T(2) contrast.

Computer Simulation↗

On the transient phase of balanced SSFP sequences.

The signal intensity of balanced steady-state free precession (SSFP) imaging is a function of the proton density, T(1), T(2), flip angle (alpha), and repetition time (TR). The steady-state signal intensity that is established after about 5*T(1)/TR can be described analytically. The transient phase or the approach of the echo amplitudes to the steady state is an exponential decay from the initial amplitude after the first excitation pulse to the steady-state signal. An analytical expression of the decay rate of this transient phase is presented that is based on a simple analysis derived from the Bloch equations. The decay rate is a weighted average of the T(1) and T(2) relaxation times, where the weighting is determined by the flip angle of the excitation pulses. Thus, balanced SSFP imaging during the transient phase can provide various contrasts depending on the flip angle and the number of excitation pulses applied before the acquisition of the central k-space line. In addition, transient imaging of hyperpolarized nuclei, such as (3)He, (129)Xe, or (13)C, can be optimized according to their T(1) and T(2) relaxation times.

Humans↗

Detection of the non-steroidal anti-inflammatory drug niflumic acid in humans: a combined 19F-MRS in vivo and in vitro study.

This study describes for the first time results of a (19)F-MRS study on humans exposed to the fluorinated non-steroidal anti-inflammatory drug niflumic acid. The accumulation and elimination of this commercially available selective prostaglandin synthase inhibitor is studied after an oral bolus in the human liver, in blood plasma and in urine samples. The in vivo spectra of the liver display two resonances with a similar increase in signal intensity during the investigation period of 240 min. One resonance refers to the parent compound niflumic acid (P), whereas the second resonance corresponds to a metabolite (M1) formed by the biotransformation by liver enzymes. The spectroscopic comparison with model compounds suggests 4'-hydroxyniflumic acid as the metabolite. During the entire experiment the concentration ratios of these resonances (P/M1) ranged between 0.7 and 0.9, indicating a high metabolite concentration most probably due to an efficient first pass metabolism. Both resonances (P, M1) were observed in the in vitro study of the blood plasma samples after plasma protein denaturation. However, in comparison to the liver spectra, the amount of the metabolite M1 is very small with a P/M1-ratio of 36.6 after 90 min and 16.1 after the end of measurement. This finding suggests an efficient biliary excretion of the metabolite M1, which bypasses the blood circulation system. Both resonances are also identified in the native urine samples. The signal intensity of the parent compound dominates the spectra of all urine samples, whereas the signal intensity of M1 increases slowly reaching a similar value to the parent compound P at the end of the measurement. This observation demonstrates an effective renal elimination of niflumic acid and suggests the existence of an enterohepatic circuit with a re-entry mechanism for the biliary excreted metabolite M1. In the urine spectra, an additional metabolite M2 is found. This resonance exhibits a low but constant signal intensity. The chemical origin of this metabolite is unclear.

Administration, Oral↗

Invasive and non-invasive evaluation of spontaneous arteriogenesis in a novel porcine model for peripheral arterial obstructive disease.

Our current knowledge regarding the efficacy of factors stimulating collateral artery growth in the peripheral circulation primarily stems from models in small animals. However, experimental models in large sized animals are a prerequisite for extrapolation of growth factor therapy to patients with peripheral atherosclerotic obstructive disease. Therefore, we have developed a novel porcine femoral artery ligation model using non-invasive and invasive evaluation techniques. In 12 young farm pigs and nine older minipigs, a ligation of the superficial femoral artery was performed. Using an intra-arterial catheter, phosphate buffered saline (PBS) was administered with a first-pass over the collateral vascular bed. Directly after ligation as well as after 2 weeks of continuous infusion of PBS, perfusion of the leg was measured using various flow and pressure parameters. Using a pump driven extracorporal system, collateral conductance was determined under maximal vasodilatation. Conductance decreased after acute ligation to similar levels in both young farm pigs as well as the older minipigs (both 9.3% of normal perfusion) and recovered after 2 weeks to a higher value in farm pigs compared with minipigs (22.4 vs. 12.7% of normal; P<0.05). Angiography using both X-ray and magnetic resonance imaging was performed to visualize the formed collateral arteries. To the best of our knowledge this is the first in vivo pig model for hemodynamic assessment of growth of collateral arteries in the peripheral circulation, that is suitable for evaluation of arteriogenic effects of growth factors or genes.

Angiography↗

Neural processing of auditory looming in the human brain.

Acoustic intensity change, along with interaural, spectral, and reverberation information, is an important cue for the perception of auditory motion. Approaching sound sources produce increases in intensity, and receding sound sources produce corresponding decreases. Human listeners typically overestimate increasing compared to equivalent decreasing sound intensity and underestimate the time to contact of approaching sound sources. These characteristics could provide a selective advantage by increasing the margin of safety for response to looming objects. Here, we used dynamic intensity and functional magnetic resonance imaging to examine the neural underpinnings of the perceptual priority for rising intensity. We found that, consistent with activation by horizontal and vertical auditory apparent motion paradigms, rising and falling intensity activated the right temporal plane more than constant intensity. Rising compared to falling intensity activated a distributed neural network subserving space recognition, auditory motion perception, and attention and comprising the superior temporal sulci and the middle temporal gyri, the right temporoparietal junction, the right motor and premotor cortices, the left cerebellar cortex, and a circumscribed region in the midbrain. This anisotropic processing of acoustic intensity change may reflect the salience of rising intensity produced by looming sources in natural environments.

Adult↗

Dynamic contrast enhancement of paragangliomas of the head and neck: evaluation with time-resolved 2D MR projection angiography.

Our objective was to evaluate tumor hemodynamics of paragangliomas of the head and neck. A 2D magnetic resonance projection angiography (MRPA) protocol was developed. Six patients with histologically proven paragangliomas were included in the study. The sequence protocol and data post-processing procedure were optimized in view of a high temporal resolution and maximum contrast-to-noise ratio. Image-time series of two freely orientated slabs could be obtained. Correlation analysis was performed to generate selective arterial and venous weighted angiographic images. Glomus tumors showed a rapid and intense homogeneous enhancement following the intravenous administration of contrast material. The smallest tumors investigated measured 10 mm and could be visualized clearly. Time-resolved analysis of the tumor enhancement revealed an early bolus arrival within the vascular bed of the tumor and prolonged incomplete washout indicating blood pooling. The dynamic contrast enhancement of glomus tumors can be evaluated non-invasively with MRPA providing a high temporal resolution and high image quality. The characteristic contrast enhancement of glomus tumors can be helpful in the diagnostic workup of lesions that may mimic glomus tumors.

Carotid Body Tumor↗

Spatiotemporal pattern of neural processing in the human auditory cortex.

The principles that the auditory cortex uses to decipher a stream of acoustic information have remained elusive. Neural responses in the animal auditory cortex can be broadly classified into transient and sustained activity. We examined the existence of similar principles in the human brain. Sound-evoked, blood oxygen level-dependent signal response was decomposed temporally into independent transient and sustained constituents, which predominated in different portions-core and belt-of the auditory cortex. Converging with unit recordings, our data suggest that this spatiotemporal pattern in the auditory cortex may represent a fundamental principle of analyzing sound information.

Acoustic Stimulation↗

fMRI of the auditory cortex in patients with unilateral carotid artery steno-occlusive disease.

PURPOSE: To examine whether an internal carotid artery (ICA) steno-occlusive disease leads to a reduced blood oxygenation level dependent (BOLD)-signal change due to a decreased vasodilatory reserve capacity. MATERIALS AND METHODS: Patients suffering from unilateral ICA stenosis or occlusion were examined using functional magnetic resonance imaging (fMRI) of the auditory cortex with a bilateral stimulation applying a pulsed 1000 Hz sine-tone. RESULTS: Compared to control subjects, who showed symmetric bilateral BOLD-responses within the auditory cortex, the ICA patients revealed either a normal bilateral cortical activation pattern or a reduced cortical activation on the steno-occluded side. This latter decrease of BOLD-signal change might indicate a depressed vasomotor reserve capacity. The observed coincidence between this asymmetric reduction in BOLD-signal and ischemic borderzone lesions on the affected side in this subgroup of patients strongly supports this assumption. CONCLUSION: This study shows that fMRI of the auditory cortex appears to have clinical merit in the workup of cerebrovascular conditions.

Acoustic Stimulation↗

Are TrueFISP images T2/T1-weighted?

Images acquired using the TrueFISP technique (true fast imaging with steady-state precession) are generally believed to exhibit T(2)/T(1)-weighting. In this study, it is demonstrated that with the widely used half-flip-angle preparation scheme, approaching the steady state requires a time length comparable to the scan time such that the transient-state response may dominate the TrueFISP image contrast. Two-dimensional images of the human brain were obtained using various phase-encoding matrices to investigate the transient-state signal behavior. Contrast between gray and white matter was found to change significantly from proton-density- to T(2)/T(1)-weighted as the phase-encoding matrix size increased, which was in good agreement with theoretical predictions. It is concluded that TrueFISP images in general exhibit T(2)/T(1)-contrast, but should be more appropriately regarded as exhibiting a transient-state combination of proton-density and T(2)/T(1) contrast under particular imaging conditions. Interpretation of tissue characteristics from TrueFISP images in clinical practice thus needs to be exercised with caution.

Brain↗

Optimization of signal behavior in the transition to driven equilibrium in steady-state free precession sequences.

A new technique to avoid the initial signal fluctuations in steady-state free precession (SSFP)-sequences, such as trueFISP, FIESTA, and refocused FFE, is presented. The "transition into driven equilibrium" (TIDE) sequence uses modified flip angles over the initialization phase of a SSFP experiment, which not only avoids image artifacts but also improves the signal-to-noise ratio (SNR) and contrast behavior compared to conventional approaches. TIDE is demonstrated to be robust against variations of T(1) and T(2), and leads to a monotonous signal evolution for off-resonance spins. The basic principles can also be applied repetitively to optimize continuous 3D acquisitions.

Head↗

Single-breathhold 3D-trueFISP cine cardiac imaging.

Cardiac MRI function measurements are typically based on multiple breathhold 2D sequences to acquire images of the entire heart. In the present study, the feasibility of a cine 3D TrueFISP technique in which several complete volumetric measurements may be obtained during a single breathhold is demonstrated. In contrast to 3D FLASH, the TrueFISP sequence offers an excellent contrast between the myocardium and the intraventricular cavity without the use of contrast agent. An ECG-gated 3D cine TrueFISP sequence was implemented with a repetition time of 2.4-2.8 ms, which allows imaging of the complete heart within a single breathhold throughout 20-46 heartbeats with a 3D frame rate of 8-13 volumes per cardiac cycle and a spatial resolution of about 1.5 x 3.5 x 3.5 mm(3). Breathhold volumetric cine imaging with the 3D TrueFISP technique holds promise for rapid and accurate evaluation of the cardiac regional wall motion and the calculation of cardiac volume and ejection fraction.

Artifacts↗

Homogeneous preparation encoding (HoPE) in multislice imaging.

Fast magnetization preparation techniques acquire a series of echoes after a single magnetization preparation. If these echoes are acquired from different slices using a multislice technique the change in the preparation state of the echoes due to relaxation effects leads to different contrast modification for each slice. Encoding different preparation states along the phase-encoding direction of each slice instead of acquiring each slice in a different preparation state is introduced as a general concept to obtain images of identical contrast and point-spread function. This can be realized either by cycling the slice excitation order several times over the total number of repetitions or by moving the point of time at which the preparation is applied within each repetition. One possible application of this method is chemical shift selective fat saturation imaging. A homogeneous fat suppression across a multislice volume could be achieved using a FLASH sequence at a repetition time of TR = 145 ms, including a single fat saturation preparation. Conventional fat saturated spin-echo imaging at any TR can be accelerated significantly by reducing the number of applied preparations per repetition. A further application of the homogeneous preparation encoding (HoPE) method is described that encodes the spatial self-saturation of the multislice excitation order homogeneously in all slices. Only a reduced number of slices of the total volume are excited in each repetition and the slice excitation order is continuously moved along the imaging volume. This method is applied for time of flight (TOF) imaging. Using a TONE-like series of flip angles for the slice excitations of each repetition homogeneous TOF images can be obtained on the basis of a multislice acquisition.

Abdomen↗

Signal behavior in continuously ramped 2D TrueFISP for whole-body imaging.

A fast and robust imaging technique was developed based on a single-slice TrueFISP acquisition using a slice excitation frequency that is incremented, or spatially "ramped," with each repetition. The short acquisition time of single slices allows artifact-free imaging during free breathing, which demonstrates the potential use of this technique for whole-body screening. Overlapping positioning of consecutively acquired slices was used to provide gapless volume coverage in free-breathing measurements. The image contrast of ramped TrueFISP was analyzed in detail using simulations and experiments. A high ramp speed results in an increased overall signal intensity and in a modification of the known T(2)/T(1) contrast towards a proton density-weighted contrast. A further increase in imaging speed is achieved with z-interleaved phase-encoding trajectories based on weighted transitions between adjacent views.

Contrast Media↗

Amplitopicity of the human auditory cortex: an fMRI study.

Whereas specialized frequency-encoding patterns in the human auditory cortex are generally accepted, termed tonotopicity, a similar principle of intensity encoding--amplitopicity--is debated controversially. This functional magnetic resonance imaging study describes the relationship of the activation volume and the spatial distribution of activated clusters under different sound pressure levels (SPL) across the temporal plane including the transverse temporal gyrus (TTG). Nine healthy subjects with no hearing deficiencies were investigated using an echo-planar imaging technique at 1.5 T. A boxcar stimulation paradigm was applied with a 5-Hz pulsed sine tone of 1000 Hz frequency at three SPLs of 70, 82, and 90 dB. Linear cross-correlation analysis (correlation coefficient > 0.3 corresponding to P < 0.08) of the functional data set revealed bilateral BOLD response within the auditory cortex of the nine subjects with moderate increase of activation volume for higher sound pressure levels. With increasing sound pressure a two-dimensional drift of cortical activation was observed (a) from the ventral to the dorsal edge and (b) from lateral to medial parts of TTG. This latero-medial drift therefore mimics the well-accepted principle of tonotopy for frequency-encoding neurons. This study demonstrates the existence of an amplitopic pattern of intensity-encoding neuronal clusters that in part resembles the tonotopic distribution of frequency-encoding neurons. This finding has to be integrated into the understanding of the auditory organization for the interpretation of higher auditory functions such as sound perception or speech.

Acoustic Stimulation↗