Search PubMed⌕ Search

Biomedical subjects

Kenneth K Kwong

Publications and source records attributed to Kenneth K Kwong.

12 recordsLinked to original sources

Functional imaging of working memory in obstructive sleep-disordered breathing.

Functional magnetic resonance imaging was used to map cerebral activation in 16 patients with obstructive sleep-disordered breathing (OSDB) and 16 healthy subjects, during the performance of a 2-back verbal working memory task. Six patients with OSDB were reimaged after a minimum period of 8 wk of treatment with positive airway pressure. Working memory speed in OSDB was significantly slower than in healthy subjects, and a group average map showed absence of dorsolateral prefrontal activation, regardless of nocturnal hypoxia. After treatment, resolution of subjective sleepiness contrasted with no significant change in behavioral performance, persistent lack of prefrontal activation, and partial recovery of posterior parietal activation. These findings suggest that working memory may be impaired in OSDB and that this impairment is associated with disproportionate impairment of function in the dorsolateral prefrontal cortex. Nocturnal hypoxia may not be a necessary determinant of cognitive dysfunction, and sleep fragmentation may be sufficient. There may be dissociations between respiratory vs. cortical recovery and objective vs. subjective recovery. Hypofrontality may provide a plausible biological mechanism for a clinical overlap with disorders of mood and attention.

Adult↗

Effects of electroacupuncture versus manual acupuncture on the human brain as measured by fMRI.

The goal of this functional magnetic resonance imaging (fMRI) study was to compare the central effects of electroacupuncture at different frequencies with traditional Chinese manual acupuncture. Although not as time-tested as manual acupuncture, electroacupuncture does have the advantage of setting stimulation frequency and intensity objectively and quantifiably. Manual acupuncture, electroacupuncture at 2 Hz and 100 Hz, and tactile control stimulation were carried out at acupoint ST-36. Overall, electroacupuncture (particularly at low frequency) produced more widespread fMRI signal increase than manual acupuncture did, and all acupuncture stimulations produced more widespread responses than did our placebo-like tactile control stimulation. Acupuncture produced hemodynamic signal increase in the anterior insula, and decrease in limbic and paralimbic structures including the amygdala, anterior hippocampus, and the cortices of the subgenual and retrosplenial cingulate, ventromedial prefrontal cortex, frontal, and temporal poles, results not seen for tactile control stimulation. Only electroacupuncture produced significant signal increase in the anterior middle cingulate cortex, whereas 2-Hz electroacupuncture produced signal increase in the pontine raphe area. All forms of stimulation (acupuncture and control) produced signal increase in SII. These findings support a hypothesis that the limbic system is central to acupuncture effect regardless of specific acupuncture modality, although some differences do exist in the underlying neurobiologic mechanisms for these modalities, and may aid in optimizing their future usage in clinical applications.

Acupuncture Points↗

Voxel-based analysis of MRI detects abnormal visual cortex in children and adults with amblyopia.

Amblyopia, sometimes called "lazy eye," is a relatively common developmental visual disorder well characterized behaviorally; however, the neural substrates associated with amblyopia in humans remain unclear. We hypothesized that abnormalities in the cerebral cortex of subjects with amblyopia exist, possibly as a result of experience-dependent neuronal plasticity. Anatomic magnetic resonance imaging (MRI) and psychophysical vision testing was carried out on 74 subjects divided into two age ranges, 7-12 years and 18-35 years, and three diagnoses, strabismic amblyopia, anisometropic amblyopia, and normal vision. We report a behavioral impairment in contrast sensitivity for subjects with amblyopia, consistent with previous reports. When the high-resolution MRI brain images were analyzed quantitatively with optimized voxel-based morphometry, results indicated that adults and children with amblyopia have decreased gray matter volume in visual cortical regions, including the calcarine sulcus, known to contain primary visual cortex. This finding was confirmed with a separate region-of-interest analysis. For the children with amblyopia, additional gray matter reductions in parietal-occipital areas and ventral temporal cortex were detected, consistent with recent reports that amblyopia can result in spatial location and object processing deficits. These data are the first to provide possible neuroanatomic bases for the loss of binocularity and visual sensitivity in children and adults with amblyopia.

Adolescent↗

Functional MRI using regularized parallel imaging acquisition.

Parallel MRI techniques reconstruct full-FOV images from undersampled k-space data by using the uncorrelated information from RF array coil elements. One disadvantage of parallel MRI is that the image signal-to-noise ratio (SNR) is degraded because of the reduced data samples and the spatially correlated nature of multiple RF receivers. Regularization has been proposed to mitigate the SNR loss originating due to the latter reason. Since it is necessary to utilize static prior to regularization, the dynamic contrast-to-noise ratio (CNR) in parallel MRI will be affected. In this paper we investigate the CNR of regularized sensitivity encoding (SENSE) acquisitions. We propose to implement regularized parallel MRI acquisitions in functional MRI (fMRI) experiments by incorporating the prior from combined segmented echo-planar imaging (EPI) acquisition into SENSE reconstructions. We investigated the impact of regularization on the CNR by performing parametric simulations at various BOLD contrasts, acceleration rates, and sizes of the active brain areas. As quantified by receiver operating characteristic (ROC) analysis, the simulations suggest that the detection power of SENSE fMRI can be improved by regularized reconstructions, compared to unregularized reconstructions. Human motor and visual fMRI data acquired at different field strengths and array coils also demonstrate that regularized SENSE improves the detection of functionally active brain regions.

Brain Mapping↗

The integrated response of the human cerebro-cerebellar and limbic systems to acupuncture stimulation at ST 36 as evidenced by fMRI.

Clinical and experimental data indicate that most acupuncture clinical results are mediated by the central nervous system, but the specific effects of acupuncture on the human brain remain unclear. Even less is known about its effects on the cerebellum. This fMRI study demonstrated that manual acupuncture at ST 36 (Stomach 36, Zusanli), a main acupoint on the leg, modulated neural activity at multiple levels of the cerebro-cerebellar and limbic systems. The pattern of hemodynamic response depended on the psychophysical response to needle manipulation. Acupuncture stimulation typically elicited a composite of sensations termed deqi that is related to clinical efficacy according to traditional Chinese medicine. The limbic and paralimbic structures of cortical and subcortical regions in the telencephalon, diencephalon, brainstem and cerebellum demonstrated a concerted attenuation of signal intensity when the subjects experienced deqi. When deqi was mixed with sharp pain, the hemodynamic response was mixed, showing a predominance of signal increases instead. Tactile stimulation as control also elicited a predominance of signal increase in a subset of these regions. The study provides preliminary evidence for an integrated response of the human cerebro-cerebellar and limbic systems to acupuncture stimulation at ST 36 that correlates with the psychophysical response.

Acupuncture↗

Parallel imaging reconstruction using automatic regularization.

Increased spatiotemporal resolution in MRI can be achieved by the use of parallel acquisition strategies, which simultaneously sample reduced k-space data using the information from multiple receivers to reconstruct full-FOV images. The price for the increased spatiotemporal resolution in parallel MRI is the degradation of the signal-to-noise ratio (SNR) in the final reconstructed images. Part of the SNR reduction results when the spatially correlated nature of the information from the multiple receivers destabilizes the matrix inversion used in the reconstruction of the full-FOV image. In this work, a reconstruction algorithm based on Tikhonov regularization is presented that reduces the SNR loss due to geometric correlations in the spatial information from the array coil elements. Reference scans are utilized as a priori information about the final reconstructed image to provide regularized estimates for the reconstruction using the L-curve technique. This automatic regularization method reduces the average g-factors in phantom images from a two-channel array from 1.47 to 0.80 in twofold sensitivity encoding (SENSE) acceleration. In vivo anatomical images from an eight-channel system show an averaged g-factor reduction of 1.22 to 0.84 in 2.67-fold acceleration.

Algorithms↗

In vivo study of microbubbles as an MR susceptibility contrast agent.

The potential application of gas microbubbles as a unique intravascular susceptibility contrast agent for MRI has not been fully explored. In this study, the MR susceptibility effect of an ultrasound microbubble contrast agent, Optison, was studied with rat liver imaging at 7 T. Optison suspension in two different doses (0.15 mL/kg and 0.4 mL/kg) was injected into rats, and induced transverse relaxation rate increases (deltaR2*) of 29.1 +/- 1.6 s(-1) (N = 2) and 61.5 +/- 12.9 s(-1) (N = 6), respectively, in liver tissue. Liver uptake of intact albumin microbubbles was observed 10 min after injection. Eight of the 16 rats studied showed no susceptibility enhancement. This is probably attributable to the intravascular microbubble growth due to transmural CO2 supersaturation in the cecum and colon in small animals that causes microbubble aggregation and trapping in the inferior vena cava (IVC). In vitro deltaR2* measurements of Optison suspension at different concentrations are also reported.

Albumins↗

MRI of blood volume with superparamagnetic iron in choroidal melanoma treated with thermotherapy.

Functional magnetic resonance imaging (MRI) with a new intravascular contrast agent, monocrystalline iron oxide nanoparticles (MION), was applied to assess the effect of transpupillary thermotherapy in a rabbit model of choroidal melanoma. 3D-spoiled gradient recalled sequences were used for quantitative assessment of blood volume. The MRI-parameters were 5/22/35 degrees (time of repetition (TR)/echo delay (TE)/flip angle (FA)) for T(1)- and 50/61/10 degrees for T(2)-weighted sequences. Images were collected before and at different times after MION injection. In all untreated tissues studied, MION reduced the T(2)-weighted signal intensity within 0.5 h and at 24 h (all p <== 0.012), whereas no significant changes were detected in treated tumors. T(1)-weighted images also revealed differences of MION-related signal changes between treated tumors and other tissues, yet at lower sensitivity and specificity than T(2). The change of T(2)-weighted MRI signal caused by intravascular MION allows early distinction of laser-treated experimental melanomas from untreated tissues. Further study is necessary to determine whether MRI can localize areas of tumor regrowth within tumors treated incompletely.

Animals↗

Neuroanatomy of adult strabismus: a voxel-based morphometric analysis of magnetic resonance structural scans.

Cerebral deficit has been implicated in the genesis of strabismus and in the mechanisms adopted to compensate for the visual disorder. Voxel-based morphometry (VBM) was applied to magnetic resonance images of strabismic adults to detect any abnormal brain anatomy, which could not be easily identified by simple inspection. The gray matter volume in strabismic adults was smaller than that in normal subjects at the areas consistent with the occipital eye field (OEF) and parietal eye field (PEF). However, greater gray matter volume was found in strabismic adults relative to normal controls at the areas consistent with the frontal eye field (FEF), the supplementary eye field (SEF), the prefrontal cortex (PFC), and subcortical regions such as the thalamus and the basal ganglia. These opposite gray matter changes in the visual and the oculomotor processing areas are compatible with a hypothesis of plasticity in the oculomotor regions to compensate for the cortical deficits in the visual processing areas.

Adult↗

Degenerate mode birdcage volume coil for sensitivity-encoded imaging.

A volume birdcage coil for accelerated image encoding with parallel acquisition methods such as SENSE is demonstrated. The coil is degenerately tuned with both the standard homogeneous mode and the first gradient mode of the birdcage coil resonant at the Larmor frequency. Conventional and antisymmetric coupling structures allow imaging from each of these modes simultaneously. The coil for SENSE-type reconstruction with acceleration factors of up to 2-fold is demonstrated. The spatial distribution of the added noise from the SENSE reconstruction (g-factor map) due to geometrical arrangement of the two-channel system is estimated. The spatially averaged g-factors were found to be 1.21, 1.36, and 1.55 for 1.3, 1.6, and 2-fold accelerations, respectively. The system was demonstrated in vivo using accelerated and nonaccelerated anatomical brain images at 1.5 T. The maximal 2-fold acceleration in this dual-mode degenerate birdcage coil offers the potential to extend SENSE-type image reconstruction methods to applications demanding uniform whole brain coverage.

Brain↗

MRI of blood volume with MS 325 in experimental choroidal melanoma.

Functional magnetic resonance imaging (MRI) allows quantitative blood volume imaging in vivo at high tissue resolution. The purpose is to apply this technique for untreated and hyperthermia-treated experimental choroidal melanoma. MS 325 was used as new intravascular albumin-bound gadolinium-based contrast agent. Pigmented choroidal melanomas were established in albino rabbits. MRI was performed in 7 untreated eyes and 7 eyes treated with a Neodymium:Yttrium-Lanthanum-Fluoride-laser at 1047 nm. 3D-spoiled gradient echo pulse sequences were used to acquire T' weighted axial images. First, a set of images was collected without contrast agent. MS 325 was then injected i.v. and images were obtained within 12 min after injection. Signal intensities were measured within tumor, ciliary body, choroid, and iris and relative signal intensities were determined for these tissues in relation to vitreous. In untreated tumors, the relative signal intensity was higher after injection of MS 325 (5.61+0.70) than without MS 325 (2.90+0.33; p = 0.0002). In contrast, the relative signal intensity of treated tumors did not differ significantly before and after MS 325 (6.19+1.59 and 6.13+1.64). Histopathological sections indicated vascular occlusion in treated tumors. All other studied tissues of untreated and treated eyes showed a significant increase of relative signal intensities in the presence of MS 325. An animal model for the research on contrast agents in MRI is presented. Blood volume measurement with MS 325 was adapted for experimental choroidal melanomas. Reduced change of relative signal intensity indicates compromised blood volume after vascular occlusion in hyperthermia-treated melanoma. Further studies are needed to investigate whether this technique allows the evaluation of tumor viability following treatments.

Animals↗

MRI of blood volume and cellular uptake of superparamagnetic iron in an animal model of choroidal melanoma.

Functional magnetic resonance imaging (MRI), using monocrystalline iron oxide nanoparticles (MION) as a new intravascular contrast agent, was adapted for a rabbit model of pigmented choroidal melanoma. Three-dimensionally spoiled gradient recalled sequences were used for the quantitative assessment of blood volume and cellular uptake. In all ocular tissues studied, MION reduced the T(2)-weighted signal intensity within 0.5 h and at 24 h (both p < 0.05) after the injection. In individual tumors, MION reduced the T(2)-weighted signal intensity by 46-78% within 0.5 h and by 24-48% at 24 h. In addition, MION increased the T(1)-weighted signal intensity in all tissues. T(2) yielded a higher sensitivity than T(1)-weighted images. Functional MRI with MION is a noninvasive technique with regard to the eye, permitting measurement of blood volume and cellular uptake of the contrast agent. Further study is necessary to determine the feasibility of this technique for the tumor diagnosis and evaluation of tumor viability following treatments.

Animals↗