Search PubMed⌕ Search

Biomedical subjects

Ken Kadoya

Publications and source records attributed to Ken Kadoya.

5 recordsLinked to original sources

Clinical outcome of posterolateral endoscopic surgery for pyogenic spondylodiscitis: results of 15 patients with serious comorbid conditions.

STUDY DESIGN: Clinical results of posterolateral endoscopic debridement and irrigation followed by percutaneous drainage for pyogenic spondylodiscitis were analyzed. OBJECTIVES: To report clinical results of transforaminal endoscopic surgery for pyogenic spondylodiscitis and to evaluate the effectiveness of this procedure in treatment of pyogenic spinal infections. SUMMARY OF BACKGROUND DATA: Pyogenic spinal infections have been increasing due to the development of medical treatment for patients with comorbid medical problems. Common treatments for spinal infections are administration of antibiotics or surgical debridement with bone grafts. There have been no reports, however, regarding the clinical outcome of posterolateral endoscopic treatment for pyogenic spinal infections. METHODS: Fifteen consecutive patients with pyogenic spondylodiscitis in the thoracic or lumbar spine were enrolled. Preoperative antibiotic treatment had failed in all the patients. The procedures consisted of posterolateral endoscopic debridement and irrigation followed by percutaneous drainage through single portal under the combination of local and intravenous anesthesia. Pain response using visual analog scale (VAS, 0-100 mm), inflammation parameters, and duration of antibiotic therapy were investigated. Radiologic evaluation focused on bony fusion, local kyphosis, disc height reduction, and abscess formation. RESULTS: All patients showed immediate pain reduction after surgery. Averaged VAS for pain was 86 before surgery and 25 at postoperative 1 week. Average of CRP was 4.00 mg/dL before surgery and 1.88 mg/dL at postoperative 1 week. Averaged duration of antibiotics therapy was 3.7 weeks. Spinal fusion was obtained in 13 patients. Two patients with neurologic deficits due to epidural abscess returned to normal. Preoperative psoas abscess in 6 patients disappeared after surgery on MRI. CONCLUSIONS: Posterolateral spinal endoscopic debridement and irrigation brought immediate pain reduction and good clinical results to patients who had comorbid medical problems and had pyogenic spondylodiscitis.

Adolescent↗

Vertebral osteonecrosis associated with sarcoidosis. Case report.

Sarcoidosis is a systemic disease commonly affecting lung, skin, or eye. Sarcoidosis involved with osseous structures occurs in approximately 5% of patients, usually involving small bones. Spinal sarcoidosis is extremely rare. The authors report on a man in whom examination of a subclavicular lymph node biopsy specimen and its spinal involvement had established a diagnosis of sarcoidosis and who had undergone steroid therapy. Despite intensive conservative treatment, the authors observed progressive collapse of L-2 requiring spinal decompressive and reconstructive surgeries. Histological evaluation of the collapsed vertebra did not show the typical noncaseating granuloma; rather, the authors observed osteonecrosis of the entire L-2 structure without reactive cellular activities. Other potential diagnoses including infectious disease, metastatic spinal tumor, and osteoporotic vertebral collapse were excluded based on laboratory data, imaging studies, and pathological findings. Complete necrosis of the entire L-2 vertebra in this case can be considered as a rare clinical manifestation of spinal sarcoidosis. Because of osteopenia and systemic bone fragility, combined anterior-posterior spinal reconstructive surgery was performed to restabilize the severely damaged spine.

Diagnosis, Differential↗

Two-year observation of artificial intervertebral disc replacement: results after supplemental ultra-high strength bioresorbable spinal stabilization.

OBJECT: This 2-year experimental study was conducted to investigate the efficacy of a bioactive three-dimensional (3D) fabric disc for lumbar intervertebral disc replacement. The authors used a bioresorbable spinal fixation rod consisting of a forged composite of particulate unsintered hydroxyapatite/poly-L-lactide acid (HA/PLLA) for stability augmentation. The biomechanical and histological alterations as well as possible device-related loosening were examined at 2 years postoperatively. METHODS: Two lumbar intervertebral discs (L2-3 and L4-5) were replaced with the 3D fabric discs, which were augmented by two titanium screws and a spanning bioresorbable rod (HA/PLLA). The segmental biomechanics and interface bone ingrowth were investigated at 6, 15, and 24 months postoperatively, and results were compared with the other two surgical groups (3D fabric disc alone; 3D fabric disc with additional anterior instrumentation stabilization). The 3D fabric disc and HA/PLLA-spinal segments demonstrated segmental mobility at 15 and 24 months; however, the range of motion (ROM) in flexion-extension decreased to 49 and 40%, respectively, despite statistically equivalent preserved torsional ROM. Histologically there was excellent osseous fusion at the 3D fabric disc surface-vertebral body interface. At 2 years posttreatment, no adverse tissue reaction nor aseptic loosening of the device was observed. CONCLUSIONS: Intervertebral disc replacement with the 3D fabric disc was viable and when used in conjunction with the bioresorbable HA/PLLA spinal augmentation. Further refinements of device design to create a stand-alone type are necessary to obviate the need for additional spinal stabilization.

Animals↗

Static and dynamic analysis of five anterior instrumentation systems for thoracolumbar scoliosis.

STUDY DESIGN: A nondestructive biomechanical investigation among five anterior spinal instrumentation systems for scoliosis. OBJECTIVES: The purpose of this study is to analyze the static and dynamic biomechanical stability of five different systems. SUMMARY OF BACKGROUND DATA: Although a variety of anterior spinal instrumentation systems for scoliosis are available, very few attempts have been made at comparative biomechanical studies. METHODS: Thirty calf spines were underwent static biomechanical tests, including flexion-extension, axial rotation, and lateral bending loading modes in the multisegmental spinal model. Five anterior instrumentation systems included: 1) Texas Scottish Rite Hospital system; 2) Bad Wildungen Metz; 3) anterior ISOLA; 4) Cotrel-Dubousset Hoph; and 5) Kaneda Anterior Scoliosis System. The initial and postfatigue stability after a cyclic loading test were analyzed by measuring the range of motion at instrumented segments compared to the intact within the same specimen (% to intact). RESULTS: Two-rod systems showed a significant decrease in range of motion compared to one-rod systems in flexion-extension (P < 0.001) and axial rotation (P < 0.05). In lateral bending, all systems demonstrated a significant decrease in range of motion of less than 40% to the intact (P < 0.001). After cyclical loading test, all systems increased in range of motion. In flexion-extension, one-rod systems depicted a significant increase in range of motion, compared to two-rod systems (P < 0.05). CONCLUSIONS: In the initial stability analysis, two-rod systems are superior to one-rod systems. For one-rod systems, repeated physiologic loading may result in reduced stability in flexion-extension.

Analysis of Variance↗

Artificial intervertebral disc replacement using bioactive three-dimensional fabric: design, development, and preliminary animal study.

STUDY DESIGN: A new artificial intervertebral disc was developed, and its intrinsic biomechanical properties, bioactivity, and the effectiveness as a total disc replacement were evaluated in vitro and in vivo. OBJECTIVES: To introduce a new artificial intervertebral disc and to evaluate the in vitro mechanical properties, fusion capacity to bone, and segmental biomechanics in the total intervertebral disc replacement using a sheep lumbar spine. SUMMARY OF BACKGROUND DATA: The loss of biologic fusion at the bone-implant interface and prosthetic failures have been reported in previous artificial discs. There have been no clinically applicable discs with detailed experimental testing of in vivo mechanics and interface fusion capacity. METHODS: The artificial intervertebral disc consists of a triaxial three-dimensional fabric (3-DF) woven with an ultra-high molecular weight polyethylene fiber, and spray-coated bioactive ceramics on the disc surface. The arrangement of weave properties was designed to produce mechanical behavior nearly equivalent to the natural intervertebral disc. Total intervertebral disc replacement at L2-L3 and L4-L5 was performed using 3-DF disc with or without internal fixation in a sheep lumbar spine model. The segmental biomechanics and interface histology were evaluated after surgery at 4 and 6 months. RESULTS: The tensile-compressive and torsional properties of prototype 3-DF were nearly equivalent to those of human lumbar disc. The lumbar segments replaced with 3-DF disc alone showed a significant decrease of flexion-extension range of motion to 28% of control values as well as partial bony fusion at 6 months. However, the use of temporary fixation provided a nearly physiologic mobility of the spinal segment after implant removal as well as excellent bone-disc fusion at 6 months. CONCLUSION: An artificial intervertebral disc using a three-dimensional fabric demonstrated excellent in vitro and in vivo performance in both biomechanics and interface histology. There is a potential for future clinical application.

Animals↗