Search PubMed⌕ Search

Biomedical subjects

Klaus J Klose

Publications and source records attributed to Klaus J Klose.

10 recordsLinked to original sources

The impact of the dosage of intravenous gadolinium-chelates on the vascular signal intensity in MR angiography.

To show the effects of different concentrations of contrast agent on signal time curves and image contrast of abdominal aorta, vena cava and portal vein in comparison to each other as well as liver and spleen. Imaging was carried out in a 1.0 Tesla clinical scanner. Sixty patients were prospectively included and divided into three contrast agent (Gd-DTPA) dosage groups (0.1 mmol/kg, 0.2 mmol/kg and 0.3 mmol/kg). All patients were scanned using a time-resolved 3D FLASH sequence (58 phases) with a 3.75 second acquisition time per phase. Signal time curves and image contrast levels were evaluated. No significant differences were found for the maximum signal enhancement between the groups in the investigated vessels. Image masking, the subtraction of the baseline images, resulted in a substantial improvement in image contrast. However, statistically significant differences between the contrast agent dosage groups could only be found for vena cava and liver. Vessel conspicuity is not significantly improved with an increase of contrast agent dose. However, an increase in contrast agent dosage increases vessel contrast. Our findings suggest that a single dose single station investigation seems to be sufficient for high quality abdominal MRA.

Adult↗

How to successfully implement E-learning for both students and teachers.

RATIONALE AND OBJECTIVES: Electronic learning (e-learning) may provide a means to enhance learning efficacy. However, introduction of e-learning often fails. We describe a strategy of how an e-learning curriculum was successfully implemented. MATERIALS AND METHODS: The curriculum was designed based on published evidence. It consists of self-directed learning, an online discussion forum, and discussion rounds. The e-content in nuclear medicine and radiotherapy was produced by the k-MED team of medical authors, web designers, and psychologists. The online courses were delivered via a dedicated learning management system. The e-content for diagnostic radiology and physics was provided as PDF/HTML script by the respective teachers who objected to participate in the k-MED project. The exam was taken online. Online evaluation of the curriculum by the students was taken at the end of the course. RESULTS: The new curriculum proved very effective. The time for the preparation for the clinical part of the radiology course could be reduced from 4 to 2 weeks. The students particularly enjoyed the self-directed learning. Although the material provided by k-MED received 90%-99% positive scores, the HTML and PDF scripts scored worse (13%-67% positive ratings). The positive results of the evaluation convinced the teachers responsible for physics and diagnostic radiology to participate in k-MED. CONCLUSIONS: As our example shows, new e-learning curricula can successfully be introduced. The strategy of implementation should be based on the existing evidence from the literature. The new curriculum helped to increase the efficacy of teaching and save time as the duration of the respective part of the course could be reduced by half.

Computer-Assisted Instruction↗

Right ventricular cardiac myxoma. Diagnostic usefulness of cardiac magnetic resonance imaging.

BACKGROUND: Cardiac myxomas are the most common type of cardiac tumors. About 75-85% of cardiac myxomas originate in the left atrium, 15-20% in the right atrium. Most myxomas arise from the interatrial septum adjacent to the fossa ovalis. Only 3-4% are found in the left and right ventricle each. Although myxomas are histologically benign, they may be fatal because of their strategic position. CASE STUDY: The authors report on a 24-year-old patient with stabbing thoracic pain and dyspnea due to pulmonary thromboembolism that was caused by an atypically localized myxoma at the right ventricular apex originating from the interventricular septum. The diagnosis was based on cardiac magnetic resonance (CMR) imaging. Superior to echocardiography, CMR could strengthen the diagnostic accuracy by additional information on tissue characterization using different imaging sequences. Typically for cardiac myxomas, contrast enhancement was moderate and delayed enhancement was found in the outer circumferential tumor margins only. CONCLUSION: High spatial resolution and multiplane imaging combined with different acquisition patterns of CMR achieve a global view of the heart that seems to be useful for diagnosing cardiac tumorous masses.

Adult↗

[MR-Imaging of lower leg muscle perfusion].

PURPOSE: This article describes the potential of dynamic contrast- enhanced magnetic resonance tomography (DCE-MRT) for the visualization and quantification of blood flow of lower leg muscles at rest and after individually adjusted muscular exercise. PATIENTS AND METHODS: Five cases were chosen to exemplify the qualitative and semi-quantitative blood flow evaluation in the lower leg muscles. The crural muscle state was determined with an isometric maximal strength measurement from a female patient with peripheral arterial occlusive disease (pAVK), a male patient with coronary heart disease (KHK) without clinical signs of a pAVK, a volunteer with sufficient physical activity in accordance with the Freiburg Questionnaire of Physical Activity and two professional athletes. After calibration of the plantarflexion ergometer MR-PEDALO (Figures 2a and 2b) for the execution of auxotonic muscle work a 1- minute alternating foot extension and flexion exercise on MRPEDALO was performed in the MR machine. Instead of the lower leg splint shown in Figures 2a and 2b the MR coil fits exactly in MR-PEDALO used for DCE-MRT. Mechanical work performed during the 1-minute exercise ranged from 52 watt seconds (Ws) to 244 Ws (0.65 W to 4.07 W), indicating similar interindividual work loads in relation to the individual maximum isometric strength. DCE-MRT was performed at rest and immediately after auxotonic exercise test (T1w 2DFLASH- GE sequence with TR/TE/alpha: 100 ms/6 ms/70 degrees; field of view: 400; matrix: 81 x 256; slice thickness: 10 mm; acquisitions: 73 at 8.3 s each; total examination time: 9.24 min; bolus application of Magnevist, Schering, 0.02 ml/kg kg, 20 ml bolus NaCl, flow 2 ml/s, 22G cannula in a cubital vein). Signal intensity (SI) curves were analyzed with DynaVision (MeVis gGmbH, Bremen, Germany). RESULTS: Measuring peripheral blood flow needs appropriate muscular stress tests. The SI-curves of the region of interest (ROI) representing the peroneus, tibialis anterior and gastrocnemius muscle run almost parallel at rest. Workloads between 52 Ws and 244 Ws (0.65 W and 4.07 W), similar in relation to the individual maximum isometric strength, induce distinctive changes of the upslope, wash-in, peak and washout of SI-curves preferably for the peroneus muscle and less predominant also for the tibialis anterior muscle and gastrocnemius muscle respectively. The first case, a 55-year-old female patient with peripheral arterial occlusive disease (pAVK) stage Fontaine IIb before (Figure 3a) and after (Figure 3b) percutaneous transluminal angioplasty (PTA) of a right femoral artery stenosis shows after interventional treatment a rapid post-exercise SI-increase in the peroneus muscle. The steeper SI-curve indicates a better contrast medium inflow due to an improved perfusion. The second case, a 65-year-old man suffering from coronary heart disease without clinical signs of pAVK (Figure 4) exercised with a workload of 92 Ws. After stress test the ROI for the peroneus muscle shows a clear intensity increase. After exercise the SI-curve for the tibialis anterior muscle shows a similar, but less predominant change while the shape of the SI-curve of the gastrocnemius muscle remains mainly identical. A 23-year-old male person with average physical activity (Figure 5) performed DCE-MRT of the left lower leg after stress test with 172 Ws demonstrating a rapid signal increase in the peroneus muscle while the synergistic tibialis anterior muscle and antagonistic gastrocnemius muscle show a comparatively slow contrast-medium wash-in. A 26-year-old male athlete (Figure 6) exercised with 196 Ws showing a rapid contrast medium inflow in the peroneus muscle and initially also in the synergistic tibialis anterior muscle. A contrast-medium wash-out appears in both muscles, while the shape of the gastrocnemius muscle SI-curve remains substantially unchanged. A 26-year-old female athlete (Figure 7) exercised with 244 Ws. Post exercise SI-curves show a distinctive and rapid increase of contrast medium wash-in with a sharp peak particularly in the peroneus muscle and similarly in the tibialis anterior and gastrocnemius muscle. After exercise all SI-curves show a wash-out phase. CONCLUSION: SI-curves show relative increase in correlation with Time-to-Peak (TTP) decrease and Mean-Intensity to Time Ratio (MITR) increase indicating blood flow reserve mobilization after exercise. Individual muscle state seems to be linked to muscle recruitment and muscle coordination reflected by post-exercise SI-curves. The gastrocnemius muscle shows comparatively low SI-curve changes after muscular load test. Further methodological standardization and optimization of the stress test is mandatory to assure intra- and interindividual comparisons. Due to direct visualization and quantitative evaluation of the peripheral microcirculation DCE-MRT has a diagnostic potential for monitoring therapeutic response in peripheral circulation disorders and sports medicine.

Adult↗

18F-FDG PET, somatostatin receptor scintigraphy, and CT in metastatic medullary thyroid carcinoma: a clinical study and an analysis of the literature.

AIM: To determine the clinical potential of 2-[F]fluoro-2-deoxy-D-glucose positron emission tomography (F-FDG PET) in patients with medullary thyroid carcinoma (MTC), we compared it to computed tomography (CT), and somatostatin receptor scintigraphy (SRS). PATIENTS AND METHODS: Blinded evaluation of PET, CT and SRS images obtained from 26 patients with histologically proven metastatic MTC was done by nuclear medicine and radiology specialists. Sites of tumour involvement were classified as "sure" or "suspicious". The data were analysed in comparison to two different standards. Either those sites classified as "sure" by at least one of the methods were defined as the standard or those sites of involvement which were classified as "sure" by at least two methods. RESULTS: Dependent on the type of data analysis performed, PET was able to demonstrate 56.8%/80.6% of the tumour sites, CT showed 64.5%/79.6%, and SRS showed 47.5%/69.9% of the tumour sites. CONCLUSION: Overall, CT is similar or better than PET in our patients (dependent on the standard) while SRS is inferior to both other techniques. Our data are in agreement with publications that consider CT superior to PET in the diagnosis of metastatic MTC while other studies show superiority of PET. However, a combination of CT and PET seems to be the most appropriate non-invasive diagnostic approach in patients with MTC.

Adolescent↗

Pancreatic transplants: noninvasive evaluation with secretin-augmented mr pancreatography and MR perfusion measurements--preliminary results.

Feasibility of secretin-augmented magnetic resonance (MR) pancreatography and dynamic contrast material-enhanced MR measurements for evaluation of functional status of pancreatic allografts was determined by quantifying the excretion and perfusion of the grafts. Ten patients were included prospectively before pancreatic transplantation. Dynamic T2-weighted sequences after secretin stimulation and dynamic contrast-enhanced T1-weighted gradient-echo sequences were performed. Area under the curve and maximum signal intensity-to-time ratio were determined in selected regions of interest. Biochemical parameters, Doppler ultrasonography, and/or surgery were standards for final diagnosis. Patients with normal outcome (n = 7) produced 236 mL +/- 104 (standard deviation) of pancreatic juice, and patients with dysfunctional grafts (n = 3) produced 42 mL +/- 25. Area under the curve and maximum signal intensity-to-time ratio provided thresholds of 0.5 and 0.3, respectively, for distinction between functional and dysfunctional grafts. Secretin-augmented MR pancreatography combined with MR perfusion measurements may aid in differentiation between patients with and those without graft dysfunction.

Adult↗

Influence of somatostatin receptor scintigraphy and CT/MRI on the clinical management of patients with gastrointestinal neuroendocrine tumors: an analysis in 188 patients.

AIM: Many studies describe the sensitivities and specificities of computed tomography (CT), magnetic resonance imaging (MRI), and somatostatin receptor scintigraphy (SRS) in patients with gastrointestinal neuroendocrine tumors (GNT). We performed a study to evaluate the influence of these techniques on the therapeutic management of patients with advanced stages of GNT. PATIENTS AND METHODS: The results of either CT/MRI scans or SRS were reviewed by two independent observers who decided on the therapy of a patient. They then had to determine whether the results of the complementary imaging modality would change the decision. The study design was a matched cross-over study with two groups matching in respect to tumor type, imaging modality known first to the observer, and number of patients. For further analysis, patients were divided into three subgroups dependent on tumor stage (group 1, without metastases, group 2, liver metastases, group 3, recurrent disease/extrahepatic metastases). RESULTS: 188 patients were included into the study. If SRS was known to the observers first, CT/MRI changed the therapeutic management in 16.2, 13.9 and 11.4% of the patients (subgroups 1-3). SRS changed the therapeutic management in 13.5, 12.5 and 10.3%. Overall, CT/MRI would have changed the management in 13.3% and SRS in 11.7% of the patients. CONCLUSION: Though the patients studied mainly suffered from already advanced stages of the disease, all imaging techniques change the therapeutic management to a comparable extent. Our results support the importance of combined imaging in the management of patients with GNT.

Cross-Over Studies↗

Calibrated magnetic resonance hydrometry: an in vitro study.

PURPOSE: To demonstrate a quantitative approach to measuring fluid volumes with standard single shot RARE sequences. MATERIALS AND METHODS: In phantom experiments, magnetic resonance hydrometry (MRH), in combination with various calibration phantoms (5 mL up to 500 mL) as internal standards, was used to quantify fluid volumes. In total, 16 volume phantoms were investigated with six different calibration phantoms. In addition, noise correction was implemented to correct the quantification results and to avoid the influence of random noise in the image. RESULTS: All MR measurements show significant correlations of up to r = 0.99 (P <.05) with the real applied volume in the investigated phantoms. However, measurements of large volumes were more precise with large calibration phantoms. Noise reduction did not change the correlation between measured and real applied volumes, but did reduce the error of the measured volumes. Calibrated magnetic resonance hydrometry (cMRH) is able to quantify volumes of fluid fast and noninvasively. The volumes of the used calibration phantoms have to be at least in the order of magnitude of the volumes that are to be measured. CONCLUSION: In vitro, cMRH using a single-shot rapid acquisition with refocused echoes (ssRARE) sequence and calibration phantoms is a fast and accurate method of quantifying steady amounts of fluid.

Algorithms↗

Guidance of percutaneous pulmonary biopsies with real-time CT fluoroscopy.

OBJECTIVE: Clinical evaluation of computed tomography (CT) fluoroscopy and comparison with conventional CT guidance for monitoring of percutaneous pulmonary biopsy procedures. METHODS: Twenty CT-guided pulmonary biopsy procedures were conducted. The interventions have prospectively been performed either with CT fluoroscopy or with conventional CT guidance. About 120 kV and 50 mA with a frame-rate of eight images per second were used for CT fluoroscopy. Number of pleural needle passages, procedure times, radiation doses and histologic results were analyzed separately for both methods. RESULTS: Compared with conventional CT guidance, CT fluoroscopy was associated with less pleural needle passages (1.8+/-0.6 vs. 1.1+/-0.3; P=0.003, t-test) and procedure times were shorter than for conventional CT guidance (12.7+/-2.2 min vs. 26.7+/-16.4 min; P=0.02). Analysis of estimated patient related radiation exposure and histologic outcome showed no significant difference between conventional and fluoroscopic CT-guided procedures (P>0.05). CONCLUSION: CT fluoroscopy facilitates guidance of percutaneous pulmonary biopsy procedures. Compared with conventional CT assistance, procedure times are decreased and less pleural needle passages are required. While patient-related radiation exposure is similar, operator-related radiation exposure remains a disadvantage associated with CT fluoroscopy.

Aged↗