Search PubMed⌕ Search

Biomedical subjects

Kerstin Schmidt

Publications and source records attributed to Kerstin Schmidt.

9 recordsLinked to original sources

Differences in the transmigration of different dendritic cells.

OBJECTIVE: Although several methods for the generation of dendritic cells (DCs) exist, little is known about the transmigration capacities of the cells developed. Their ability to migrate to the adjacent lymphatic system is relevant since their efficacy does also rely on their potential to interact with lymphocytes. METHODS: We studied the transmigration of DCs derived from hematopoietic progenitor cells (HPC), from peripheral blood monocytes, and from leukemic cells. DCs from monocytes and leukemic cells could be generated within 1 week, whereas DCs from HPC needed 2 weeks for maturation. RESULTS: While DCs from all sources showed similar morphologic features and allostimulatory capacities, their transmigration capacities varied: HPC-derived DCs showed the highest migratory response to macrophage inflammatory protein (MIP)-3alpha and beta. Monocyte-derived DCs were equally attracted to MIP-3beta and stroma-derived factor (SDF)-1alpha. Only few leukemic DCs migrated in response to SDF-1. Other chemoattractants tested included MIP-1alpha and RANTES. Replacement of fetal bovine by human serum did not change the DC's overall migratory capacities. It did, however, influence the responsiveness to certain chemokines. CONCLUSION: Although DCs from all three sources are immunocompetent antigen-presenting cells, our findings suggest that HPC and monocyte-derived DCs can be administered subcutaneously and intravenously, but that leukemic DCs should be injected into the lymph node.

Cell Communication↗

Angiostatin overexpression in Morris hepatoma results in decreased tumor growth but increased perfusion and vascularization.

UNLABELLED: Growth of malignant tumors is dependent on sufficient blood supply. Thus, inhibition of tumor angiogenesis is emerging as a promising target in the treatment of malignancies. Human angiostatin (hANG) is one of the most potent inhibitors of endothelial cell proliferation, angiogenesis, and tumor growth in vivo. However, its mechanisms operating in vivo are not well understood. METHODS: To obtain more information about functional changes in the angiogenic process, we established Morris hepatoma (MH3924A) cell lines expressing hANG (hANG-MH3924A). The effects of hANG expression on proliferation and apoptosis of human umbilical vein endothelial cells (HUVECs) were measured in coculture experiments in vitro. To evaluate changes in tumor perfusion and blood volume, H2 15O and 68Ga-DOTA-albumin (DOTA is 1,4,7,10-tetraazacyclododecane-N,N',N'',N'''-tetraacetic acid) were used for PET studies in vivo. Additionally, immunohistologic quantification of vascularization, apoptosis, and proliferation as well as gene array analyses were performed. RESULTS: Our in vitro experiments demonstrate reduced proliferation and increased apoptosis in HUVECs when being cocultured with hANG-MH3924A. In support, tumor growth of hANG-MH3924A is diminished by 95% in vivo. However, tumor perfusion and blood volume are increased in hANG-MH3924A corresponding to an increased microvessel density. Furthermore, hANG-transfected tumors show changes in expression of genes related to apoptosis, stress, signal transduction, and metabolism. CONCLUSION: hANG expression leads to inhibition of tumor growth, increased apoptosis, and changes in the expression of multiple genes involved in stress reactions, signal transduction, and apoptosis, which indicates a multifactorial reaction of tumors. An enhanced microvessel density is seen as part of these reactions and is associated with increased perfusion as measured by PET.

Angiostatins↗

Troponin I overexpression inhibits tumor growth, perfusion, and vascularization of morris hepatoma.

UNLABELLED: Antiangiogenic gene transfer inhibiting growth of new blood vessels is a promising approach in cancer therapy. Human troponin I (TnI) efficiently inhibits endothelial cell proliferation, migration, as well as angiogenesis and tumor growth in vivo. However, little is known about its effects on perfusion and tumor biology. METHODS: Stable Morris hepatoma (MH3924A) cells overexpressing human TnI (TnI-MH3924A) were cocultured with human umbilical vein endothelial cells (HUVECs) followed by measurements of endothelial apoptosis and proliferation. Furthermore, tumor growth and perfusion were determined using H(2)(15)O and (68)Ga-DOTA-albumin (DOTA is 1,4,7,10-tetraazacyclododecane-N,N',N'',N'''-tetraacetic acid) PET as well as functional MRI. Additionally, histologic measurements of vascularization, apoptosis, proliferation, and gene array analyses were performed. RESULTS: Apoptosis of HUVECs was increased and proliferation was decreased after coculture with TnI-MH3924A cells. TnI-MH3924A tumors showed a significant inhibition of growth (90%) and a decreased perfusion (25%), whereas blood volume remained unchanged. MRI investigations demonstrated a significant decrease of the rate constant k(ep). Immunohistochemical analyses showed decreased microvessel density and proliferation and significant induction of apoptosis. Furthermore, TnI-expressing hepatomas demonstrated changes in the expression of genes related to angiogenesis, apoptosis, signal transduction, or stress. CONCLUSION: TnI regulates tumor growth by modulating vascularization including apoptosis induction and decrease of proliferation. In addition, changes in expression of genes associated with angiogenesis, apoptosis, signal transduction, or stress were found. The upregulation of angiogenesis and stress-related genes indicates a cross-talk of different mechanisms as part of the tumor's reaction to TnI. Because the decrease of vascularization led to lower perfusion values as measured by PET and MRI, these noninvasive methods are promising tools for the monitoring of antiangiogenic gene therapy.

Animals↗

Transfer of the sFLT-1 gene in Morris hepatoma results in decreased growth and perfusion and induction of genes associated with stress response.

PURPOSE: Inhibition of tumor angiogenesis is emerging as a promising target in the treatment of malignancies. Therefore, monitoring of antiangiogenic approaches with functional imaging and histomorphometrical analyses are desirable to evaluate the biological effects caused by this treatment modality. EXPERIMENTAL DESIGN: Using a bicistronic retroviral vector for transfer of the soluble receptor for the vascular endothelial growth factor (sFLT) hepatoma (MH3924A) cell lines with sFLT expression were generated. In human umbilical vein endothelial cells cultured with conditioned medium of sFLT-expressing hepatoma cells, the inhibitory action of secreted sFLT was determined using a Coulter counter and a thymidine incorporation assay. Furthermore, in vivo experiments were done to measure the effects on tumor growth and perfusion. Finally, the tumors were examined by immunohistochemistry (including computer-assisted morphometry) and DNA chip analysis. RESULTS: Stable sFLT-expressing hepatoma cells inhibited endothelial cell proliferation in vitro. In vivo, growth and perfusion, as measured by H(2)(15)O positron emission tomography, were reduced in genetically modified tumors. However, the immunohistochemically quantified microvascularization and macrovascularization, as indicated by CD31- and alpha-actin-positive area, revealed no significant changes, whereas the number of apoptotic cells was increased in sFLT-expressing tumors, although not significantly. DNA chip analysis of tumors with gene transfer showed an increase of genes related to apoptosis, signal transduction, and oxidative stress. CONCLUSION: Our results suggest that sFLT expression inhibits tumor growth and perfusion and enhances expression of apoptosis-related genes in this model. Enhanced expression of genes for signal transduction, stress, and metabolism indicates tumor defense reactions.

Animals↗

Improved correlation of histological data with DCE MRI parameter maps by 3D reconstruction, reslicing and parameterization of the histological images.

Due to poor correlation of slice thickness and orientation, verification of radiological methods with histology is difficult. Thus, a procedure for three-dimensional reconstruction, reslicing and parameterization of histological data was developed, enabling a proper correlation with radiological data. Two different subcutaneous tumors were examined by MR microangiography and DCE-MRI, the latter being post-processed using a pharmacokinetic two-compartment model. Subsequently, tumors were serially sectioned and vessels stained with immunofluorescence markers. A ray-tracing algorithm performed three-dimensional visualization of the histological data, allowing virtually reslicing to thicker sections analogous to MRI slice geometry. Thick slices were processed as parameter maps color coding the marker density in the depth of the slice. Histological 3D reconstructions displayed the diffuse angioarchitecture of malignant tumors. Resliced histological images enabled specification of high enhancing areas seen on MR microangiography as large single vessels or vessel assemblies. In orthogonally reconstructed histological slices, single vessels were delineated. ROI analysis showed significant correlation between histological parameter maps of vessel density and MR parameter maps (r=0.83, P=0.05). The 3D approach to histology improves correlation of histological and radiological data due to proper matching of slice geometry. This method can be used with any histological stain, thus enabling a multivariable correlation of non-invasive data and histology.

Algorithms↗

Gallium-68-DOTA-albumin as a PET blood-pool marker: experimental evaluation in vivo.

Investigations into tumor angiogenesis and antiangiogenic treatment have renewed interest in tumor perfusion. To image tumor blood-pool by PET, suitable tracers are not generally available. In this experimental study, we characterized a 68Ga-labeled 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA) conjugate of rat serum albumin (68Ga-DOTA-RSA) in vivo using a generator-produced isotope. Biodistribution was determined in ACI rats after intravenous administration of 3-6 MBq of 68Ga-DOTA-RSA. Three ACI rats were imaged over 1 h by dynamic PET after intravenous administration of 15-25 MBq of 68Ga-DOTA-RSA while the blood-pool activity was recorded simultaneously in a closed extracorporeal loop (ECL) between the carotid artery and the jugular vein. Time-activity curves (TACs) were obtained from volume of interest (VOI) analysis and from the ECL data. Stability and metabolites in plasma and urine were analyzed by size exclusion HPLC (SE-HPLC) 1 h after intravenous injection of 67Ga-DOTA-RSA. Blood radioactivity decreased by 10% and 18% from 10 to 60 min p.i. by biodistribution and PET or ECL, respectively. Tissue sampling between 10 and 60 min p.i. showed slight increases in the uptake of spleen, myocardium, kidney and skeletal muscle while hepatic accretion remained unchanged. Total urinary excretion after 60 min amounted to 9% of the injected dose. HPLC demonstrated a single urinary metabolite corresponding in size to gallium-labeled DOTA. 68Ga-DOTA-RSA is a blood-pool tracer whose physical and biological half-life is well suited for PET. Our findings support clinical imaging using 68Ga-DOTA-labeled human serum albumin (HSA). The generator-produced label makes 68Ga-DOTA-labeled albumin continuously available even to centers lacking an in-house cyclotron.

Animals↗

Precise placement of multiple electrodes into functionally predefined cortical locations.

Current research on topics such as effective connectivity, neuronal coding strategy or signal propagation in the central nervous system requires simultaneous recordings from multiple sites within functionally grouped but topologically distributed neuronal clusters. We have addressed this issue by characterization of the cortical functional architecture using optical imaging of intrinsic signals (OI) and subsequent placement of multiple, individually adjustable electrodes into pre-selected domains. In order to achieve maximum precision and flexibility for the positioning of electrodes, a plastic cylinder containing channels of an extremely high aspect ratio (density >20 channels/mm(2)) was fixed above the cortex and individual channel positions were superimposed onto the functional maps of orientation columns obtained previously with OI. Subsequently, channels corresponding to the desired locations in the functional map were used as guide tubes for electrode insertion. The spatial precision of this approach was in the range of 100 microm and experiments in cat primary visual cortex revealed a close correlation between the desired and the actually recorded orientation preferences of the targeted columns. The method is applicable to all cortical areas in which OI is feasible and offers a high degree of flexibility with respect to the number and geometry of applicable probes. It is, thus, an excellent tool for studying distributed codes and interactions between multiple predefined recording sites.

Animals↗

Agonist properties of putative small-molecule somatostatin sst2 receptor-selective antagonists.

The availability of antagonist ligands for somatostatin receptors is very limited, with those that are available often displaying agonist properties or limited receptor subtype selectivity. Hay et al. [Bioorg. Med. Chem. Lett. 11 (2001) 2731] recently described the development of small-molecule somatostatin receptor subtype 2 (sst(2)) selective compounds. This study investigates the binding affinity and functional characteristics of two of those antagonists (2 and 3) and the agonist compound, from which they were derived (1). In radioligand binding studies using the agonist radioligands [125I][Tyr(11)]SRIF-14 (Ala-Gly-c[Cys-Lys-Asn-Phe-Phe-Trp-Lys-Thr-(125I-Tyr)-Thr-Ser-Cys]-OH), [125I]LTT-SRIF-28 ([Leu(8),DTrp(22),125I-Tyr(25)]SRIF-28; Ser-Ala-Asn-Ser-Asn-Pro-Ala-Leu-Ala-Pro-Arg-Glu-Arg-Lys-Ala-Gly-c[Cys-Lys-Asn-Phe-Phe-DTrp-Lys-Thr-(125I-Tyr)-Thr-Ser-Cys]-OH), [125I]CGP 23996 (c[Lys-Asu-Phe-Phe-Trp-Lys-Thr-(125I-Tyr)-Thr-Ser]), [125I][Tyr(3)]octreotide (DPhe-c[Cys-(125I-Tyr)-DTrp-Lys-Thr-Cys]-Thr-OH) and [125I][Tyr(10)]cortistatin-14 (Pro-c[Cys-Lys-Asn-Phe-Phe-Trp-Lys-Thr-(125I-Tyr)-Ser-Ser-Cys]-Lys) at human recombinant somatostatin receptors expressed in Chinese hamster lung fibroblast (CCL39) cells and native rat cortex, the compounds bound with high affinity (pK(d) 6.8-9.7) and selectivity to human sst(2) receptors. Some affinity was also observed for sst(5) labelled by [125I][Tyr(3)]octreotide and [125I]CGP 23996. In functional studies at human sst(2) receptors expressed in Chinese hamster ovary (CHO) cells, both the agonist 1 and the two putative antagonists 2 and 3 concentration dependently inhibited forskolin-stimulated adenylate cyclase and stimulated luciferase reporter gene expression, with similar efficacy to the natural ligand somatotropin release inhibiting factor (SRIF)-14. Compound 1 had similar potency to SRIF-14, which was in the nanomolar range, whereas 2 and 3 were 10-100-fold less potent. The intrinsic activity of 2 and 3 was too high to allow antagonist studies to be carried out. In conclusion, in contrast to previous findings, all three compounds are potent agonists at recombinant human sst(2) receptors.

Adenylyl Cyclases↗

A multivessel model describing replenishment kinetics of ultrasound contrast agent for quantification of tissue perfusion.

To improve the quantification of tissue perfusion using intermittent sonography, a new model describing replenishment kinetics of microbubbles is proposed. The new approach takes into account the variability of blood flow velocities found in vivo, especially in tumors, and consistently describes the refilling process of microbubbles. Based upon this model, blood volume, blood velocity, blood flow and perfusion in 17 experimental tumors were calculated, and compared with the results obtained with the established, phenomenologically derived exponential kinetic model. In contrast to the existing model, our approach describes tissue vascularization more physiologically and allows deduction of a consistent new hyperbolic model for quantification of intermittent sonography. Blood volume and mean blood velocity did significantly correlate between both the new and the established model (k=0.99; k=0.94, both p<0.001). However, mean tumor blood velocity was lower (-19%, p<0.01) with the established model compared to the newly developed model. In addition, the range and distribution of blood flow velocities found in vivo can be estimated with the new model. Furthermore, it uses simpler mathematical fitting routines and allows easier data acquisition, which may allow a more practicable clinical application of intermittent sonography. In conclusion, a more valid, detailed and accurate calculation of perfusion parameters, especially of tumors, can be derived in vivo with the new multivessel model of intermittent sonography.

Animals↗