Search PubMed⌕ Search

Biomedical subjects

Kevin J Johnson

Publications and source records attributed to Kevin J Johnson.

9 recordsLinked to original sources

Femtosecond pump-probe studies of nitrosyl chloride photochemistry in solution.

We present a femtosecond pump-probe study of the primary events of nitrosyl chloride (ClNO) photochemistry in solution. Following 266 nm photolysis, the resulting evolution in optical density is measured for ClNO dissolved in acetonitrile, chloroform, and dichloromethane. The results demonstrate that photolysis results in the production of a photoproduct that has an absorption band maximum at 295 nm in acetonitrile and 330 nm in chloroform and dichloromethane. To determine the extent of Cl production, comparative photochemical studies of methyl hypochlorite (MeOCl) and ClNO are performed. Photolysis of MeOCl in solution results in the production of the Cl:solvent charge-transfer complex; therefore, a comparison of the spectral evolution observed following MeOCl and ClNO photolysis under identical photolysis conditions is performed to determine the extent of Cl production following ClNO photolysis. We find that similar to the gas-phase photochemistry, Cl and NO formation is the dominant photochemical channel in acetonitrile. However, the photochemistry in chloroform and dichloromethane is more complex, with a second product formed in addition to Cl and NO. It is proposed that in these solvents photoisomerization also occurs, resulting in the production of ClON. The results presented here represent the first detailed examination of the solution phase photochemistry of ClNO.

Journal Article↗

Compound-specific isotope analysis coupled with multivariate statistics to source-apportion hydrocarbon mixtures.

Compound Specific Isotope Analysis (CSIA) has been shown to be a useful tool for assessing biodegradation, volatilization, and hydrocarbon degradation. One major advantage of this technique is that it does not rely on determining absolute or relative abundances of individual components of a hydrocarbon mixture which may change considerably during weathering processes. However, attempts to use isotopic values for linking sources to spilled or otherwise unknown hydrocarbons have been hampered by the lack of a robust and rigorous statistical method for testing the hypothesis that two samples are or are not the same. Univariate tests are prone to Type I and Type II error, and current means of correcting error make hypothesis testing of CSIA source-apportionment data problematic. Multivariate statistical tests are more appropriate for use in CSIA data. However, many multivariate statistical tests require high numbers of replicate measurements. Due to the high precision of IRMS instruments and the high cost of CSIA analysis, it is impractical, and often unnecessary, to perform many replicate analyses. In this paper, a method is presented whereby triplicate CSIA information can be projected in a simplified data-space, enabling multivariate analysis of variance (MANOVA) and highly precise testing of hypotheses between unknowns and putative sources. The method relies on performing pairwise principal components analysis (PCA),then performing a MANOVA upon the principal component variables (for instance, three, using triplicate analyses) which capture most of the variability in the original data set. A probability value is obtained allowing the investigator to state whether there is a statistical difference between two individual samples. A protocol is also presented whereby results of the coupled pairwise PCA-MANOVA analysis are used to down-select putative sources for other analysis of variance methods (i.e., PCA on a subset of the original data) and hierarchical clustering to look for relationships among samples which are not significantly different. A Monte Carlo simulation of a 10 variable data set; tanks used to store, distribute, and offload fuels from Navy vessels; and a series of spilled oil samples and local tug boats from Norfolk, VA (U.S.A.) were subjected to CSIA and the statistical analyses described in this manuscript, and the results are presented. The analysis techniques described herein combined with traditional forensic analyses provide a collection of tools suitable for source-apportionment of hydrocarbons and any organic compound amenable to GC-combustion-IRMS.

Chromatography, Gas↗

Classification of gasoline data obtained by gas chromatography using a piecewise alignment algorithm combined with feature selection and principal component analysis.

A fast and objective chemometric classification method is developed and applied to the analysis of gas chromatography (GC) data from five commercial gasoline samples. The gasoline samples serve as model mixtures, whereas the focus is on the development and demonstration of the classification method. The method is based on objective retention time alignment (referred to as piecewise alignment) coupled with analysis of variance (ANOVA) feature selection prior to classification by principal component analysis (PCA) using optimal parameters. The degree-of-class-separation is used as a metric to objectively optimize the alignment and feature selection parameters using a suitable training set thereby reducing user subjectivity, as well as to indicate the success of the PCA clustering and classification. The degree-of-class-separation is calculated using Euclidean distances between the PCA scores of a subset of the replicate runs from two of the five fuel types, i.e., the training set. The unaligned training set that was directly submitted to PCA had a low degree-of-class-separation (0.4), and the PCA scores plot for the raw training set combined with the raw test set failed to correctly cluster the five sample types. After submitting the training set to piecewise alignment, the degree-of-class-separation increased (1.2), but when the same alignment parameters were applied to the training set combined with the test set, the scores plot clustering still did not yield five distinct groups. Applying feature selection to the unaligned training set increased the degree-of-class-separation (4.8), but chemical variations were still obscured by retention time variation and when the same feature selection conditions were used for the training set combined with the test set, only one of the five fuels was clustered correctly. However, piecewise alignment coupled with feature selection yielded a reasonably optimal degree-of-class-separation for the training set (9.2), and when the same alignment and ANOVA parameters were applied to the training set combined with the test set, the PCA scores plot correctly classified the gasoline fingerprints into five distinct clusters.

Algorithms↗

Ultrahigh density microarrays of solid samples.

We present a sectioning and bonding technology to make ultrahigh density microarrays of solid samples, cutting edge matrix assembly (CEMA). Maximized array density is achieved by a scaffold-free, self-supporting construction with rectangular array features that are incrementally scalable. This platform technology facilitates arrays of >10,000 tissue features on a standard glass slide, inclusion of unique sample identifiers for improved manual or automated tracking, and oriented arraying of stratified or polarized samples.

Equipment Design↗

Quantification of naphthalenes in jet fuel with GC x GC/Tri-PLS and windowed rank minimization retention time alignment.

Comprehensive, two-dimensional gas chromatography (GC x GC) is used in conjunction with trilinear partial least squares (Tri-PLS) to quantify the percent weight of naphthalenes (two-ring aromatic compounds) in jet fuel samples. The increased peak capacity and selectivity of GC x GC makes the technique attractive for the rapid, and possibly less tedious analysis of jet fuel. The analysis of complex mixtures by GC x GC is further enhanced through the use of chemometric techniques, including those designed for use on 2-D data such as Tri-PLS. Unfortunately, retention time variation, unless corrected, can be an impediment to chemometric analysis. Previous work has demonstrated that the effects of retention time variation can be mitigated in sub-regions of GC x GC chromatograms through the application of an objective retention time alignment algorithm based on rank minimization. Building upon this previous work, it is demonstrated here that the effects of retention time variation can be mitigated throughout an entire GC x GC chromatogram with an objective retention time alignment algorithm based on windowed rank minimization alignment. A significant decrease in calibration error is observed when the algorithm is applied to chromatograms prior to construction of Tri-PLS models. Fourteen jet fuel samples with known weight percentages of naphthalenes (ASTM D1840) were obtained. Each sample was subjected to five replicate five-minute GC x GC separations over a period of two days. A subset of nine samples spanning the range of weight percentages of naphthalenes was chosen as a calibration set and Tri-PLS calibration models were subsequently developed in order to predict the naphthalene content of the samples from the GC x GC chromatograms of the remaining five samples. Calibration models constructed from GC x GC chromatograms that were retention time corrected are shown to exhibit a root mean square error of prediction of roughly half that of calibration models constructed from uncorrected chromatograms. The error of prediction is lowered further to a value that nearly matches the uncertainty in the standard percent weight values (ca. 1% of the median percent volume value) when the aligned chromatograms are truncated to include only regions of the chromatogram populated by naphthalenes and compounds of similar polarity and boiling point.

Journal Article↗

Mutant alleles of the essential 14-3-3 gene in Candida albicans distinguish between growth and filamentation.

The opportunistic fungal pathogen Candida albicans has the ability to exploit diverse host environments and can either reside commensally or cause disease. In order to adapt to its new environment it must respond to new physical conditions, nutrient sources, and the host immune response. This requires the co-regulation of multiple signalling networks. The 14-3-3 family of proteins is highly conserved in all eukaryotic species. These proteins regulate signalling pathways involved in cell survival, the cell cycle, and differentiation, and effect their functions via interactions with phosphorylated serines/threonines. In C. albicans there is only one 14-3-3 protein, Bmh1p, and it is required for vegetative growth and optimal filamentation. In order to dissect separate functions of Bmh1p in C. albicans, site-directed nucleotide substitutions were made in the C. albicans BMH1 gene based on studies in other species. Putative temperature-sensitive, ligand-binding and dimerization mutants were constructed. In addition two mutant strains identified through random mutagenesis were analysed. All five mutant strains demonstrated varying defects in growth and filamentation. This paper begins to segregate functions of Bmh1p that are required for optimal growth and the different filamentation pathways. These mutant strains will allow the identification of 14-3-3 target interactions and correlate the individual functions of Bmh1p to cellular processes involved in pathogenesis.

14-3-3 Proteins↗

High-speed peak matching algorithm for retention time alignment of gas chromatographic data for chemometric analysis.

A rapid retention time alignment algorithm was developed as a preprocessing utility to be used prior to chemometric analysis of large datasets of diesel fuel profiles obtained using gas chromatography (GC). Retention time variation from chromatogram-to-chromatogram has been a significant impediment against the use of chemometric techniques in the analysis of chromatographic data due to the inability of current chemometric techniques to correctly model information that shifts from variable to variable within a dataset. The alignment algorithm developed is shown to increase the efficacy of pattern recognition methods applied to diesel fuel chromatograms by retaining chemical selectivity while reducing chromatogram-to-chromatogram retention time variations and to do so on a time scale that makes analysis of large sets of chromatographic data practical. Two sets of diesel fuel gas chromatograms were studied using the novel alignment algorithm followed by principal component analysis (PCA). In the first study, retention times for corresponding chromatographic peaks in 60 chromatograms varied by as much as 300 ms between chromatograms before alignment. In the second study of 42 chromatograms, the retention time shifting exhibited was on the order of 10 s between corresponding chromatographic peaks, and required a coarse retention time correction prior to alignment with the algorithm. In both cases, an increase in retention time precision afforded by the algorithm was clearly visible in plots of overlaid chromatograms before and then after applying the retention time alignment algorithm. Using the alignment algorithm, the standard deviation for corresponding peak retention times following alignment was 17 ms throughout a given chromatogram, corresponding to a relative standard deviation of 0.003% at an average retention time of 8 min. This level of retention time precision is a 5-fold improvement over the retention time precision initially provided by a state-of-the-art GC instrument equipped with electronic pressure control and was critical to the performance of the chemometric analysis. This increase in retention time precision does not come at the expense of chemical selectivity, since the PCA results suggest that essentially all of the chemical selectivity is preserved. Cluster resolution between dissimilar groups of diesel fuel chromatograms in a two-dimensional scores space generated with PCA is shown to substantially increase after alignment. The alignment method is robust against missing or extra peaks relative to a target chromatogram used in the alignment, and operates at high speed, requiring roughly 1 s of computation time per GC chromatogram.

Algorithms↗

Comprehensive two-dimensional gas chromatography of volatile and semi-volatile components using a diaphragm valve-based instrument.

A high-temperature configuration for a diaphragm valve-based gas chromatography (GCXGC) instrument is demonstrated. GCxGC is a powerful instrumental tool often used to analyze complex mixtures. Previously, the temperature limitations of valve-based GCxGC instruments were set by the maximum operating temperature of the valve, typically 175 degrees C. Thus, valve-based GCxGC was constrained to the analysis of mainly volatile components; however, many complex mixtures contain semi-volatile components as well. A new configuration is described that extends the working temperature range of diaphragm valve-based GCxGC instruments to significantly higher temperatures, so both volatile and semi-volatile compounds can be readily separated. In the current investigation, separations at temperatures up to 250 degrees C are demonstrated. This new design features both chromatographic columns in the same oven with the valve interfacing the two columns mounted in the side of the oven wall so the valve is both partially inside as well as outside the oven. The diaphragm and the sample ports in the valve are located inside the oven while the temperature-restrictive portion of the valve (containing the O-rings) is outside the oven. Temperature measurements on the surface of the valve indicate that even after a sustained oven temperature of 240 degrees C, the portions of the valve directly involved with the sampling from the first column to the second column track the oven temperature to within 1.2% while the portions of the valve that are temperature-restrictive remain well below the maximum temperature of 175 degrees C. A 26-component mixture of alkanes, ketones, and alcohols whose boiling points range from 65 degrees C (n-hexane) to 270 degrees C (n-pentadecane) is used to test the new design. Peak shapes along the first column axis suggest that sample condensation or carry-over in the valve is not a problem. Chemometric data analysis is performed to demonstrate that the resulting data have a bilinear structure. After over 6 months of use and temperature conditions up to 265 degrees C, no deterioration of the valve or its performance has been observed.

Chromatography, Gas↗