Search PubMed⌕ Search

Biomedical subjects

Kevin J Parker

Publications and source records attributed to Kevin J Parker.

8 recordsLinked to original sources

Sonoelastographic imaging of interference patterns for estimation of shear velocity distribution in biomaterials.

The authors have recently demonstrated the shear wave interference patterns created by two coherent vibration sources imaged with the vibration sonoelastography technique. If the two sources vibrate at slightly different frequencies omega and omega+deltaomega, respectively, the interference patterns move at an apparent velocity of (deltaomega/2omega)upsilon(shear), where upsilon(shear) is the shear wave speed. We name the moving interference patterns "crawling waves." In this paper, we extend the techniques to inspect biomaterials with nonuniform stiffness distributions. A relationship between the local crawling wave speed and the local shear wave velocity is derived. In addition, a modified technique is proposed whereby only one shear wave source propagates shear waves into the medium at the frequency omega. The ultrasound probe is externally vibrated at the frequency omega-deltaomega. The resulting field estimated by the ultrasound (US) scanner is proven to be an exact representation of the propagating shear wave field. The authors name the apparent wave motion "holography waves." Real-time video sequences of both types of waves are acquired on various inhomogeneous elastic media. The distribution of the crawling/holographic wave speeds are estimated. The estimated wave speeds correlate with the stiffness distributions.

Animals↗

Prostate cancer: three-dimensional sonoelastography for in vitro detection.

PURPOSE: To prospectively evaluate the accuracy of three-dimensional (3D) sonoelastographic imaging, relative to that of gray-scale ultrasonography (US), in the in vitro detection of prostate cancer. MATERIALS AND METHODS: The study was approved by the institutional review board and was HIPAA compliant. Informed consent was obtained from all patients. Nineteen prostatectomy specimens from patients aged 46-70 years with biopsy-proved prostate cancer were scanned in three dimensions by using conventional B-mode US and sonoelastography with vibrations of more than 100 Hz. Step-sectioned whole-mount histologic specimens were used to create a 3D volume of the prostate and the tumors within it. B-mode US scans and regions of low vibration on the sonoelastographic images (hard regions) were formatted in three dimensions. The lesions in the 19 cases were classified into two groups, as follows: G1 lesions were pathologically confirmed tumors with a volume of at least 1.0 cm3, and G2 lesions were pathologically confirmed tumors smaller than 1.0 cm3. G1 lesions were evaluated with B-mode US and sonoelastography and classified as true-positive, false-positive, true-negative, or false-negative; G2 lesions were evaluated only with sonoelastography. Findings at histologic examination were used as the reference standard. True-positive findings necessitated 3D lesion correlation between pathologic and imaging data. Conventional definitions of accuracy and sensitivity were used for statistical analysis. RESULTS: For G1 lesions (seven lesions with a volume of at least 1.0 cm3), sonoelastography had an accuracy of 55% and a sensitivity of 71% and B-mode US had an accuracy of 17% and a sensitivity of 29%. The mean tumor volume was 3.1 cm3 +/- 2.1 (standard deviation). For G2 lesions (22 lesions with a volume of less than 1.0 cm3), the mean tumor volume was 0.32 cm3 +/- 0.21. Sonoelastography had an accuracy of 34% and a sensitivity of 41%; there were six false-positive findings. CONCLUSION: Sonoelastography performed considerably better than did gray-scale US in the depiction of prostate cancer for tumors with volumes of more than 1 cm3.

Aged↗

A unified view of imaging the elastic properties of tissue.

A number of different approaches have been developed to estimate and image the elastic properties of tissue. The biomechanical properties of tissues are vitally linked to function and pathology, but cannot be directly assessed by conventional ultrasound, MRI, CT, or nuclear imaging. Research developments have introduced new approaches, using either MRI or ultrasound to image the tissue response to some stimulus. A wide range of stimuli has been evaluated, including heat, water jets, vibration shear waves, compression, and quasistatic compression, using single or multiple steps or low-frequency (<10 Hz) cyclic excitation. These may seem to be greatly dissimilar, and appear to produce distinctly different types of information and images. However, our purpose in this tutorial is to review the major classes of excitation stimuli, and then to demonstrate that they produce responses that fall within a common spectrum of elastic behavior. Within this spectrum, the major classes of excitation include step compression, cyclic quasistatic compression, harmonic shear wave excitation, and transient shear wave excitation. The information they reveal about the unknown elastic distribution within an imaging region of interest are shown to be fundamentally related because the tissue responses are governed by the same equation. Examples use simple geometry to emphasize the common nature of the approaches.

Biomechanical Phenomena↗

Sonoelastographic imaging of interference patterns for estimation of the shear velocity of homogeneous biomaterials.

The shear wave velocity is one of a few important parameters that characterize the mechanical properties of bio-materials. In this paper, two noninvasive methods are proposed to measure the shear velocity by inspecting the shear wave interference patterns. In one method, two shear wave sources are placed on the opposite two sides of a sample, driven by the identical sinusoidal signals. The shear waves from the two sources interact to create interference patterns, which are visualized by the vibration sonoelastography technique. The spacing between the pattern bands equals half of the shear wavelength. The shear velocity can be obtained by taking the product of the wavelength and the frequency. An alternative method is to drive the two vibration sources at slightly different frequencies. In this case, the interference patterns no longer remain stationary. It is proved that the apparent velocity of the moving patterns is proportional to the shear velocity in the medium. Since the apparent velocity of the patterns can be measured by analysing the video sequence, the shear velocity can be obtained thereafter. These approaches are validated by a conventional shear wave time-of-flight approach, and they are accurate within 4% on various homogeneous tissue-mimicking phantoms.

Connective Tissue↗

Three-dimensional registration of prostate images from histology and ultrasound.

A whole mount histology protocol for 3-D tissue reconstruction to compare the size and spatial location of tumors (and other components) identified in histology data with that from 3-D ultrasound (US) images is presented. Prostate specimens are imaged in 3-D using B-mode (US) and sonoelastography. The prostate surface is outlined in each B-mode image and a 3-D surface reconstruction is made. The specimen is then prepared for whole mount histology and the histology slides are digitally reconstructed to make a 3-D surface. These two surfaces are then aligned using a 3-D correlation algorithm, and the tumor boundary determined by the pathologist is compared with that using sonoelastography. 3-D images showing the overlapping histology and sonoelastography of prostate surface reconstructions for one prostate are presented to illustrate the technique; results for four prostates yielded an accuracy of 92% +/- 3%.

Humans↗

Implementation issues in ultrasonic flow imaging.

This article addresses several implementation issues in ultrasonic flow imaging. We discuss frequency-dependent scattering and attenuation, use of interpolation for computation intensive methods and implications of the use of chirps to increase bandwidth. We also discuss wall filtering issues; our observations show that the butterfly search estimator may be capable of detecting flow in the vicinity of strong stationary scatterers (clutter) without additional processing such as wall-filtering. Illustrative examples are given for simulated and experimental data.

Algorithms↗

Doppler ultrasound imaging of magnetically vibrated brachytherapy seeds.

Vibration induced by an alternating magnetic field is proposed as a method for the identification of modified brachytherapy seeds with Doppler ultrasound. In vitro experiments with agar and liver-tissue phantoms using a clinical scanner and simple apparatus demonstrate that the technique is feasible.

Animals↗

Shear wave focusing for three-dimensional sonoelastography.

A new vibration scheme is shown to provide localized vibration fields for three-dimensional sonoelastography imaging. The theoretical vibration distributions of double strip loads vibrating normally to the surface of a semi-infinite elastic space are calculated. A localization or focusing of shear waves inbetween the double-strip loads is predicted. Experimentally, two parallel rigid rectangular cross-section bars are mounted on an electromagnetic shaker. Driven by the signal source, the bars vibrate against the surface of a tissue-mimicking phantom. The double-bar source is also used to propagate shear wave into an ex vivo prostate phantom with a 6 mm "tumor" in it. A combination of high frequencies (400-600 Hz) is used to drive the double-bar applicator. In the phantom experiments, a shear wave focal zone with higher vibration amplitude and uniformity predicted by the theory was confirmed. The position of the focal zone is controllable when adjusting the separation of the bars as the theory shows. When this vibration scheme was used in a prostate phantom experiment, high-resolution tumor images with clear boundaries are obtained. The parallel bar is an ideal applicator to create more uniform vibration within a controllable localized volume. The field has uniformity especially in the direction along the bars.

Culture Techniques↗