Nanoflow gradient generator for capillary high-performance liquid chromatography.

A novel method of generating a nanoflow gradient elution for a capillary high-performance liquid chromatography (HPLC) system has been developed. An important feature of this system is that any gradient (GR) profile generated by a conventional microflow GR pump can be asymptotically traced and converted as a corresponding nanoflow GR profile simply by using a 10-port switching valve with two injection loops installed. Consequently, it has been called an "asymptotic trace 10-port valve" (AT10PV) nanoflow GR generator. Performance of the AT10PV nanoflow GR generator was tested in the range of flow rates from 50 to 500 nL/min. The test demonstrated that the AT10PV nanoflow GR generator can asymptotically trace the original gradient profile with good reproducibility. A capillary HPLC system using the AT10PV nanoflow GR generator provides reasonably good repeatability of peak retention times on the chromatogram of the tryptic digest of a BSA sample, RSD of less than 0.3% at a flow rate of 200 nL/min. It also enables sequential running of a series of sample injections in the same manner as conventional analysis at microflow rates.

Acetone↗

Structural assignment of isomeric 2-aminopyridine-derivatized oligosaccharides using MSn spectral matching.

Two isomeric pairs of 2-aminopyridine (PA)-derivatized fucosylated and non-fucosylated oligosaccharides (complex-type N-glycans of IgG) were analyzed using liquid chromatography/ion trap mass spectrometry (LC/ITMS) with a sonic spray ionization source and by varying the collision-induced dissociation voltage. Reproducibility of MS(n) (n = 2) spectra obtained by LC/ITMS was tested considering both fragment ions (m/z) and intensities. A comparison of their MS(n) spectra and evaluation of similarities (or matching), based on correlation coefficients between MS(n) spectra, was investigated as a possibility for structural assignment of the isomers. It is shown that such MS(n) spectral matching is useful and applicable to the structural assignment of relatively large fucosylated and sialylated PA-oligosaccharides released from IgG based on Bn- and Yn-type fragmentations of the corresponding [M+H+Na](2+) ions.

Aminopyridines↗

Enhanced mass detection of oligonucleotides using reverse-phase high-performance liquid chromatography/electrospray ionization ion-trap mass spectrometry.

A new method providing enhanced sensitivity for the analysis of oligonucleotides using an on-line coupled system of reversed-phase high-performance liquid chromatography (RP-HPLC) and electrospray ionization ion-trap mass spectrometry (ESI-MS) has been developed. The presented method allows the use of the standard gradient elution of 0.1 M triethylammonium acetate (TEAA) buffer (adjusted to pH 7.0 with acetic acid) and acetonitrile that is typically used for the separation of oligonucleotides in RP-HPLC. An added feature of this method is the ability to combine and mix additional 0.1 M imidazole in acetonitrile after the separation column for improved ESI-MS performance. This is similar to the post-column reaction method in liquid chromatography (LC) and the liquid sheath flow method in LC/ESI-MS, both of which offer the advantage of not compromising the chromatographic separation conditions. The application of this new method is demonstrated to afford improved sensitivity for the analysis of oligonucleotides (20-50 mer) via on-line coupled HPLC/ESI-MS analysis and purification systems.

Chromatography, High Pressure Liquid↗