Closed-loop nonlinear system identification via the vector optimal parameter search algorithm: application to heart rate baroreflex control.

The vector optimal parameter search (VOPS) and the constrained optimal parameter search (COPS) are recently developed algorithms for closed-loop linear system identification. We extend both algorithms to be applicable to a closed-loop nonlinear system, which is characterized by a vector nonlinear autoregressive model. Monte Carlo simulations of nonlinear closed-loop systems were performed to compare the performance of the VOPS to the widely utilized vector least squares (VLS), the COPS and the total least squares (TLS) approaches. The relative error and linear transfer functions are computed to determine the accuracy of each method. The comparative results show that both the VOPS and COPS algorithms provide far superior parameter estimates than does the VLS for all simulation examples considered. The TLS provides better estimates than the VOPS, COPS and VLS when there is only observation noise present in the data. However, the performance of the TLS degrades considerably when the data are corrupted by dynamic noise. The clinical applicability of the two extended methods is examined by applying them to a classical physiological closed-loop system, the heart rate baroreflex. It was found that while both control and blockade of parasympathetic system conditions are dominated by linear dynamics, more nonlinearity was observed in the latter. This observation is statistically supported by the calculation of the mutual information of the data and their surrogates.

Algorithms↗

Quantifying cardiac sympathetic and parasympathetic nervous activities using principal dynamic modes analysis of heart rate variability.

The ratio between low-frequency (LF) and high-frequency (HF) spectral power of heart rate has been used as an approximate index for determining the autonomic nervous system (ANS) balance. An accurate assessment of the ANS balance can only be achieved if clear separation of the dynamics of the sympathetic and parasympathetic nervous activities can be obtained, which is a daunting task because they are nonlinear and have overlapping dynamics. In this study, a promising nonlinear method, termed the principal dynamic mode (PDM) method, is used to separate dynamic components of the sympathetic and parasympathetic nervous activities on the basis of ECG signal, and the results are compared with the power spectral approach to assessing the ANS balance. The PDM analysis based on the 28 subjects consistently resulted in a clear separation of the two nervous systems, which have similar frequency characteristics for parasympathetic and sympathetic activities as those reported in the literature. With the application of atropine, in 13 of 15 supine subjects there was an increase in the sympathetic-to-parasympathetic ratio (SPR) due to a greater decrease of parasympathetic than sympathetic activity (P=0.003), and all 13 subjects in the upright position had a decrease in SPR due to a greater decrease of sympathetic than parasympathetic activity (P<0.001) with the application of propranolol. The LF-to-HF ratio calculated by the power spectral density is less accurate than the PDM because it is not able to separate the dynamics of the parasympathetic and sympathetic nervous systems. The culprit is equivalent decreases in both the sympathetic and parasympathetic activities irrespective of the pharmacological blockades. These findings suggest that the PDM shows promise as a noninvasive and quantitative marker of ANS imbalance, which has been shown to be a factor in many cardiac and stress-related diseases.

Adult↗

A robust method for detection of linear and nonlinear interactions: application to renal blood flow dynamics.

We have developed a method that can identify switching dynamics in time series, termed the improved annealed competition of experts (IACE) algorithm. In this paper, we extend the approach and use it for detection of linear and nonlinear interactions, by employing histograms showing the frequency of switching modes obtained from the IACE, then examining time-frequency spectra. This extended approach is termed Histogram of improved annealed competition of experts-time frequency (HIACE-TF). The hypothesis is that frequent switching dynamics in HIACE-TF results are due to interactions between different dynamic components. To validate this assertion, we used both simulation examples as well as application to renal blood flow data. We compared simulation results to a time-phase bispectrum (TPB) approach, which can also be used to detect time-varying quadratic phase coupling between various components. We found that the HIACE-TF approach is more accurate than the TPB in detecting interactions, and remains accurate for signal-to-noise ratios as low as 15 dB. With all 10 data sets, comprised of volumetric renal blood flow data, we also validated the feasibility of the HIACE-TF approach in detecting nonlinear interactions between the two mechanisms responsible for renal autoregulation. Further validation of the HIACE-TF approach was achieved by comparing it to a realistic mathematical model that has the capability to generate either the presence or the absence of nonlinear interactions between two renal autoregulatory mechanisms.

Algorithms↗

A high resolution approach to estimating time-frequency spectra and their amplitudes.

A high resolution approach to estimating time-frequency spectra (TFS) and associated amplitudes via the use of variable frequency complex demodulation (VFCDM) is presented. This is a two-step procedure in which the previously developed time-varying optimal parameter search (TVOPS) technique is used to obtain TFS, followed by using the VFCDM to obtain even greater TFS resolution and instantaneous amplitudes associated with only the specific frequencies of interest. This combinational use of the TVOPS and the VFCDM is termed the TVOPS-VFCDM. Simulation examples are provided to demonstrate the performance of the TVOPS-VFCDM for high resolution TFS as well as instantaneous amplitude estimation. The simulation results show that the TVOPS-VFCDM approach provides the highest resolution and most accurate amplitude estimates when compared to the smoothed pseudo Wigner-Ville, continuous wavelet transform and Hilbert-Huang transform methods. Application of the TVOPS-VFCDM to renal blood flow data indicates some promise of a quantitative approach to understanding the dynamics of renal autoregulatory mechanisms as well as a possible approach to quantitatively discriminating between different strains of rats.

Algorithms↗

Frequency modulation between low- and high-frequency components of the heart rate variability spectrum.

Interactions among physiological mechanisms are abundant in biomedical signals, and they may exist to maintain efficient homeostasis. For example, sympathetic and parasympathetic neural activities interact to either elevate or depress the heart rate to maintain homeostasis. There has been considerable effort devoted to developing algorithms that can detect interactions between various physiological mechanisms. However, methods used to detect the presence of interactions between the sympathetic and parasympathetic nervous systems, to take one example, have had limited success. This may be because interactions in physiological systems are non-linear and non-stationary. The goal of this work was to identify non-linear interactions between the sympathetic and parasympathetic nervous systems in the form of frequency and amplitude modulations in human heart-rate data (n=6). To this end, wavelet analysis was performed, followed by frequency analysis of the resultant wavelet decomposed signals in several frequency brackets we define as: very low frequency (f<0.04 Hz), low frequency (0.04-0.15 Hz) and high frequency (0.15-0.4 Hz). Our analysis suggests that the high-frequency bracket is modulated by the low-frequency bracket in the heart rate data obtained in both upright and sitting positions. However, there was no evidence of amplitude modulation among these frequencies.

Algorithms↗

Tubuloglomerular feedback-dependent modulation of renal myogenic autoregulation by nitric oxide.

Nonselective inhibition of nitric oxide (NO) synthase (NOS) augments myogenic autoregulation, an action that implies enhancement of pressure-induced constriction and dilatation. This pattern is not explained solely by interaction with a vasoconstrictor pathway. To test involvement of the Rho-Rho kinase pathway in modulation of autoregulation by NO, the selective Rho kinase inhibitor Y-27632 and/or the NOS inhibitor N(omega)-nitro-l-arginine methyl ester (l-NAME) were infused into the left renal artery of anesthetized rats. Y-27632 and l-NAME were also infused into isolated, perfused hydronephrotic kidneys to assess myogenic autoregulation over a wide range of perfusion pressure. In vivo, l-NAME reduced renal vascular conductance and augmented myogenic autoregulation, as shown by increased slope of gain reduction and associated phase peak in the pressure-flow transfer function. Y-27632 (10 mumol/l) strongly dilated the renal vasculature and profoundly inhibited autoregulation in the absence or presence of l-NAME in vivo and in vitro. Afferent arteriolar constriction induced by 30 mmol/l KCl was reversed (-92 +/- 3%) by Y-27632. Phenylephrine caused strong renal vasoconstriction but did not affect autoregulation. Inhibition of neuronal NOS by N(5)-(1-imino-3-butenyl)-l-ornithine (l-VNIO) did not cause significant vasoconstriction but did augment myogenic autoregulation. Thus vasoconstriction is neither necessary (l-VNIO) nor sufficient (phenylephrine) to explain the augmented myogenic autoregulation induced by l-NAME. The effect of l-VNIO implicates tubuloglomerular feedback (TGF) and neuronal NOS at the macula densa in regulation of the myogenic mechanism. This conclusion was confirmed by the demonstration that systemic furosemide removed the TGF signature from the pressure-flow transfer function and significantly inhibited myogenic autoregulation. In the presence of furosemide, augmentation of myogenic autoregulation by l-NAME was significantly reduced. These results provide a potential mechanism to explain interaction between myogenic and TGF-mediated autoregulation.

Amides↗

Interactions between TGF-dependent and myogenic oscillations in tubular pressure and whole kidney blood flow in both SDR and SHR.

We previously showed that nonlinear interactions between the two renal autoregulatory mechanics (tubuloglomerular feedback and the myogenic mechanism) were observed in the stop flow pressure (SFP) and whole kidney blood flow data from Sprague-Dawley rats (SDR) using time-invariant bispectrum analysis (3, 4). No such nonlinear interactions were observed in either SFP or whole kidney blood flow data obtained from spontaneously hypertensive rats (SHR). We speculated that the failure to detect nonlinear interactions in the SHR data may be related to our observation that these interactions were not continuous and therefore had time-varying characteristics. Thus the absence of such nonlinear interactions may be due to an inappropriate time-invariant method being applied to data that are especially time varying in nature. We examine this possibility in this paper by using a time-varying bispectrum approach, which we developed for this purpose. Indeed, we found significant nonlinear interactions in SHR (n = 18 for SFP; n = 12 for whole kidney blood flow). Moreover, the duration of nonlinear coupling is found statistically to be longer (P = 0.001) in SFP data from either SDR or SHR than it is in whole kidney data from either type of rat. We conclude that nonlinear coupling is present at both the single nephron as well as the whole kidney level for SDR and SHR. In addition, SHR data at the whole kidney level exhibit the most transient nonlinear coupling phenomena.

Animals↗

Nonlinear interactions in renal blood flow regulation.

We have developed a model of tubuloglomerular feedback (TGF) and the myogenic mechanism in afferent arterioles to understand how the two mechanisms are coupled. This paper presents the model. The tubular model predicts pressure, flow, and NaCl concentration as functions of time and tubular length in a compliant tubule that reabsorbs NaCl and water; boundary conditions are glomerular filtration rate (GFR), a nonlinear outflow resistance, and initial NaCl concentration. The glomerular model calculates GFR from a change in protein concentration using estimates of capillary hydrostatic pressure, tubular hydrostatic pressure, and plasma flow rate. The arteriolar model predicts fraction of open K channels, intracellular Ca concentration (Ca(i)), potential difference, rate of actin-myosin cross bridge formation, force of contraction, and length of elastic elements, and was solved for two arteriolar segments, identical except for the strength of TGF input, with a third, fixed resistance segment representing prearteriolar vessels. The two arteriolar segments are electrically coupled. The arteriolar, glomerular, and tubular models are linked; TGF modulates arteriolar circumference, which determines vascular resistance and glomerular capillary pressure. The model couples TGF input to voltage-gated Ca channels. It predicts autoregulation of GFR and renal blood flow, matches experimental measures of tubular pressure and macula densa NaCl concentration, and predicts TGF-induced oscillations and a faster smaller vasomotor oscillation. There are nonlinear interactions between TGF and the myogenic mechanism, which include the modulation of the frequency and amplitude of the myogenic oscillation by TGF. The prediction of modulation is confirmed in a companion study (28).

Blood Pressure↗

Chemical activation of pre-Bötzinger complex in vivo reduces respiratory network complexity.

In the in vivo anesthetized adult cat model, multiple patterns of inspiratory motor discharge have been recorded in response to chemical stimulation and focal hypoxia of the pre-Bötzinger complex (pre-BötC), suggesting that this region may participate in the generation of complex respiratory dynamics. The complexity of a signal can be quantified using approximate entropy (ApEn) and multiscale entropy (MSEn) methods, both of which measure the regularity (orderliness) in a time series, with the latter method taking into consideration temporal fluctuations in the underlying dynamics. The current investigation was undertaken to examine the effects of pre-BötC-induced excitation of phasic phrenic nerve discharge, which is characterized by high-amplitude, rapid-rate-of-rise, short-duration bursts, on the complexity of the central inspiratory neural controller in the vagotomized, chloralose-anesthetized adult cat model. To assess inspiratory neural network complexity, we calculated the ApEn and MSEn of phrenic nerve bursts during eupneic (basal) discharge and during pre-BötC-induced excitation of phasic inspiratory bursts. Chemical stimulation of the pre-BötC using DL-homocysteic acid (DLH; 10 mM; 10-20 nl; n=10) significantly reduced the ApEn from 0.982+/-0.066 (mean+/-SE) to 0.664+/-0.067 (P<0.001) followed by recovery ( approximately 1-2 min after DLH) of the ApEn to 1.014+/-0.067; a slightly enhanced magnitude reduction in MSEn was observed. Focal pre-BötC hypoxia (induced by sodium cyanide; NaCN; 1 mM; 20 nl; n=2) also elicited a reduction in both ApEn and MSEn, similar to those observed for the DLH-induced response. These observations demonstrate that activation of the pre-BötC reduces inspiratory network complexity, suggesting a role for the pre-BötC in regulation of complex respiratory dynamics.

Animals↗

Estimation of time-varying coherence function using time-varying transfer functions.

We introduce a new method to estimate reliable time-varying coherence functions (TVCF) for causal systems. The technique is based on our previously developed method to estimate time-varying transfer functions (TVTF), known as the time-varying optimal parameter search algorithm [Zou, R., H. Wang, and K. H. Chon. A robust time-varying identification algorithm using basis functions. Ann. Biomed. Eng. 31: 840-853, 2003]. The TVCF is estimated by the multiplication of two TVTFs. The two TVTFs are obtained using signal x as the input and signal y as the output to produce the first TVTF, and signal y as the input and signal x as the output to produce the second TVTF. Demonstration of the feasibility and efficacy of the proposed approach is provided with both simulation examples and application to renal blood flow and pressure data. The proposed approach provides higher time-frequency resolution TVCF than afforded by the short time Fourier transform based TVCF.

Animals↗

Mutual information function assesses autonomic information flow of heart rate dynamics at different time scales.

The autonomic information flow (AIF) represents the complex communication within the Autonomic Nervous System (ANS). It can be assessed by the mutual information function (MIF) of heart rate fluctuations (HRF). The complexity of HRF is based on several interacting physiological mechanisms operating at different time scales. Therefore one prominent time scale for HRF complexity analysis is not given a priori. The MIF reflects the information flow at different time scales. This approach is defined and evaluated in the present paper. In order to aggregate relevant physiological time scales, the MIF of HRF obtained from eight adult Lewis rats during the awake state, under general anesthesia, with additional vagotomy, and additional betal-adrenergic blockade are investigated. Physiologically relevant measures of the MIF were assessed with regard to the discrimination of these states. A simulation study of a periodically excited pendulum is performed to clarify the influence of the time scale of MIF in comparison to the Kolmogorov Sinai entropy (KSE) of that well defined system. The general relevance of the presented AIF approach was confirmed by comparing mutual information, approximate entropy, and sample entropy at their respective time scales.

Algorithms↗

Multiple time-varying dynamic analysis using multiple sets of basis functions.

We extend a recently developed algorithm that expands the time-varying parameters onto a single set of basis functions, to multiple sets of basis functions. This feature allows the capability to capture many different dynamics that may be inherent in the system. A single set of basis functions that has its own unique characteristics can best capture dynamics of the system that have similar features. Therefore, for systems that have multiple dynamics, the use of a single set of basis functions may not be adequate. Computer simulation examples do indeed show the benefit of using multiple sets of basis functions over the single set of basis functions for cases with many switching dynamics. Moreover, the proposed method remains accurate even under significant noise contamination. Application of the proposed approach to blood pressure data likewise indicate better tracking capability of the two sets of basis function than the recursive least squares or a single set of basis functions.

Algorithms↗

Identification of transient renal autoregulatory mechanisms using time-frequency spectral techniques.

Identification of the two principal mediators of renal autoregulation from time-series data is difficult, as both the tubuloglomerular feedback (TGF) and myogenic (MYO) mechanisms interact and share a common effector, the afferent arteriole. Moreover, although both mechanisms can exhibit oscillations in well-characterized frequency bands, these systems often operate in nonoscillatory states not detectable by frequency-domain analysis. To overcome these difficulties, we have developed a new approach to the characterization of the TGF and MYO systems. A laser Doppler probe is used to measure fluctuations in local cortical blood flow (CBF) in response to spontaneous changes in blood pressure (BP) and to large imposed perturbations in BP, which elicit strong, simultaneous, transient, oscillatory blood flow responses. These transient responses are identified by high-resolution time-frequency spectral analysis of the time-series data. In this report, we compare four different time-frequency spectral techniques (the short-time Fourier transform (STFT), smoothed pseudo Wigner-Ville, and two recently developed methods: the Hilbert-Huang transform and time varying optimal parameter search (TVOPS)) to determine which of these four methods is best suited for the identification of transient oscillations in renal autoregulatory mechanisms. We found that TVOPS consistently provided the best performance in both simulation examples and identification of the two autoregulatory mechanisms in actual data. While the STFT suffers in time and frequency resolution as compared to the other three methods, it was able to identify the two autoregulatory mechanisms. Taken together, our experience suggests a two level approach to the analysis of renal blood flow (RBF) data: STFT to obtain a low-resolution time-frequency spectrogram, followed by the use of a higher resolution technique, such as the TVOPS, if even higher time-frequency resolution of the transient responses is required.

Algorithms↗

A method for segmentation of switching dynamic modes in time series.

A method to identify switching dynamics in time series, based on Annealed Competition of Experts algorithm (ACE), has been developed by Kohlmorgen et al. Incorrect selection of embedding dimension and time delay of the signal significantly affect the performance of the ACE method, however. In this paper, we utilize systematic approaches based on mutual information and false nearest neighbor to determine appropriate embedding dimension and time delay. Moreover, we obtained further improvements to the original ACE method by incorporating a deterministic annealing approach as well as phase space closeness measure. Using these improved implementations, we have enhanced the performance of the ACE algorithm in determining the location of the switching of dynamic modes in the time series. The application of the improved ACE method to heart rate data obtained from rats during control and administration of double autonomic blockade conditions indicate that the improved ACE algorithm is able to segment dynamic mode changes with pinpoint accuracy and that its performance is superior to the original ACE algorithm.

Algorithms↗

Time-frequency representation of inspiratory motor output in anesthetized C57BL/6 mice in vivo.

Inspiratory motor discharges, in addition to long-time-scale rhythmic oscillatory bursting, exhibit short-time-scale rhythmic oscillations that have been identified, and subsequently characterized, using power spectral analyses [predominantly fast-Fourier transforms (FFT)]. These analyses assume that the signal being analyzed is stationary; however, this is not the case for most biological signals, which exhibit varying degrees of nonstationarity. To overcome this limitation, time-frequency methods, which provide not only the frequency content but also information regarding the timing of these fast rhythmic oscillations (i.e., dynamics of spectral activity), should be used. Thus this study was performed to investigate the dynamic or time-varying features of spectral activity in inspiratory motor output. Both conventional time-invariant and time-frequency (time-varying) spectral analysis methods were performed on recordings of diaphragm EMG, phrenic nerve, and hypoglossal nerve discharges obtained from spontaneously breathing urethan-anesthetized adult C57BL/6 mice. Conventional time-invariant spectral analysis using a FFT algorithm revealed three dominant peaks in the power spectrum, which were located at 1) 20-46, 2) 83-149, and 3) 177-227 Hz. Time-frequency spectral analysis using a generalized time-frequency representation (TFR) with the smoothed pseudo-Wigner-Ville distribution (SPWD) kernel confirmed the general location of these spectral peaks, identified additional spectral peaks within the frequency ranges described above, and revealed a time-dependent expression of spectral activity within the inspiratory burst for each of the frequency ranges. Furthermore, this method revealed that 1) little or no spectral activity occurs during the initial portion of the inspiratory burst in any of the frequency ranges identified, 2) transient oscillations in the magnitude of spectral power exist where spectral activity occurs, and 3) total spectral power exhibits an augmenting pattern over the course of the inspiratory burst. These data, which provide the first description of spectral content in inspiratory motor discharges in adult mice, show that both time-invariant and time-varying spectral analysis methods are capable of identifying short-time-scale rhythmic oscillations in inspiratory motor discharge (as expected); however, the dynamic (i.e., timing) features of this oscillatory activity can only be obtained using the time-frequency method. We suggest that time-frequency methods, such as the SPWD, should be used in future studies examining short-time-scale (fast) rhythmic oscillations in inspiratory motor discharges, because additional insight into the neural control mechanisms that participate in inspiratory-phase neuronal and motoneuronal synchronization may be obtained.

Algorithms↗

Interactions of TGF-dependent and myogenic oscillations in tubular pressure.

We have previously shown that there are two oscillating components in spontaneously fluctuating single-nephron blood flow obtained from Sprague-Dawley rats (Yip K-P, Holstein-Rathlou NH, and Marsh DJ. Am J Physiol Renal Physiol 264: F427-F434, 1993). The slow oscillation (20-30 mHz) is mediated by tubuloglomerular feedback (TGF), whereas the fast oscillation (100 mHz) is probably related to spontaneous myogenic activity. The fast oscillation is rarely detected in spontaneous tubular pressure because of its small magnitude and the fact that tubular compliance filters pressure waves. We detected myogenic oscillation superimposed on TGF-mediated oscillation when ambient tubular flow was interrupted. Two well-defined peaks are present in the mean power spectrum of stop-flow pressure (SFP) centering at 25 and 100 mHz (n = 13), in addition to a small peak at 125-130 mHz. Bispectral analysis indicates that two of these oscillations (30 and 100 mHz) interact nonlinearly to produce the third oscillation at 125-130 mHz. The presence of nonlinear interactions between TGF and myogenic oscillations indicates that estimates of the relative contribution of each of these mechanisms in renal autoregulation need to account for this interaction. The magnitude of myogenic oscillations was considerably smaller in the SFP measured from spontaneously hypertensive rats (SHR, n = 13); consequently, nonlinear interactions were not observed with bispectral analysis. Reduced augmentation of myogenic oscillations in SFP of SHR might account for the failure in detecting nonlinear interactions in SHR.

Animals↗

Robust algorithm for estimation of time-varying transfer functions.

We introduce a new method to estimate reliable time-varying (TV) transfer functions (TFs) and TV impulse response functions. The method is based on TV autoregressive moving average models in which the TV parameters are accurately obtained using the optimal parameter search method which we have previously developed. The new method is more accurate than the recursive least-squares (RLS), and remains robust even in the case of significant noise contamination. Furthermore, the new method is able to track dynamics that change abruptly, which is certainly a deficiency of the RLS. Application of the new method to renal blood pressure and flow revealed that hypertensive rats undergo more complex and TV autoregulation in maintaining stable blood flow than do normotensive rats. This observation has not been previously revealed using time-invariant TF analyses. The newly developed approach may promote the broader use of TV system identification in studies of physiological systems and makes linear and nonlinear TV modeling possible in certain cases previously thought intractable.

Algorithms↗

Nonlinear analysis of the separate contributions of autonomic nervous systems to heart rate variability using principal dynamic modes.

This paper introduces a modified principal dynamic modes (PDM) method, which is able to separate the dynamics of sympathetic and parasympathetic nervous activities. The PDM is based on the principle that among all possible choices of expansion bases, there are some that require the minimum number of basis functions to achieve a given mean-square approximation of the system output. Such a minimum set of basis functions is termed PDMs of the nonlinear system. We found that the first two dominant PDMs have similar frequency characteristics for parasympathetic and sympathetic activities, as reported in the literature. These results are consistent for all nine of our healthy human subjects using our modified PDM approach. Validation of the purported separation of parasympathetic and sympathetic activities was performed by the application of the autonomic nervous system blocking drugs atropine and propranolol. With separate applications of the respective drugs, we found a significant decrease in the amplitude of the waveforms that correspond to each nervous activity. Furthermore, we observed near complete elimination of these dynamics when both drugs were given to the subjects. Comparison of our method to the conventional low-frequency/high-frequency ratio shows that our proposed approach provides more accurate assessment of the autonomic nervous balance. Our nonlinear PDM approach allows a clear separation of the two autonomic nervous activities, the lack of which has been the main reason why heart rate variability analysis has not had wide clinical acceptance.

Adult↗