Search PubMed⌕ Search

Biomedical subjects

Kenneth R Wehmeyer

Publications and source records attributed to Kenneth R Wehmeyer.

12 recordsLinked to original sources

Unlimited-volume electrokinetic stacking injection in sweeping capillary electrophoresis using a cationic surfactant.

Sweeping is an effective and convenient way for online sample preconcentration in micellar electrokinetic chromatography. The usual procedure includes a hydrodynamic injection step carried out by applying pressure to the sample vial followed by the subsequent sweeping and separation processes. The injected sample volume is limited by the dimensions of the capillary because a part of the capillary has to be left free of sample solution for the subsequent sweeping and separation steps. In addition, when a short capillary, such as 4-10 cm, is used for sweeping, the injected sample volume is small even if the entire capillary is filled with sample solution. To solve this problem, an electrokinetic stacking injection (EKSI) scheme was developed by using a cationic surfactant, dodecyltrimethylammonium bromide, for sweeping in capillary electrophoresis. An experimental model was proposed, and the entire process was theoretically analyzed. According to the theoretical discussion, the optimal conditions for two model analytes, 5-carboxyfluorescein (5-FAM) and sodium fluorescein (FL), were experimentally determined. The injected sample plug lengths for 5-FAM and FL under 20.1 kV for 60 min were experimentally estimated as 836 and 729 cm, corresponding to 28- and 24-fold the effective capillary length, respectively. The EKSI scheme resulted in increased detection factors for 5-FAM and FL of 4.5 x 10(3) and 4.0 x 10(3) using 60-min injection relative to a traditional pressure injection.

Cations↗

On-line sample preconcentration by sweeping with dodecyltrimethylammonium bromide in capillary zone electrophoresis.

On-line sample preconcentration of oligonucleotides with a new sweeping carrier was developed by using dodecyltrimethylammonium bromide (DTAB) below the critical micelle concentration (CMC). The sweeping results with DTAB below and above the CMC were compared. The use of DTAB below the CMC benefits the preconcentration of the oligonucleotides, while the use of DTAB above the CMC is good for hydrophobic small molecules. The factors affecting the sweeping results were optimized and this method was evaluated by constructing calibration curves for thrombin aptamers. The sweeping scheme produced a 112-fold sensitivity enhancement for the oligonucleotides relative to that run in a running buffer without DTAB. The sweeping method developed here can be a good reinforcement of the preconcentration scheme by sweeping when less-hydrophobic analytes or large negatively-charged molecules need to be preconcentrated.

Acetonitriles↗

On-line sample preconcentration using field-amplified stacking injection in microchip capillary electrophoresis.

Previous reports describing sample stacking on microchip capillary electrophoresis (microCE) have regarded the microchip channels as a closed system and treated the bulk flow as in traditional capillary electrophoresis. This work demonstrates that the flows arising from the intersection should be investigated as an open system. It is shown that the pressure-driven flows into or from the branch channels due to bulk velocity mismatch in the main channel should not be neglected but can be used for liquid transportation in the channels. On the basis of these concepts, a sample preconcentration scheme was developed in a commercially available single-cross glass chip for microCE. Similar to field-amplified stacking injection in traditional CE, a low conductivity sample buffer plug was introduced into the separation channel immediately before the negatively charged analyte molecules were injected. The detection sensitivity was improved by 94-, 108-, and 160-fold for fluorescein-5-isothiocyanate, fluorescein disodium, and 5-carboxyfluorescein, respectively, relative to a traditional pinched injection. The calibration curves for fluorescein and 5-carboxyfluorescein demonstrated good linearity in the concentration range (1-60 nM) investigated with acceptable reproducibility of migration time and peak height and area ratios (4-5% RSD). This preconcentration scheme will be of particular significance to the practical use of microCE in the emerging miniaturized analytical instrumentation.

Buffers↗

Modifications of the human urocortin 2 peptide that improve pharmacological properties.

Recently, we demonstrated that the corticotropin releasing factor 2 receptor agonist, urocortin 2, demonstrated anti-atrophy effects in rodent skeletal muscle atrophy models. Compared to other CRF2R agonists however, the in vivo pharmacological potency of urocortin 2 is poor when it is administered by continuous subcutaneous infusion. Therefore, we attempted to modify the structure of urocortin 2 to improve in vivo efficacy when administered by subcutaneous infusion. By substituting amino acid residues in the linker region of urocortin 2 (residues 22-32), we have demonstrated improved in vivo potency without altering selectivity, probably through reduced CRFBP binding. In addition, attempts to shorten urocortin 2 generally resulted in inactive peptides, demonstrating that the 38 amino acid urocortin 2 peptide is the minimal pharmacophore.

Amino Acid Sequence↗

Analytical performance of polymer-based microfluidic devices fabricated by computer numerical controlled machining.

A study comparing the electrophoretic separation performance attainable from microchips molded by masters fabricated using conventional CNC machining techniques with commercial microchips, wire imprinted microchips, and microchips from LIGA molding devices is presented. An electrophoresis-based detection system using fluorescence microscopy was used to determine the analytical utility of these microchips. The separation performance of CNC microchips was comparable to commercially available microchips as well as those fabricated from LIGA masters. The important feature of the CNC machined masters is that they have rapid design-to-device times using routinely available machining tools. This low-cost prototyping approach provides a new entry point for researchers interested in thermoplastic microchips and can accelerate the development of polymer-based lab-on-a-chip devices.

Computer-Aided Design↗

Estimation of pK(a) values using microchip capillary electrophoresis and indirect fluorescence detection.

Microchip capillary electrophoresis (CE), coupled with indirect fluorescence detection was investigated for estimating the pK(a) values of non-fluorescent compounds. The CE method is based on the differences in electrophoretic mobility of the analyte as a function of the pH of the running buffer. Nine compounds were tested, including several of pharmaceutical importance, with pK(a) values from 10.3 to 4.6. All buffers contained 5-TAMRA as the fluorescent probe for indirect detection. Calculated pK(a) values agreed well with literature values obtained by traditional methods, differing not more than 0.2 from the literature value. The current work on single lane chips demonstrates the principle of microchip CE with indirect detection as a viable method for estimating pK(a) values. However, increased throughput will be required using a multilane chip to enable the approach to be used practically.

Aniline Compounds↗

Estimation of logP(ow) values for neutral and basic compounds by microchip microemulsion electrokinetic chromatography with indirect fluorimetric detection (muMEEKC-IFD).

Microchip microemulsion electrokinetic chromatography with indirect fluorimetric detection (muMEEKC-IFD) was used to obtain logP octanol/water (logP(ow)) values for neutral and basic compounds. Six compounds, with logP(ow) values between 0.38 and 5.03, were used to create a calibration curve relating the log of retention factors (logk) obtained from muMEEKC-IFD with the known logP(ow) values. The logP(ow) values for six additional compounds were determined using the logk values obtained by muMEEKC-IFD and the linear relationship between logP(ow) and logk established for the standard compounds. The muMEEKC-IFD buffer was composed of 50 mM 3-[cyclohexylamino]-1-propane-sulfonic acid (CAPS) buffer (pH 10.4) containing 1.2% n-heptane (v/v), 2% sodium dodecylsulfate (w/v), 8% 1-butanol (v/v) and 4 microM 5-carboxytetramethyl-rhodamine (TAMRA) as the fluorophore probe for indirect detection. The muMEEKC-IFD provided an accurate method for estimating logP(ow) values and also a means for analyzing compounds that are non-fluorescent.

Calibration↗

Rapid pKa estimation using vacuum-assisted multiplexed capillary electrophoresis (VAMCE) with ultraviolet detection.

A rapid approach for estimating the pK(a) value of small organic molecules was developed using vacuum-assisted multiplexed capillary electrophoresis (VAMCE) with ultraviolet detection. The VAMCE method employed a 96-capillary array, arranged in a standard 8 x 12 microtiter plate configuration, with each row of capillaries filled with 12 individual running buffers of equal ionic strength (I = 50 mM) covering a pH range from 2.2 to 10.7. A separate compound was injected hydrodynamically into each row of capillaries allowing the estimation of pK(a) values for eight compounds in a single run. The application of a vacuum during the separation generated a bulk fluid flow and allowed the electrophoretic separation to be completed within 5 min. The complete VAMCE method, conditioning, and electrophoretic separation was optimized to allow the pK(a) estimation for between 128 to 168 compounds in an 8-h period. The VAMCE method provided a reliable approach for estimating pK(a) values both within- and between-day. The pK(a) values for a series of 96 compounds estimated by VAMCE agreed well with some of literature pK(a) values with an average absolute difference of 0.22 log units.

Electrophoresis, Capillary↗

On-line solid phase extraction using the Prospekt-2 coupled with a liquid chromatography/tandem mass spectrometer for the determination of dextromethorphan, dextrorphan and guaifenesin in human plasma.

An on-line liquid chromatography/tandem mass spectrometry (LC-MS/MS) procedure, using the Prospekt- 2 system, was developed and used for the determination of the levels of the active ingredients of cough/cold medications in human plasma matrix. The experimental configuration allows direct plasma injection by performing on- line solid phase extraction (SPE) on small cartridge columns prior to elution of the analyte(s) onto the analytical column and subsequent MS/MS detection. The quantitative analysis of three analytes with differing polarities, dextromethorphan (DEX), dextrorphan (DET) and guaifenesin (GG) in human plasma presented a significant challenge. Using stable-isotope-labeled internal standards for each analyte, the Prospekt-2 on-line methodology was evaluated for sensitivity, suppression, accuracy, precision, linearity, analyst time, analysis time, cost, carryover and ease of use. The lower limit of quantitation for the on-line SPE procedure for DEX, DET and GG was 0.05, 0.05 and 5.0 ng mL(-1), respectively, using a 0.1 mL sample volume. The linear range for DEX and DET was 0.05-50 ng mL(-1) and was 5-5,000 ng mL(-1) for GG. Accuracy and precision data for five different levels of QC samples were collected over three separate days. Accuracy ranged from 90% to 112% for all three analytes, while the precision, as measured by the %RSD, ranged from 1.5% to 16.0%

Antitussive Agents↗

Application of multiplexed capillary electrophoresis with laser-induced fluorescence (MCE-LIF) detection for the rapid measurement of endogenous extracellular signal-regulated protein kinase (ERK) levels in cell extracts.

Multiplexed (96-lane) capillary electrophoresis with laser-induced fluorescence (MCE-LIF) detection was used for the rapid analysis of extracellular signal-regulated protein kinase (ERK) levels from in vitro cell extracts. The levels of ERK enzyme in cell extracts were determined by monitoring the conversion of a fluorescent-labeled peptide substrate to a phosphorylated fluorescent-labeled peptide product using MCE-LIF. The incorporation of a fluorescent internal standard was found to improve the precision of the analysis. The enzyme assay conditions including substrate concentration, reaction time and enzyme linear range were rapidly optimized using the MCE-LIF approach for both direct and immunoprecipitation-based ERK assays. The levels of ERK from in vitro cell extracts stimulated with angiopoietin 1 (Ang1*) were determined using the MCE-LIF approach. The advantages of MCE-LIF for developing and applying enzyme assays, as well as the figures of merit for the direct and immunoprecipitation ERK assays, are discussed.

Cell Extracts↗

Determination of endogenous extracellular signal-regulated protein kinase by microchip capillary electrophoresis.

The application of microchip capillary electrophoresis (CE) to the assay of extracellular signal-regulated protein kinase (ERK) is presented. In this assay, ERK catalyzes the transfer of gamma-phosphate from adenosine 5(')-triphosphate to the threonine residue of a fluorescently labeled nonapeptide (APRTPGGRR), and the phosphorylated and nonphosphorylated peptides were detected by fluorescence. The phosphorylated and nonphosphorylated peptides and the internal standard were separated within 20s, and the increase in magnitude of the phosphorylated peptide peak was monitored to assess ERK activity. ERK reactions were prepared off-chip and analyzed on a single-lane glass microchip fabricated by standard methods. It was demonstrated that microchip CE could be used to measure endogenous amounts of ERK by spiking known concentrations of recombinant ERK2 into the lysates of serum-starved human umbilical vein endothelial cells (HUVEC) and recovering between 90 and 100% for all samples. Endogenous ERK activity was determined by microchip where HUVEC were stimulated with 500pM vascular endothelial growth factor (VEGF) at different times before cell lysis. The results showed a transient VEGF-mediated ERK activation that peaked at 10min, which was consistent with previous reports using conventional techniques. The microchip assay provided a rapid, accurate, and precise alternative to conventional methods of determining endogenous ERK activity.

Cells, Cultured↗

Semi-automated liquid--liquid back-extraction in a 96-well format to decrease sample preparation time for the determination of dextromethorphan and dextrorphan in human plasma.

A semi-automated, 96-well based liquid-liquid back-extraction (LLE) procedure was developed and used for sample preparation of dextromethorphan (DEX), an active ingredient in many over-the-counter cough formulations, and dextrorphan (DOR), an active metabolite of DEX, in human plasma. The plasma extracts were analyzed by liquid chromatography-tandem mass spectrometry (LC-MS-MS). The analytes were isolated from human plasma using an initial ether extraction, followed by a back extraction from the ether into a small volume of acidified water. The acidified water isolated from the back extraction was analyzed directly by LC-MS-MS, eliminating the need for a dry down step. A liquid handling system was utilized for all aspects of liquid transfers during the LLE procedure including the transfer of samples from individual tubes into a 96-well format, preparation of standards, addition of internal standard and the addition and transfer of the extraction solvents. The semi-automated, 96-well based LLE procedure reduced sample preparation time by a factor of four versus a comparable manually performed LLE procedure.

Automation↗